Test Report_DCD_SER180723803002E-Wireless

FCC ID: A4E-ITABLE406

Test Report

Download: PDF
FCCID_3966527

                                                               Report No.: SER180723803002E




                              FCC Test Report
                      FCC ID: A4E-ITABLE406

                          Product: Smart Sofa Control Panel
                       Trade Name: iTable
                   Model Number: iTable406
                      Serial Model: N/A
                       Report No.: SER180723803002E




                                          Prepared for

                                   eMoMo Technology Co., Ltd
        Fourth Floor, Yonghe Building, Taiwan Industrial P Shiyan, Baoan, Shenzhen,
                                    Guangdong China


                                          Prepared by

                          Shenzhen NTEK Testing Technology Co., Ltd.
              1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street,
                                 Bao’an District, Shenzhen P.R. China
                         Tel.: +86-0755-61156588 Fax.: +86-0755-61156599
                                      Website: www.ntek.org.cn




Version.1.1                                                                     Page 1 of 26


                                                                                        Report No.: SER180723803002E



                                        TEST RESULT CERTIFICATION

Applicant’s name ................. : eMoMo Technology Co., Ltd
                                               Fourth Floor, Yonghe Building, Taiwan Industrial P Shiyan, Baoan,
Address ................................. :
                                               Shenzhen, Guangdong China
Manufacturer's Name .......... : eMoMo Technology Co., Ltd
                                               Fourth Floor, Yonghe Building, Taiwan Industrial P Shiyan, Baoan,
Address ................................. :
                                               Shenzhen, Guangdong China
Product description
Product name............................ : Smart Sofa Control Panel
Model and/or type reference : iTable406
                                               FCC part 15C:2018
Standards ............................. :
                                     ANSI C63.10:2013
This device described above has been tested by Shenzhen NTEK Testing Technology Co., Ltd., and the test
results show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.
This report shall not be reproduced except in full, without the written approval of Shenzhen NTEK Testing
Technology Co., Ltd., this document may be altered or revised by Shenzhen NTEK Testing Technology Co.,
Ltd., personnel only, and shall be noted in the revision of the document.

The test results of this report relate only to the tested sample identified in this report.
Date of Test ........................................... :
Date (s) of performance of tests ............. :              23 Jul. 2018 ~ 31 Jul. 2018
Date of Issue .......................................... :    31 Jul. 2018
Test Result.............................................. :   Pass




                         Testing Engineer                 :

                                                                             (Eileen Liu)


                         Technical Manager                :
                                                                         (Jason Chen)

                         Authorized Signatory :

                                                                          (Sam Chen)




 Version.1.1                                                                                             Page 2 of 26


                                                    Report No.: SER180723803002E




                              Table of Contents                      Page


 1 . TEST SUMMARY                                                          4
     1.1 FACILITIES AND ACCREDITATIONS                                      5
     1.2 LABORATORY ACCREDITATIONS AND LISTINGS                             5
     1.3 MEASUREMENT UNCERTAINTY                                            5
 2 . GENERAL INFORMATION                                                   7
     2.1 GENERAL DESCRIPTION OF EUT                                         7
     2.2 DESCRIPTION OF TEST SETUP                                          9
     2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL                  10
     2.4 MEASUREMENT INSTRUMENTS LIST                                     11
 3 . EMC EMISSION TEST                                                   12
     3.1 CONDUCTED EMISSION MEASUREMENT                                  12
        3.1.1 POWER LINE CONDUCTED EMISSION                              12
        3.1.2 TEST PROCEDURE                                             13
        3.1.3 TEST SETUP                                                 13
        3.1.4 EUT OPERATING CONDITIONS                                   13
        3.1.5 TEST RESULTS                                               14
     3.2 RADIATED EMISSION MEASUREMENT                                   18
        3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT                    18
        3.2.2 TEST PROCEDURE                                             19
        3.2.3 TEST SETUP                                                 20
        3.2.4 TEST RESULTS                                               21
     4. ANTENNA APPLICATION                                              26
         4.1 Antenna Requirement                                         26
         4.2 Result                                                      26




Version.1.1                                                          Page 3 of 26


                                                                   Report No.: SER180723803002E

1. TEST SUMMARY

Test procedures according to the technical standards:
                                          EMC Emission

         Standard             Test Item       FCC Rules         Limit       Judgment      Remark
                            Conducted
                                                §15.207        Class B        PASS
                             Emission
   FCC part 15C:2018         Radiated
                                                §15.209        Class B        PASS
   ANSI C63.10:2013          Emission
                            ANTENNA
                                                §15.203           /           PASS
                           APPLICATION
NOTE:
    (1) ’N/A’ denotes test is not applicable in this Test Report
    (2) For client’s request and manual description, the test will not be executed.




 Version.1.1                                                                           Page 4 of 26


                                                                          Report No.: SER180723803002E

1.1 FACILITIES AND ACCREDITATIONS

  All measurement facilities used to collect the measurement data are located at
 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen 518126
  P.R. China.
 The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and CISPR
 Publication 22.


1.2 LABORATORY ACCREDITATIONS AND LISTINGS
 Site Description
 CNAS-Lab.                       :   The Laboratory has been assessed and proved to be in compliance with
                                     CNAS-CL01:2006 (identical to ISO/IEC 17025:2005)
                                     The Certificate Registration Number is L5516.
 IC-Registration                 :   The Certificate Registration Number is 9270A-1.
 FCC- Accredited                 :   Test Firm Registration Number: 463705.
                                     Designation Number: CN1184
 A2LA-Lab.                       :   The Certificate Registration Number is 4298.01
                                     This laboratory is accredited in accordance with the recognized
                                     International Standard ISO/IEC 17025:2005 General requirements for
                                     the competence of testing and calibration laboratories.
                                     This accreditation demonstrates technical competence for a defined
                                     scope and the operation of a laboratory quality management system
                                     (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).
 Name of Firm                    :   Shenzhen NTEK Testing Technology Co., Ltd.
 Site Location                   :   1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang
                                     Street, Bao’an District, Shenzhen 518126 P.R. China.




 1.3 MEASUREMENT UNCERTAINTY

     The reported uncertainty of measurement y ± U, where expended uncertainty U is based on
     a standard uncertainty multiplied by a coverage factor of k=2, providing a level of confidence
     of approximately 95 %.

     A. Conducted Measurement :

       Test Site Method          Measurement Frequency Range              U,(dB)            NOTE
       NTEKC01 ANSI                   150 KHz ~ 30MHz                      3.2

     B. Radiated Measurement :

       Test Site Method          Measurement Frequency Range              U,(dB)            NOTE
       NTEKA01 ANSI                   30MHz ~ 1000MHz                      4.7
                                       1GHz ~12.4GHz                       5.0




  Version.1.1                                                                                Page 5 of 26


                                                              Report No.: SER180723803002E

                                 Revision History


         Report No.    Version               Description                  Issued Date

    SER180723803002E   Rev.01           Initial issue of report           31 Jul.2018




Version.1.1                                                                    Page 6 of 26


                                                                        Report No.: SER180723803002E


2. GENERAL INFORMATION

2.1 GENERAL DESCRIPTION OF EUT


                                    Product Feature and Specification

   Equipment       Smart Sofa Control Panel

   Trade Name      iTable

   FCC ID          A4E-ITABLE406

   Model No.       iTable406

   Serial Model    N/A

   Model Difference N/A

   Operating
                   100KHz~205KHz
   Frequency

   Modulation
                   Induction
   Technique

   Antenna Type    Induction coil

                      AC supply:
                   Input: AC 100~240 50/60Hz
                   Output1: AC 100~240 50/60Hz;
   Power supply    Output2: DC 5V,2A
                     Adapter supply:


   Output          5W*2

   HW Version      V1.0

   SW Version      V1.0




 Version.1.1                                                                             Page 7 of 26


                                                                          Report No.: SER180723803002E

2.1.1 DESCRIPTION OF TEST MODES

EUT Configuration
The EUT configuration for testing is installed on RF field strength measurement to meet the
Commissions requirement and operating in a manner which intends to maximize its emission
characteristics in a continuous normal application.

EUT Exercise
The Transmitter was operated in the normal operating mode. The TX frequency was fixed which was
for the purpose of the measurements.


The following summary table is showing all test modes to demonstrate in compliance with the standard.
                                                 Test Cases
         Test Item                                     Data Rate/ Modulation

      AC Conducted
                                                        Mode 1: Max load*
        Emission
      Radiated Test
                                                         Mode 1: Max load
         Cases

 (*)EUT can only access the specified load, can not adjust the size of the load

Carrier Frequency and Channel list:


                          Channel                                     Frequency(MHz)

                              1                                             0.110

                              2                                             0.167

                              3                                             0.205

 The EUT supports one voltage input and output. The EUT performs one voltage mode pretests.




  Version.1.1                                                                                 Page 8 of 26


                                                         Report No.: SER180723803002E




2.2 DESCRIPTION OF TEST SETUP


For AC Conducted Emission Mode

                                                  AC
                                           E-1    PLUG
                                           EUT
                                          E-2
                                        Load4*2




For Radiated Test Cases



                                  E-1
                                  EUT
                                   E-2
                                 Load4*2




 Version.1.1                                                              Page 9 of 26


                                                                  Report No.: SER180723803002E


2.3 DESCRIPTION TEST PERIPHERAL AND EUT PERIPHERAL

The EUT has been tested as an independent unit together with other necessary accessories or
support units. The following support units or accessories were used to form a representative test
configuration during the tests.

Item          Equipment          Brand        Model/Type No.            Series No.          Note
        Smart Sofa Control
  E-1                            iTable          iTable406                 N/A              EUT
              Panel
 E-2           Load4*2            N/A               N/A                    N/A        Peripherals




 Item     Cable Type      Shielded Type   Ferrite Core         Length                Note




 Note:
  (1)     The support equipment was authorized by Declaration of Confirmation.
  (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.
  (3)     “YES” means “shielded” “with core”; “NO” means “unshielded” “without core”.




Version.1.1                                                                          Page 10 of 26


                                                                        Report No.: SER180723803002E

2.4 MEASUREMENT INSTRUMENTS LIST

Radiation Test equipment
          I
                                                                                               Calibrati
          tKind of                                                     Last       Calibrated
                        Manufacturer    Type No.      Serial No.                                  on
         Equipment
          e                                                         calibration     until
                                                                                                period
          m
         Spectrum
  1                        Aglient       E4407B      MY45108040 2018.05.19        2019.05.18    1 year
          Analyzer
         Spectrum
  2                        Agilent       N9020A      MY49100060 2017.10.26        2018.10.25    1 year
          Analyzer
  4     Test Receiver       R&S           ESPI          101318     2018.05.19     2019.05.18    1 year
  5     Bilog Antenna      TESEQ        CBL6111D        31216      2018.04.08     2019.04.07    1 year
         50Ω Coaxial
  6                        Anritsu       MP59B       6200983705    2018.05.19     2019.05.18    1 year
           Switch
                                       EMC051835
  7       Amplifier         EMC                         980246     2017.12.06     2018.12.06    1 year
                                           SE
                                       TTA1840-35-
  8       Amplifier        MITEQ                        177156     2017.08.07     2018.08.06    1 year
                                           HG
  9     Loop Antenna        ARA        PLA-1030/B        1029      2018.05.19     2019.05.18    1 year
          Test Cable
  10                         N/A          R-01           N/A       2017.04.21     2020.04.20    3 year
        (9KHz-30MHz)
          Test Cable
  11                         N/A          R-02           N/A       2017.04.21     2020.04.20    3 year
        (30MHz-1GHz)


Conduction Test equipment

          Kind of                                                     Last        Calibrated    Calibration
 Item                   Manufacturer    Type No.      Serial No.
         Equipment                                                 calibration      until         period
   1    Test Receiver      R&S           ESCI          101160      2018.05.19     2019.05.18      1 year
   2           LISN        R&S          ENV216         101313      2018.04.18     2019.04.17      1 year
                    SCHWARZBE
   3           LISN           NNLK 8129               8129245      2018.05.19     2019.05.18      1 year
                       CK
        50Ω Coaxial  ANRITSU
   4                           MP59B                 6200983704    2018.05.19     2019.05.18      1 year
           Switch     CORP
         Test Cable
   5    (9KHz-30MH     N/A      C01                      N/A       2017.04.21     2020.04.20      3 year
             z)
         Test Cable
   6    (9KHz-30MH     N/A      C02                      N/A       2017.04.21     2020.04.20      3 year
             z)
         Test Cable
   7    (9KHz-30MH     N/A      C03                      N/A       2017.04.21     2020.04.20      3 year
             z)




 Version.1.1                                                                                   Page 11 of 26


                                                                         Report No.: SER180723803002E


3. EMC EMISSION TEST

3.1 CONDUCTED EMISSION MEASUREMENT

3.1.1 POWER LINE CONDUCTED EMISSION (Frequency Range 150KHz-30MHz)

                                                                 limit
                    FREQUENCY (MHz)
                                                 Quasi-peak              Average
                          0.15 -0.5                  66 - 56 *           56 - 46 *
                          0.50 -5.0                   56.00               46.00
                          5.0 -30.0                   60.00               50.00
        Note:
          (1) The tighter limit applies at the band edges.
          (2) The limit of " * " marked band means the limitation decreases linearly with the
              logarithm of the frequency in the range.



The following table is the setting of the receiver
               Receiver Parameters                                         Setting
                    Attenuation                                             10 dB
                 Start Frequency                                          0.15 MHz
                 Stop Frequency                                            30 MHz
                   IF Bandwidth                                             9 kHz




 Version.1.1                                                                              Page 12 of 26


                                                                    Report No.: SER180723803002E

3.1.2 TEST PROCEDURE
 a. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected
    to the power mains through a line impedance stabilization network (LISN). All other support
    equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling
    impedance for the measuring instrument.
 b. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back
    and forth in the center forming a bundle 30 to 40 cm long.
 c. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
    cable may be terminated, if required, using the correct terminating impedance. The overall
    length shall not exceed 1 m.
 d. LISN at least 80 cm from nearest part of EUT chassis.
 e. For the actual test configuration, please refer to the related Item –EUT Test Photos.


3.1.3 TEST SETUP




3.1.4 EUT OPERATING CONDITIONS
The EUT tested system was configured as the statements of 2.3 Unless otherwise a special
operating condition is specified in the follows during the testing.




Version.1.1                                                                            Page 13 of 26


                                                                        Report No.: SER180723803002E

3.1.5 TEST RESULTS


EUT:                 Smart Sofa Control Panel           Model Name. :         iTable406
Temperature:         26 ℃                               Relative Humidity:    54%
Pressure:            1010hPa                            Test Date:            2018-07-26
Test Mode:           Mode 1(Normal link)                Phase :               L
Test Voltage:        AC 120V/60Hz

     Frequency      Reading Level Correct Factor    Measure-ment     Limits        Margin
                                                                                               Remark
       (MHz)            (dBμV)            (dB)          (dBμV)      (dBμV)           (dB)

       0.1500           44.48             9.75          54.23        65.99          -11.76       QP

       0.1500           24.27             9.75          34.02        55.99          -21.97      AVG

       0.3860           34.81             9.74          44.55        58.15          -13.60       QP

       0.3860           33.11             9.74          42.85        48.15          -5.30       AVG

       0.6419           30.24             9.74          39.98        56.00          -16.02       QP

       0.6419           27.91             9.74          37.65        46.00          -8.35       AVG

       24.0780          27.50            10.63          38.13        60.00          -21.87       QP

       24.0780          22.66            10.63          33.29        50.00          -16.71      AVG
   Remark:
   1. All readings are Quasi-Peak and Average values.
   2. Factor = Insertion Loss + Cable Loss.




Version.1.1                                                                                  Page 14 of 26


                                                                         Report No.: SER180723803002E



EUT:                Smart Sofa Control Panel            Model Name. :        iTable406
Temperature:        26 ℃                                Relative Humidity:   54%
Pressure:           1010hPa                             Test Date:           2018-07-26
Test Mode:          Mode 1(Normal link)                 Phase :              N
Test Voltage:       AC 120V/60Hz

   Frequency      Reading Level Correct Factor    Measure-ment      Limits       Margin
                                                                                            Remark
     (MHz)            (dBμV)            (dB)          (dBμV)       (dBμV)         (dB)

     0.1500           46.16             9.74          55.90         65.99        -10.09       QP

     0.1500           27.23             9.74          36.97         55.99        -19.02      AVG

     0.3860           33.89             9.75          43.64         58.15        -14.51       QP

     0.3860           31.34             9.75          41.09         48.15         -7.06      AVG

     0.6419           29.55             9.75          39.30         56.00        -16.70       QP

     0.6419           26.54             9.75          36.29         46.00         -9.71      AVG

     24.0740          26.08            10.58          36.66         60.00        -23.34       QP

     24.0740          20.21            10.58          30.79         50.00        -19.21      AVG
 Remark:
 1. All readings are Quasi-Peak and Average values.
 2. Factor = Insertion Loss + Cable Loss.




Version.1.1                                                                               Page 15 of 26


                                                                        Report No.: SER180723803002E



EUT:                 Smart Sofa Control Panel           Model Name. :         iTable406
Temperature:         26 ℃                               Relative Humidity:    54%
Pressure:            1010hPa                            Test Date:            2018-07-26
Test Mode:           Mode 1(Normal link)                Phase :               L
Test Voltage:        AC 240V/60Hz

     Frequency      Reading Level Correct Factor    Measure-ment     Limits        Margin
                                                                                               Remark
       (MHz)            (dBμV)            (dB)          (dBμV)      (dBμV)           (dB)

       0.1740           38.81             9.76          48.57        64.76          -16.19       QP

       0.1740           21.07             9.76          30.83        54.76          -23.93      AVG

       0.3820           34.50             9.74          44.24        58.23          -13.99       QP

       0.3820           32.38             9.74          42.12        48.23          -6.11       AVG

       0.6380           29.97             9.74          39.71        56.00          -16.29       QP

       0.6380           27.55             9.74          37.29        46.00          -8.71       AVG

       1.1500           26.44             9.74          36.18        56.00          -19.82       QP

       1.1500           22.56             9.74          32.30        46.00          -13.70      AVG

       24.0780          28.78            10.63          39.41        60.00          -20.59       QP

       24.0780          25.08            10.63          35.71        50.00          -14.29      AVG
   Remark:
   1. All readings are Quasi-Peak and Average values.
   2. Factor = Insertion Loss + Cable Loss.




Version.1.1                                                                                  Page 16 of 26


                                                                         Report No.: SER180723803002E

EUT:                Smart Sofa Control Panel            Model Name. :        iTable406
Temperature:        26 ℃                                Relative Humidity:   54%
Pressure:           1010hPa                             Test Date:           2018-07-26
Test Mode:          Mode 1(Normal link)                 Phase :              N
Test Voltage:       AC 240V/60Hz

   Frequency      Reading Level Correct Factor    Measure-ment      Limits       Margin
                                                                                            Remark
     (MHz)            (dBμV)            (dB)          (dBμV)       (dBμV)         (dB)

     0.1539           41.33             9.74          51.07         65.78        -14.71       QP

     0.1539           25.41             9.74          35.15         55.78        -20.63      AVG

     0.3820           33.22             9.75          42.97         58.23        -15.26       QP

     0.3820           31.01             9.75          40.76         48.23         -7.47      AVG

     0.6419           29.39             9.75          39.14         56.00        -16.86       QP

     0.6419           26.02             9.75          35.77         46.00        -10.23      AVG

     24.0740          24.69            10.58          35.27         60.00        -24.73       QP

     24.0740          19.08            10.58          29.66         50.00        -20.34      AVG
 Remark:
 1. All readings are Quasi-Peak and Average values.
 2. Factor = Insertion Loss + Cable Loss.




Version.1.1                                                                               Page 17 of 26


                                                                      Report No.: SER180723803002E



3.2 RADIATED EMISSION MEASUREMENT

3.2.1 LIMITS OF RADIATED EMISSION MEASUREMENT
The emissions from an intentional radiator shall not exceed the field strength levels specified in
the following table 15.209(a):




15.205 Restricted bands of operation




    Notes:
       (1) Measurement was performed at an antenna to the closed point of EUT distance of
             meters.
         (2) Emission level (dBuV/m)=20log Emission level (uV/m).
         (3) Only spurious frequency is permitted to locate within the Restricted Bands specified in
               provision of 15.205, and the emissions located in restricted bands also comply with
               15.209 limit.
         (4) The emission limits shown in the above table are based on measurements employing a
               CISPR quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz and
               above 1000 MHz. Radiated emission limits in these three bands are based on
               measurements employing an average detector




 Version.1.1                                                                             Page 18 of 26


                                                                    Report No.: SER180723803002E


 3.2.2 TEST PROCEDURE
    Test Arrangement for Radiated Emissions up to 1 GHz

   a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
        accredited test facility. The table was rotated 360 degrees to determine the position of the
        highest radiation.
   b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
        on the top of a variable-height antenna tower.
   c. The antenna is a broadband antenna(Blow 30M, use loop antenna), and its height is varied
      from one meter to four meters above the ground to determine the maximum value of the field
      strength. Both horizontal and vertical polarizations of the antenna are set to make the
      measurement.
   d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
      was tuned to heights from 1 meter to 4 meters and the rotatable table was turned from 0
      degrees to 360 degrees to find the maximum reading.

   Note: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is
    120kHz for quasi-peak detection (QP) at frequency below 1GHz.

    Test Arrangement for Radiated Emissions above 1 GHz.

   a. The EUT was placed on the top of a rotating table 0.8 meters above the ground at an
      accredited chamber room. The table was rotated 360 degrees to determine the position of the
      highest radiation.
   b. The EUT was set 3 meters away from the interference-receiving antenna, which was mounted
      on the top of a variable-height antenna tower.
   c. The height of antenna can be varied from one meter to four meters, the height of adjustment
      depends on the EUT height and the antenna 3dB beamwidth both, to detect the maximum
      value of the field strength. Both horizontal and vertical polarizations of the antenna are set to
      make the measurement.
   d. For each suspected emission, the EUT was arranged to its worst case and then the antenna
      was tuned to heights and the rotatable table was turned from 0 degrees to 360 degrees to find
      the maximum reading.

During the radiated emission test, the Spectrum Analyzer was set with the following configurations:

   Use the following receiver/spectrum analyzer settings:
   Span = wide enough to fully capture the emission being measured
   RBW=200Hz for 9KHz to 150KHz,
   RBW=9kHz for 150KHz to 30MHz,
   RBW=120KHz for 30MHz to 1GHz
   VBW ≥ 3*RBW
   Sweep = auto
   Detector function = QP
   Trace = max hold




 Version.1.1                                                                            Page 19 of 26


                                                           Report No.: SER180723803002E


3.2.3 TEST SETUP

For Radiated Emission Test Set-Up, Frequency Below 30MHz




For Radiated Emission 30~1000MHz




Version.1.1                                                                 Page 20 of 26


                                                                     Report No.: SER180723803002E

3.2.4 TEST RESULTS

TEST RESULTS (9KHz~30MHz)
EUT:               Smart Sofa Control Panel         Model Name. :      iTable406
Temperature:       24 ℃                             Relative Humidity: 54%
Pressure:          1010 hPa                         Test Date :        2018-07-26
Test Mode :        Low frequency/Max Load           Polarization :       X
Test Power :       AC 120V/60Hz


               Frequency    Ant.Pol.   Emissio Limits    Margin      Remark
                                        n Level
                 (MHz)                 (dBuV/m) (dBuV/m) (dB)
                 0.016           X       43.26  123.522 -80.26 Avg
                                                                Avg(fundamenta
                 0.110           X       69.84  106.776 -36.94
                                                                l frequency)
                 0.312           X       41.15   97.721 -56.57 Avg
                 0.391           X       33.25   95.761 -62.51 Avg
                 5.509           X       43.69   69.542 -25.85 QP


Note:
 Below 30MHz, Pre-test the X, Y, Z axis to find X axis is worst case, so only record X axis test data.
 X: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 0 degrees.
 Y: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 90 degrees.
 Z: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 180 degrees.




 Version.1.1                                                                            Page 21 of 26


                                                                              Report No.: SER180723803002E



EUT:               Smart Sofa Control Panel                 Model Name. :      iTable406
Temperature:       24 ℃                                     Relative Humidity: 54%
Pressure:          1010 hPa                                 Test Date :        2018-07-26
Test Mode :        Mid frequency/Max Load                   Polarization :        X
Test Power :       AC 120V/60Hz


                Frequency   Ant.Pol.   Emission    Limits       Margin       Remark
                                         Level
                  (MHz)                (dBuV/m)   (dBuV/m)       (dB)
                                                                         Avg(fundamental
                    0.167      X        75.95     103.1500      -27.20
                                                                         frequency)
                    0.406      X         45.21    95.4340       -50.22   Avg
                    4.112      X        39.980    69.542        -29.56   QP
                   10.120      X        36.410    69.542        -33.13   QP
                   23.198      X        35.570    69.542        -33.97   QP



Note:
 Below 30MHz, Pre-test the X, Y, Z axis to find X axis is worst case, so only record X axis test data.
 X: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 0 degrees.
 Y: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 90 degrees.
 Z: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 180 degrees.




 Version.1.1                                                                                   Page 22 of 26


                                                                       Report No.: SER180723803002E



EUT:                   Smart Sofa Control Panel       Model Name. :      iTable406
Temperature:           24 ℃                           Relative Humidity: 54%
Pressure:              1010 hPa                       Test Date :        2018-07-26
Test Mode :            High frequency/Max Load        Polarization :      X
Test Power :           AC 120V/60Hz


         Frequency       Ant.Pol.   Emission      Limits     Margin           Remark
                                      Level
               (MHz)                (dBuV/m)   (dBuV/m)       (dB)
               0.085        X         45.73    109.0160      -63.29    Avg
                                                                       Avg(fundamental
               0.205        X         76.16    101.3691      -25.21
                                                                       frequency)
           1.105            X        42.644       67.475     -24.83    QP
           9.623            X        43.746       69.542     -25.80    QP
           13.421           X        35.715       69.542     -33.83    QP

Note:
 Below 30MHz, Pre-test the X, Y, Z axis to find X axis is worst case, so only record X axis test data.
 X: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 0 degrees.
 Y: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 90 degrees.
 Z: Field strength which this device generates since the position of the charging coil and loop
 antenna differ by 180 degrees.




 Version.1.1                                                                             Page 23 of 26


                                                                    Report No.: SER180723803002E

TEST RESULTS (30MHz ~1000MHz)
 Note: The High/ Middle/ Low frequency mode has been tested. But the High frequency mode is the
worst mode, just reported the worst data.
 EUT:                    Smart Sofa Control Panel   Model Name. :        iTable406
 Temperature:            24 ℃                       Relative Humidity:   54%
 Pressure:               1010 hPa                   Test Date :          2018-07-26
 Test Mode :             High frequency/Max Load    Polarization :       Horizontal
 Test Power :            AC 120V/60Hz

                                Meter               Emission
 Polar         Frequency                   Factor                  Limits      Margin
                               Reading               Level
 (H/V)                                                                                      Remark
                 (MHz)          (dBuV)      (dB)    (dBuV/m)     (dBuV/m)       (dB)
   H            64.2074         28.94       6.52     35.46         40.00        -4.54         QP
   H           146.8874         25.85       13.00    38.85         43.50        -4.65         QP
   H           193.0945         27.73       9.97     37.70         43.50        -5.80         QP
   H           322.1886         23.00       16.57    39.57         46.00        -6.43         QP
   H           425.0280         21.44       20.22    41.66         46.00        -4.34         QP
   H           492.4685         19.14       21.76    40.90         46.00        -5.10         QP

Remark:

Factor = Antenna Factor + Cable Loss - Amplifier.




 Version.1.1                                                                            Page 24 of 26


                                                                    Report No.: SER180723803002E

 EUT:                    Smart Sofa Control Panel   Model Name. :        iTable406
 Temperature:            24 ℃                       Relative Humidity:   54%
 Pressure:               1010 hPa                   Test Date :          2018-07-26
 Test Mode :             High frequency/Max Load    Polarization :       Vertical
 Test Power :            AC 120V/60Hz

                                 Meter              Emission
 Polar         Frequency                   Factor                  Limits      Margin
                                Reading              Level
 (H/V)                                                                                      Remark
                 (MHz)          (dBuV)      (dB)    (dBuV/m)      (dBuV/m)       (dB)
   V           63.9827           30.67       6.52    37.19         40.00        -2.81         QP
   V           96.0986           28.62      11.08    39.70         43.50        -3.80         QP
   V           119.8555          25.66      13.18    38.84         43.50        -4.66         QP
   V           144.3348          26.51      13.16    39.67         43.50        -3.83         QP
   V           446.4141          19.03      20.34    39.37         46.00        -6.63         QP
   V           468.8761          17.94      20.94    38.88         46.00        -7.12         QP

Remark:

Factor = Antenna Factor + Cable Loss - Amplifier.




 Version.1.1                                                                            Page 25 of 26


                                                                           Report No.: SER180723803002E



4. ANTENNA APPLICATION
4.1 Antenna Requirement
15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be designed to
ensure that no antenna other than that furnished by the responsible partyshall be used with the device.
4.2 Result

The EUT antenna is permanent attached antenna. It comply with the standard requirement.




                                               END REPORT