SPEN rf exposure report

FCC ID: A3LSMN975F

RF Exposure Info

Download: PDF
FCCID_4350196

          RF EXPOSURE EVALUATION DOCUMENT


                           FOR
              WPT (Wireless Power Transfer)



  MODEL NUMBER: SM-N975F/DS, SM-N975F, SM-N975X


                       FCC ID: A3LSMN975F



                  ISSUE DATE: 6/27/2019


                       Prepared for
               SAMSUNG ELECTRONICS CO., LTD.
         129 SAMSUNG-RO, YEONGTONG-GU, SUWON-SI,
                 GYEONGGI-DO, 16677, KOREA


                        Prepared by
                      UL Korea, Ltd.

26th floor, 152, Teheran-ro, Gangnam-gu Seoul, 06236, Korea

    Suwon Test Site: UL Korea, Ltd. Suwon Laboratory
            218 Maeyeong-ro, Yeongtong-gu,
          Suwon-si, Gyeonggi-do, 16675, Korea
                   TEL: (031) 337-9902
                   FAX: (031) 213-5433


1. TEST Procedure
Per FCC Guidance, WPT function was evaluated for portable exposure condition.




2. Facilities and Accreditation

The test sites and measurement facilities used to collect data are located at

  Suwon

  Shield Room

UL Korea, Ltd. is accredited by IAS, Laboratory Code TL-637.
The full scope of accreditation can be viewed at http://www.iasonline.org/PDF/TL/TL-637.pdf.




3. Information of EQUIPMENT UNDER TEST

  Information

      Operating frequency (MHz)                        0.594

    Maximum output power (mW)                           50

             Charging type               Inductive wireless power transfer

          Operating duty factor                        0.23




4. Test Equipment


5. Measurement results

5.1. H-field measurement results of EUT’s 6 sides

                                           H-field measurement (A/m)
  Distance
                   Rear         Front         Edge.1       Edge.2         Edge.3      Edge.4
    0cm           0.9562       0.2934         0.0766       0.4962         0.0295       0.0178



5.2. H-field measurement results for 0cm to 10cm at Rear side.

                                                       H-field x (duty factor)        FCC
        Distance (cm)        H-field meas (A/m)
                                                               (A/m)               Limit (A/m)
             0                      0.9562                     0.2199
             1                      0.5195                     0.1195
             2                      0.2777                     0.0639
             3                      0.1587                     0.0365
             4                      0.0960                     0.0221
             5                      0.0655                     0.0151                 1.63
             6                      0.0428                     0.0098
             7                      0.0300                     0.0069
             8                      0.0222                     0.0051
             9                      0.0160                     0.0037
             10                     0.0100                     0.0023



5.3. Corrected H-field measurement

   Operating duty factor is based on Averaging time of §1.1310 table 1.

    ⚫     0.9668 A/m * 0.23 = 0.2199 A/m




                                              End.



Document Created: 2019-07-11 04:41:18