Test Report

FCC ID: A3LSMG977U

Test Report

Download: PDF
FCCID_4218770

                                        PCTEST ENGINEERING LABORATORY, INC.
                                                        7185 Oakland Mills Road, Columbia, MD 21046 USA
                                                              Tel. 410.290.6652 / Fax 410.290.6654
                                                                      http://www.pctest.com

                                                               MEASUREMENT REPORT
                                                                                 FCC Part 15B

    Applicant Name:                                                                              Date of Testing:
    Samsung Electronics Co., Ltd.                                                                01/22/2019 - 03/25/2019
    129, Samsung-ro,                                                                             Test Site/Location:
    Yeongtong-gu, Suwon-si                                                                       PCTEST Lab. Columbia, MD, USA
    Gyeonggi-do, 16677, Korea                                                                    Test Report Serial No.:
                                                                                                 1M1901100003-16.A3L


    FCC ID:                                                            A3LSMG977U
    APPLICANT:                                                         Samsung Electronics Co., Ltd.

    Application Type:                                                  Certification
    Model:                                                             SM-G977U
    EUT Type:                                                          Portable Handset
    FCC Classification:                                                Part 15 Class B Computing Device Peripheral (JBP)
    FCC Rule Part(s):                                                  FCC Part 15 Subpart B
    Test Procedure(s):                                                 ANSI C63.4-2014


    This equipment has been shown to be capable of compliance with the applicable technical standards as indicated in the measurement
    report and has been tested in accordance with the measurement procedures specified in ANSI C63.4-2014 (See Test Report). The results
    shown herein are also deemed satisfactory evidence of compliance with Industry Canada Interference-Causing Equipment Standard ICES-
    003. These measurements were performed with no deviation from the standards. Test results reported herein relate only to the item(s)
    tested.

    I attest to the accuracy of data. All measurements reported herein were performed by me or were made under my supervision and are
    correct to the best of my knowledge and belief. I assume full responsibility for the completeness of these measurements and vouch for the
    qualifications of all persons taking them.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 1 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                                               T A B L E                       O F             C O N T E N T S

                    Introduction ...................................................................................................................................... 3
                    1.1      Scope..................................................................................................................................................... 3
                    1.2      PCTEST Test Location .......................................................................................................................... 3
                    1.3      Test Facility / Accreditations .................................................................................................................. 3
                    PRODUCT INFORMATION ............................................................................................................. 4
                    2.1      Equipment Description ........................................................................................................................... 4
                    2.2      Device Capabilities ................................................................................................................................ 4
                    2.3      Test Configuration ................................................................................................................................. 4
                    2.4      EMI Suppression Device(s)/Modifications.............................................................................................. 4
                    DESCRIPTION OF TESTS .............................................................................................................. 5
                    3.1      Evaluation Procedure ............................................................................................................................ 5
                    3.2      AC Line Conducted Emissions .............................................................................................................. 5
                    3.3      Radiated Emissions ............................................................................................................................... 6
                    3.4      Environmental Conditions ...................................................................................................................... 6
                    SAMPLE CALCULATIONS .............................................................................................................. 7
                    4.1      Conducted Emission Measurement Sample Calculation ....................................................................... 7
                    4.2      Radiated Emission Measurement Sample Calculation .......................................................................... 7
                    Measurement Uncertainty ................................................................................................................ 8
                    TEST EQUIPMENT CALIBRATION DATA ...................................................................................... 9
                    TEST DATA ................................................................................................................................... 10
                    7.1      Summary ............................................................................................................................................. 10
                    7.2      Test Support Equipment ...................................................................................................................... 11
                    7.3      Radiated Measurement Data ............................................................................................................... 12
                    7.4      Line Conducted Measurement Data .................................................................................................... 20
                    CONCLUSION ............................................................................................................................... 28




                                                                                 MEASUREMENT REPORT                                                                Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                                Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                   Page 2 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 INTRODUCTION

1.1           Scope
Measurement and determination of electromagnetic emissions (EMC) of radio frequency devices including
intentional and/or unintentional radiators for compliance with the technical rules and regulations of the Federal
Communications Commission and Innovation, Science and Economic Development Canada.

1.2           PCTEST Test Location
These measurement tests were conducted at the PCTEST Engineering Laboratory, Inc. facility located at 7185
Oakland Mills Road, Columbia, MD 21046. The measurement facility is compliant with the test site requirements
specified in ANSI C63.4-2014.

1.3           Test Facility / Accreditations
Measurements were performed at PCTEST Engineering Lab located in Columbia, MD 21046, U.S.A.

     PCTEST is an ISO 17025-2005 accredited test facility under the American Association for Laboratory
      Accreditation (A2LA) with Certificate number 2041.01 for Specific Absorption Rate (SAR), Hearing Aid
      Compatibility (HAC) testing, where applicable, and Electromagnetic Compatibility (EMC) testing for FCC and
      Innovation, Science, and Economic Development Canada rules.

     PCTEST TCB is a Telecommunication Certification Body (TCB) accredited to ISO/IEC 17065-2012 by A2LA
      (Certificate number 2041.03) in all scopes of FCC Rules and ISED Standards (RSS).

     PCTEST facility is a registered (2451B) test laboratory with the site description on file with ISED.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 3 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 PRODUCT INFORMATION


2.1           Equipment Description
The Equipment Under Test (EUT) is the Samsung Portable Handset FCC ID: A3LSMG977U. The test data
contained in this report pertains only to the emissions due to the digital circuitry of the EUT.

Test Device Serial No.: 1276B, 1304B

2.2           Device Capabilities
This device contains the following capabilities:

850/1900 CDMA/EvDO Rev0/A, 1x Advanced (BC0, BC1), 850/1900 GPRS/EDGE, 850/1700/1900
WCDMA/HSPA, Multi-band LTE, 802.11b/g/n/ax WLAN, 802.11a/n/ac/ax UNII, Bluetooth (1x, EDR, LE), NFC,
ANT+, Wireless Power Transfer, n261 5G NR

2.3           Test Configuration
The EUT was tested in the following configurations for conducted emissions:

Conducted Test Configuration 1: Camera on (rear) + Charging (with travel adapter)
Conducted Test Configuration 2: Camera on (front) + Charging (with travel adapter)
Conducted Test Configuration 3: Charging (with travel adapter)
Conducted Test Configuration 4: Video + Audio playback from internal memory data + Charging (with travel adapter)
Conducted Test Configuration 5: USB Data Communication with PC (from external memory data)
Conducted Test Configuration 6: ToF Camera on + Charging (with travel adapter)

The EUT was tested in the following configurations for radiated emissions:

Radiated Test Configuration 1: Camera on (rear) + Charging (with travel adapter)
Radiated Test Configuration 2: Camera on (front) + USB OTG (with USB gender: mouse or keyboard)
Radiated Test Configuration 3: Wired LAN (with USB to LAN converter)
Radiated Test Configuration 4: Video + Audio playback from internal memory data + Display out (with USB to HDMI converter)
Radiated Test Configuration 5: USB Data Communication with PC (from external memory data)
Radiated Test Configuration 6: ToF Camera on + Charging (with travel adapter)

All equipment is placed on the test table top and arranged in a typical configuration in accordance with ANSI C63.4-
2014 and manipulated to obtain worst case emissions. All interconnecting cables were bundled as necessary in 30
- 40 cm lengths to maintain 40 cm from the ground plane.

For more information please see Section 7.0 for test data and the test setup photos document for the test setup
photographs.

2.4           EMI Suppression Device(s)/Modifications
No EMI suppression device(s) were added and no modifications were made during testing.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 4 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 DESCRIPTION OF TESTS

3.1           Evaluation Procedure
The measurement procedure described in the American National Standard for Methods of Measurement of Radio-
Noise Emission from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz (ANSI C63.4-
2014) was used in the measurement of the EUT.

Deviation from measurement procedure…………………………………………….....................................None

3.2           AC Line Conducted Emissions
The line-conducted facility is located inside a 10'x16'x9' shielded enclosure. The shielded enclosure is manufactured
by ETS Lindgren RF Enclosures. The shielding effectiveness of the shielded room is in accordance with MIL-Std-
285 or NSA 65-5. A 1m x 1.5m wooden table 80cm high is placed 40cm away from the vertical wall and 80cm away
from the sidewall of the shielded room. Two 10kHz-30MHz, 50/50H Line-Impedance Stabilization Networks
(LISNs) are bonded to the shielded room floor. Power to the LISNs is filtered by external high-current high-insertion
loss power line filters. The external power line filter is an ETS Lindgren Model LPRX-4X30 (100dB Attenuation,
14kHz-18GHz) and the two EMI/RFI filters are ETS Lindgren Model LRW-2030-S1 (100dB Minimum Insertion Loss,
14kHz – 10GHz). These filters attenuate ambient signal noise from entering the measurement lines. These filters
are also bonded to the shielded enclosure.

The EUT is powered from one LISN and the support equipment is powered from the second LISN. If the EUT is a
DC-powered device, power will be derived from the source power supply it normally will be powered from and this
supply line(s) will be connected to the second LISN. All interconnecting cables more than 1 meter were shortened
to a 1 meter length by non-inductive bundling (serpentine fashion) and draped over the back edge of the test table.
All cables were at least 40cm above the horizontal reference groundplane. Power cables for support equipment
were routed down to the second LISN while ensuring that that cables were not draped over the second LISN.

Sufficient time for the EUT, support equipment, and test equipment was allowed in order for them to warm up to
their normal operating condition. The RF output of the LISN was connected to the spectrum analyzer and
exploratory measurements were made to determine the frequencies producing the maximum emission from the
EUT. The spectrum was scanned from 150kHz to 30MHz with a spectrum analyzer. The detector function was set
to peak mode for exploratory measurements while the bandwidth of the analyzer was set to 10kHz. The EUT,
support equipment, and interconnecting cables were arranged and manipulated to maximize each emission. Once
the worst case emissions have been identified, the one EUT cable configuration/arrangement and mode of
operation that produced these emissions is used for final measurements on the same test site. The analyzer is set
to CISPR quasi-peak and average detectors with a 9kHz resolution bandwidth for final measurements.

Line conducted emissions test results are shown in Section 7.4. Automated test software was used to perform the
AC line conducted emissions testing.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 5 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


3.3           Radiated Emissions
The radiated test facilities consisted of an indoor 3 meter semi-anechoic chamber used for final measurements and
exploratory measurements, when necessary. The measurement area is contained within the semi-anechoic
chamber which is shielded from any ambient interference. The test site inside the chamber is a 6m x 5.2m elliptical,
obstruction-free area in accordance with Clause 5, Figure 5.7 of ANSI C63.4-2014. A raised turntable is used for
radiated measurement. It is a continuously rotatable, remote-controlled, metallic turntable and 2 meters (6.56 ft.) in
diameter. The turn table is flush with the raised floor of the chamber in order to maintain its function as a ground
plane. Absorbers are arranged on the floor between the turn table and the antenna mast in such a way so as to
maximize the reduction of reflections for measurements above 1GHz. . An 80cm tall test table made of Styrodur is
placed on top of the turn table. For measurements above 1GHz, an additional Styrodur pedestal is placed on top of
the test table to bring the total table height to 1.5m.

For all measurements, the spectrum was scanned through all EUT azimuths and from 1 to 4 meter receive antenna
height using a broadband antenna from 30MHz up to the upper frequency shown in 15.33(b)(1) depending on the
highest frequency generated or used in the device or on which the device operates or tunes. For frequencies above
1GHz, linearly polarized double ridge horn antennas were used. For frequencies below 30MHz, a calibrated loop
antenna was used. When exploratory measurements were necessary, they were performed at 1 meter test distance
inside the semi-anechoic chamber using broadband antennas, broadband amplifiers, and spectrum analyzers to
determine the frequencies and modes producing the maximum emissions. Sufficient time for the EUT, support
equipment, and test equipment was allowed in order for them to warm up to their normal operating condition. The
test set-up was placed on top of the 1 x 1.5 meter table. The EUT, support equipment, and interconnecting cables
were arranged and manipulated to maximize each emission. Appropriate precaution was taken to ensure that all
emissions from the EUT were maximized and investigated. The system configuration, mode of operation, turntable
azimuth, and receive antenna height was noted for each frequency found.

Final measurements were made in the semi-anechoic chamber using calibrated, linearly polarized broadband and
horn antennas. The test setup was configured to the setup that produced the worst case emissions. The spectrum
analyzer was set to investigate all frequencies required for testing to compare the highest radiated disturbances
with respect to the specified limits. The turntable containing the EUT was rotated through 360 degrees and the
height of the receive antenna was varied 1 to 4 meters and stopped at the azimuth and height producing the
maximum emission. Each emission was maximized by changing the orientation of the EUT through three orthogonal
planes and changing the polarity of the receive antenna, whichever produced the worst-case emissions.

All radiated measurements are performed in a chamber that meets the site requirements per ANSI C63.4-2014.
Additionally, radiated emissions below 30MHz are also validated on an Open Area Test Site to assert correlation
with the chamber measurements per the requirements of KDB 474788 D01.

3.4           Environmental Conditions
The temperature is controlled within range of 15oC to 35oC. The relative humidity is controlled within range of 10%
to 75%. The atmospheric pressure is monitored within the range 86-106kPa (860-1060mbar).




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 6 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 SAMPLE CALCULATIONS

4.1           Conducted Emission Measurement Sample Calculation
             @ 20.3 MHz

                           Class B limit                           = 60.0 dBV (Quasi-peak limit)
                           Reading                                 = - 57.8 dBm (calibrated quasi-peak level)
                           Convert to dBV                         = - 57.8 + 107 = 49.2 dBV


                           Margin                                  = 49.2 - 60.0 = - 10.8 dB
                                                                   = 10.8 dB below limit


4.2           Radiated Emission Measurement Sample Calculation
              @ 66.7 MHz
                           Class B limit                                         = 100 V/m = 40.0 dBV/m
                           Reading                                               = - 76.0 dBm (calibrated level)
                           Convert to dBV                                       = - 76.0 + 107 = 31.0 dBV
                           Antenna Factor + Cable Loss                           = 5.8 dB/m
                                                                   Total         = 36.8 dBV/m


                           Margin                                                = 36.8 - 40.0 = - 3.2 dB
                                                                                 = 3.2 dB below limit




                  Note:


                       Level [dBV] = 20 log 10 (Level [V/m])
                         Level [dBV] = Level [dBm] + 107




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 7 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 MEASUREMENT UNCERTAINTY

The measurement uncertainties shown below were calculated in accordance with the requirements of
ANSI C63.4-2014. All measurement uncertainty values are shown with a coverage factor of k = 2 to indicate a 95%
level of confidence. The measurement uncertainty shown below meets or exceeds the UCISPR measurement
uncertainty values specified in CISPR 16-4-2 and, thus, can be compared directly to specified limits to determine
compliance.


                                                  Contribution                                        Expanded Uncertainty (±dB)

                                          Conducted Disturbance                                                             3.09

                                    Radiated Disturbance (<1GHz)                                                            4.98

                                    Radiated Disturbance (>1GHz)                                                            5.07




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 8 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                   TEST EQUIPMENT CALIBRATION DATA

Test Equipment Calibration is traceable to the National Institute of Standards and Technology (NIST). Measurements
antennas used during testing were calibrated in accordance to the requirements of ANSI C63.5-2017.

   Manufacturer                  Model                                Description                               Cal Date         Cal Interval         Cal Due          Serial Number
   COM‐Power                    AL‐130R                        Active Loop Antenna                             8/10/2018            Annual           8/10/2019              121085
   Com‐Power                    PAM‐103                     Pre‐Amplifier (1‐1000MHz)                          9/17/2018            Annual           9/17/2019              441119
      Emco                        3115                        Horn Antenna (1‐18GHz)                           3/28/2018            Biennial         3/28/2020            9704‐5182
 Rohde & Schwarz                CMW500                     Radio Communication Tester                          6/8/2018             Annual           6/8/2019               112347
 Rohde & Schwarz                 ESU26                     EMI Test Receiver (26.5GHz)                         5/21/2018            Annual           5/21/2019              100342
 Rohde & Schwarz               SFUNIT‐Rx                        Shielded Filter Unit                           6/18/2018            Annual           6/18/2019              102134
      Sunol                       JB5                      Bi‐Log Antenna (30M ‐ 5GHz)                         4/19/2018            Biennial         4/19/2020             A051107
                                             Table 6-1. Annual Test Equipment Calibration Schedule


  Note:

  For equipment listed above that has a calibration date or calibration due date that falls within the test date range,
  care was taken to ensure that this equipment was used after the calibration date and before the calibration due
  date.




                                                                                   MEASUREMENT REPORT                                                              Approved by:
   FCC ID: A3LSMG977U
                                                                                      (CERTIFICATION)                                                              Quality Manager
   Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                   Page 9 of 28
   1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
  © 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
  All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
  microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
  rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 TEST DATA

7.1           Summary


                                   Test Date(s):                               01/22/2019 - 03/25/2019

                                   Test Engineer:




                         FCC Part 15 Section                                        Description                                             Result


                                      15.107                                Conducted Emissions                                             PASS


                                      15.109                                  Radiated Emissions                                            PASS

                                                               Table 7-1. Summary of Test Results




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 10 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.2           Test Support Equipment

                                                 Configuration 1
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
Samsung Earphone                       Model: N/A              S/N: EHS64AVFWE     Length:                                                                     125cm
                                                 Configuration 2
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
Samsung Earphone                       Model: N/A              S/N: EHS64AVFWE     Length:                                                                     125cm
Samsung OTG Adapter                    Model: N/A              S/N: N/A            Length:                                                                     N/A
Amazon Basics Mouse                    Model: MSU0939          S/N: 6F20200440B    Length:                                                                     177cm
                                                 Configuration 3
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
Samsung Earphone                       Model: N/A              S/N: EHS64AVFWE     Length:                                                                     125cm
Samsung OTG Adapter                    Model: N/A              S/N: N/A            Length:                                                                     N/A
AudioQuest Carbon Ethernet Adapter     Model: 202013           S/N: WISVVFQ4       Length:                                                                     N/A
Belkin Ethernet Cat 5E Cable           Model: N/A              S/N: N/A            Length:                                                                     163cm
                                                 Configuration 4
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
Samsung EVO SD Card                    Model: N/A              S/N: N/A            Length:                                                                     N/A
Samsung HDMI Adapter                   Model: EE‐HG950         S/N: R37K800KEG2LU3 Length:                                                                     N/A
ASUS 24" Monitor                       Model: VK248H           S/N: N/A            Length:                                                                     N/A
Amazon HDMI Cable                      Model: N/A              S/N: N/A            Length:                                                                     456cm
                                                 Configuration 5
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
Samsung EVO SD Card                    Model: N/A              S/N: N/A            Length:                                                                     N/A
Dell Laptop                            Model: Latitude E5570 S/N: H6TYTF2          Length:                                                                     N/A
Dell AC Adapter                        Model: HA65NM130        S/N: N/A            Length:                                                                     N/A
DYNEX USB PC Camera                    Model: DX‐WC101         S/N: 122D05BC006389 Length:                                                                     215cm
CISCO Router                           Model: Linksys E900     S/N: 12310C65201062 Length:                                                                     N/A
                                                 Configuration 6
Samsung Travel Adapter                 Model: EP‐TA800         S/N: R37M1JA0651DK3 Length:                                                                     N/A
Samsung USB Cable                      Model: N/A              S/N: N/A            Length:                                                                     103cm
                      Table 7-2. Test Support Equipment Used (Radiated and Conducted)

Note:        See test setup photographs for actual system test setup.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 11 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.3           Radiated Measurement Data
§15.109; ICES-003 (6.2)


Test Overview and Limit

All out of band radiated spurious emissions are measured with a spectrum analyzer connected to a receive antenna
while the EUT is operating at maximum power and at the appropriate frequencies. Only the radiated emissions of
the configuration that produced the worst case emissions are reported in this section.

All out of band emissions appearing in a restricted band as specified in Section 15.105 of the Title 47 CFR
and ICES-003 (6.2) must not exceed the limits shown in Table 7-3 per Section 15.109 and ICES-003 (6.2).

                                                 Frequency                       Field Strength Limit
                                                    [MHz]                               [V/m]
                                                   30 – 88                                100
                                                  88 – 216                                150
                                                 216 – 960                                200
                                                    > 960                                 500
                                                 Table 7-3. 3-Meter Radiated Limits (Section 15.109)

Test Procedures Used

ANSI C63.4-2014



Test Settings
             Quasi-Peak Field Strength Measurements
                    1. Analyzer frequency set to the frequency of the radiated spurious emission of interest
                    2. RBW = 100kHz, VBW = 300kHz (for emissions between 30MHz – 1GHz)
                    3. RBW = 1MHz, VBW = 3MHz (for emissions above 1GHz)
                    4. Detector = Quasi-peak (for emissions between 30MHz – 1GHz)
                    5. Detector = Peak (for emissions above 1GHz)
                    6. Sweep time = auto couple
                    7. Trace mode = max hold
                    8. Trace was allowed to stabilize


Test Setup
The EUT and measurement equipment were set up as shown test setup photos provided.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 12 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Notes

1.           All modes of operation were investigated and the worst-case emissions are reported.
2.           Radiated emissions were measured from 30MHz – 30GHz to ensure that the provisions of 15.33(b)(1) are
             satisfied with respect to the upper frequency scanning range. No Spurious emissions were detected within
             20dB of the limit above 18GHz.
3.           The radiated limits for unintentional radiators at a distance of 3 meters are used in the table above, as
             specified in 15.109(a).
4.            All readings are calibrated by a signal generator with accuracy traceable to the National Institute of
              Standards and Technology (NIST).
5.           AFCL (dB/m) = Antenna Factor (dB/m) + Cable Loss (dB)
6.           Level (dBV/m) = Analyzer Reading (dBm) + AFCL (dB/m) + 107
7.           Margin (dB) = Field strength (dBV/m) – Limit (dBV/m)
8.            Measurements are made using a CISPR quasi-peak detector with a 120kHz resolution bandwidth. Above
              1GHz, peak measurements are made using a peak detector with a resolution bandwidth of 1MHz and a
              video bandwidth of 3MHz and average measurements are made with a RMS detector using a resolution
              bandwidth of 1MHz and a video bandwidth of 3MHz.
9.            Calibrated linearly polarized broadband and horn antennas were used for measurements below and above
              1GHz, respectively. For measurements made below 1GHz, the results recorded using the broadband
              antenna are known to correlate with the results obtained by using a tuned dipole with an acceptable degree
              of accuracy. The VSWR for the measurement antennas was found to be less than 2:1.
10.           Calibrated low-loss microwaves cables and broadband amplifiers are used.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 13 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 1




                                Plot 7-1. Radiated Spurious Plot below 1GHz [Radiated Test Config. 1]




                                Plot 7-2. Radiated Spurious Plot above 1GHz [Radiated Test Config. 1]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      31.17            Quasi-Peak                V              106                334              -62.93              -9.90             34.17             40.00              -5.83
      38.73            Quasi-Peak                V              100                220              -58.33             -15.16             33.51             40.00              -6.49
      54.10            Quasi-Peak                V              100                293              -47.95             -22.16             36.89             40.00              -3.11
      66.15            Quasi-Peak                V              105                209              -61.40             -21.44             24.16             40.00             -15.84
      89.39            Quasi-Peak                V              103                189              -53.95             -21.51             31.54             43.52             -11.98
      97.02            Quasi-Peak                V              107                199              -55.11             -19.62             32.27             43.52             -11.25
                                         Table 7-4. Radiated Measurements [Radiated Test Config. 1]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 14 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 2




                                Plot 7-3. Radiated Spurious Plot below 1GHz [Radiated Test Config. 2]




                                Plot 7-4. Radiated Spurious Plot above 1GHz [Radiated Test Config. 2]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      38.04            Quasi-Peak                H              121                 95              -73.44             -14.62             18.94             40.00             -21.06
      41.78            Quasi-Peak                V              100                242              -73.78             -17.47             15.75             40.00             -24.25
      58.49            Quasi-Peak                V              104                329              -63.38             -22.07             21.55             40.00             -18.45
      63.00            Quasi-Peak                V              127                113              -70.18             -21.67             15.15             40.00             -24.85
      73.91            Quasi-Peak                H              101                100              -60.16             -21.10             25.74             40.00             -14.26
      81.90            Quasi-Peak                V              100                229              -72.86             -21.65             12.49             40.00             -27.51
                                         Table 7-5. Radiated Measurements [Radiated Test Config. 2]

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 15 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 3




                                Plot 7-5. Radiated Spurious Plot below 1GHz [Radiated Test Config. 3]




                                Plot 7-6. Radiated Spurious Plot above 1GHz [Radiated Test Config. 3]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      58.75            Quasi-Peak                V              111                281              -50.81             -22.04             34.15             40.00              -5.85
      74.59            Quasi-Peak                H              220                106              -56.57             -21.10             29.33             40.00             -10.67
      85.46            Quasi-Peak                H              201                 96              -57.73             -21.83             27.44             40.00             -12.56
     124.99            Quasi-Peak                H              159                194              -61.49             -15.54             29.97             43.52             -13.55
     189.75            Quasi-Peak                H              102                 30              -51.23             -17.37             38.40             43.52              -5.12
     250.00            Quasi-Peak                H              121                  6              -52.68             -16.81             37.51             46.02              -8.51
                                         Table 7-6. Radiated Measurements [Radiated Test Config. 3]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 16 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 4




                                Plot 7-7. Radiated Spurious Plot below 1GHz [Radiated Test Config. 4]




                                Plot 7-8. Radiated Spurious Plot above 1GHz [Radiated Test Config. 4]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      45.75            Quasi-Peak                V              141                297              -55.10             -19.96             31.94             40.00              -8.06
      57.56            Quasi-Peak                V              118                161              -57.67             -22.16             27.17             40.00             -12.83
      88.68            Quasi-Peak                V              116                133              -60.16             -21.63             25.21             43.52             -18.31
     222.91            Quasi-Peak                H              216                360              -58.50             -17.66             30.84             46.02             -15.18
     252.86            Quasi-Peak                V              112                190              -57.50             -16.80             32.70             46.02             -13.32
     322.08            Quasi-Peak                V              101                167              -52.92             -13.97             40.11             46.02              -5.91
                                         Table 7-7. Radiated Measurements [Radiated Test Config. 4]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 17 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 5




                                Plot 7-9. Radiated Spurious Plot below 1GHz [Radiated Test Config. 5]




                               Plot 7-10. Radiated Spurious Plot above 1GHz [Radiated Test Config. 5]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      44.27            Quasi-Peak                V              120                103              -65.41             -19.08             22.51             40.00             -17.49
      49.78            Quasi-Peak                V              151                108              -66.70             -21.42             18.88             40.00             -21.12
      55.38            Quasi-Peak                V              119                 85              -68.26             -22.24             16.50             40.00             -23.50
      82.99            Quasi-Peak                V              113                 31              -69.19             -21.75             16.06             40.00             -23.94
     149.39            Quasi-Peak                V              162                155              -72.76             -16.38             17.86             43.52             -25.66
     239.99            Quasi-Peak                H              232                325              -55.46             -16.77             34.77             46.02             -11.25
                                         Table 7-8. Radiated Measurements [Radiated Test Config. 5]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 18 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Radiated Test Config. 6




                               Plot 7-11. Radiated Spurious Plot below 1GHz [Radiated Test Config. 6]




                               Plot 7-12. Radiated Spurious Plot above 1GHz [Radiated Test Config. 6]

                                              Ant.         Antenna Turntable Analyzer                                                    Field
 Frequency                                                                                                             AFCL                       Limit                       Margin
                         Detector             Pol.          Height  Azimuth    Level                                                   Strength
   [MHz]                                                                                                              [dB/m]                    [dBμV/m]                       [dB]
                                             [H/V]           [cm]   [degree]  [dBm]                                                   [dBμV/m]
      34.26            Quasi-Peak                V              103                105              -69.10             -11.98             25.92             40.00             -14.08
      46.71            Quasi-Peak                V              114                109              -66.72             -20.45             19.83             40.00             -20.17
      58.80            Quasi-Peak                V              121                 42              -67.20             -22.04             17.76             40.00             -22.24
      69.75            Quasi-Peak                V              108                147              -67.26             -21.15             18.59             40.00             -21.41
     194.48            Quasi-Peak                V              171                166              -66.41             -16.78             23.81             43.52             -19.71
     200.10            Quasi-Peak                V              227                283              -59.21             -16.11             31.68             43.52             -11.84
                                         Table 7-9. Radiated Measurements [Radiated Test Config. 6]



                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 19 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


7.4           Line Conducted Measurement Data
§15.107; ICES-003 (6.1)

Test Overview and Limit

All AC line conducted spurious emissions are measured with a receiver connected to a grounded LISN while the
EUT is operating at its maximum duty cycle, at maximum power, and at the appropriate frequencies. All data rates
and modes were investigated for conducted spurious emissions. Only the conducted emissions of the configuration
that produced the worst case emissions are reported in this section.

All conducted emissions must not exceed the limits shown in the table below, per Section 15.107 and ICES-
003 (6.1).

                             Frequency of emission                                              Conducted Limit (dBV)
                                    (MHz)
                                                                                     Quasi-peak                                      Average
                                          0.15 – 0.5                                  66 to 56*                                      56 to 46*
                                           0.5 – 5                                       56                                             46
                                            5 – 30                                       60                                             50
                                                                    Table 7-10. Conducted Limits

*Decreases with the logarithm of the frequency.


Test Procedures Used

ANSI C63.4-2014


Test Settings

             Quasi-Peak Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = quasi-peak
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize
             Average Field Strength Measurements

             1. Analyzer center frequency was set to the frequency of the spurious emission of interest
             2. RBW = 9kHz (for emissions from 150kHz – 30MHz)
             3. Detector = RMS
             4. Sweep time = auto couple
             5. Trace mode = max hold
             6. Trace was allowed to stabilize


                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 20 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Test Setup

The EUT and measurement equipment were set up as shown in the test setup photos provided.

Test Notes

1.           All Modes of operation were investigated and the worst-case emissions are reported.
2.           The limit for Class B device(s) from 150kHz to 30MHz are specified in Section 15.107 and ICES-003.
3.           L1 = Phase; N = Neutral
4.           Corr. (dB) = Cable loss (dB) + LISN insertion factor (dB)
5.           QP/AV Level (dBµV) = QP/AV Reading (dBµV) + Factor (dB)
6.           Margin (dB) = QP/AV Limit (dBµV) – QP/AV Level (dBµV)
7.           Traces shown in plot are made using a peak detector.
8.           Deviations to the Specifications: None.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 21 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 1




                                                               Plot 7-13. Line Conducted Plot (L1)




                                                                Plot 7-14. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 22 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 2




                                                               Plot 7-15. Line Conducted Plot (L1)




                                                                Plot 7-16. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 23 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 3




                                                               Plot 7-17. Line Conducted Plot (L1)




                                                                Plot 7-18. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 24 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 4




                                                               Plot 7-19. Line Conducted Plot (L1)




                                                                Plot 7-20. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 25 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 5




                                                               Plot 7-21. Line Conducted Plot (L1)




                                                                Plot 7-22. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 26 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


Conducted Test Config. 6




                                                               Plot 7-23. Line Conducted Plot (L1)




                                                                Plot 7-24. Line Conducted Plot (N)

                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 27 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.


                 CONCLUSION

The data collected relate only to the item(s) tested and show that the Samsung Portable Handset
FCC ID: A3LSMG977U has been tested to comply with the requirements specified in §15.107 and §15.109 of the
FCC rules.




                                                                                 MEASUREMENT REPORT                                                              Approved by:
 FCC ID: A3LSMG977U
                                                                                    (CERTIFICATION)                                                              Quality Manager
 Test Report S/N:                       Test Dates:                    EUT Type:
                                                                                                                                                                 Page 28 of 28
 1M1901100003-16.A3L                    01/22/2019 - 03/25/2019 Portable Handset
© 2019 PCTEST Engineering Laboratory, Inc.                                                                                                                                    V 8.8 11/19/2018
All rights reserved. Unless otherwise specified, no part of this report may be reproduced or utilized in any part, form or by any means, electronic or mechanical, including photocopying and
microfilm, without permission in writing from PCTEST Engineering Laboratory, Inc. If you have any questions about this international copyright or have an enquiry about obtaining additional
rights to this report or assembly of contents thereof, please contact INFO@PCTEST.COM.



Document Created: 2019-04-05 21:23:04
Document Modified: 2019-04-05 21:23:04

© 2024 FCC.report