HAC_Appendix B

FCC ID: A3LSMG889A

Test Report

Download: PDF
FCCID_4331352

Test Laboratory: UL Korea Ltd. Suwon Laboratory                               Date: 2019-02-26

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 835 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4064; ConvF(1, 1, 1); Calibrated: 2018-11-15;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (8);SEMCAD X Version 14.6.10 (7331)

Dipole E-Field measurement 835MHz/835 MHz/Hearing Aid Compatibility Test at 15mm
distance (41x361x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 133.9 V/m; Power Drift = -0.01 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 120.1 V/m
Near-field category: M4 (AWF 0 dB)

                                        PMF scaled E-field
                                         Grid 1 M4 Grid 2 M4 Grid 3 M4
                                         114.7 V/m    116.4 V/m   112.5 V/m
                                         Grid 4 M4    Grid 5 M4   Grid 6 M4
                                         65.59 V/m    66.01 V/m   64.21 V/m
                                         Grid 7 M4    Grid 8 M4   Grid 9 M4
                                         117.6 V/m    120.1 V/m   116.8 V/m




             0 dB = 120.1 V/m = 41.59 dBV/m


                                                                                                 Plot No. 1


Test Laboratory: UL Korea Ltd. Suwon Laboratory                              Date: 2019-02-26

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 1880 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4064; ConvF(1, 1, 1); Calibrated: 2018-11-15;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (8);SEMCAD X Version 14.6.10 (7331)

Dipole E-Field measurement 1880MHz/1880 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 146.1 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 88.79 V/m
Near-field category: M3 (AWF 0 dB)

                                        PMF scaled E-field
                                         Grid 1 M3 Grid 2 M3 Grid 3 M3
                                         84.81 V/m   86.25 V/m   83.80 V/m
                                         Grid 4 M3   Grid 5 M3   Grid 6 M3
                                         63.54 V/m   64.05 V/m   63.35 V/m
                                         Grid 7 M3   Grid 8 M3   Grid 9 M3
                                         86.35 V/m   88.79 V/m   87.32 V/m




             0 dB = 88.79 V/m = 38.97 dBV/m




                                                                                                Plot No. 2


Test Laboratory: UL Korea Ltd. Suwon Laboratory                              Date: 2019-02-26

HAC-RF Emission
Communication System: UID 0, CW (0); Frequency: 2600 MHz; Duty Cycle: 1:1
Phantom section: RF Section
DASY5 Configuration:
- Probe: EF3DV3 - SN4064; ConvF(1, 1, 1); Calibrated: 2018-11-15;
- Sensor-Surface: (Fix Surface)
- Electronics: DAE4 Sn1447; Calibrated: 2018-03-15
- Phantom: HAC Test Arch with AMCC; Type: SD HAC P01 BB
- Measurement SW: DASY52, Version 52.8 (8);SEMCAD X Version 14.6.10 (7331)

Dipole E-Field measurement 2600MHz/2600 MHz/Hearing Aid Compatibility Test at
15mm distance (41x181x1): Interpolated grid: dx=0.5000 mm, dy=0.5000 mm
Device Reference Point: 0, 0, -6.3 mm
Reference Value = 67.51 V/m; Power Drift = 0.00 dB
PMR not calibrated. PMF = 1.000 is applied.
E-field emissions = 89.58 V/m
Near-field category: M3 (AWF 0 dB)

                                        PMF scaled E-field
                                         Grid 1 M3 Grid 2 M3 Grid 3 M3
                                         84.29 V/m   86.41 V/m   84.47 V/m
                                         Grid 4 M3   Grid 5 M3   Grid 6 M3
                                         81.53 V/m   82.31 V/m   81.12 V/m
                                         Grid 7 M3   Grid 8 M3   Grid 9 M3
                                         87.84 V/m   89.58 V/m   87.95 V/m




             0 dB = 89.58 V/m = 39.04 dBV/m




                                                                                                Plot No. 3



Document Created: 2019-07-09 03:59:11
Document Modified: 2019-07-09 03:59:11

© 2024 FCC.report