Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                         Date: 2019-03-25

20190325_SystemPerformanceCheck-D2600V2 SN 1097

Frequency: 2600 MHz; Duty Cycle: 1:1;  Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 2600 MHz; σ = 2.194 S/m; εr = 51.244; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Averaged Fast SAR: Polynomial fit
- Electronics: DAE4 Sn912; Calibrated: 2018-11-16
- Probe: EX3DV4 - SN7376; ConvF(7.49, 7.49, 7.49); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V6.0 (20deg); Type: QD OVA 003 AA; Serial: 2013

Body/Pin=100 mW/Area Scan (9x9x1): Measurement grid: dx=10mm, dy=10mm
Maximum value of SAR (measured) = 7.75 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 62.03 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 12.9 W/kg
SAR(1 g) = 5.85 W/kg; SAR(10 g) = 2.55 W/kg
Maximum value of SAR (measured) = 8.60 W/kg




                      0 dB = 8.60 W/kg = 9.34 dBW/kg




                                                                                                            Plot No. 1


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-03-25

20190325_SystemPerformanceCheck-D2600V2 SN 1097

Frequency: 2600 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 8.42 W/kg




                                                                                  Plot No. 2


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                          Date: 2019-03-27

20190327_SystemPerformanceCheck-D750V3 SN 1122

Frequency: 750 MHz; Duty Cycle: 1:1;  Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 750 MHz; σ = 0.903 S/m; εr = 43.447; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Averaged Fast SAR: Polynomial fit
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.86, 9.86, 9.86); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Middle); Type: QD000P40CD; Serial: TP:1854

Head/Pin=100 mW/Area Scan (7x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.02 W/kg

Head/Pin=100 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 34.16 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 1.25 W/kg
SAR(1 g) = 0.845 W/kg; SAR(10 g) = 0.560 W/kg
Maximum value of SAR (measured) = 1.03 W/kg




                      0 dB = 1.03 W/kg = 0.13 dBW/kg




                                                                                                             Plot No. 3


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-03-27

20190327_SystemPerformanceCheck-D750V3 SN 1122

Frequency: 750 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.03 W/kg




                                                                                  Plot No. 4


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                          Date: 2019-03-29

20190329_SystemPerformanceCheck-D835V2 SN 4d174

Frequency: 835 MHz; Duty Cycle: 1:1;  Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                              3
Medium parameters used: f = 835 MHz; σ = 0.99 S/m; εr = 55.038; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Averaged Fast SAR: Polynomial fit
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Body/Pin=100 mW/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 1.22 W/kg

Body/Pin=100 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 35.17 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 1.46 W/kg
SAR(1 g) = 0.986 W/kg; SAR(10 g) = 0.649 W/kg
Maximum value of SAR (measured) = 1.20 W/kg




                      0 dB = 1.20 W/kg = 0.79 dBW/kg




                                                                                                             Plot No. 5


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-03-29

20190329_SystemPerformanceCheck-D835V2 SN 4d174

Frequency: 835 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 1.20 W/kg




                                                                                  Plot No. 6


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                          Date: 2019-03-29

20190329_SystemPerformanceCheck-D1900V2 SN 5d199

Frequency: 1900 MHz; Duty Cycle: 1:1;  Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1900 MHz; σ = 1.458 S/m; εr = 38.639; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Averaged Fast SAR: Polynomial fit
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.43, 8.43, 8.43); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

Head/Pin=100 mW/Area Scan (7x7x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 6.05 W/kg

Head/Pin=100 mW/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 62.97 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 7.98 W/kg
SAR(1 g) = 4.28 W/kg; SAR(10 g) = 2.2 W/kg
Maximum value of SAR (measured) = 5.82 W/kg




                      0 dB = 5.82 W/kg = 7.65 dBW/kg




                                                                                                             Plot No. 7


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-03-29

20190329_SystemPerformanceCheck-D1900V2 SN 5d199

Frequency: 1900 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 5.67 W/kg




                                                                                  Plot No. 8


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                          Date: 2019-03-30

20190330_SystemPerformanceCheck-D2450V2 SN 939

Frequency: 2450 MHz; Duty Cycle: 1:1;  Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 2450 MHz; σ = 1.812 S/m; εr = 39.16; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Averaged Fast SAR: Polynomial fit
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(7.64, 7.64, 7.64); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.02 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7) (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 62.78 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 10.3 W/kg
SAR(1 g) = 5 W/kg; SAR(10 g) = 2.33 W/kg
Maximum value of SAR (measured) = 7.10 W/kg




                      0 dB = 7.10 W/kg = 8.51 dBW/kg




                                                                                                             Plot No. 9


Test Laboratory: UL Korea, Ltd. Suwon Laboratory               Date: 2019-03-30

20190330_SystemPerformanceCheck-D2450V2 SN 939

Frequency: 2450 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 8.20 W/kg




                                                                                  Plot No. 10