RF Exposure Info._20190404_v1 - 4788931341-S1V1 FCC Report SAR App B_SAR Highest

FCC ID: A3LSMA205YN

RF Exposure Info

Download: PDF
FCCID_4234934

Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-27

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:8.30042;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.905 S/m; εr = 42.417; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_GSM_Voice_ch.190/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.127 W/kg

RHS/Touch_GSM_Voice_ch.190/Zoom Scan (6x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 12.34 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 0.146 W/kg
SAR(1 g) = 0.115 W/kg; SAR(10 g) = 0.089 W/kg
Maximum value of SAR (measured) = 0.129 W/kg




                      0 dB = 0.129 W/kg = -8.89 dBW/kg




                                                                                                                Plot No. 1


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:2.60016;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.965 S/m; εr = 55.061; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/GPRS_3 slots_ch 190 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.244 W/kg

Rear/GPRS_3 slots_ch 190 15mm/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 16.10 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 0.330 W/kg
SAR(1 g) = 0.196 W/kg; SAR(10 g) = 0.111 W/kg
Maximum value of SAR (measured) = 0.252 W/kg




                      0 dB = 0.252 W/kg = -5.99 dBW/kg




                                                                                                                Plot No. 2


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

GSM 850

Frequency: 836.6 MHz; Duty Cycle: 1:2.60016;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.965 S/m; εr = 55.061; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/GPRS_3 Slots_ch 190 10mm (Hotspot)/Area Scan (8x14x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.578 W/kg

Rear/GPRS_3 Slots_ch 190 10mm (Hotspot)/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 24.87 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 0.807 W/kg
SAR(1 g) = 0.432 W/kg; SAR(10 g) = 0.229 W/kg
Maximum value of SAR (measured) = 0.575 W/kg




                      0 dB = 0.575 W/kg = -2.40 dBW/kg




                                                                                                                Plot No. 3


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

GSM 1900

Frequency: 1909.8 MHz; Duty Cycle: 1:8.30042;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1910 MHz; σ = 1.465 S/m; εr = 38.618; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.43, 8.43, 8.43); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Touch_GSM_voice_ch.810/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.0173 W/kg

LHS/Touch_GSM_voice_ch.810/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 3.257 V/m; Power Drift = 0.14 dB
Peak SAR (extrapolated) = 0.0190 W/kg
SAR(1 g) = 0.012 W/kg; SAR(10 g) = 0.00652 W/kg
Maximum value of SAR (measured) = 0.0167 W/kg




                      0 dB = 0.0167 W/kg = -17.77 dBW/kg




                                                                                                               Plot No. 4


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

GSM 1900

Frequency: 1909.8 MHz; Duty Cycle: 1:2.60016;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1910 MHz; σ = 1.595 S/m; εr = 53.051; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Front/GPRS_3 slots_ch 810 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.168 W/kg

Front/GPRS_3 slots_ch 810 15mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 10.42 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.205 W/kg
SAR(1 g) = 0.139 W/kg; SAR(10 g) = 0.093 W/kg




                      0 dB = 0.168 W/kg = -7.75 dBW/kg




                                                                                                               Plot No. 5


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

GSM 1900

Frequency: 1909.8 MHz; Duty Cycle: 1:2.60016;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1910 MHz; σ = 1.595 S/m; εr = 53.051; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Front/GPRS_3 slots_ch 810 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.332 W/kg

Front/GPRS_3 slots_ch 810 10mm/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 14.74 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.491 W/kg
SAR(1 g) = 0.291 W/kg; SAR(10 g) = 0.170 W/kg
Maximum value of SAR (measured) = 0.358 W/kg




                      0 dB = 0.358 W/kg = -4.46 dBW/kg




                                                                                                               Plot No. 6


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

W-CDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.443 S/m; εr = 38.677; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.43, 8.43, 8.43); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Touch_RMC Rel.99 ch 9400/Area Scan (7x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.418 W/kg

LHS/Touch_RMC Rel.99 ch 9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 16.81 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.534 W/kg
SAR(1 g) = 0.342 W/kg; SAR(10 g) = 0.215 W/kg
Maximum value of SAR (measured) = 0.422 W/kg




                      0 dB = 0.422 W/kg = -3.75 dBW/kg




                                                                                                               Plot No. 7


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-28

W-CDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.568 S/m; εr = 53.138; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Rear/Rel.99_ch 9400 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.441 W/kg

Rear/Rel.99_ch 9400 15mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.06 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 0.542 W/kg
SAR(1 g) = 0.372 W/kg; SAR(10 g) = 0.250 W/kg
Maximum value of SAR (measured) = 0.444 W/kg




                      0 dB = 0.444 W/kg = -3.53 dBW/kg




                                                                                                               Plot No. 8


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-28

W-CDMA Band II

Frequency: 1880 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                3
Medium parameters used: f = 1880 MHz; σ = 1.568 S/m; εr = 53.138; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(8.03, 8.03, 8.03); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Rear/Rel.99_ch 9400 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.506 W/kg

Rear/Rel.99_ch 9400 10mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 17.87 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 0.714 W/kg
SAR(1 g) = 0.401 W/kg; SAR(10 g) = 0.230 W/kg
Maximum value of SAR (measured) = 0.505 W/kg




                      0 dB = 0.505 W/kg = -2.97 dBW/kg




                                                                                                               Plot No. 9


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-27

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.905 S/m; εr = 42.417; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_RMC Rel.99 ch 4183/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.211 W/kg

RHS/Touch_RMC Rel.99 ch 4183/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 15.92 V/m; Power Drift = -0.07 dB
Peak SAR (extrapolated) = 0.239 W/kg
SAR(1 g) = 0.190 W/kg; SAR(10 g) = 0.145 W/kg
Maximum value of SAR (measured) = 0.212 W/kg




                      0 dB = 0.212 W/kg = -6.74 dBW/kg




                                                                                                               Plot No. 10


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.992 S/m; εr = 55.035; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/Rel. 99_ch 4183 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.324 W/kg

Rear/Rel. 99_ch 4183 15mm/Zoom Scan (6x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 18.20 V/m; Power Drift = 0.00 dB
Peak SAR (extrapolated) = 0.365 W/kg
SAR(1 g) = 0.286 W/kg; SAR(10 g) = 0.217 W/kg
Maximum value of SAR (measured) = 0.321 W/kg




                      0 dB = 0.321 W/kg = -4.93 dBW/kg




                                                                                                               Plot No. 11


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

W-CDMA Band V

Frequency: 836.6 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.992 S/m; εr = 55.035; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/Rel. 99_ch 4183 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.685 W/kg

Rear/Rel. 99_ch 4183 10mm/Zoom Scan (7x6x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 26.75 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 1.69 W/kg
SAR(1 g) = 0.578 W/kg; SAR(10 g) = 0.223 W/kg
Maximum value of SAR (measured) = 0.680 W/kg




                      0 dB = 0.680 W/kg = -1.67 dBW/kg




                                                                                                               Plot No. 12


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-27

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.905 S/m; εr = 42.419; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.47, 9.47, 9.47); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Right); Type: QD000P40CD; Serial: TP:1855

RHS/Touch_QPSK 1/0_ ch 20525/Area Scan (8x13x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.186 W/kg

RHS/Touch_QPSK 1/0_ ch 20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 14.93 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.213 W/kg
SAR(1 g) = 0.169 W/kg; SAR(10 g) = 0.130 W/kg
Maximum value of SAR (measured) = 0.188 W/kg




                      0 dB = 0.188 W/kg = -7.26 dBW/kg




                                                                                                               Plot No. 13


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-02

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.965 S/m; εr = 55.062; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/QPSK RB 1/0 ch 20525 15mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.337 W/kg

Rear/QPSK RB 1/0 ch 20525 15mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 18.84 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.379 W/kg
SAR(1 g) = 0.300 W/kg; SAR(10 g) = 0.228 W/kg
Maximum value of SAR (measured) = 0.336 W/kg




                      0 dB = 0.336 W/kg = -4.74 dBW/kg




                                                                                                               Plot No. 14


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-02

LTE Band 5

Frequency: 836.5 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                3
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.965 S/m; εr = 55.062; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.85, 9.85, 9.85); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Triple Flat Phantom 5.1C; Type: QD 000 P51 CA; Serial: 1166

Rear/QPSK RB 1/0 ch 20525 10mm/Area Scan (8x14x1): Measurement grid: dx=15mm, dy=15mm
Maximum value of SAR (measured) = 0.675 W/kg

Rear/QPSK RB 1/0 ch 20525 10mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm,
dy=8mm, dz=5mm
Reference Value = 26.81 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.945 W/kg
SAR(1 g) = 0.512 W/kg; SAR(10 g) = 0.274 W/kg
Maximum value of SAR (measured) = 0.680 W/kg




                      0 dB = 0.680 W/kg = -1.67 dBW/kg




                                                                                                               Plot No. 15


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-29

LTE Band 17

Frequency: 710 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 710 MHz; σ = 0.865 S/m; εr = 43.994; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1468; Calibrated: 2018-08-22
- Probe: EX3DV4 - SN7314; ConvF(9.86, 9.86, 9.86); Calibrated: 2018-08-30;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM Phantom CRP v5.0(Middle); Type: QD000P40CD; Serial: TP:1854

RHS(touch)/Touch_QPSK RB 1/0 ch 23790/Area Scan (8x13x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.102 W/kg

RHS(touch)/Touch_QPSK RB 1/0 ch 23790/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 10.90 V/m; Power Drift = 0.01 dB
Peak SAR (extrapolated) = 0.109 W/kg
SAR(1 g) = 0.090 W/kg; SAR(10 g) = 0.071 W/kg
Maximum value of SAR (measured) = 0.0993 W/kg




                      0 dB = 0.0993 W/kg = -10.03 dBW/kg




                                                                                                               Plot No. 16


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-25

LTE Band 17

Frequency: 710 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 710 MHz; σ = 0.981 S/m; εr = 54.536; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(10.26, 10.26, 10.26); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Rear_15mm/QPSK RB 1/0 Ch 23790 15 mm/Area Scan (8x14x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.283 W/kg

Rear_15mm/QPSK RB 1/0 Ch 23790 15 mm/Zoom Scan (5x6x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 17.21 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 0.312 W/kg
SAR(1 g) = 0.257 W/kg; SAR(10 g) = 0.204 W/kg
Maximum value of SAR (measured) = 0.284 W/kg




                      0 dB = 0.284 W/kg = -5.47 dBW/kg




                                                                                                               Plot No. 17


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-25

LTE Band 17

Frequency: 710 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                               3
Medium parameters used: f = 710 MHz; σ = 0.981 S/m; εr = 54.536; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(10.26, 10.26, 10.26); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V5.0 (20deg probe tilt)_20190207; Type: QD OVA 001 BB; Serial: 1212

Rear_10mm/QPSK RB 1/0 Ch 23790 10 mm/Area Scan (8x14x1): Measurement grid: dx=15mm,
dy=15mm
Maximum value of SAR (measured) = 0.358 W/kg

Rear_10mm/QPSK RB 1/0 Ch 23790 10 mm/Zoom Scan (5x5x7)/Cube 0: Measurement grid:
dx=8mm, dy=8mm, dz=5mm
Reference Value = 18.01 V/m; Power Drift = -0.11 dB
Peak SAR (extrapolated) = 0.487 W/kg
SAR(1 g) = 0.268 W/kg; SAR(10 g) = 0.156 W/kg
Maximum value of SAR (measured) = 0.338 W/kg




                      0 dB = 0.338 W/kg = -4.71 dBW/kg




                                                                                                           Plot No. 18


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-27

LTE Band 41

Frequency: 2636.5 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                 3
Medium parameters used (interpolated): f = 2636.5 MHz; σ = 1.938 S/m; εr = 37.451; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(7.45, 7.45, 7.45); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

RHS(Touch)/Touch_QPSK RB 1/0_ch 41055/Area Scan (9x16x1): Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 0.137 W/kg

RHS(Touch)/Touch_QPSK RB 1/0_ch 41055/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 9.228 V/m; Power Drift = 0.14 dB
Peak SAR (extrapolated) = 0.274 W/kg
SAR(1 g) = 0.122 W/kg; SAR(10 g) = 0.064 W/kg
Maximum value of SAR (measured) = 0.167 W/kg




                      0 dB = 0.167 W/kg = -7.77 dBW/kg




                                                                                                            Plot No. 19


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-25

LTE Band 41

Frequency: 2636.5 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                 3
Medium parameters used (interpolated): f = 2636.5 MHz; σ = 2.238 S/m; εr = 51.097; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn912; Calibrated: 2018-11-16
- Probe: EX3DV4 - SN7376; ConvF(7.49, 7.49, 7.49); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V6.0 (20deg); Type: QD OVA 003 AA; Serial: 2013

Front(15mm)/QPSK RB 1/0 ch 41055 15mm/Area Scan (10x17x1): Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 0.197 W/kg

Front(15mm)/QPSK RB 1/0 ch 41055 15mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 9.307 V/m; Power Drift = 0.03 dB
Peak SAR (extrapolated) = 0.295 W/kg
SAR(1 g) = 0.145 W/kg; SAR(10 g) = 0.073 W/kg
Maximum value of SAR (measured) = 0.196 W/kg




                      0 dB = 0.196 W/kg = -7.08 dBW/kg




                                                                                                            Plot No. 20


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-03-25

LTE Band 41

Frequency: 2636.5 MHz; Duty Cycle: 1:1.59956;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                                 3
Medium parameters used (interpolated): f = 2636.5 MHz; σ = 2.238 S/m; εr = 51.097; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn912; Calibrated: 2018-11-16
- Probe: EX3DV4 - SN7376; ConvF(7.49, 7.49, 7.49); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V6.0 (20deg); Type: QD OVA 003 AA; Serial: 2013

Rear(10mm)/QPSK RB 1/0 ch 41055 10mm/Area Scan (10x17x1): Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 0.357 W/kg

Rear(10mm)/QPSK RB 1/0 ch 41055 10mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid:
dx=5mm, dy=5mm, dz=5mm
Reference Value = 12.66 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.596 W/kg
SAR(1 g) = 0.284 W/kg; SAR(10 g) = 0.133 W/kg
Maximum value of SAR (measured) = 0.394 W/kg




                      0 dB = 0.394 W/kg = -4.05 dBW/kg




                                                                                                            Plot No. 21


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                               3
Medium parameters used (interpolated): f = 2462 MHz; σ = 1.822 S/m; εr = 39.146; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(7.64, 7.64, 7.64); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Touch_802.11 b mode ch 11 Ant 1/Area Scan (9x17x1): Measurement grid: dx=12mm,
dy=12mm
Maximum value of SAR (measured) = 0.108 W/kg

LHS/Touch_802.11 b mode ch 11 Ant 1/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 7.736 V/m; Power Drift = -0.09 dB
Peak SAR (extrapolated) = 0.189 W/kg
SAR(1 g) = 0.078 W/kg; SAR(10 g) = 0.036 W/kg
Maximum value of SAR (measured) = 0.114 W/kg




                      0 dB = 0.114 W/kg = -9.43 dBW/kg




                                                                                                               Plot No. 22


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                               3
Medium parameters used (interpolated): f = 2462 MHz; σ = 2.023 S/m; εr = 51.477; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn912; Calibrated: 2018-11-16
- Probe: EX3DV4 - SN7376; ConvF(7.5, 7.5, 7.5); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V6.0 (20deg); Type: QD OVA 003 AA; Serial: 2013

Rear/802.11 b mode ch 11 15mm/Area Scan (17x9x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.0626 W/kg

Rear/802.11 b mode ch 11 15mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 5.954 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 0.105 W/kg
SAR(1 g) = 0.051 W/kg; SAR(10 g) = 0.023 W/kg
Maximum value of SAR (measured) = 0.0700 W/kg




                      0 dB = 0.0700 W/kg = -11.55 dBW/kg




                                                                                                               Plot No. 23


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

Wi-Fi 2.4 GHz

Frequency: 2462 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                               3
Medium parameters used (interpolated): f = 2462 MHz; σ = 2.023 S/m; εr = 51.477; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn912; Calibrated: 2018-11-16
- Probe: EX3DV4 - SN7376; ConvF(7.5, 7.5, 7.5); Calibrated: 2018-09-26;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI V6.0 (20deg); Type: QD OVA 003 AA; Serial: 2013

Rear/802.11 b mode ch 11 10mm/Area Scan (17x9x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.156 W/kg

Rear/802.11 b mode ch 11 10mm/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 9.142 V/m; Power Drift = 0.19 dB
Peak SAR (extrapolated) = 0.276 W/kg
SAR(1 g) = 0.120 W/kg; SAR(10 g) = 0.050 W/kg
Maximum value of SAR (measured) = 0.172 W/kg




                      0 dB = 0.172 W/kg = -7.64 dBW/kg




                                                                                                               Plot No. 24


Test Laboratory: UL Korea, Ltd. Suwon Laboratory                                            Date: 2019-04-01

Bluetooth

Frequency: 2441 MHz; Duty Cycle: 1:1.29033;     Room Ambient Temperature: 23.0C; Liquid Temperature: 22.0C
                                                                                               3
Medium parameters used (interpolated): f = 2441 MHz; σ = 1.805 S/m; εr = 39.183; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1259; Calibrated: 2018-07-26
- Probe: EX3DV4 - SN3991; ConvF(7.64, 7.64, 7.64); Calibrated: 2018-05-24;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V5.0 (30deg probe tilt)_20181018; Type: QD 000 P40 CD; Serial: 1829

LHS/Tilt__bluetooth_GFSK_ch 39/Area Scan (9x17x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.0979 W/kg

LHS/Tilt__bluetooth_GFSK_ch 39/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 7.607 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.173 W/kg
SAR(1 g) = 0.068 W/kg; SAR(10 g) = 0.027 W/kg
Maximum value of SAR (measured) = 0.104 W/kg




                      0 dB = 0.104 W/kg = -9.83 dBW/kg




                                                                                                           Plot No. 25



Document Created: 2019-04-11 14:47:24