Test Report

FCC ID: A3DCD-3010A

Test Report

Download: PDF
FCCID_17692

                  PCTEST Engineering Laboratory, Inc.
                              6660-B Dobbin Road • Columbia, MD 21045 • U.S.A.
                               TEL (410) 290-6652 • FAX (410) 290-6654
                                        http://www.pctestlab.com

                                      CERTIFICATE OF COMPLIANCE
NEC Technologies, Inc.                                                       Dates of Tests: December 21-22, 1998
1250 N. Arlington Heights Rd., Suite 500                                     Test Report S/N: B.981221854.A3D
Itasca, IL 60143-1248                                                        Test Site: PCTEST Lab, Columbia MD
Attention: Amin Fatani, Senior Engineer


         FCC ID                         A3DCD-3010A

         APPLICANT                      NEC TECHNOLOGIES, INC.


         Rule Part(s):                   FCC Part 15 Subpart B
         Equipment Class:                Class B Peripheral Device (JBP)
         EUT Type:                       SCSI Device - Internal CD-ROM Reader
         Data Transfer Rate:             6000 Kbytes/sec. (40x speed)
         Trade Name:                     NEC©
         Model:                          CD-3010A

This equipment has been shown to be capable of compliance with the applicable technical standards as
indicated in the measurement report and was tested in accordance with the measurement procedures
specified is ANSI C63.4-1992 (Note Codes: #37).

I attest to the accuracy of data. All measurements reported herein were performed by me or were made
under my supervision and are correct to the best of my knowledge and belief. I assume full responsibility
for the completeness of these measurements and vouch for the qualifications of all persons taking them.

PCTEST certifies that no party to this application has been denied the FCC benefits pursuant to Section 5301 of the Anti-Drug
Abuse Act of 1988, 21 U.S.C. 853(a)




© 1998 PCTEST Engineering Lab., Inc.                                                                       Lab Code 100431-0


                 TABLE OF CONTENTS

         ATTACHMENT A:     COVER LETTER(S)
         ATTACHMENT B:     ATTESTATION STATEMENT(S)
         ATTACHMENT C:     TEST REPORT
             SCOPE                                              1
             INTRODUCTION (SITE DESCRIPTION)                    2
             PRODUCTION INFORMATION                             3
             DESCRIPTION OF TESTS (CONDUCTED)                   4
             DESCRIPTION OF TESTS (RADIATED)                    5
             LIST OF SUPPORT EQUIPMENT                          6
             TEST DATA (CONDUCTED)                              7
             TEST DATA (RADIATED)                               8
             SAMPLE CALCULATIONS                                9
             ACCURACY OF MEASUREMENT                           10
             LIST OF TEST EQUIPMENT                            11
             TEST SOFTWARE USED                                12
             RECOMMENDATION / CONCLUSION                       13
         ATTACHMENT D:     TEST PLOTS
         ATTACHMENT E:     FCC ID LABEL & LOCATION
         ATTACHMENT F:     BLOCK DIAGRAM(S)
         ATTACHMENT G:     SCHEMATIC DIAGRAM(S)
         ATTACHMENT H:     TEST SETUP PHOTOGRAPHS
         ATTACHMENT I:     EXTERNAL PHOTOGRAPHS
         ATTACHMENT J:     INTERNAL PHOTOGRAPHS
         ATTACHMENT K:     USER’S MANUAL




© 1998                   PCTEST Engineering Laboratory, Inc.   FCC Class B


Test Report S/N: B.981221854.A3D                                                           FCC Class B
Dates of Tests: December 21-22, 1998                                                       Certification




                 PRODUCT EVALUATION REPORT




      Scope - Measurement and determination of electromagnetic emissions (EME) of radio frequency
      devices including intentional and/or unintentional radiators for compliance with the technical rules
      and regulations of the Federal Communications Commission.


        Company Name:                   NEC TECHNOLOGIES, INC.
                                        Personal Display Division
        Address:                        1250 N. Arlington Heights Road, Suite 500
                                        Itasca, IL 60143-1248
        Attention:                      Amin Fatani – Senior Engineer
                                        Compliance Engineering Department


       •   FCC ID:                      A3DCD-3010A
       •   Class:                       B Digital Device / Peripheral (JBP)
       •   EUT Type:                    Internal SCSI CD-ROM Reader
       •   Trade Name:                  NEC®
       •   Model:                       CD-3010A
       •   Max. Data Transfer Rate: 6000 Kbytes/sec. (40x speed)
       •   Osc./Crystal(s):             33.86MHz, 16.93MHz
       •   Cable(s):                    Unshielded SCSI ribbon cable (internal)
       •   Rule Part(s):                FCC Part 15 Subpart B
       •   Test Procedure(s):           ANSI C63.4 (1992)
       •   Dates of Tests:              December 21-22, 1998
       •   Place of Tests:              PCTEST Lab, Columbia, MD
       •   Test Report S/N:             B.981221854.A3D



      NOTE: The NEC Model CD-3010A internal SCSI CD-ROM Reader was tested with the
      internal terminator enabled.



                                                                                        Lab Code 100431-0




© 1998 PCTEST Lab                      FCC ID: A3DCD-3010A                                         1
                                 NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                           FCC Class B
Dates of Tests: December 21-22, 1998                                                       Certification



1.1 INTRODUCTION

The measurement procedure described in American National Standard for Methods of Measurement of Radio-
Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9kHz to 40GHz (ANSI
C63.4-1992) was used in determining radiated and conducted emissions emanating from NEC Internal SCSI
CD-ROM Reader FCC ID: A3DCD-3010A.
These measurement tests were conducted at PCTEST Engineering Laboratory, Inc. facility in New Concept
Business Park, Guilford Industrial Park, Columbia, Maryland. The site address is 6660-B Dobbin Road,
Columbia, MD 21045. The test site is one of the highest points in the Columbia area with an elevation of 390
feet above mean sea level. The site coordinates are 39° 11'15" N latitude and 76° 49'38" W longitude. The
facility is 1.5 miles North of the FCC laboratory, and the ambient signal and ambient signal strength are
approximately equal to those of the FCC laboratory. There are no FM or TV transmitters within 15 miles of the
site. The detailed description of the measurement facility was found to be in compliance with the requirements
of § 2.948 according to ANSI C63.4 on October 19, 1992.


1.2 PCTEST Location

The map at right shows the
location of the PCTEST
Lab, its proximity to the
FCC Lab, the Columbia
vicinity area, the
Baltimore-Washington
International (BWI) airport,
and the city of Baltimore,
and the Washington, D.C.
area. (see Figure1).




                                         Figure 1. Map of the Greater Baltimore and Metropolitan
                                                         Washington, D.C. area.

© 1998 PCTEST Lab                       FCC ID: A3DCD-3010A                                     2
                                  NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                       FCC Class B
Dates of Tests: December 21-22, 1998                                                   Certification




 2.1 Product Information

    2.2 Equipment Description

The Equipment Under Test (EUT) is the NEC (Model: CD-3010A) Internal SCSI CD-ROM Reader
FCC ID: A3DCD-3010A. The EUT is a forty-speed SCSI CD-ROM Reader unit compatible with
Compact Disc formats such as Music CDs, Kodak Multi-session Photo CD™ & Single-session Photo
CD™.

Crystal/Oscillator(s):         33.86MHz, 16.93MHz
User Data Capacity:            656 Mbytes/disc (Mode 1)
                               748 Mbytes/disc (Mode 2)
Total No. of Blocks:           336 Kblocks/disc (Maximum)
User Data Blocks:              2048 bytes/block (Mode 1 & Mode 2, Form 1)
                               2336 bytes/block (Mode 2)
                               2328 bytes/block (Mode 2 Form 2)
Data Transfer Rate:            2550 Kbytes/sec. (inner side of disc)
                               6000 Kbytes/sec. (outer side of disc)
Burst Transfer Rate:           20M bytes/sec. (Sync)
                               5M bytes/sec. (A Sync)
Access Time:                   85msec (1/3 Stroke read, average)
Memory Buffer:                 256 Kbytes
Sampling Frequency:            44.1 kHz
Quantifying Bit Number:        16-bit linear
S/N Ratio:                     80 dB
No. of Channels:               2 channels
Front Panel Feature(s):        Headphone Stereo Mini-jack, VOLUME (headphone) Control, BUSY
                               Indicator, Tray Panel, Emergency Eject Hole, Load/Eject Button
Rear Panel (Internal):         Jumper Blocks, Line Out connector, 50-pin SCSI connector, Power connector
Power Supply:                  5V 1.2A, 12V 1.0A
Interface Cable(s):            Unshielded SCSI ribbon cable (internal)
Dimensions (WxHxD):            148 x 420 x 208 mm
Weight:                        0.93 kg


   2.4 EMI Suppression Device(s)
EMI suppression device(s) added and/or modified during testing:
          •   none




© 1998 PCTEST Lab                     FCC ID: A3DCD-3010A                                   3
                                NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                           FCC Class B
Dates of Tests: December 21-22, 1998                                                       Certification



                                     3.1 Description of Tests

                                        3.2 Conducted Emissions

                                     The line-conducted facility is located inside a 16'x20'x10' shielded
                                     enclosure. It is manufactured by Ray Proof Series 81 (see Figure 2).
     Figure 2. Shielded Enclosure    The shielding effectiveness of the shielded room is in accordance
     Line-Conducted Test Facility    with MIL-Std-285 or NSA 65-6. A 1m. x 1.5m. wooden table 80cm.
                                     high is placed 40cm. away from the vertical wall and 1.5m away
                                     from the side wall of the shielded room (see Figure 3).            Solar
                                     Electronics and EMCO Model 3725/2 (10kHz-30MHz) 50Ω/50µH
                                     Line-Impedance Stabilization Networks (LISNs) are bonded to the
                                     shielded room (see Figure 4). The EUT is powered from the Solar
                                     LISN and the support equipment is powered from the EMCO LISN.
                                     Power to the LISNs are filtered by a high-current high-insertion loss
                                     Ray Proof power line filters (100dB 14kHz-10GHz). The purpose of
                                     the filter is to attenuate ambient signal interference and this filter is
                                     also bonded to the shielded enclosure. All electrical cables are
                                     shielded by braided tinned copper zipper tubing with inner
     Figure 3. Line Conducted
       Emission Test Set-Up          diameter of 1/2". If the EUT is a DC-powered device, power will be
                                     derived from the source power supply it normally will be powered
                                     from and this supply lines will be connected to the Solar LISN. LISN
                                     schematic diagram is shown in Figure 5. All interconnecting cables
                                    more than 1 meter were shortened by non-inductive bundling
                                    (serpentine fashion) to a 1-meter length. Sufficient time for the EUT,
                                    support equipment, and test equipment was allowed in order for
                                    them to warm up to their normal operating condition. The RF output
    Figure 4. Wooden Table &        of the LISN was connected to the spectrum analyzer to determine
          Bonded LISNs              the frequency producing the maximum EME from the EUT. The
                                    spectrum was scanned from 450kHz to 30MHz with 20 msec. sweep
                                    time.         The frequency producing the maximum level was
                                    reexamined using EMI/ Field Intensity Meter and Quasi-Peak
                                    adapter. The detector function was set to CISPR quasi-peak mode.
                                    The bandwidth of the receiver was set to 10 kHz. The EUT, support
                                    equipment, and interconnecting cables were arranged and
                                    manipulated to maximize each EME emission. Each emission was
                                    maximized by: switching power lines; varying the mode of operation
                                    or resolution; clock or data exchange speed; scrolling H pattern to
                                    the EUT and/or support equipment, and powering the monitor from
                                    the floor mounted outlet box and the computer aux AC outlet, if
                                    applicable; whichever determined the worst-case emission.
                                    Photographs of the worst-case emission can be seen in Appendix C.
                                    Each EME reported was calibrated using the HP8640B signal
                                    generator.
     Figure 5. LISN Schematic
              Diagram


© 1998 PCTEST Lab                         FCC ID: A3DCD-3010A                                    4
                                    NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                      FCC Class B
Dates of Tests: December 21-22, 1998                                                  Certification



                               3.1 Description of Tests (continued)

                                  3.3 Radiated Emissions

                               Preliminary measurements were made indoors at 1 meter using
                               broadband antennas, broadband amplifier, and spectrum analyzer to
                               determine the frequency producing the maximum EME. Appropriate
 Figure 6. 3-Meter Test Site   precaution was taken to ensure that all EME from the EUT were
                               maximized and investigated. The system configuration, clock speed,
                               mode of operation or video resolution, turntable azimuth with respect
                               to the antenna were noted for each frequency found. The spectrum was
                               scanned from 30 to 200 MHz using biconical antenna and from 200 to
                               1000 MHz using log-spiral antenna. Above 1 GHz, linearly polarized
                               double ridge horn antennas were used.
                               Final measurements were made outdoors at 3-meter test range using
                               Roberts Dipole antennas or horn antenna (see Figure 6). The test
                               equipment was placed on a wooden and plastic bench situated on a 1.5
                               x 2 meter area adjacent to the measurement area (see Figure 7).
  Figure 7. Dimensions of      Sufficient time for the EUT, support equipment, and test equipment was
     Outdoor Test Site         allowed in order for them to warm up to their normal operating
                               condition. Each frequency found during pre-scan measurements was
                               re-examined and investigated using EMI/Field Intensity Meter and
                               Quasi-Peak Adapter. The detector function was set to CISPR quasi-peak
                               mode and the bandwidth of the receiver was set to 100kHz or 1 MHz
                               depending on the frequency or type of signal.
                               The half-wave dipole antenna was tuned to the frequency found during
                               preliminary radiated measurements. The EUT, support equipment and
                               interconnecting cables were re-configured to the set-up producing the
                               maximum emission for the frequency and were placed on top of a 0.8-
                               meter high non-metallic 1 x 1.5 meter table (see Figure 8). The EUT,
                               support equipment, and interconnecting cables were re-arranged and
  Figure 8. Turntable and      manipulated to maximize each EME emission. The turntable containing
       System Setup
                               the system was rotated; the antenna height was varied 1 to 4 meters and
                               stopped at the azimuth or height producing the maximum emission.
                               Each emission was maximized by: varying the mode of operation or
                               resolution; clock or data exchange speed; scrolling H pattern to the EUT
                               and/or support equipment, and powering the monitor from the floor
                               mounted outlet box and the computer aux AC outlet, if applicable; and
                               changing the polarity of the antenna, whichever determined the worst-
                               case emission. Photographs of the worst-case emission can be seen in
                               Appendix C. Each EME reported was calibrated using the HP8640B
                               signal generator. The Theoretical Normalized Site Attenuation Curves
 Figure 9. Normalized Site
 Attenuation Curves (H&V)
                               for both horizontal and vertical polarization are shown in Figure 9.




© 1998 PCTEST Lab                      FCC ID: A3DCD-3010A                                 5
                                 NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                       FCC Class B
Dates of Tests: December 21-22, 1998                                                   Certification



4.1 Support Equipment Used


       1. NEC Mini-Tower Computer      FCC ID: B7ZA105-MT                     S/N: 5305699UN
           (with on-board video)               1.8 m. unshielded power cord
          OPTI ISA Sound Card          FCC DoC Model: 82C925
          TRANTOR SCSI Host Adapter    FCC ID: IE8T160-F
          NEC Int. CD-ROM Dr. (EUT)    FCC ID: A3DCD-3010A                    S/N: 8Z00001BSSS
                                       0.4 m. unshielded SCSI ribbon cable
                                       0.4 m. unshielded LINE OUT wire


       2. NEC Monitor                  FCC ID: A3DJC-1537VMA                  S/N: 1537001
                                       1.8 m. unshielded AC power cord
                                       1.0 m. shielded D-Sub cable


       3. NEC P3200 Printer            FCC ID: B7ZP3200                       S/N: 562300406
                                       1.8 m. unshielded AC power cord
                                       1.0 m. shielded cable (bundled)


       4. NEC Mouse                    FCC ID: DZL210472                      S/N: LC1141001559
                                       1.6 m. shielded cable


       5. NEC Keyboard                 FCC ID: AQ6-MTN56Z15                   S/N: 60943124
                                       1.8 m. shielded coiled cable


       6. ZOOM Modem                   FCC ID: BDNV34MINI-EXT                 S/N: 3117ZM4X40211
                                       1.8 m. unshielded DC power cord
                                       1.0 m. shielded cables


       7. SONY Earphones               Model: n/a                             1.0 m. unshielded wire




         (See “Attachment H - Test Setup Photographs” for actual system test setup.)




© 1998 PCTEST Lab                     FCC ID: A3DCD-3010A                                    6
                                NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                                 FCC Class B
Dates of Tests: December 21-22, 1998                                                             Certification



    5.1 LINE-CONDUCTED TEST DATA

     5.2 Conducted Emissions

                  (See Data under PLOTS – Attachment D)



NOTES:
1.       All modes of operation were investigated and the worst-case emissions are reported.
2.                                          µV from 450kHz to 30MHz.
         The limit for Class B device is 250µ
3.       Line A = Phase; Line B = Neutral
4.       Deviations to the Specifications:   None




*        All readings are calibrated by HP8640B signal generator with accuracy traceable to the National Institute of
         Standards and Technology (formerly NBS).
**       Measurements using CISPR quasi-peak mode.



© 1998 PCTEST Lab                           FCC ID: A3DCD-3010A                                        7
                                      NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                                                      FCC Class B
Dates of Tests: December 21-22, 1998                                                                                  Certification




    6.1 RADIATED TEST DATA

       6.3.1 Radiated Emissions

     FREQ.            Level*          AFCL**             POL            Height          Azimuth             F/S         Margin***
     (MHz)            (dBm)            (dB)             (H/V)            (m)            (° angle)         (µV/m)          (dB)

      75.3            - 81.5             6.9              V               2.7              60              41.9             - 7.6


      114.7           - 82.0            11.0              H               2.5              20              63.3             - 7.5


      175.4           - 85.2            15.2              V               1.9              10              71.0             - 6.5


      361.6           - 90.0            22.6              V               1.5              190             95.8             - 6.4


      440.8           - 93.0            24.7              V               1.4              180             85.9             - 7.3


      481.6           - 95.0            25.7              V               1.4              10              76.4             - 8.3


                                            Table 1. Radiated Measurements at 3-meters.



                                                            NOTES:
                                                            1. All modes of operation were investigated and the worst-case
                                                            emissions are reported.
                                                            2. The radiated limits are shown on Figure 10. Above 1GHz the limit
                                                            is 500 µV/m.




Figure 10. Limits at 3 meters



*            All readings are calibrated by HP8640B signal generator with accuracy traceable to the National Institute of Standards and
             Technology (formerly NBS).
**           AFCL = Antenna Factor (Roberts dipole) and Cable Loss (30 ft. RG58C/U).
***          Measurements using CISPR quasi-peak mode. Above 1GHz, peak detector function mode is used using a resolution bandwidth
             of 1MHz and a video bandwidth of 1MHz. The peak level complies with the average limit. Peak mode is used with linearly
             polarized horn antenna and low-loss microwave cable.




© 1998 PCTEST Lab                                    FCC ID: A3DCD-3010A                                                     8
                                               NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                          FCC Class B
Dates of Tests: December 21-22, 1998                                      Certification



7.1 Sample Calculations



                                         µV = 20 log 10 (µ
                                       dBµ               µV/m)
                                         µV = dBm + 107
                                       dBµ




   7.2 Example 1:

       @ 20.3 MHz
               Class B limit            = 250 µV = 47.96 dBµV
               Reading                  = - 67.8 dBm (calibrated level)
               Convert to dbµV          = - 67.8 + 107 = 39.2 dBµV
                    (39.2/20)
               10                       = 91.2 µV


               Margin                   = 39.2 - 47.96 = - 8.76

                                        = 8.8 dB below limit



   7.3 Example 2:

       @ 66.7 MHz
               Class B limit            = 100 µV/m = 47.96 dBµV/m
               Reading                  = - 76.0 dBm (calibrated level)
               Convert to dbµV/m        = - 76.0 + 107 = 31.0 dBµV/m
               Antenna Factor + Cable Loss              = 5.8 dB
                                        Total           = 36.8 dBµV/m


               Margin                   = 36.8 - 40.0 = - 3.2

                                        = 3.2 dB below limit




© 1998 PCTEST Lab                      FCC ID: A3DCD-3010A                     9
                                 NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                               FCC Class B
Dates of Tests: December 21-22, 1998                                                           Certification



8.1 Accuracy of Measurement

    8.2 Measurement Uncertainty Calculations:
The measurement uncertainties stated were calculated in accordance with the requirements of NIST Technical
Note 1297 and NIS 81 (1994).

                        Contribution                       Probability           Uncertainty (± dB)
                     (Line Conducted)                      Distribution     9kHz-150MHz       150-30MHz
   Receiver specification                                  Rectangular          1.5               1.5
   LISN coupling specification                             Rectangular          1.5               1.5
   Cable and input attenuator calibration                  Normal (k=2)         0.3               0.5
   Mismatch:    Receiver VRC Γ1 = 0.03
            LISN VRC ΓR = 0.8 (9kHz) 0.2 (30MHz)            U-Shaped              0.2              0.35
           Uncertainty limits 20Log(1 ± Γ1 ΓR)
   System repeatability                                    Std. deviation         0.2              0.05
   Repeatability of EUT                                                            -                 -
   Combined standard uncertainty                             Normal              1.26              1.30
   Expanded uncertainty                                    Normal (k=2)           2.5               2.6

Calculations for 150kHz to 30MHz:
                            m
                                             1.52 + 1.52    0.5
                 uc(y) =   ∑ ui2 ( y ) = ±
                           i =1                   3
                                                         + ( )2 + 0.35 = ±1.298dB
                                                             2
                 U = 2Uc(y) = ±2.6dB

                         Contribution                      Probability           Uncertainties (± dB)
                    (Radiated Emissions)                   Distribution          3m              10 m
    Ambient Signals                                                                -                -
    Antenna factor calibration                             Normal (k=2)         ± 1.0            ± 1.0
    Cable loss calibration                                 Normal (k=2)         ± 0.5            ± 0.5
    Receiver specification                                 Rectangular          ± 1.5             ±1.5
    Antenna directivity                                    Rectangular        + 0.5 / - 0        + 0.5
    Antenna factor variation with height                   Rectangular          ± 2.0            ± 0.5
    Antenna phase centre variation                         Rectangular            0.0            ± 0.2
    Antenna factor frequency interpolation                 Rectangular         ±. 0.25           ± 0.25
    Measurement distance variation                         Rectangular          ± 0.6            ± 0.4
    Site imperfections                                     Rectangular          ± 2.0            ± 2.0
    Mismatch: Receiver VRC Γ1 = 0.2                                             + 1.1
               Antenna VRC ΓR = 0.67 (Bi) 0.3 (Lp)          U-Shaped                             ± 0.5
                                                                                - 1.25
              Uncertainty limits 20Log(1 ± Γ1 ΓR)
    System repeatability                                   Std. Deviation       ± 0.5             ± 0.5
    Repeatability of EUT                                                          -                 -
    Combined standard uncertainty                            Normal         + 2.19 / - 2.21   + 1.74 / - 1.72
    Expanded uncertainty U                                 Normal (k=2)     + 4.38 / - 4.42   + 3.48 / - 3.44

Calculations for 3m biconical antenna. Coverage factor of k=2 will ensure that the level of confidence will be
approximately 95%, therefore:
                 U=2uc(y) = 2 x ±2.19 = ±4.38dB


© 1998 PCTEST Lab                         FCC ID: A3DCD-3010A                                       10
                                    NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                                        FCC Class B
Dates of Tests: December 21-22, 1998                                                                    Certification



9.1 Test Equipment
  9.2 Type                          Model                       Cal. Due Date                S/N
 Microwave Spectrum Analyzer        HP 8566B (100Hz-22GHz)               08/15/99        3638A08713
 Microwave Spectrum Analyzer        HP 8566B (100Hz-22GHz)               04/17/99        2542A11898
 Spectrum Analyzer/Tracking Gen.    HP 8591A (100Hz-1.8GHz)              08/10/99        3144A02458
 Signal Generator*                  HP 8640B (500Hz-1GHz)                08/09/99        2232A19558
 Signal Generator*                  HP 8640B (500Hz-1GHz)                08/09/99        1851A09816
 Signal Generator*                  Rohde & Schwarz (0.1-1000MHz)        09/11/99        894215/012
 Ailtech/Eaton Receiver             NM 37/57A-SL (30-1000MHz)            04/12/99        0792-03271
 Ailtech/Eaton Receiver             NM 37/57A (30-1000MHz)               03/11/99        0805-03334
 Ailtech/Eaton Receiver             NM 17/27A (0.1-32MHz)                09/17/99        0608-03241
 Quasi-Peak Adapter                 HP 85650A                            08/15/99        2043A00301
 Ailtech/Eaton Adapter              CCA-7 CISPR/ANSI QP Adapter          03/11/99        0194-04082
 RG58 Coax Test Cable               No. 167                                              n/a
 Harmonic/Flicker Test System       HP 6841A (IEC 555-2/3)                               3531A00115
 Broadband Amplifier (2)            HP 8447D                                             1145A00470, 1937A03348
 Broadband Amplifier                HP 8447F                                             2443A03784
 Transient Limiter                  HP 11947A (9kHz-200MHz)                       2820A00300
 Horn Antenna                       EMCO Model 3115 (1-18GHz)                            9704-5182
 Horn Antenna                       EMCO Model 3115 (1-18GHz)                            9205-3874
 Horn Antenna                       EMCO Model 3116 (18-40GHz)                           9203-2178
 Biconical Antenna (4)              Eaton 94455/Eaton 94455-1/Singer 94455-1/Compliance Design 1295, 1332, 0355
 Log-Spiral Antenna (3)             Ailtech/Eaton 93490-1                                0608, 1103, 1104
 Roberts Dipoles                    Compliance Design (1 set)
 Ailtech Dipoles                    DM-105A (1 set)                                      33448-111
 EMCO LISN                          3816/2                                               1079
 EMCO LISN                          3816/2                                               1077
 EMCO LISN                          3725/2                                               2009
 Microwave Preamplifier 40dB Gain   HP 83017A (0.5-26.5GHz)                              3123A00181
 Microwave Cables                   MicroCoax (1.0-26.5GHz)
 Ailtech/Eaton Receiver             NM37/57A-SL                                          0792-03271
 Spectrum Analyzer                  HP 8594A                                             3051A00187
 Spectrum Analyzer (2)              HP 8591A                                             3034A01395, 3108A02053
 Modulation Analyzer                HP 8901A                                             2432A03467
 NTSC Pattern Generator             Leader 408                                           0377433
 Noise Figure Meter                 HP 8970B                                             3106A02189
 Noise Figure Meter                 Ailtech 7510                                         TE31700
 Noise Generator                    Ailtech 7010                                         1473
 Microwave Survey Meter             Holaday Model 1501 (2.450GHz)                        80931
 Digital Thermometer                Extech Instruments 421305                            426966
 Attenuator                         HP 8495A (0-70dB) DC-4GHz
 Bi-Directional Coax Coupler        Narda 3020A (50-1000MHz)
 Shielded Screen Room               RF Lindgren Model 26-2/2-0                           6710 (PCT270)
 Shielded Semi-Anechoic Chamber     Ray Proof Model S81                                  R2437 (PCT278)
 Environmental Chamber              Associated Systems Model 1025 (Temperature/Humidity) PCT285

                    * Calibration traceable to the National Institute of Standards and Technology (NIST).




© 1998 PCTEST Lab                          FCC ID: A3DCD-3010A                                              11
                                     NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                           FCC Class B
Dates of Tests: December 21-22, 1998                                                       Certification




10.1 Test Software Used

        10      CLS:COLOR 7,0
        20      FOR I = 1 TO 80
        30      PRINT H;
        40      NEXT I
        50      FOR K= 1 TO 25
        60      LPRINT H;
        70      NEXT K
        80      OPEN COM1:1200,N,8,1,CS0,DS0" FOR OUTPUT AS #1
        90      PRINT#1,ATDT,0123456789"
        100     CLOSE:GOTO 20


NOTE: This is a sample of the basic program used during the test. However, during testing a different software
program may be used; whichever determines the worst-case condition. In addition, the program used also
depends on the number and type of devices being tested.


The EUT was exercised by copying CD Data to the hard drive.




© 1998 PCTEST Lab                       FCC ID: A3DCD-3010A                                    12
                                  NEC Internal SCSI CD-ROM Reader


Test Report S/N: B.981221854.A3D                                                     FCC Class B
Dates of Tests: December 21-22, 1998                                                 Certification




11.1 Recommendation/Conclusion

The data collected shows that the NEC Internal SCSI CD-ROM Reader FCC ID: A3DCD-3010A complies with
15.107 and 15.109 of the FCC Rules. The highest emission observed with a minimum margin to the
specifications was at 16.008 MHz for conducted emissions with a margin of 8.77 dB, and at 361.6 MHz for
radiated emissions with a margin of 6.4 dB.




© 1998 PCTEST Lab                     FCC ID: A3DCD-3010A                                13