SAR report part 2

FCC ID: A2HRCT6A03W

RF Exposure Info

Download: PDF
FCCID_4024173

                                Appendix A:SAR Test Data Plots


Test Laboratory: Huatongwei International Inspection Co., Ltd.,SAR Lab        Date: 9/21/2018

WIFI2.4G-Body

Communication System: UID 0, Generic WIFI (0); Frequency: 2412 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 2412 MHz; σ = 1.966 S/m; εr = 53.058; ρ = 1000 kg/m3
Phantom section: Flat Section
Ambient Temperature:22.7℃;Liquid Temperature:22.3℃;

DASY Configuration:

   l   Probe: EX3DV4 - SN7494; ConvF(8.08, 8.08, 8.08) @ 2412 MHz; Calibrated: 2/26/2018
   l   Sensor-Surface: 1.4mm (Mechanical Surface Detection)
   l   Electronics: DAE4 Sn1549; Calibrated: 4/25/2018
   l   Phantom: ELI V8.0 ; Type: QD OVA 004 AA ; Serial: 2078
   l   DASY52 52.10.1(1476); SEMCAD X 14.6.11(7439)


Rear/CH 1/Area Scan (101x151x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 1.76 W/kg

Rear/CH 1/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 0.9470 V/m; Power Drift = 0.13 dB
Peak SAR (extrapolated) = 2.27 W/kg
SAR(1 g) = 0.955 W/kg; SAR(10 g) = 0.373 W/kg
Maximum value of SAR (measured) = 1.70 W/kg




              0 dB = 1.70 W/kg = 2.30 dBW/kg