A2784 UNIA19082806 Smacat V03 MPE Test Report

FCC ID: 2AUJH-V03

RF Exposure Info

Download: PDF
FCCID_4455883

           FCC MPE TEST REPORT

                      FCC ID: 2AUJH-V03

                    Product: Wireless Car Charger
               Trade Name: N/A
               Model Name: V03
                             V01, V02, V04, V05, V06, V07, V08, V09,
               Serial Model: V10, V11, V12, V13, V14, V15, V16, V17,
                             V18, V19, V20, V21, V22, V23, V24, V25,
                             V26, V27, V28, V29, V30
                Report No.: UNIA19082806FR-02



                              Prepared for
              Shenzhen Smacat Electronic Technology Co., Ltd.

6th Floor, Building A1, Yangbei Industrial Zone, Huangtian Hangcheng, Baoan,
                              Shenzhen, China



                              Prepared by
                Shenzhen United Testing Technology Co., Ltd.

    2F, Annex Bldg, Jiahuangyuan Tech P ark, #365 Baotian 1 Rd, Tiegang
         Community, Xixiang Str, Bao'an District, Shenzhen, China


                                      TEST RESULT CERTIFICATION

Applicant’s name .............. : Shenzhen Smacat Electronic Technology Co., Ltd.
                                              6th Floor, Building A1, Yangbei Industrial Zone, Huangtian
Address ................................ : Hangcheng, Baoan, Shenzhen, China

Manufacture's Name ........ : Shenzhen Smacat Electronic Technology Co., Ltd.
                                              6th Floor, Building A1, Yangbei Industrial Zone, Huangtian
Address ................................ : Hangcheng, Baoan, Shenzhen, China

Product description
Product name ...................... : Wireless Car Charger
Trade Mark ............................ : N/A
                              V03, V01, V02, V04, V05, V06, V07, V08, V09, V10, V11,
Model and/or type reference : V12, V13, V14, V15, V16, V17, V18, V19, V20, V21, V22,
                              V23, V24, V25, V26, V27, V28, V29, V30
                                              FCC KDB 680106 D01 RF Exposure Wireless Charging
Standards ........................... :
                                              Apps v03
This device described above has been tested by Shenzhen United Testing Technology
Co., Ltd., and the test results show that the equipment under test (EUT) is in compliance
with the FCC requirements. And it is applicable only to the tested sample identified in the
report.
This report shall not be reproduced except in full, without the written approval of UNI, this
document may be altered or revised by Shenzhen United Testing Technology Co., Ltd.,
personnel only, and shall be noted in the revision of the document.

Date of Test ......................................... :
Date (s) of performance of tests ............ :             Aug. 28, 2019 ~ Sep. 10, 2019
Date of Issue ........................................ :    Sep. 10, 2019
Test Result............................................ :   Pass




  Prepared by:
                                                                        Bob liao/Editor


  Reviewer:
                                                                    Kahn yang/Supervisor


  Approved & Authorized Signer:
                                                                            Liuze/Manager


Note: For a more detailed features description, please refer to the manufacturer’s specifications or
the User's Manual.

                                                Channel List
              Channel               Frequency(KHz)           Channel               Frequency(MHz)
                01                       125




          The EUT antenna is Coil Antenna. No antenna other than that furnished by the
          responsible party shall be used with the device.


1. SUMMARY OF TEST RESULTS

1.1 Test procedures according to the technical standards:
    FCC KDB 680106 D01 RF Exposure Wireless Charging Apps v03


                                                     FCC CFR 47

         Standard Section                           Test Item                   Judgment         Remark


                                        Electric Field Strength (E) (V/m)        PASS
        FCC CFR 47 part1,
        1.1310 KDB680106
           D01 v03(3)(3)
                                      Magnetic Field Strength (H) (A/m)          PASS




    Compliant with KDB680106 D01 RF Exposure Wireless Charging Apps v03 section 5,b:

    a) Power transfer frequency is less than 1 MHz.

    b) Output power from each primary coil is less than or equal to 15 watts.

    c) The transfer system includes only single primary and secondary coils. This includes charging
    systems that may have multiple primary coils and clients that are able to detect and allow coupling only
    between individual pairs of coils.

    d) Client device is placed directly in contact with the transmitter.

    e) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

    f) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface
    from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.


1.2 MEASUREMENT UNCERTAINTY

   The reported uncertainty of measurement y±U,where expended uncertainty U is based on a
   standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence
   of approximately 95 %。



             No.                                     Item                            Uncertainty

              1               Radiated Measurement (9KHz-30MHz)                        ±2.50dB

              2                                 Temperature                             ±0.5°C

              3                                   Humidity                               ±2%


1.3 Test Instruments


         Description               Brand          Model No.        Frequency Range   Calibrated Until

   Broadband Field Meter          NARDA           NBM-550                 ––         Jan. 01, 2020

    Magnetic Field Meter          NARDA            ELT-400             1–400kHz      Jan. 01, 2020

      Magnetic Probe              NARDA            HF-3061         300kHz–30MHz      Jan. 01, 2020

      Magnetic Probe              NARDA            HF-0191           27–1000MHz      Jan. 01, 2020

   Broadband Field Meter          NARDA           NBM-550                 ––         Jan. 01, 2020

     Electric Field Meter      COMBINOVA          EFM 200            5Hz–400kHz      Jan. 01, 2020

       E-Field Probe              NARDA            EF-0391          100kHz–3GHz      Jan. 01, 2020

       E-Field Probe              NARDA            EF-6091         100MHz–60GHz      Jan. 01, 2020


     NOTE: The calibration interval of the above test instruments is 12 months.


2. MAXIMUM PERMISSIBLE EXPOSURE

2.1 MAXIMUM PERMISSIBLE EXPOSURE

    Limit of Maximum Permissible Exposure

                             Limits for Occupational / Controlled Exposure

                                                                                     Averaging Time
  Frequency Range        Electric Field      Magnetic Field     Power Density (S)
       (MHz)          Strength (E) (V/m)   Strength (H) (A/m)      (mW/ cm²)           |E|²,|H|²or S
                                                                                         (minutes)
       0.3-3.0               614                  1.63                 (100)*                6
       3.0-30              1842 / f              4.89 / f            (900 / f)*              6
      30-300                 61.4                 0.163                   1.0                6
     300-1500                                                          F/300                 6
   1500-100,000                                                           5                  6
                        Limits for General Population / Uncontrolled Exposure

  Frequency Range        Electric Field      Magnetic Field      Power Density (S)    Averaging Time
       (MHz)          Strength (E) (V/m)   Strength (H) (A/m)       (mW/ cm²)          |E|²,|H|²or S
                                                                                         (minutes)
      0.3-1.34               614                  1.63                 (100)*               30
      1.34-30               824/f                 2.19/f             (180 / f)*             30
       30-300                27.5                 0.073                   0.2               30
     300-1500                                                         F/1500                30
   1500-100,000                                                           1                 30


   Note 1: f = frequency in MHz ; *Plane-wave equivalent power density.
         2: For the applicable limit, see FCC 1.1310, 680106 D01 RF Exposure Wireless Charging Apps v03.
         3: Emissions between 100 kHz to 300 kHz should be assessed versus the limits at 300 kHz in Table 1
         of Section 1.1310: 614 V/m and 1.63 A/m. A KDB inquiry is required to determine the applicable
         exposure limits below 100 kHz.




                                               Page 5 / 8


2.2 TEST PROCEDURE

  For devices designed for typical desktop applications, such a wireless charging pads, RF
  exposure evaluation should be at 15 cm surrounding the device and 20 cm above the top
  surface. E and H field strength measurements or numerical modeling may be used to
  demonstrate compliance. Measurements should be made from all sides and the top of the
  primary/client pair at 15 cm surrounding the device and 20 cm above the top surface.


2.3 SET UP




2.4 TEST PHOTO




                                        Page 6 / 8


3. RESULT OF MAXIMUM PERMISSIBLE EXPOSURE

For Full load mode:
E-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (V/m)
 Frequency        Test        Test        Test        Test        Test     Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125         1.22        1.10        1.12           1.16    1.11        307         614

H-Filed Strength at at 15 cm surrounding the device and 20 cm above the top surface (A/m)
 Frequency        Test        Test        Test        Test       Test      Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125         0.17        0.16        0.22           0.18    0.20        0.815       1.63

For Half Load for wrist band mode:
E-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (V/m)
 Frequency        Test        Test        Test        Test        Test     Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125         1.18        1.18        1.16           1.16    1.18        307         614

H-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (A/m)
 Frequency        Test        Test        Test        Test       Test      Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125         0.18        0.16        0.20           0.21    0.22        0.815       1.63




                                           Page 7 / 8


For Half Load for shopped mode:
E-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (V/m)
 Frequency        Test        Test        Test        Test        Test     Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125         1.18        1.16        1.15           1.15    1.16        307         614


H-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (A/m)
 Frequency        Test        Test        Test        Test       Test      Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125         0.16        0.16        0.18           0.18    0.16        0.815       1.63


For No load mode:
E-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (V/m)
 Frequency        Test        Test        Test        Test        Test     Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (V/m) (V/m)
   0.125         1.16        1.18        1.20           1.21    1.18        307         614

H-Filed Strength at 15 cm surrounding the device and 20 cm above the top surface (A/m)
 Frequency        Test        Test        Test        Test       Test      Reference Limits Test
Range (MHz) Position A Position B Position C Position D Position E Limit (A/m) (A/m)
   0.125         0.18        0.18        0.16           0.16    0.18        0.815       1.63


                                ※※※※※※THE END※※※※※※




                                           Page 8 / 8



Document Created: 2019-09-24 14:26:00
Document Modified: 2019-09-24 14:26:00

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC