Users Manual

FCC ID: 2AUF7-M6004

Users Manual

Download: PDF
FCCID_4480295

                                User’s   Manual




RF-M6004                 Reader
  User’s                Manual



Shenzhen Nation RFID Technologe Co,Ltd



                    1


                        User’s   Manual




Welcome you to be the user of

  Nation RFID products!




              2


                                                                                                                User’s              Manual



                                                                        Content
1   Product Overview.......................................................................................................................... 5


     1.1      Product characteristics......................................................................................................5

     1.2      Main uses and scope of application............................................................................. 5

     1.3      environment condition..................................................................................................... 5

     1.4      Shape size............................................................................................................................. 6

2   Demo Operational instructions................................................................................................ 7


     2.1      About Demo Software...................................................................................................... 7

     2.2      Demo System Requirements...........................................................................................7

     2.3      technical terms.................................................................................................................... 7

     2.4      Demonstration software operation...............................................................................8

            2.4.1       Connect Reader....................................................................................................... 8

            2.4.2       Data display area.....................................................................................................9

            2.4.3       Write data................................................................................................................11

            2.4.4       Equipment configuration....................................................................................13

            2.4.5       EPC baseband parameters..................................................................................14

            2.4.6       Antenna Port Power Configuration................................................................. 16

            2.4.7       Frequency Hopping Management...................................................................16

            2.4.8 Equipment Information....................................................................................... 18

3   Packaging and Storage...............................................................................................................20


     3.1      Packaging............................................................................................................................20

     3.2      Storage requirements......................................................................................................20

4   Services and Support................................................................................................................. 21

                                                                         3


                                                                           User’s       Manual




Safety Instructions
    Your safety is extremely important. Read and follow all warnings and cautions in this

document before handling and operating Invengo equipment. You can be seriously injured, and

equipment and data can be damaged if you do not follow the cautions.




Warning
    Any Changes or modifications not expressly approved by the party responsible for
compliance could void the user's authority to operate the equipment.
    This equipment has been tested and found to comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable
protection against harmful interference in a residential installation. This equipment generates uses
and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of
the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
-Consult the dealer or an experienced radio/TV technician for help.
    This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance 20cm
between the radiator & your body.




                                                 4


                                                       User’s    Manual




1     Product Overview

1.1   Product characteristics

    RF-M6004 RF module is a high-performance RFID module designed and
developed by Nation RFID. It is equipped with four SMA antenna interfaces.
It has the leading reception sensitivity in the industry. The single tag
recognition rate is fast, and the multi-tag processing ability is strong.
At the same time, the reading and writing module adopts independent die
opening, all-aluminium die casting, exquisite appearance, excellent heat
dissipation performance。




1.2   Main uses and scope of application

    RF-M6004 RF module has the characteristics of fast single tag
identification, long tag reading distance and strong multi-tag processing
ability. It is widely used in challenging application fields such as
warehousing, logistics, clothing, production line management, etc. It can
effectively improve the overall work efficiency and reduce the error rate.。




1.3   environment condition

           working temperature:-20℃~+55℃
           Storage temperature:-40℃~+85℃
           Humidity range:5% ~ 95%RH
           Power supply:DC +3.5V~+17V




                                    5


                                              User’s   Manual




1.4   Shape size

      The volume parameters of RF-M6004 RF module are as

follows: : 71.5mm x 52.5mm x 7.2mm




                              6


                                                                                        User’s         Manual




2        Demo Operational instructions

2.1        About Demo Software

     The Demo software is used to set system parameters and perform write/read operation on Nation RFID

RF-M6004 series reader and ISO compliant transponders




2.2        Demo System Requirements

● Supported Operating Systems

Windows Server 2003; Windows XP Service Pack 2; Windows Vista; Windows 7 ; Windows 10

These systems are 64-bit operating system. The USB driver does not support 64- bit OS for the time being..



● Required Software

Windows Installer 3.0 is required. Windows Installer 3.1 or later is

recommended. IE 5.01 or later is required: for installing the .NET Framework.



● Recommended hardware requirements

CPU: Pentium 4 at 1.7 GHz or above

Memory: min. 512MB



2.3        technical terms

TID: Tag identifier

EPC: Electronic product code

RSSI: Received signal strength indicator

LBT: Listen before Talk

DRM: Dense reader mode

Q: Slot count parameters


                                                            7


                                                        User’s    Manual




2.4     Demonstration software operation

2.4.1    Connect Reader

        All functions can be operated only after successful connection.


2.4.1.1 Serial Communication Connection


    Double-click on the icon      to start Demo software. Each icon in the
main interface toolbar is gray to indicate that the reader is not connected
yet. In the “Device Connection” option list, select the communication mode
“RS232 Connection”,“Param”select “COM?” (Selected PC serial slogans)
and select the communication rate “115200” (default value), and click
“Confirm”. as shown in Figure 1.




                          Figure 1: RS232 Selected


   If the connection is successfully established, the icons in the toolbar
are lit up, as shown in Figure 2, indicating that the serial connection is
successful.

                                     8


                                                               User’s   Manual




                       Figure 2: RS232 Successful connection


2.4.2      Data display area


   Click       on the button,The data display area will be displayed, as shown
in Figure 3.




                    Figure 3: Data Display Area Parameter Meaning




                                         9


                                                     User’s    Manual



       Type:Label type:6C、6B、GB Three kinds;
       EPC:EPC Data of Labels;
       TID:TID Data of Labels;
       UserData:User data area;
       ReserveData:Reserved area data, label password data, etc;
       TotalCount:Total number of tag reads;
       ANT1:Number of Reads of Antenna No.1;
       ANT2:Number of Reads of Antenna No.2;
       ANT3:Number of Reads of Antenna No.3;
       ANT4:Number of Reads of Antenna No.4;
       ANT5:Number of Reads of Antenna No.5;
       ANT6:Number of Reads of Antenna No.6;
       ANT7:Number of Reads of Antenna No.7;
       ANT8:Number of Reads of Antenna No.8;
       RSSI:signal intensity;
       Frequency:Current Read Label Frequency Point ;
       Phase:Current read tag phase value;
       ReadTime:Read time.


2.4.2.1 Read EPC


   Clickon    the button , The data display area displays the EPC data
currently read.
   If you want to read EPC data of custom length, see Custom Reading.


2.4.2.2 Read TID


   Clickon    the button,The data display area displays EPC and TID data
currently read to the tag.
   If you want to read TID data of custom length, see Custom Reading.


                                   10


                                                              User’s     Manual



2.4.2.3 STOP


   Click     onthe button,Stop the current card reading operation.



2.4.3      Write data

2.4.3.1 Write EPC data


   Select“Write Card”- > Click          the button to pop up the dialog box in
the main interface,As shown in Figure 4:




                          Figure 4: Write EPC data

   Select a label data that has been read(Data contains TID information),Fill in EPC
data (hexadecimal string) ,Click “Confirm”.


2.4.3.2 Write user data


   The main interface chooses“write card”- > click              the button to pop
up the dialog box, as shown in Figure 5 below.




                                        11


                                                       User’s   Manual




                       Figure 5: Write user data

   Select a label data that has been read (data contains TID information),
fill in user data (16-digit string), and click“Confirm”.




                                   12


                                                        User’s    Manual




2.4.4    Equipment configuration

   The Demo main interface chooses“Device Control”->“Device Configuration”
and pops up the“Device Configuration”dialog box, as shown in Figure 6.




                    Figure 6: Equipment configuration


   The upper left of the window is the serial port parameters. As shown in
Figure 7, click “ Get ” to get the serial port communication baud rate
parameters of the reader, and click“Set”to set the serial port communication
baud rate of the reader. The baud rate is 9600 bps, 19200 bps, 115200 bps,
230400 BPS and 460800 bps. Others do not support it. The default reader is
115200 bps.




                                     13


                                                         User’s   Manual




                      Figure 7: Serial port parameters


2.4.5 EPC baseband parameters

   The upper left of the window is the EPC baseband parameters. As shown
in Figure 8, click“Get”to get the EPC baseband parameters of the reader
and writer. Click“Set”to set reader EPC baseband parameters.




              Figure 8: Baseband parameter configuration




                                     14


                                                        User’s    Manual



    Changing the configuration of baseband parameters can change the actual
effect of reading and writing (it can be reasonably configured according
to the application scenario, but it needs to be operated under the guidance
of our engineers).
   EPC baseband rate provides six choices:
        Tair = 25us, FM0, LHF = 40KHz; intensive reading mode;
        Tair = 25us, Miller 4, LHF = 300KHz; Fast read mode;
        Tari = 25us, Miller 4, LHF = 320KHz; 255/AUTO.
   Session offers four options:
        0;1;2;3.
   Q value provides sixteen choices:
        0/Single label ;1;2;3;4/Multi-label;5;6;7;8;9;10;11;
        12;13;14;15.
   Label search provides three options:
        A-side inventory;
        B-B-side inventory;
        C-A|B-side inventory.




                                    15


                                                         User’s        Manual




2.4.6 Antenna Port Power Configuration

   The antenna power is at the bottom left of the window. As shown in Figure
9, the reader antenna power can be obtained by clicking“Get”. Click“Set”
to set the reader antenna power.




              Figure 9:    Antenna Port Power Configuration

   Check the corresponding antenna port (the external antenna has been
connected), select the corresponding power value from the list of power
values, click Settings, and pop up the prompt box for successful
configuration.



2.4.7 Frequency Hopping Management

    Select frequency hopping in the left menu bar of the RFID configuration,
as shown in Figure 10. Select“FCC902-928MHz”in the“Frequency”drop-down

list as shown in Figure 11, from the left frequency list box, click“            ”

the button and import it into the right list box, then click“Set”to



                                     16


                                                         User’s      Manual



determine。if you want to select the full frequency hopping, click“        ”
                                                                          ,

then click on the right side. The list box shows all the frequencies in this

band. Click“Set”to see Figure 12. If you click“          ”on the right list

box, all frequencies will be cleared.




               Figure 10:     Frequency Hopping Management




            Figure 11:    Selection of working frequency band




                                     17


                                                          User’s   Manual




                 Figure 12:      Frequency point selection



   2.4.8 Equipment Information


   The main interface chooses “Tool” - >“         ”Device Information, as
shown in Figure 13. After clicking on the icon, a “Device Info”pop-up window
appears, as shown in Figure 14.




                    Figure 13:    Equipment Information


                                      18


                                         User’s    Manual




Figure 14:   Equipment Information Bullet Window




                       19


                                                         User’s    Manual




3     Packaging and Storage

3.1    Packaging

    In order to facilitate storage and transportation in the future, the
RF-M6004 RF module is opened and the packaging box and materials are properly
preserved. In addition to the module, the package also includes the
accessories needed for the use of the product. Please confirm whether the
products and accessories are complete according to the product packing list.
If there are any discrepancies or damages, please contact the after-sales
department in time.




3.2    Storage requirements

RF-M6004 RF module long-term storage should have the following conditions:
      ☆ ambient temperature:-40℃~+85℃
      ☆ relative humidity:5% RH~90%RH




                                     20


                                                            User’s   Manual




4     Services and Support

         Shenzhen Nation RFID Technologe Co,Ltd

                               Advising customers

      Our aim is to provide customers with high quality products, follow-up

will continue to optimize and update our products to ensure that our

product performance is in the forefront of similar products. This user

manual will be different from the actual equipment in terms of product

characteristics, composition and design. We will provide corrections in time.

If you fail to provide timely advice, please consult after-sales.

Sales Telephone: 0755-26909366

National Core Material Federation Official Website: www.nationrfid.com

After-sales support: service@nationrfid.com




                                       21


                                                        User’s    Manual




Warranty Notes:


      In order to provide better service, our company randomly attaches a
warranty card, please keep it well, in order to enjoy the proper service.
1、Since the date of purchase, the product has not been dismantled and
repaired in normal operation, and enjoys warranty service within one year.
2、The following conditions are not covered by free maintenance:
      Over the warranty period
      Damage caused by abuse or human activities
      Terminal Damage Caused by Over Vibration of Users in Transportation
3、This product software is upgraded free of charge, and users can get free
training through different scenarios.
4、If the user does not have a warranty card, he or she will charge according
to the circumstances.




                                     22



Document Created: 2019-10-08 11:28:29
Document Modified: 2019-10-08 11:28:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC