RF Exposure

FCC ID: 2ATYV-IF8R

RF Exposure Info

Download: PDF
FCCID_4403894

FCC ID: 2ATYV-IF8R




                         RF Exposure evaluation


 According to 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test
separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g
extremity SAR, where
f(GHz) is the RF channel transmit frequency in GHz
Power and distance are rounded to the nearest mW and mm before calculation
The result is rounded to one decimal place for comparison
Worse case is as below: [2480MHz: 3.099 dBm(2.041mW) output power]
(2.041mW /5mm) ·[√2.480(GHz)]= 0.63<3.0 for 1-g SAR
Then SAR evaluation is not require



Document Created: 2019-08-13 06:00:33
Document Modified: 2019-08-13 06:00:33