RF Exposure

FCC ID: 2ATX3GD-01

RF Exposure Info

Download: PDF
FCCID_4504807

                      EXPOSURE
                      REPORT

                          FCC ID: 2ATX3GD-01


                      Date of issue: Oct. 23, 2019

Report Number:        MTi19092004-4E2


Sample Description:   Intelligent Constant Temperature Wireless Charger


Model(s):             GD-01


Applicant:            GCteq Wireless(Shenzhen) Co., Ltd.


Address:              Room 1316, Building 9B-2, Shenzhen Bay Technology
                      and Ecology Park, Shenzhen, Guangdong, P.R.C


Date of Test:         Oct. 16, 2019 - Oct. 23, 2019




                      Shenzhen Microtest Co., Ltd.
                         http://www.mtitest.com


                                      Table of Contents


  Applicant’s name:           GCteq Wireless(Shenzhen) Co., Ltd.

                              Room 1316, Building 9B-2, Shenzhen Bay Technology
  Address:
                              and Ecology Park, Shenzhen, Guangdong, P.R.C

  Manufacture's name:         TEN PAO ElECTRONICS(HUIZHOU) Co., LTD.

                              Dongjiang Industrial Estate, Shuikou Street, Huizhou City,
  Address:
                              Guangdong Province, P.R.C

  Product name:               Intelligent Constant Temperature Wireless Charger

  Trademark:                  GCteq


  Model name:                 GD-01


  Standard:                   FCC CFR 47 PART 1 , 1.1310


  RF Exposure Procedures:     KDB 680106 D01 RF Exposure Wireless Charging App v03



This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) compliance with the FCC requirements. And it is applicable
only to the tested sample identified in the report.




                Tested by:


                                                Danny Xu                    Oct. 23, 2019


               Reviewed by:


                                                Blue Zheng                  Oct. 23, 2019

              Approved by:

                                                Smith Chen                  Oct. 23, 2019


1 General Information
1.1 Description of EUT

    Product name:                Intelligent Constant Temperature Wireless Charger

    Brand name:                  GCteq

    Model name:
                                 GD-01

    Series model:
                                 N/A

    Deference in serial model:   N/A

    Operation frequency:         110–148 kHz

    Operational mode:            Wireless charging

    Modulation type:             Load modulation

    Antenna type:                Coil Antenna

    Power source:                DC 12V from adapter

    Battery:                     N/A

                                 MODEL: S018BYU1200150

    Adapter information:         INPUT: AC100-240V~50/60Hz 600mA

                                 OUTPUT:5V/9V/12V-3A/2A/1.5A


1.2 Ancillary equipment list
          Equipment                Model                        S/N        Manufacturer

           Adapter                     /                         /               /

               Load                    /                         /               /


1.3 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Radiated emission(150kHz~30MHz)                 ± 2.5 dB
     Radiated emission(30MHz~1GHz)                   ± 4.2 dB
     Radiated emission (above 1GHz)                  ± 4.3 dB
     Temperature                                     ±1 degree
     Humidity                                        ±5%


2 Testing site
   Test Site               Shenzhen Microtest Co., Ltd

                           No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
   Test Site Location
                           Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China

   FCC Registration No.:   448573


3 List of test equipment
 Equipment   Equipment                                 Serial   Calibration
                             Manufacturer     Model                           Due date
 No.         Name                                      No.      date

                             Narda Safety
             Broadband                        NBM-
 MTI-E068                    Test Solutions            D-1699   2019/07/13    2020/07/12
             Field Meter                      520
                             GmbH

                             Narda Safety
 MTI-E069    Probe E-Field                    EF0691   H-0571   2019/07/13    2020/07/12
                             Test Solutions


4 Test Results
4.4 Maximum permissible exposure
4.4.1        Limit


    Frequency          Electric field       Magnetic field            Power             Averaging
   range(MHz)         strength(V/m)         strength(A/m)        density(mW/cm2)      time(minutes)

                           (A) Limits for Occupational/Controlled Exposure
       0.3-3.0              614                 1.63                 *100                    6
       3.0-30             1842/f               4.89/f               *900/f2                  6
       30-300              61.4                0.163                 1.0 6                   6
     300-1500                                                        f/300                   6
   1500-100000                                                         5                     6
                       (B) Limits for General Population/Uncontrolled Exposure
      0.3-1.34              614                 1.63                 *100                   30
      1.34-30              824/f               2.19/f               *180/f2                 30
       30-300              27.5                0.073                  0.2                   30
     300-1500                                                       f/1500                  30
   1500-100000                                                         1                    30
f = frequency in MHz * = Plane-wave equivalent power density

4.4.2        Test Procedures
E and H-field measurements should be made with the center of the probe at a distance of 15 cm
surrounding the device and 20 cm above the top surface of the primary/client pair.

These measurements should be repeated for three different client battery levels, 1%, 50%, and 99%.

Record the test results.

KDB 680106 D01 RF Exposure Wireless Charging App v03:

(1) Power transfer frequency is less than 1MHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging
systems that may have multiple primary coils and clients that are able to detect and allow coupling
only between individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

(6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top
surface from all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE
limit.

Note: The device is in compliance with KDB 680106 D01 RF Exposure Wireless Charging App v03 6
conditions.


4.4.3   Test Setup


                                              Top Side


                                                            Back Side




                     Left Side
                                                                   15cm
                                                                              Field Probe
                                                                 Right Side




                                 Front Side

                                              Bottom Side


4.4.4   Test Result

                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
           <1%             Top                 20          0.417           0.112
           <1%            Bottom               15          0.421           0.110
           <1%              Left               15          0.424           0.114
           <1%             Right               15          0.423           0.108
           <1%             Front               15          0.419           0.105
           <1%             Back                15          0.410           0.116
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.12%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <50%             Top                 20          0.413           0.119
          <50%            Bottom               15          0.407           0.116
          <50%              Left               15          0.413           0.112
          <50%             Right               15          0.416           0.109
          <50%             Front               15          0.417           0.111
          <50%             Back                15          0.422           0.108
                           Limit                             614           1.63

                      Margin Limit (%)                    0.069%          7.30%



                              Maximum permissible Exposure
          Battery                             Test
                        Test sides                      E –field(V/m)   H–field(A/m)
          levels                         distance(cm)
          <99%             Top                 20          0.431           0.120
          <99%            Bottom               15          0.427           0.108
          <99%              Left               15          0.422           0.105
          <99%             Right               15          0.417           0.101
          <99%             Front               15          0.421           0.112
          <99%             Back                15          0.416           0.105
                           Limit                             614           1.63

                      Margin Limit (%)                    0.070%          7.36%


4.4.5   MPE Setup photo




                          ----END OF REPORT----



Document Created: 2019-11-11 12:34:31
Document Modified: 2019-11-11 12:34:31

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC