Test reports

FCC ID: 2ATX3GD-01

Test Report

Download: PDF
FCCID_4504803

                                           Test Report

                                                    FCC ID: 2ATX3GD-01


                                           Date of issue: Oct. 23, 2019

    Report number:                        MTi19092004-4E1


    Sample description:                    Intelligent Constant Temperature Wireless Charger


    Model(s):                              GD-01


    Applicant:                             GCteq Wireless(Shenzhen) Co., Ltd.


    Address:                              Room 1316, Building 9B-2, Shenzhen Bay Technology
                                          and Ecology Park, Shenzhen, Guangdong, P.R.C


    Date of test:                          Oct. 16, 2019 – Oct. 23, 2019




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

Tel:(86-755)88850135            Fax: (86-755) 88850136                    Web: http://www.mtitest.com            E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                                             - Page 2 of 25 -                                     Report No.: MTi19092004-4E1


                                                                  Table of Contents
1       GENERAL INFORMATION ................................................................................................................................. 4
    1.1     FEATURE OF EQUIPMENT UNDER TEST (EUT)................................................................................................................... 4
    1.2     TEST MODE .............................................................................................................................................................. 4
    1.3     EUT TEST SETUP ....................................................................................................................................................... 5
    1.4     ANCILLARY EQUIPMENT .............................................................................................................................................. 5
    1.5     MEASUREMENT UNCERTAINTY ..................................................................................................................................... 5
2       SUMMARY OF TEST RESULT ............................................................................................................................. 6
    2.1     OPERATION CHANNEL LIST ........................................................................................................................................... 6
    2.2     TEST CHANNEL .......................................................................................................................................................... 6
3       TEST FACILITIES AND ACCREDITATIONS ............................................................................................................ 7
    3.1     TEST LABORATORY ..................................................................................................................................................... 7
    3.2     ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7
    3.3     MEASUREMENT UNCERTAINTY...................................................................................................................................... 7
    3.4     TEST SOFTWARE ........................................................................................................................................................ 7
4       LIST OF TEST EQUIPMENT ................................................................................................................................ 8
5       TEST RESULTS .................................................................................................................................................. 9
    5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9
       5.1.1  Standard requirement ................................................................................................................................. 9
       5.1.2  EUT Antenna ............................................................................................................................................... 9
    5.2 CONDUCTED EMISSION ............................................................................................................................................. 10
       5.2.1  Limits ......................................................................................................................................................... 10
       5.2.2  Test Procedures ......................................................................................................................................... 10
       5.2.3  Test Setup .................................................................................................................................................. 10
       5.2.4  Test Result ................................................................................................................................................. 10
    5.3 RADIATED EMISSION ................................................................................................................................................. 15
       5.3.1  Limits ......................................................................................................................................................... 15
       5.3.2  Test Procedures ......................................................................................................................................... 16
       5.3.3  Test Setup .................................................................................................................................................. 17
       5.3.4  Test Result ................................................................................................................................................. 17
    5.4 OCCUPIED BANDWIDTH ............................................................................................................................................ 22
       5.4.1  Test method............................................................................................................................................... 22
       5.4.2  Test result .................................................................................................................................................. 22
6       PHOTOGRAPHS OF THE TEST SETUP............................................................................................................... 23
7       PHOTOGRAPHS OF THE EUT .......................................................................................................................... 25




Tel:(86-755)88850135                    Fax: (86-755) 88850136                                 Web: http://www.mtitest.com                       E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 3 of 25 -                     Report No.: MTi19092004-4E1




                              Test Result Certification
Applicant’s name:                 GCteq Wireless(Shenzhen) Co., Ltd.


                                  Room 1316, Building 9B-2, Shenzhen Bay Technology
Address:
                                  and Ecology Park, Shenzhen, Guangdong, P.R.C


Manufacture's name:               TEN PAO ElECTRONICS(HUIZHOU) Co., LTD.


                                  Dongjiang Industrial Estate, Shuikou Street, Huizhou City, Guangdong
Address:
                                  Province, P.R.C


Product name:                     Intelligent Constant Temperature Wireless Charger


Trademark:                        GCteq


Model name:                       GD-01


Standards:                        FCC Part 15C


Test procedure:                   ANSI C63.10-2013

This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.


                       Tested by:

                                             Danny Xu                                            Oct. 23, 2019


                  Reviewed by:


                                             Blue Zheng                                          Oct. 23, 2019

                   Approved by:

                                             Smith Chen                                          Oct. 23, 2019



Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 4 of 25 -                     Report No.: MTi19092004-4E1

1 GENERAL INFORMATION
1.1 Feature of equipment under test (EUT)

    Product name:                         Intelligent Constant Temperature Wireless Charger

    Model name:                           GD-01

    Model difference:                     N/A

    Operation frequency:                  110–148 kHz

    Modulation type:                      Load modulation

    Antenna type:                         Coil Antenna

    Power supply:                         DC 12V from adapter

    Battery:                              N/A

                                          MODEL: S018BYU1200150
    Adapter information:                  INPUT: AC100-240V~50/60Hz 600mA
                                          OUTPUT:5V/9V/12V-3A/2A/1.5A

1.2 Test mode
To investigate the maximum EMI emission characteristics generates from EUT, the test system was
pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT operation
mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

                          Test mode                                                    Description
                            Mode 1                                                    Charging+TX

Note1: The test modes were carried out for all operation modes. The final test mode of the EUT was
the worst test mode for EMI, and its test data was showed.
Note2: EUT is tested under full load and belongs to the worst mode.




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 5 of 25 -                     Report No.: MTi19092004-4E1




1.3 EUT test setup
See photographs of the test setup in the report for the actual setup and connections between EUT
and support equipment.

1.4 Ancillary equipment
           Equipment                         Model                    S/N                     Manufacturer
             Adapter                            /                       /                              /
               Load                             /                       /                              /

1.5 Measurement Uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Conducted emission(150kHz~30MHz)                            ± 2.5 dB
     Radiated emission(30MHz~1GHz)                               ± 4.2 dB
     Radiated emission (above 1GHz)                              ± 4.3 dB
     Temperature                                                 ±1 degree
     Humidity                                                    ±5%




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 6 of 25 -                     Report No.: MTi19092004-4E1



2 Summary of Test Result
        Item                  FCC Part No.                            Description of Test                      Result

          1                FCC PART 15.203                           Antenna requirement                        Pass

          2                FCC PART 15.207                           Conducted emission                         Pass

          3                FCC PART 15.209                            Radiated emission                         Pass

          4                 FCC Part 15.215                             20dB bandwidth                          Pass


2.1 Operation channel list
Channel List
                       Channel                                           Frequency (kHz)
                         Low                                                  110
                        Middle                                                143
                         High                                                 148

2.2 Test channel
                       Channel                                           Frequency (kHz)
                        Middle                                                143




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 7 of 25 -                     Report No.: MTi19092004-4E1



3 Test Facilities and Accreditations
3.1 Test laboratory

     Test Laboratory                     Shenzhen Microtest Co., Ltd
                                         No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
     Location
                                         Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
     FCC Registration No.:               448573

3.2 Environmental conditions

     Temperature:                      15ºC~35ºC
     Humidity                          20%~75%
     Atmospheric pressure              98kPa~101kPa


3.3 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     RF frequency                                                1 x 10-7
     RF power, conducted                                         ± 1 dB
     Conducted emission(150kHz~30MHz)                            ± 2.5 dB
     Radiated emission(30MHz~1GHz)                               ± 4.2 dB
     Radiated emission (above 1GHz)                              ± 4.3 dB
     Temperature                                                 ±1 degree
     Humidity                                                    ±5%

3.4 Test software
         Software
                                    Manufacturer                            Model                              Version
          Name
                                     Shenzhen JS
     RF Test System                tonscend co., ltd                      JS1120-3                          2.5.77.0418




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 8 of 25 -                       Report No.: MTi19092004-4E1



4 List of test equipment
 Equipment                                   Manufactu                               Serial       Calibration
                  Equipment Name                                   Model                                            Due date
    No.                                         rer                                   No.            date
                                             Rohde&sch
  MTI-E004        EMI Test Receiver                                ESPI7            100314        2019/10/09       2020/10/08
                                               warz
                  TRILOG
                                             schwarabe
  MTI-E006        Broadband                                     VULB 9163          9163-872       2019/10/15       2020/10/14
                                                ck
                  Antenna
                                             Hewlett-Pa                           3113A061
  MTI-E014        amplifier                                        8447D                          2019/10/09       2020/10/08
                                               ckard                                 50
                  Single path vehicle        Schwarzbe
  MTI-E036                                                     NNBM 8124             01175        2019/10/09       2020/10/08
                  AMN(LISN)                     ck
                  Low noise active
                                             Schwarzbe
  MTI-E038        vertical monopole                            VAMP 9243              #565        2019/10/16       2020/10/15
                                                ck
                  antenna
                                             Schwarzbe
  MTI-E039        Biconical antenna                             BBA 9106              #164        2019/10/15       2020/10/14
                                                ck

                  MXG Vector Signal                                                MY49060
  MTI-E041                                      Agilent           N5182A                          2019/04/16       2020/04/15
                  Generator                                                          455
                  ESG Series Analog                                                GB40051
  MTI-E042                                      Agilent           E4421B                          2019/05/21       2020/05/20
                  signal generator                                                   240
                  Thermometer clock
  MTI-E044                                         -               HTC-1                /         2019/04/17       2020/04/16
                  humidity monitor
                  Log Periodic               Schwarzbe
  MTI-E062                                                    VUSLP 9111B             #312        2018/04/11       2020/04/10
                  Antenna                       ck
                  Log Periodic Dipole        ETS-LIND
  MTI-E063                                                         3148B           00224524       2018/04/11       2020/04/10
                  Array Antenna                GREN
  MTI-E065        Amplifier                    EMtrace            RP06A              00117        2019/04/29       2020/04/28
                  PXA Signal                                                       MY51350
  MTI-E071                                      Agilent           N9030A                          2018/10/25       2019/10/24
                  Analyzer                                                           296
                                             Rohde&sch
  MTI-E076        EMI Test Receiver                               ESIB26            100273        2019/04/16       2020/04/15
                                               warz
                  Synthesized                                                     3610A019
  MTI-E078                                      Agilent           83752A                          2019/04/16       2020/04/15
                  Sweeper                                                            57
                                                                                   MY40027
  MTI-E079        DC Power Supply               Agilent           E3632A                          2019/04/16       2020/04/15
                                                                                     695
                  Artificial mains                                                ES391180
  MTI-E093                                      3ctest           LISN J50                         2019/04/16       2020/04/15
                  network                                                            5
                                         Space-Dtro EWLNA0118G
  MTI-E096        Power amplifier                                         1852001    2019/04/29 2020/04/28
                                           niccs            -P40
                                          SOLAR
   MTI-E097     Current Probe            ELECTRO          9207-1          220095-1 2019/04/17 2020/04/16
                                         NICS CO.
                                          SOLAR
   MTI-E098     Loop Sensor              ELECTRO          7334-1          220095-2 2019/04/21 2020/04/20
                                         NICS CO.
 Note: the calibration interval of the above test instruments is 12 or 24 months and the calibrations are
 traceable to international system unit (SI).




Tel:(86-755)88850135          Fax: (86-755) 88850136               Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 9 of 25 -                     Report No.: MTi19092004-4E1

5 Test Results
5.1 Antenna requirement
5.1.1    Standard requirement
15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device

5.1.2    EUT Antenna
The EUT antenna is Coil Antenna. It comply with the standard requirement. In case of replacement
of broken antenna the same antenna type must be used.




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 10 of 25 -                     Report No.: MTi19092004-4E1


5.2 Conducted emission
5.2.1    Limits
For the following equipment, when designed to be connected to the public utility (AC) power line the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies shall not exceed the limits in the following tables. Compliance with the provisions of this
paragraph shall be based on the measurement of the radio frequency voltage between each power
line and ground at the power terminal using a 50 μH/50 ohms line impedance stabilization network
(LISN).

               Frequency                                                Conducted limit (dBμV)
                 (MHz)                                     Quasi-peak                                  Average
                 0.15 -0.5                                   66 - 56 *                                 56 - 46 *
                   0.5 -5                                        56                                        46
                5 -30                               60                               50
Note: the limit of " * " marked band means the limitation decreases linearly with the logarithm of the
frequency in the range.
5.2.2    Test Procedures
The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the
power mains through a line impedance stabilization network (LISN). All other support equipment
powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the
measuring instrument.
Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
forth in the center forming a bundle 30 to 40 cm long.
I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall length
shall not exceed 1 m.
LISN is at least 80 cm from nearest part of EUT chassis.
For the actual test configuration, please refer to the related Item – photographs of the test setup.
5.2.3    Test Setup




5.2.4    Test Result




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


          Microtest
          OM t J                                     — Page 11 of 25 —                      Report No.: MTH19092004—4E1


    EUT                  Intelligent Constant Temperature                    Model Name:               cpo1
                         Wireless Charger
    Pressure:            101kPa                                              Phase:                    L
   Test voltage:         |DC 12V from adapter AC 120V/60Hz                   Test mode:                Mode 1

      60.0        dBuy



     Lo
     to                                                                     FCCPart15 ClassB AC ConductiontOP)
           \
                                                                           FCCPait5 ClasB AC ConductionAVG)
     so
                         3
     an
                                                                                                                         peok
     ao

     2                                                                                                                   ave




          a.150                       as                   (M)                  5                                   sn.ono




                                           Reading      Correct      Measure—
          No. Mk.             Freq.         Level       Factor          ment          Limit        Over
                              MHz           dBuV          dB            dBuV          dBuV           dB          Detector

             1               0.1500         42.65        9.73          52.38         66.00 —13.62                  aP
             2               0.1500         10.49        9.73         20.22          56.00 —35.78                  AVG
             3               0.2900         35.47        9.75         45.22          60.52 —15.30                  QP
             4               0.2900          6.00        9.75          15.75         50.52 —34.77                  AVG
             5               0.5820         34.99        9.89         44.88          56.00 —11.12                  ols
             6               0.5820          1.71        9.89          11.60         46.00 —34.40                  AVG
             7               2.0300         33.99        9.97         43.96          56.00 —12.04                  aP
             8 *             2.0300         28.91        9.97          38.88           46.00      —7.12            AVG
             9               4.6420         31.97      10.04          42.01          56.00 —13.99                  QP
           10                4.6420         26.02      10.04           36.06         46.00        —9.94            AVG
           11            11.8900            28.56      10.25           38.81         60.00 —21.19                  apP
           12            11.8900            21.16      10.25           3141          50.00 —18.59                  AVG




Tel(e—rsssee50 135           Fax: (86—755) seeso136                 Web: hitpfwww mtitest.com           E—mail: mi@51mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


           Microtest
           OM t J                                           — Page 12 of 26 —                       Report No.: MTH19092004—4E1


    EUT                       {/r:[telligent Constant Temperature          Model Name:                  D01
                                 freless Charger
    Pressure:                 101kPa                                       Phase:                       N
                          .   |DC 12V from adapter AC                                    .
   Test voltage:              120V/6O0Hz                                   Test mode:                    Mode 1

         80.0       dBu


     70

     to                                                                           FCCPaitt5 ClarsB AC ConductionOP)


     so                                      4                                   FECPart15)ClasB AC Conduction{AVG)



     40

                                                                                                                              peak
     30


     20
                                                                                                                              lavs

     10


     0


     40

     20
          0.150                         05                      (MHiz)               5                                   30.000




                                                 Reading     Correct      Measure—            _ _
           No. Mk.              Freq.             Level      Factor          ment            Limit        Over
                                 MHz              dBuV         dB            dBuV            dBuV         dB          Detector

                1              0.1500             46.75       9.73          56.48            66.00     —9.52            aP
                2              0.1500             16.40       9.73          26.13            56.00 —29.87               AVG
                3              0.5820             38.16       9.89          48.05            56.00     —7.95            aP
                4              0.5820             12.04       9.89          21.93            46.00 —24.07               AVG
                5              14500              35.97       9.96          45.93            56.00 —10.07               aP
                6 *            14500              31.19       9.96          41.15            46.00     —4.85            AVG
                7              2.3220             35.04       9.98          45.02            56.00 —10.98               aP
                8              2.3220             28.97       9.98          38.95            46.00     —7.05            AVG
                9              5.5100             34.05      10.08          44.13            60.00 —15.87               oP
            10                 5.5100             20.87      10.08          30.95            50.00 —19.05               AVG
            11                24.0820             29.67      10.22          39.89            60.00 —20.11               aP
            12                24.0820             14.36      10.22          24.58            50.00 —25.42               AVG




Tel(Be—7s5)see50 135               Fax: (86—755) 88850136                Web: hitp:www mtitest.com           E—mail: mi@51mtl.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


          Microtest
          m OM t                                     — Page 13 of 25 —                      Report No.: MTi19092004—4E1


    EUT                     Intelligent Constant Temperature                   Model Name:                 cp—01
                            Wireless Charger
    Pressure:                101kPa                                            Phase:                      L
    Test voltage:            DC 12V from adapter AC 240V/60Hz                  |Test mode:                 Mode 1

      sn.0        aguy


     Lo
                                                                            FCCPait15 ClassB AC ConductiontOP)
     so

     u[ plc                                                                FCCPait15 Cla:B AC ConductionAVG)




     Py
     20
                                                                                                                         peok


                                                                                                                         ve




          a.i50                   as                       (Wz)                                                    5.000




                                       Reading         Correct       Measure—
           No. Mk.         Freq.        Level           Factor          ment          Limit         Over
                            MHz          dBuV             dB            dBuV           dBuy           dB         Detector

              1           0.2900        36.45            9.75          46.20          60.52 —14.32                  QP
             2            0.2900        11.79            9.75          21.54          50.52 —28.98                 AVG
             3            0.5820        36.53            9.89          46.42          56.00       —9.58            oP
             4            0.5820        30.62            9.89          40.51          46.00       —5.49            AVG
             5            14500         37.29            9.96          47.25          56.00       —8.75            oP
             6 *          14500         30.90            9.96          40.86          46.00       —5.14            AVG
             7            3.1860        34.72           10.01          44.73          56.00 —11.27                 QP
             8            3.1860        28.40           10.01          38.41          46.00       —7.59            AVG
             9            5.5020        34.21           10.08          44.29          60.00 —15.71                 aP
            10            5.5020        26.99           10.08          37.07          50.00 —12.93                 AVG
            11           27.39040       31.79           10.32          42.11          80.00 —17.89                 QP
            12           27.3940        13.39           10.32          23.71          50.00 —26.29                 AVG




Tel:(86—755)88850 135        Fax: (86—755) seesor36                 Web: hitpiwww.mtitest.com           E—mail: mti@§1mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


          Microtest
          OM t J                                     — Page 14 of 26 —                          Report No.: MTH19092004—4E1


    EUT                   Int_elligent Constant Temperature                Model Name:              D01
                          Wireless Charger
    Pressure:             101kPa                                           Phase:                   N
   Test voltage:          |DC 12V from adapter AC 240V/60Hz                 |Test mode:             Mode 1

      s0.0        aBuy


     Lo
     to                                                                     FCCPart15 ClassB AC ConductiontOP)

                                                                           FCCPait15 ClasB AC ConductionAVG)
     so
                                                                                    8                                   1
     an




     en.


                                                                                                                        z
          a.150                    as                      (Mz)                 5                                    sn.o00



                                        Reading       Correct       Measure—
          No. Mk.          Freq.         Level         Factor          ment             Limit       Over
                           MHz           dBuV            dB            dBuV             dBuV         dB          Detector

             1            0.2940         33.48          9.75          43.23             60.41 ~17.18               P
             2            0.2940          3.15          9.75          13.50             50.41 —36.91               AVG
             3            0.5820         34.86          9.89          44.75             56.00 ~11.25               aP
             4            0.5820         28.52          9.89          38.41             46.00      —7.59           AVG
             5            14500          33.48          9.96          43.44             56.00 —12.56               P
             6+           14500          28.70          9.96          38.66             46.00      —7.34           AVG
             7            2.3220         32.07          9.98          42.05             56.00 —13.95               aP
             8            2.3220         26.26          9.98          36.24             46.00      —9.76           AVG
             9            5.5060         3146          10.08          41.54             60.00 1846                 QP
           10             5.5060         26.08         10.08          36.16             50.00 —13.84               AVG
           1             28.2540         30.58         10.33          40.91             60.00 —19.090              QP
           12            28.2540         10.58         10.33          20.91             50.00 —29.09               AVG




Tel(e—rsssee50 135           Fax: (86—755) seeso136                 Web: hitpfwww mtitest.com           E—mail: mi@51mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


                                                      - Page 15 of 25 -                     Report No.: MTi19092004-4E1




5.3 Radiated emission
5.3.1    Limits
In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in
the table below has to be followed.
             Frequencies                      Field Strength           Measurement Distance
                 (MHz)                      (micorvolts/meter)                  (meters)
             0.009~0.490                       2400/F(KHz)                        300
             0.490~1.705                      24000/F(KHz)                         30
              1.705~30.0                            30                             30
                 30~88                             100                              3
                88~216                             150                              3
               216~960                             200                              3
              Above 960                            500                              3

LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)

                                                                          Class B (dBuV/m) (at 3M)
                FREQUENCY (MHz)
                                                                       PEAK                           AVERAGE
                       Above 1000                                        74                                54
Notes:
  The limit for radiated test was performed according to FCC PART 15C.
  The tighter limit applies at the band edges.
  Emission level (dBuV/m)=20log Emission level (uV/m).

  FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators)

      Highest frequency generated or
     Upper frequency of measurement
                                                                                Range (MHz)
     used in the device or on which the
      device operates or tunes (MHz)
                   Below 1.705                                                         30
                    1.705 – 108                                                      1000
                       108 – 500                                                     2000
                    500 – 1000                                                    5000
                                                         5th   harmonic of the highest frequency or 40 GHz,
                    Above 1000
                                                                          whichever is lower

           Spectrum Parameter                                                   Setting
               Attenuation                                                       Auto
             Start Frequency                                                  1000 MHz
             Stop Frequency                                              10th carrier harmonic
      RB / VB (emission in restricted
                                                      1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average
                   band)

           Receiver Parameter                                              Setting
                Attenuation                                                 Auto
          Start ~ Stop Frequency                                 9kHz~150kHz / RB 200Hz for QP
          Start ~ Stop Frequency                                 150kHz~30MHz / RB 9kHz for QP


Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 16 of 25 -                     Report No.: MTi19092004-4E1

          Start ~ Stop Frequency                             30MHz~1000MHz / RB 120kHz for QP
5.3.2    Test Procedures
a.   The measuring distance of at 3 m shall be used for measurements at frequency up to 25GHz.
     For frequencies above 1GHz, any suitable measuring distance may be used.

b.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
     semi-chamber test. The table was rotated 360 degrees to determine the position of the highest
     radiation.

c.   The height of the equipment or of the substitution antenna shall be 0.8m; above 1GHz, the
     height was 1.5m, the height of the test antenna shall vary between 1 m to 4 m. Both horizontal
     and vertical polarizations of the antenna are set to make the measurement.

d.   The initial step in collecting conducted emission data is a spectrum analyzer peak detector
     mode pre-scanning the measurement frequency range. Significant peaks are then marked and
     then Quasi Peak detector mode re-measured.

e.   If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
     EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
     performed.

f.   For the actual test configuration, please refer to the related Item –EUT Test Photos.

g.   For the radiated emission test above 1GHz:
     Place the measurement antenna away from each area of the EUT determined to be a source of
     emissions at the specified measurement distance, while keeping the measurement antenna
     aimed at the source of emissions at each frequency of significant emissions, with polarization
     oriented for maximum response.

h.   The measurement antenna may have to be higher or lower than the EUT, depending on the
     radiation pattern of the emission and staying aimed at the emission source for receiving the
     maximum signal. The final measurement antenna elevation shall be that which maximizes the
     emissions. The measurement antenna elevation for maximum emissions shall be restricted to a
     range of heights of from 1 m to 4 m above the ground or reference ground plane.

Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three
orthogonal axis. The worst case emissions were reported.




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 17 of 25 -                     Report No.: MTi19092004-4E1




5.3.3    Test Setup
Radiated Emission Test-Up Frequency Below 30MHz




Radiated Emission Test-Up Frequency 30MHz~1GHz




5.3.4    Test Result




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


            Microtest
            OM t J                                   — Page 18 of 25 —                      Report No.: MTH19092004—4E1

Frequency range (9KHz — 3OMHz

   EuT                 Intelligent Constant Temperature                  Model Name:                 cpo1
                       Wireless Charger
   Pressure:           101kPa                                            Test mode:                  Mode 1
   Test voltage:        |DC 12V from adapter AC 120V/60Hz
   130.0      dBu¥/n

   120

   im                                                                              EoC 15 C Mad:               z
   too                                                                                                      in —6 a8

   so

   so

   To

   so

   so

   40

   30

   20
   10.0
      o.o08                                               ns                                                           atso


                                      Reading         Correct        Measure—            _ _
            No. Mk.     Freq.           Level           Factor          ment           Limit        Over
                         MHz             dBuV         dBuV/im          dBuV/im         dBuV/im         dB         Detector

        1              0.0156           39.56          20.33            59.89          123.66       —63.77             peak
        2              0.0241           18.85          20.36            39.21          119.89       —80.68              peak
        3              0.0313           33.77          20.33            54.10          117.63 —63.53                    peak
        4              0.0469           29.06          20.28            49.34          114.12       —64.78             peak
        5              0.0761           30.65          20.05            50.70          109.93       —59.23              peak
        6       °*     0.1454           55.69          19.85            75.54          104.32 —28.78                    peak




Tel(se—rssissssor3s          Fax: (86—755) seesor36                 Web: hitpiwww.mtitest.com           E—mail: mti@§1mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


               Microtest
               OM t J                                — Page 19 of 26 —                        Report No.: MTH19092004—4E1


    EUT                  Intelligent Constant Temperature Wireless                  Model Name:              |GD—01
                         Charger
    Pressure:            101kPa                                                     Test mode:               Mode 1
   Test voltage:         |DC 12V from adapter AC 120V/60Hz

    130.0       dBuW/m

    120

    110
    100                                                                                                                      |

    so                                                                                                                       |

    so                                                                                                                       |
                                                                                    FCC 15 C Radiation Below 1GHz
    To
                                                                                                          Margin —b db
    so

    so

    «o

    2o

    20
    1o.0
       a.t50                      a5                      (MHz)                 5                                        a0.o00




                                       Reading        Correct        Measure—            _ _
               No. Mk.    Freq.         Level          Factor          ment             Limit           Over
                           MHz           dBuV          dBuV/m          dBuV/m            dBuV/m           dB        Detector

         1               0.1500         55.65          19.87            75.52           104.05         —28.53             peak
         2               0.2909         365.71         19.75            55.46            98.32         —42.86            peak
         3               0.4351         34.41          20.04            54.45            94.83         —40.38            peak
         400      *      1.5935         25.73          20.26           45.99             63.59         —17.60            peak
         5               5.8358         22.11          20.08           42.19             69.50         —27.31             peak
         6               16.8387        21.22          20.92           42.14             69.50         —27.36            peak




Tel(se—rssissssor3s          Fax: (86—755) seesor36                 Web: hitpiwww.mtitest.com           E—mail: mti@§1mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


          Microtest
          #om t m                                        — Page 20 of 25 —                    Report No.: MTi19092004—4E1

Frequency range (30MHz — 1GHz

    EUT                     Intelligent Constant Temperature            Model Name:               D01
                            (Wireless Charger
    Pressure:               101kPa                                      Polarization:             Vertical
    Test voltage:           |DC 12V from adapter AC 120V/60Hz |Test mode:                         Mode 1

      80.0     dBi/m


     Lo

     so
                                                                                        FCC Class B 3M Rediation
     so                                                                                                Margin —6 08

     10

     ao

     20




          so.o00       «0    su    60   70 so                tanz)             El       «oo     Soo   sno 700         1000.000



                                           Reading        Correct     Measure—
              No. Mk.         Freq.             Level      Factor       ment          Limit           Over
                                  MHz           dBuV      dBuV/m        dBuV/m        dBuV/im           dB       Detector

          1        *        514807              37 .49     —6.77         30.72          40.00         —9.28              QP
          2                 89.9047             43.59      —9.82         33.77          43.50         —9.73            QP
          3                 168.4138            42.27      —9.61         32.66          43.50         —10.84           OP
          4                 318.8170            30.83      —4.78        26.05           46.00         —19.95             QP
          5                 580.7026            29.81      —0.42        29.39           46.00         —16.61             QP
          6                 909.6667            26.31      3.69          30.00          46.00         —15.00           OP




Tel:(86—755)88850 135        Fax: (86—755) 88850136                 Web: hitpiwww.mtitest.com           E—mail: mti@§1mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


          Microtest
          OM t J                                         — Page 21 of 25 —                    Report No.: MTH19092004—4E1


    EUT                    Intelligent Constant Temperature             Model Name:                   GD—01
                           Wireless Charger
    Pressure:              101kPa                                       Polarization:                 Horizontal
   Test voltage:           |DC 12V from adapter AC 120V/60Hz Test mode:                               Mode 1

      80.0     dBi¥/m


     Lo

     so
                                                                                        FCC Class B 3M Rediation
     so                                                                                                 Margh —6 8B




          soubo       «o    5o     60    70 to               thke)              300     «o0     soo    oon 700        1000.000



                                            Reading        Correct    Measure—
              No. Mk.            Freq.       Level         Factor       ment          Limit           Over
                                 MHz             dBuV     dBuVim        dBuV/m        dBuV/m           dB          Detector

          1                43.5057               26.60     —6.88        19.72         40.00           —20.28           QP
          2                87.7248               33.58     —10.27       23.31         40.00           —16.69           QP
          3       *        1826106               38.96    —10.08        28.88         43.50           —14.62           QP
          4                291.0360              34.56     5.19         29.37         46.00           —16.63          P
          5                443.2943              31.30     —3.01        28.29         46.00           —17.71           QP
          6                833.3171              27.74     2.62         30.36         46.00           —15.64           QP




Tel(se—rssissssor3s          Fax: (86—755) seesor36                 Web: hitpiwww.mtitest.com           E—mail: mti@§1mti.com
Address: No.102A & 3024, East Block, Hengfang Industrial Park, Xingye Road, Xixang, Bac‘an Distrct, Shenzhen, Guangdong, China


                                                      - Page 22 of 25 -                     Report No.: MTi19092004-4E1


5.4 Occupied bandwidth
5.4.1    Test method
Use the following spectrum analyzer settings:
Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
RBW ≥1% of the 20 dB bandwidth
VBW ≥RBW
Sweep = auto
Detector function = peak
Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the marker-delta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99%
occupied bandwidth of the emission.
5.4.2    Test result

                                               20dB emission bandwidth                  99% occupied bandwidth
            Frequency (kHz)
                                                        (kHz)                                   (kHz)
                       143                             8.137                                    6.904

Test plots as below:




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 23 of 25 -                     Report No.: MTi19092004-4E1


6 Photographs of the Test Setup
                                                    Radiated emission




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 24 of 25 -                     Report No.: MTi19092004-4E1



                                                   Conducted emission




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 25 of 25 -                     Report No.: MTi19092004-4E1


7 Photographs of the EUT
See the APPENDIX 1: EUT PHOTOS in the report No.:MTi19092004-4E1-1.


                                              ----END OF REPORT----




Tel:(86-755)88850135         Fax: (86-755) 88850136                Web: http://www.mtitest.com         E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China



Document Created: 2019-11-10 14:05:33
Document Modified: 2019-11-10 14:05:33

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC