Test report BLE

FCC ID: 2ATV2-WMBR-1

Test Report

Download: PDF
FCCID_4394876

                                                  TEST REPORT
Report No…………………………… :                                    CHTEW19070052                  Report verification :
Project No..……………………..….. :                               SHT1906073903EW

FCC ID ............................................. :    2ATV2-WMBR-1

Applicant’s name ........................... :            Walmart, Inc. on behalf of its affiliate Project Franklin, LLC

Address ............................................. :   74 Kent St #2, Brooklyn, NY 11222

Manufacturer.....................................:        Shenzhen ChampOn Technology Co. Ltd

Address..............................................:    628 Yi Ben BLDG, No.1063 Cha Guang rd, Xili, Nanshan,
                                                          Shenzhen

Test item description .................... :              Walmart WiFi Bridge

Trade Mark ....................................... :      Walmart

Model/Type reference ....................... :            WMBR-1

Listed Model(s) ................................. :       -

Standard ......................................... :      FCC CFR Title 47 Part 15 Subpart C Section 15.247

Date of receipt of test sample……....:                     Jul.05, 2019

Date of testing………………………..:                               Jul.05, 2019- Jul.15, 2019

Date of issue………………………....:                               Jul.16, 2019

Result .................. …………………...:                     PASS

Compiled by
( Position+Printed name+Signature) :                      File administrators Echo Wei

Supervised by
( Position+Printed name+Signature) :                      Project Engineer Edward Pan

Approved by
( Position+Printed name+Signature) :                      RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road,
                                                          Tianliao, Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source
of the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will
not assume liability for damages resulting from the reader's interpretation of the reproduced material due
to its placement and context.
The test report merely correspond to the test sample.



                                                                 Page: 1 of 36


Report No.:    CHTEW19070052                   Page:     2 of 36               Issued:    2019-07-16




                                              Contents

1.      TEST ST AN D AR D S AND R E PO RT V E R SIO N                                                      3

1.1.    Test Standards                                                                                 3
1.2.    Report version                                                                                 3

2.      T EST D E S CR I PT IO N                                                                           4

3.      SUM M AR Y                                                                                         5

3.1.    Client Information                                                                             5
3.2.    Product Description                                                                            5
3.3.    Operation state                                                                                6
3.4.    EUT configuration                                                                              6
3.5.    Modifications                                                                                  6

4.      T EST EN V IRO NM ENT                                                                              7

4.1.    Address of the test laboratory                                                                 7
4.2.    Test Facility                                                                                  7
4.3.    Environmental conditions                                                                       8
4.4.    Statement of the measurement uncertainty                                                       8
4.5.    Equipments Used during the Test                                                                9

5.      T EST CO N DIT IO N S AND R E SU LT S                                                          11

5.1.    Antenna Requirement                                                                            11
5.2.    Conducted Emissions (AC Main)                                                                  12
5.3.    Conducted Peak Output Power                                                                    15
5.4.    Power Spectral Density                                                                         16
5.5.    6dB bandwidth                                                                                  18
5.6.    Restricted band                                                                                20
5.7.    Band edge and Spurious Emissions (conducted)                                                   22
5.8.    Spurious Emissions (radiated)                                                                  27

6.      T EST S ET UP PHO T O S                                                                        31

7.      E XT E R AN AL AN D I NT ER N AL P HO T O S                                                    33




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                    Page:   3 of 36               Issued:    2019-07-16



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
FCC Rules Part 15.247: Frequency Hopping, Direct Spread Spectrum and Hybrid Systems that are in
operation within the bands of 902-928 MHz, 2400-2483.5 MHz, and 5725-5850 MHz

ANSI C63.10:2013: American National Standard for Testing Unlicensed Wireless Devices

KDB 558074 D01 15.247 Meas Guidance v05r02: Guidance for Compliance Measurements on Digital
Transmission System, Frequency Hopping Spread Spectrum System, and Hybrid System Devices Operating
under Section 15.247 of The FCC Rules

1.2. Report version
      Revision No.               Date of issue                             Description
          N/A                     2019-07-16                                 Original




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                    Page:     4 of 36                    Issued:     2019-07-16



2. TEST DESCRIPTION
               Test Item                        FCC Rule                     Result              Test Engineer
Antenna requirement                          15.203/15.247(c)                PASS               JiongSheng.Feng
Line Conducted Emissions (AC Main)                15.207                     PASS                  Zhiwei Liu
Conducted Peak Output Power                    15.247(b)(3)                  PASS               JiongSheng.Feng
Power Spectral Density                           15.247(e)                   PASS               JiongSheng.Feng
6dB Bandwidth                                  15.247(a)(2)                  PASS               JiongSheng.Feng
Restricted band                              15.247(d)/15.205                PASS               JiongSheng.Feng
Spurious Emissions                           15.247(d)/15.209                PASS                  Xu Yang

Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                   Page:    5 of 36                   Issued:        2019-07-16



3. SUMMARY
3.1. Client Information
Applicant:                       Walmart, Inc. on behalf of its affiliate Project Franklin, LLC

Address:                         74 Kent St #2, Brooklyn, NY 11222

Manufacturer:                    Shenzhen ChampOn Technology Co. Ltd

Address:                         628 Yi Ben BLDG, No.1063 Cha Guang rd, Xili, Nanshan, Shenzhen


3.2. Product Description
Name of EUT:                     Walmart WiFi Bridge

Trade Mark:                      Walmart

Model No.:                       WMBR-1

Listed Model(s):                 -

Power supply:                    DC 5V

Hardware version:                V2

Software version:                V1

Bluetooth

Version:                         Supported BT5.0+BLE

Modulation:                      GFSK

Operation frequency:             2402MHz~2480MHz

Channel number:                  40

Channel separation:              2MHz

Antenna type:                    FPC

Antenna gain:                    2dBi




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                   Page:    6 of 36                 Issued:    2019-07-16



3.3. Operation state
    Test frequency list
     According to section 15.31(m), regards to the operating frequency range over 10 MHz, must select three
     channel which were tested. the Lowest frequency, the middle frequency, and the highest frequency of
     channel were selected to perform the test, please see the above gray bottom.

                            Channel                                     Frequency (MHz)
                              00                                               2402
                              01                                               2404
                              ...




                                                                                ...
                              19                                               2440
                              ...




                                                                                ...
                              38                                               2478
                              39                                               2480

    Test mode
        For RF test items
        The engineering test program was provided and enabled to make EUT continuous transmit (duty
        cycle>98%).
        For AC power line conducted emissions:
        The EUT was set to connect with the Bluetooth instrument under large package sizes transmission.
        For Radiated suprious emissions test item:
        The engineering test program was provided and enabled to make EUT continuous transmit(duty
        cycle>98%). The EUT in each of three orthogonal axis emissions had been tested ,but only the worst
        case (X axis) data Recorded in the report.


3.4. EUT configuration
    The following peripheral devices and interface cables were connected during the measurement:
    ●   - supplied by the manufacturer
    ○   - supplied by the lab
                                                 Manufacturer:   /
         /
                                                 Model No.:      /
                                                     Manufacturer:   TOSHIBA
    ○     Notebook
                                                     Model No.:      Satellite M800


3.5. Modifications
     No modifications were implemented to meet testing criteria.




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                    Page:    7 of 36                  Issued:    2019-07-16



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
4.2. Test Facility

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No.: 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files.

IC-Registration No.:5377A

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No.: 5377A.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                   Page:     8 of 36                 Issued:    2019-07-16



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba

4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors in calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report according to TR-100028-01 “Electromagnetic
compatibility and Radio spectrum Matters (ERM); Uncertainties in the measurement of mobile radio
equipment characteristics; Part 1” and TR-100028-02 “Electromagnetic compatibility and Radio spectrum
Matters (ERM); Uncertainties in the measurement of mobile radio equipment characteristics; Part 2” and is
documented in the Shenzhen Huatongwei International Inspection Co., Ltd. quality system according to
ISO/IEC 17025. Furthermore, component and process variability of devices similar to that tested may result in
additional deviation. The manufacturer has the sole responsibility of continued compliance of the device.

Here after the best measurement capability for Shenzhen Huatongwei International Inspection Co., Ltd.
is reported:

                      Test Items                           Measurement Uncertainty             Notes
Transmitter power conducted                                          0.51 dB                     (1)
Conducted spurious emissions 9kHz~40GHz                              0.51 dB                     (1)
Conducted Disturbance 150kHz~30MHz                                   3.02 dB                     (1)
Radiated Emissions below 1GHz                                        4.90 dB                     (1)
Radiated Emissions above 1GHz                                        4.96 dB                     (1)
Occupied Bandwidth                                                    70 Hz                      (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
    level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:        CHTEW19070052                  Page:      9 of 36                Issued:          2019-07-16



4.5. Equipments Used during the Test
●      Conducted Emission
                                                                                    Last Cal. Date    Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.         Serial No.
                                                                                    (YY-MM-DD)         (YY-MM-DD)
 ●     Shielded Room         Albatross projects        N/A                N/A        2018/09/28         2023/09/27
 ●     EMI Test Receiver           R&S                 ESCI             101247       2018/10/27         2019/10/26
 ●     Artificial Mains      SCHWARZBECK            NNLK 8121             573        2018/10/27         2019/10/26
 ●     Pulse Limiter               R&S               ESH3-Z2            100499       2018/10/27         2019/10/26
 ●     RF Connection Cable   HUBER+SUHNER             EF400               N/A        2018/11/15         2019/11/14
 ●     Test Software               R&S                ES-K1               N/A            N/A               N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02       20371        2018/10/28         2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02       20373        2018/10/28         2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02       20375        2018/10/28         2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6            100211       2018/10/27         2019/10/26
 ○     V-Network                   R&S               ESH3-Z6            100210       2018/10/27         2019/10/26
 ○     2-Line V-Network            R&S               ESH3-Z5            100049       2018/10/27         2019/10/26

 ●     Radiated Emission-6th test site
                                                                                    Last Cal. Date    Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.         Serial No.
                                                                                    (YY-MM-DD)         (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02             N/A        2018/09/30         2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI             100900       2018/10/28         2019/10/27
 ●     Loop Antenna                R&S               HFH2-Z2            100020       2017/11/20         2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163             546        2017/04/05         2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742             N/A        2018/11/15         2019/11/14
 ●     RF Connection Cable   HUBER+SUHNER              N/A                N/A        2018/09/28         2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104         501184/4      2018/09/28         2019/09/27
 ●     Test Software               R&S                ES-K1               N/A            N/A               N/A
 ●     Turntable             Maturo Germany          TT2.0-1T             N/A            N/A               N/A
 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12           N/A            N/A               N/A

 ●     Radiated emission-7th test site
                                                                                    Last Cal. Date    Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.         Serial No.
                                                                                    (YY-MM-DD)         (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01             N/A        2018/09/30         2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40             100597       2018/10/27         2019/10/26
 ●     Horn Antenna          SCHWARZBECK              9120D              1011        2017/03/27         2020/03/26
 ●     Pre-amplifier              BONN             BLWA0160-2M         1811887       2018/11/14         2019/11/13
 ●     Pre-amplifier                CD               PAP-0102           12004        2018/11/14         2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718          9718-248      2019/04/26         2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH              N/A        2018/11/15         2019/11/14
 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL             N/A        2018/11/15         2019/11/14
 ●     Test Software               Audix                E3                N/A            N/A               N/A
 ●     Turntable             Maturo Germany          TT2.0-1T             N/A            N/A               N/A
 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12           N/A            N/A               N/A

Shenzhen Huatongwei International Inspection Co., Ltd.                 Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                 Page:     10 of 36                 Issued:          2019-07-16


 ●     RF Conducted Method
                                                                                  Last Cal. Date    Next Cal. Date
Used      Test Equipment     Manufacturer         Model No.          Serial No.
                                                                                  (YY-MM-DD)         (YY-MM-DD)
       Signal and spectrum
 ●                               R&S               FSV40              100048       2018/10/28         2019/10/27
       Analyzer
 ●     Spectrum Analyzer        Agilent            N9020A           MY50510187     2018/09/29         2019/09/28
       Radio communication
 ○                               R&S              CMW500             137688-Lv     2018/09/29         2019/09/28
       tester
 ○     Test software          Tonscend          JS1120-1(LTE)           N/A            N/A               N/A

 ○     Test software          Tonscend          JS1120-2(WIFI)          N/A            N/A               N/A

 ○     Test software          Tonscend        JS1120-3(WCDMA)           N/A            N/A               N/A

 ○     Test software          Tonscend         JS1120-4(GSM)            N/A            N/A               N/A




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                     Page:    11 of 36                   Issued:    2019-07-16



5. TEST CONDITIONS AND RESULTS
5.1. Antenna Requirement
Requirement
FCC CFR Title 47 Part 15 Subpart C Section 15.203:
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the response-
ble party shall be used with the device. The use of a permanently attached antenna or of an antenna that
uses a unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken
antenna can be replaced by the user, but the use of a standard antenna jack or electrical connector is
prohibited.
FCC CFR Title 47 Part 15 Subpart C Section 15.247(c) (1)(i):
(i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point operations
may employ transmitting antennas with directional gain greater than 6 dBi provided the maximum conducted
output power of the intentional radiator is reduced by 1 dB for every 3 dB that the directional gain of the
antenna exceeds 6 dBi.

TEST RESULTS

   Passed               Not Applicable


The directional gain of the antenna less than 6 dBi, please refer to the below antenna photo.

                            2.4G&5GWiFi
                             Antenna 1

                                                                         Bluetooth
                      2.4G&5GWiFi                                        Antenna
                       Antenna 0




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                       Page:    12 of 36                Issued:      2019-07-16


5.2. Conducted Emissions (AC Main)
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.207
                                                                          Limit (dBuV)
          Frequency range (MHz)
                                                           Quasi-peak                         Average
                  0.15-0.5                                  66 to 56*                         56 to 46*
                    0.5-5                                      56                                46
                    5-30                                       60                                50
* Decreases with the logarithm of the frequency.


TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.10:2013 requirements.
2. The EUT was placed on a platform of nominal size, 1 m by 1.5 m, raised 80 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 80 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedances stabilization
   network (LISN). The LISN provides a 50 ohm /50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor, was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable

Note:
1) Transd = Cable lose + Pulse Limiter Factor + Artificial Mains Factor
2) Margin = Limit - Level




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


  Level (dBiM]




   150k          300. 400k     600k 800k 1M            an       am    4M SM en    am 10M        2om    som
                                                   Frequency (Hz]
x x sues     omsor0ss012_fin

Frequency               Level       Transd         Limit       Margin        Detector      Line         PE
           MHz           dBuy                 dB    dBuv               as

 0,159000               41.00            9.9            66           24.5   QP             L1         GND
 0.577500               28.50            9.9            56           27.5   oP             L1         GND
 1.536000               32.20            9.9            56           23.3   QP             L1         GND
 4.164000               20. 40           9.9            56           35.6   QP             L1         GND
 5.941500               25.80          10 .0            60           34.2   QP             L1         GND
13.033500               25. 90         10.1             60           34.1   QP             L1         GND

Frequency              Level       Transd          Limit      Margin        Detector       Line        PE
           mHz           dBuy             ds        dBuv               as

 0.168000              30 .10           9.9            55            25.0    AV            L1         GND
 0.546000              20.00            9.9            46            26.0    ay            L1         ND
 1.536000              30 .30           9.9            46            15.7    AV            L1         GND
 2.161500              31.00            9.9            46            15.0    AV            L1         GND
 5.199000              17.90           10.0            50            32.1   aAv            L1         ND
13.060500              21.10           10.1            50            28.9    AV            L1         GND


  Level {dBpV]




   150k          300. 400k    600k 800k 1M        2M       am    4M SM en     am 10M       20M    som
                                              Frequency [He]
x x sues exisorossoni_fin

Frequency               Level      Transd     Limit       Margin       Detector        Line       PE
      MHz                dsuy          dB      dsuy           ds

     357000             28 .60          9.9        59           30.2   oPp             N         GND
     586500             29.40           9.9        56           26.6   P               N         GND
      080500            32.50           9.9        56           23.5   P               N         GND
    539500              25.70           9.9        56           30.3   QP              N         GND
   .784000              26. 60         10.0        60           33.4   QP              N         GND
 13.213500              24.60          10.1        60           35.4   QP              N         GND

Frequency               Level      Transd     Limit      Margin        Detector        Lins       Bot
      MHz                dsuy          ds      dBuy          ds

    375000              22.50           9.9       48            25.9   AV              N         GND
  460500                     .90       $.9        47            25.8    AV             N         GND
  .094000                    .50       $.9        46            30.5    AV             N         GND
   454000                    .70       9. 9       46            23.3   AV              N         GND
  170000                     .50      10.0        50            27.5    AVv            N         GND
13.209000                    10       10.1        50            31.9   AV              N         GND


Report No.:     CHTEW19070052                  Page:     15 of 36               Issued:    2019-07-16


5.3. Conducted Peak Output Power
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.247 (b)(3): 30 dBm


TEST CONFIGURATION




TEST PROCEDURE


1.    The EUT was tested according to ANSI C63.10: 2013 and KDB 558074 D01 for compliance to FCC 47
      CFR 15.247 requirements.
2.    The maximum peak conducted output power may be measured using a broadband peak RF power meter.
3.    The power meter shall have a video bandwidth that is greater than or equal to the DTS bandwidth and
      shall utilize a fast-responding diode detector.
4.    Record the measurement data.


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable

        Type             Channel           Output power (dBm)             Limit (dBm)           Result
                           00                     12.28
      BT-BLE               19                     12.79                     ≤30.00              Pass
                           39                     12.44




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                     Page:   16 of 36                  Issued:    2019-07-16


5.4. Power Spectral Density
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.247 (e):
For digitally modulated systems, the power spectral density conducted from the intentional radiator to the
antenna shall not be greater than 8 dBm in any 3 kHz band during any time interval of continuous
transmission.


TEST CONFIGURATION




TEST PROCEDURE
1.    Connect the antenna port(s) to the spectrum analyzer input,
2.    Configure the spectrum analyzer as shown below:
      Center frequency=DTS channel center frequency
      Span =1.5 times the DTS bandwidth
      RBW = 3 kHz ≤ RBW ≤ 100 kHz, VBW ≥ 3 × RBW
      Sweep time = auto couple
      Detector = peak
      Trace mode = max hold
3.    Place the radio in continuous transmit mode, allow the trace to stabilize, view the transmitter wave form
      on the spectrum analyzer.
4.    Use the peak marker function to determine the maximum amplitude level within the RBW.
5.    If measured value exceeds limit, reduce RBW (no less than 3 kHz) and repeat.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable


                                                Power Spectral
        Type              Channel                                         Limit (dBm/3KHz)           Result
                                              Density(dBm/3KHz)
                             00                      -2.81
      BT-BLE                 19                      -3.36                      ≤8.00                 Pass
                             39                      -2.11


Test plot as follows:




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        17 of 36               Issued:    2019-07-16




         CH00




                                         D ate:11.JUL.2019 10:11:02




         CH19




                                         D ate:11.JUL.2019 10:14:37




         CH39




                                         D ate:11.JUL.2019 10:16:21




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                    Page:   18 of 36                 Issued:    2019-07-16


5.5. 6dB bandwidth
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.247 (a)(2):
For digital modulation systems, the minimum 6 dB bandwidth shall be at least 500 kHz.


TEST CONFIGURATION




TEST PROCEDURE
1.    Connect the antenna port(s) to the spectrum analyzer input.
2.    Configure the spectrum analyzer as shown below (enter all losses between the transmitter output and the
      spectrum analyzer).
      Center Frequency =DTS channel center frequency
      Span=2 x DTS bandwidth
      RBW = 100 kHz, VBW ≥ 3 × RBW
      Sweep time= auto couple
      Detector = Peak
      Trace mode = max hold
3.    Place the radio in continuous transmit mode, allow the trace to stabilize, view the transmitter waveform
      on the spectrum analyzer.
4.    Measure the maximum width of the emission that is constrained by the frequencies associated with the
      two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
      maximum level measured in the fundamental emission, and record the pertinent measurements.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable

        Type             Channel            6dB Bandwidth(MHz)             Limit (kHz)            Result
                           00                      0.75
      BT-BLE               19                      0.75                       ≥500                 Pass
                           39                      0.75


Test plot as follows:




Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        19 of 36               Issued:    2019-07-16




         CH00




                                         D ate:11.JUL.2019 10:10:34




         CH19




                                         D ate:11.JUL.2019 10:14:10




         CH39




                                         D ate:11.JUL.2019 10:15:54




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                    Page:   20 of 36                 Issued:    2019-07-16


5.6. Restricted band
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.247 (d):
In any 100 kHz bandwidth outside the frequency band in which the spread spectrum or digitally modulated
intentional radiator is operating, Radiated Emissions which fall in the restricted bands, as defined in
§15.205(a), must also comply with the Radiated Emissions limits specified in §15.209(a) (see §15.205(c)).
TEST CONFIGURATION




TEST PROCEDURE

1.    The EUT was setup and tested according to ANSI C63.10:2013 for compliance to FCC 47CFR 15.247
      requirements.
2.    The EUT is placed on a turn table which is 1.5 meter above ground. The turn table is rotated 360 degrees
      to determine the position of the maximum emission level.
3.    The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
4.    The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
      repeated for both horizontal and vertical polarization of the antenna. In order to find themaximum
      emission, all of the interface cables were manipulated according to ANSI C63.10:2013 on radiated
      measurement.
5.    The receiver set as follow:
      RBW=1MHz, VBW=3MHz Peak detector for Peak value.
      RBW=1MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed             Not Applicable


Note:
1) Final level= Read level + Antenna Factor+ Cable Loss- Preamp Factor
2) The peak level is lower than average limit(54 dBuV/m), this data is the too weak instrument of signal is
    unable to test.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                   Page:     21 of 36               Issued:      2019-07-16


Test channel                                              CH00
      Freq.         Reading     Factor      Level          Limit     Margin
                                                                                 Polarity        Detector
     [MHz]         [dBμV/m]      [dB]     [dBμV/m]       [dBμV/m]     [dB]
   2310.0045         52.59      -2.34       50.25         74.00      23.75       Vertical         Peak
   2390.0004         51.39      -2.41       48.98         74.00      25.02       Vertical         Peak
   2310.0045         45.35      -2.34       43.01         54.00      10.99       Vertical        Average
   2390.0004         44.68      -2.41       42.27         54.00      11.73       Vertical        Average
   2310.0045         52.85      -2.34       50.51         74.00      23.49      Horizontal        Peak
   2390.0138         52.39      -2.41       49.98         74.00      24.02      Horizontal        Peak
   2310.0045         46.27      -2.34       43.93         54.00      10.07      Horizontal       Average
   2390.0138         45.57      -2.41       43.16         54.00      10.84      Horizontal       Average

Test channel                                             CH39
     Freq.         Reading     Factor      Level         Limit      Margin
                                                                                 Polarity         Detector
     [MHz]        [dBμV/m]      [dB]     [dBμV/m]      [dBμV/m]      [dB]
  2483.5000        61.83       -2.15      59.68          74.00      14.32       Horizontal         Peak
  2500.0000        58.46       -2.10      56.36          74.00      17.64       Horizontal         Peak
  2483.5000        54.72       -2.15      52.57          54.00      1.43        Horizontal        Average
  2500.0000        45.26       -2.10      43.16          54.00      10.84       Horizontal        Average
  2483.5000        58.35       -2.15      56.20          74.00      17.80        Vertical          Peak
  2500.0000        57.15       -2.10      55.05          74.00      18.95        Vertical          Peak
  2483.5000        55.12       -2.15      52.97          54.00      1.03         Vertical         Average
  2500.0000        46.27       -2.10      44.17          54.00      9.83         Vertical         Average




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                    Page:    22 of 36                 Issued:    2019-07-16


5.7. Band edge and Spurious Emissions (conducted)
LIMIT

FCC CFR Title 47 Part 15 Subpart C Section15.247 (d):In any 100 kHz bandwidth outside the frequency
band in which the spread spectrum intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement.

TEST CONFIGURATION




TEST PROCEDURE
1.    Connect the antenna port(s) to the spectrum analyzer input.
2.    Establish a reference level by using the following procedure
      Center frequency=DTS channel center frequency
      The span = 1.5 times the DTS bandwidth.
      RBW = 100 kHz, VBW ≥ 3 x RBW
      Detector = peak, Sweep time = auto couple, Trace mode = max hold
      Allow trace to fully stabilize
      Use the peak marker function to determine the maximum PSD level

      Note that the channel found to contain the maximum PSD level can be used to establish the reference
      level.
3.    Emission level measurement
      Set the center frequency and span to encompass frequency range to be measured
      RBW = 100 kHz, VBW ≥ 3 x RBW
      Detector = peak, Sweep time = auto couple, Trace mode = max hold
      Allow trace to fully stabilize
      Use the peak marker function to determine the maximum amplitude level.
4.    Place the radio in continuous transmit mode, allow the trace to stabilize, view the transmitter waveform
      on the spectrum analyzer.
5.    Ensure that the amplitude of all unwanted emission outside of the authorized frequency band excluding
      restricted frequency bands) are attenuated by at least the minimum requirements specified (at least 20
      dB relative to the maximum in-band peak PSD level in 100 kHz). Report the three highest emission
      relative to the limit.


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        23 of 36               Issued:    2019-07-16


Test Item:                 Band edge




         CH00




                                         D ate:11.JUL.2019 10:11:13




         CH39




                                         D ate:11.JUL.2019 10:16:32




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        24 of 36               Issued:    2019-07-16


Test Item:                 SE




         CH00
     Reference level




                                         D ate:11.JUL.2019 10:11:22




       CH00
   30MHz~1000MHz




                                         D ate:11.JUL.2019 10:11:40




        CH00
     1GHz~26GHz




                                         D ate:11.JUL.2019 10:11:57




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        25 of 36               Issued:    2019-07-16




         CH19
     Reference level




                                         D ate:11.JUL.2019 10:14:44




       CH19
   30MHz~1000MHz




                                         D ate:11.JUL.2019 10:15:01




        CH19
     1GHz~26GHz




                                         D ate:11.JUL.2019 10:15:19




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:    CHTEW19070052                             Page:        26 of 36               Issued:    2019-07-16




         CH39
     Reference level




                                         D ate:11.JUL.2019 10:16:40




       CH39
   30MHz~1000MHz




                                         D ate:11.JUL.2019 10:16:57




        CH39
     1GHz~26GHz




                                         D ate:11.JUL.2019 10:17:14




Shenzhen Huatongwei International Inspection Co., Ltd.                           Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                  Page:     27 of 36               Issued:      2019-07-16


5.8. Spurious Emissions (radiated)
LIMIT
FCC CFR Title 47 Part 15 Subpart C Section 15.209
             Frequency                        Limit (dBuV/m @3m)                            Value
              30MHz~88MHz                                 40.00                           Quasi-peak
              88MHz~216MHz                                43.50                           Quasi-peak
          216MHz~960MHz                                   46.00                           Quasi-peak
              960MHz~1GHz                                 54.00                           Quasi-peak
                                                          54.00                            Average
               Above 1GHz
                                                          74.00                             Peak

TEST CONFIGURATION
   9 kHz ~ 30 MHz




   30 MHz ~ 1 GHz




   Above 1 GHz




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                      Page:    28 of 36                  Issued:     2019-07-16

TEST PROCEDURE
1.    The EUT was setup and tested according to ANSI C63.10:2013 for compliance to FCC 47CFR 15.247
      requirements.
2.    The EUT is placed on a turn table which is 0.8 meter above ground for below 1 GHz, and 1.5 m for above
      1 GHz. The turn table is rotated 360 degrees to determine the position of the maximum emission level.
3.    The EUT was set 3 meters from the receiving antenna, which was mounted on the top of a variable
      height antenna tower.
4.    For each suspected emission, the EUT was arranged to its worst case and then tune the Antenna tower
      (from 1 m to 4 m) and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp
      and a high pass filter are used for the test in order to get better signal level to comply with the guidelines.
5.    Set to the maximum power setting and enable the EUT transmit continuously.
6.    Use the following spectrum analyzer settings
      (1) Span shall wide enough to fully capture the emission being measured;
      (2) Below 1 GHz:
           RBW=120 kHz, VBW=300 kHz, Sweep=auto, Detector function=peak, Trace=max hold;
           If the emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
           the peak emission level will be reported. Otherwise, the emission measurement will be repeated
           using the quasi-peak detector and reported.
                             th
      (3) From 1 GHz to 10 harmonic:
           RBW=1MHz, VBW=3MHz Peak detector for Peak value.
           RBW=1MHz, VBW=3MHz RMS detector for Average value.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

     Passed              Not Applicable

Note:
1) Above 1GHz Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2) The emission levels of other frequencies are very lower than the limit and not show in test report.

     9 kHz ~ 30 MHz
      The EUT was pre-scanned the frequency band (9 kHz ~ 30 MHz), found the radiated level lower than the
      limit, so don’t show on the report.

     30 MHz ~ 1000 MHz
      Have pre-scan all modulation mode, found the BT-BLE mode CH39 which it was worst case, so only the
      worst case’s data on the test report.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No.:     CHTEW19070052                  Page:      29 of 36                Issued:    2019-07-16


 30 MHz ~ 1 GHz
Polarization:                                            Vertical




Polarization:                                            Horizontal




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


Report No.:      CHTEW19070052                         Page:    30 of 36                    Issued:     2019-07-16


 1 GHz ~ 25 GHz
Test channel                                                    CH00
     Freq.            Reading      Factor        Level           Limit       Margin
                                                                                             Polarity          Detector
     [MHz]           [dBμV/m]       [dB]       [dBμV/m]        [dBμV/m]       [dB]
   1583.0938           34.50        -6.17        28.33          74.00        45.67          Vertical             Peak
   3157.5938           40.50         0.62        41.12          74.00        32.88          Vertical             Peak
   5074.3125           31.40         8.56        39.96          74.00        34.04          Vertical             Peak
   5796.9375           32.16         9.53        41.69          74.00        32.31          Vertical             Peak
   1712.3438           34.04        -6.06        27.98          74.00        46.02         Horizontal            Peak
   3050.3750           33.52         0.10        33.62          74.00        40.38         Horizontal            Peak
   3880.2188           32.36         2.54        34.90          74.00        39.10         Horizontal            Peak
   5190.3438           30.98         8.96        39.94          74.00        34.06         Horizontal            Peak


Test channel                                                    CH19
                     Reading
     Freq.                         Factor        Level           Limit       Margin
                    [dBμV/m]                                                                 Polarity          Detector
     [MHz]                          [dB]       [dBμV/m]        [dBμV/m]       [dB]
  1659.4688           33.78         -6.17        27.61          74.00        46.39         Horizontal            Peak
  3194.3125           34.26          0.81        35.07          74.00        38.93         Horizontal            Peak
  5883.5938           32.11          9.91        42.02          74.00        31.98         Horizontal            Peak
  6667.9063           32.49         13.37        45.86          74.00        28.14         Horizontal            Peak
  1199.7500           35.55         -5.83        29.72          74.00        44.28          Vertical             Peak
  3448.4063           36.21          0.43        36.64          74.00        37.36          Vertical             Peak
  4784.9688           36.02          6.95        42.97          74.00        31.03          Vertical             Peak
  7321.5000           34.45         16.12        50.57          74.00        23.43          Vertical             Peak


Test channel                                                   CH39
                   Reading
     Freq.                       Factor        Level         Limit         Margin
                  [dBμV/m]                                                                  Polarity           Detector
    [MHz]                         [dB]       [dBμV/m]      [dBμV/m]         [dB]
 1637.4375          34.24         -6.21        28.03           74.00        45.97          Vertical              Peak
 3104.7188          39.03          0.34        39.37           74.00        34.63          Vertical              Peak
 3703.9688          33.64          1.61        35.25           74.00        38.75          Vertical              Peak
 4780.5625          35.92          6.92        42.84           74.00        31.16          Vertical              Peak
 1403.9063          33.24         -5.58        27.66           74.00        46.34         Horizontal             Peak
 3189.9063          35.10          0.79        35.89           74.00        38.11         Horizontal             Peak
 4157.8125          32.06          3.58        35.64           74.00        38.36         Horizontal             Peak
 5128.6563          31.81          8.85        40.66           74.00        33.34         Horizontal             Peak
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The peak level is lower than average limit(54dBuV/m), this data is the too weak instrument of signal is unable to test.
3. The emission levels of other frequencies are very lower than the limit and not show in test report.