RF Exposure

FCC ID: 2ATV2-WMBR-1

RF Exposure Info

Download: PDF
FCCID_4383742

FCC ID: 2ATV2-WMBR-1

                                              RF Exposure Evaluation
LIMIT
The criteria listed in the following table shall be used to evaluate the environment impact of human exposure to radio
frequency (RF) radiation as specified in 1.1307(b)
Limits for Maximum Permissible Exposure (MPE)
                             Electric field
 Frequency range                                     Magnetic field strength        Power density         Averaging time
                               strength                                                               2
        (MHz)                                                 (A/m)                   (mW/cm )              (minutes)
                                (V/m)
                                         (A) Limits for Occupational/Controlled Exposures
      0.3–3.0                    614                          1.63                      *(100)                  6
                                                                                                  2
        3.0–30                  1842/f                        4.89/f                   *(900/f )                6
      30–300                     61.4                         0.163                         1.0                 6
     300–1500                      -                            -                       f/300                   6
   1500–100,000                    -                            -                           5                   6
                                  (B) Limits for General Population/Uncontrolled Exposure
     0.3–1.34                    614                          1.63                      *(100)                 30
                                                                                                  2
      1.34–30                    824/f                        2.19/f                   *(180/f )               30
      30–300                     27.5                         0.073                         0.2                30
     300–1500                      -                            -                       f/1500                 30
   1500–100,000                    -                            -                           1.0                30
Note: f = frequency in MHz


EVALUATION METHOD
Transmission formula: Pd = (Pout*G)/(4*pi*r2)
Where
Pd = power density in mW/cm2, Pout = output power to antenna in mW, G = gain of antenna in linear scale;
Pi = 3.1416, R = distance between observation point and center of the radiator in cm


TEST RESULT


    Passed                                Not Applicable


FCC ID: 2ATV2-WMBR-1




    RF                                   Maximum
                                                           Power Density             Limit
specification        Type             conducted output                                                Result
                                                              (mW/cm2)            (mW/cm2)
                                        power(dBm)
 2.4G WiFi      802.11n(HT20)              19.96               0.01971              1.0000            Pass
  5G WiFi       802.11ac(HT20)             18.61               0.01445              1.0000            Pass
 5.8G SRD       802.11ac(HT20)             18.51               0.01412              1.0000            Pass
 Bluetooth            BLE                  12.79               0.00378              1.0000            Pass


    RF            Field strength of          Maximum          Power Density
                                                                                 Limit (mW/cm2)       Result
specification   fundamental(dBμV/m)         ERIP(dBm)           (mW/cm2)

  Z-wave                93.01                  -2.22            0.00012              0.6056            Pass

Note:
 1) The maximum antenna gain for WiFi and Bluetooth are 2.00dBi. The maximum antenna gain for Z-wave is 3.00dBi.
 2) EIRP[dBm] = E[dBμV/m] + 20 log (d[m]) − 104.77,d=3.
 3) The exposure safety distance is less than 20cm.



Document Created: 2019-07-17 13:58:57
Document Modified: 2019-07-17 13:58:57

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC