RF Exposure

FCC ID: 2ATPD20190601

RF Exposure Info

Download: PDF
FCCID_4343688

                                Intertek Testing Services Shenzhen Ltd.
                                Guangzhou Branch
                                                              Job No.: 190513123GZU
                                                              Page:              1 of 1
                                                              FCC ID: 2ATPD20190601



RF Exposure Compliance Requirement

   Calculation formula:
   E (V/m) = (30*P*G) 0.5/d
   E = Electric Field (V/m)
   P = Peak RF output Power (W)
   G = EUT Antenna numeric gain (numeric)
   d = Separation distance between EUT and antenna (m)
                       X (dBUV/m) /20   -6
   Remark: E(V/m)=10                ×10
           2
   P=(E*d) /30G

   in the formula above, d=3m, field strength= 80dBuV/m(max describe by client), G=0
   so P=0.03mW


 In KDB 447498 D01 v06: 4.3.1 Standalone SAR test exclusion considerations:


 The SAR Test Exclusion Threshold is calculated from:
 [(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√f(GHz)]
 ≤ 3.0 for 1-g SAR.
 The worst case test separation distance is 5mm.
 The product belongs to standalone portable device base the FCC rule part 2.1091&2.1093. The
 transmission frequencies of the device are between 100 MHz and 6 GHz.


 The ERP and SAR Test Exclusion Threshold (mW) are listed below:


                                             Output power             SAR Test Exclusion
  Transmit frequency (MHz)
                                                (mW)                    Threshold (mW)
           433.92                                0.03                        22.77




 According to SAR Exclusion Threshold in KDB 447498 (D01) General RF Exposure
 Guidance v06, the SAR report is not required.