DXX REPORT

FCC ID: 2ATOV-001

Test Report

Download: PDF
FCCID_4352223

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201905000216F01



                                       FCC REPORT
    Applicant:                        Microtech Medical (Hangzhou) Co., Ltd.

    Address of Applicant:             No.9 Haishu Rd., Yuhang District Hangzhou 311121 Zhejiang
                                      China
    Manufacturer/Factory:             Microtech Medical (Hangzhou) Co., Ltd.

    Address of                        No.9 Haishu Rd., Yuhang District Hangzhou 311121 Zhejiang
    Manufacturer/Factory:             China
    Equipment Under Test (EUT)

      Product Name:                   Personal Diabetes Assistant

      Model No.:                      G7-P02, MTM-2
      Trade Mark:                     Aidex, equil

    FCC ID:                           2ATOV-001

    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C Section 15.249

    Date of sample receipt:           May 27, 2019

    Date of Test:                     May 28-June 13, 2019

    Date of report issued:            June 14, 2019

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201905000216F01

2      Version

           Version No.                                  Date                            Description
                 00                                June 14, 2019                          Original




Prepared By:                                                       Date:                 June 14, 2019

                                     Project Engineer


Check By:                                                          Date:                 June 14, 2019

                                          Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 2 of 25


                                                                                                            Report No.: GTS201905000216F01

3         Contents
                                                                                                                                                           Page
1     COVER PAGE ............................................................................................................................................ 1

2      VERSION .................................................................................................................................................. 2

3      CONTENTS .............................................................................................................................................. 3

4      TEST SUMMARY ..................................................................................................................................... 4
    4.1        MEASUREMENT UNCERTAINTY ............................................................................................................ 4
5      GENERAL INFORMATION ...................................................................................................................... 5
    5.1        GENERAL DESCRIPTION OF EUT ......................................................................................................... 5
    5.2        TEST MODE ........................................................................................................................................ 7
    5.3        DESCRIPTION OF SUPPORT UNITS ....................................................................................................... 7
    5.4        TEST FACILITY.................................................................................................................................... 7
    5.5        TEST LOCATION ................................................................................................................................. 7
6      TEST INSTRUMENTS LIST ..................................................................................................................... 8

7      TEST RESULTS AND MEASUREMENT DATA.................................................................................... 10
    7.1     ANTENNA REQUIREMENT ................................................................................................................... 10
    7.2     CONDUCTED EMISSIONS ................................................................................................................... 11
    7.3     RADIATED EMISSION METHOD ........................................................................................................... 14
       7.3.1 Field Strength of The Fundamental Signal ................................................................................ 16
       7.3.2 Spurious emissions .................................................................................................................... 17
       7.3.3 Bandedge emissions.................................................................................................................. 22
    7.4     20DB OCCUPY BANDWIDTH .............................................................................................................. 23
8      TEST SETUP PHOTO ............................................................................................................................ 25

9      EUT CONSTRUCTIONAL DETAILS ..................................................................................................... 25




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                     Page 3 of 25


                                                                               Report No.: GTS201905000216F01

4      Test Summary
                 Test Item                             Section in CFR 47                      Result
           Antenna requirement                                15.203                           Pass
    AC Power Line Conducted Emission                          15.207                           Pass
Field strength of the fundamental signal                    15.249 (a)                         Pass
           Spurious emissions                         15.249 (a) (d)/15.209                    Pass
                Band edge                               15.249 (d)/15.205                      Pass
        20dB Occupied Bandwidth                             15.215 (c)                         Pass
Remarks:
1. Test according to ANSI C63.10: 2013.
2. Pass: The EUT complies with the essential requirements in the standard.


4.1 Measurement Uncertainty
            Test Item                      Frequency Range                Measurement Uncertainty        Notes
        Radiated Emission                     9kHz ~ 30MHz                         4.34dB                (1)
        Radiated Emission                  30MHz ~ 1000MHz                         4.24dB                (1)
        Radiated Emission                   1GHz ~ 26.5GHz                         4.68dB                (1)
    AC Power Line Conducted
                                            0.15MHz ~ 30MHz                        3.45dB                (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 4 of 25


                                                                               Report No.: GTS201905000216F01

5      General Information
5.1 General Description of EUT
      Product Name:                      Personal Diabetes Assistant

      Model No.:                         G7-P02, MTM-2

      Test Model No.:                    G7-P02

      Remark: All above models are identical in the same PCB layout, interior structure and electrical circuits.
      The differences are model name and software for commercial purpose.
      Serial No.:                   PA00025

      Hardware Version:                  1100_1_20
      Software Version:                  1.0
      Test sample(s) ID:                 GTS201905000216-1
      Sample(s) Status                   Engineered sample
      Operation Frequency:               2402MHz~2480MHz
      Channel numbers:                   40
      Channel separation:                2MHz
      Modulation type:                   GFSK
      Antenna Type:                      PIFA Antenna
      Antenna gain:                      0dBi(declare by applicant)
                                         Adapter:
                                         Model: SINGOF-5U-050100
                                         Input: AC100-240V, 50/60Hz, 0.16-0.07A
      Power supply:
                                         Output: DC 5V, 1A
                                         Or
                                         Battery: DC 3.7V, 1000mAh




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                               Page 5 of 25


                                                                                 Report No.: GTS201905000216F01


Operation Frequency each of channel
 Channel       Frequency        Channel       Frequency       Channel          Frequency   Channel         Frequency
     1          2402MHz            11         2422MHz            21            2442MHz       31            2462MHz
     2          2404MHz            12         2424MHz            22            2444MHz       32            2464MHz
   .
   ..…



                   .
                   ..…



                                 .
                                 ..…



                                                 .
                                                 ..…



                                                                .
                                                                ..…



                                                                                 .
                                                                                 ..…



                                                                                            .
                                                                                            ..…



                                                                                                             .
                                                                                                             ..…
     9          2418MHz            19         2438MHz            29            2458MHz       39            2478MHz
    10          2420MHz            20         2440MHz            30            2460MHz       40            2480MHz
Note:
In section 15.31(m), regards to the operating frequency range over 10 MHz, the Lowest frequency, the
middle frequency, and the highest frequency of channel were selected to perform the test, and the selected
channel see below:
         Channel                        Frequency
   The lowest channel                   2402MHz
   The middle channel                   2440MHz
  The Highest channel                   2480MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 6 of 25


                                                                                Report No.: GTS201905000216F01


5.2 Test mode
       Transmitting mode                    Keep the EUT in continuously transmitting mode.
       Remark: During the test, the dutycycle >98%, the test voltage was tuned from 85% to 115% of the
       nominal rated supply voltage, and found that the worst case was under the nominal rated supply
       condition. So the report just shows that condition’s data.


Per-test mode.
We have verified the construction and function in typical operation, The EUT was placed on three different
polar directions; i.e. X axis, Y axis, Z axis. which was shown in this test report and defined as follows:
             Axis                           X                             Y                          Z
  Field Strength(dBuV/m)                 93.55                          94.19                     92.43
5.3 Description of Support Units
       N/A
5.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:
       ● FCC —Registration No.: 381383
       Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in files. Registration 381383.
       ● Industry Canada (IC) —Registration No.: 9079A-2
       The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
       Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
       No.: 9079A-2.
       ● NVLAP (LAB CODE:600179-0)
       Global United Technology Services Co., Ltd., is accredited by the National Voluntary Laboratory
       Accreditation Program (NVLAP). LAB CODE:600179-0
5.5 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      Address: No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road,
      Baoan District, Shenzhen, Guangdong, China 518102
      Tel: 0755-27798480
      Fax: 0755-27798960




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 7 of 25


                                                                               Report No.: GTS201905000216F01

6       Test Instruments list
Radiated Emission:

                                                                               Inventory      Cal.Date      Cal.Due date
Item       Test Equipment          Manufacturer              Model No.
                                                                                 No.        (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron      9.2(L)*6.2(W)* 6.4(H)   GTS250      July. 03 2015    July. 02 2020
             Chamber
 2         Control Room          ZhongYu Electron      6.2(L)*2.5(W)* 2.4(H)   GTS251          N/A              N/A
 3       EMI Test Receiver       Rohde & Schwarz              ESU26            GTS203      June. 27 2018    June. 26 2019
                                 SCHWARZBECK
 4       BiConiLog Antenna                                  VULB9163           GTS214      June. 27 2018    June. 26 2019
                                MESS-ELEKTRONIK
           Double -ridged        SCHWARZBECK
 5                                                        BBHA 9120 D          GTS208      June. 27 2018    June. 26 2019
           waveguide horn       MESS-ELEKTRONIK

 6         Horn Antenna          ETS-LINDGREN                  3160            GTS217      June. 27 2018    June. 26 2019
 7       EMI Test Software            AUDIX                     E3               N/A           N/A              N/A
 8         Coaxial Cable               GTS                     N/A             GTS213      June. 27 2018    June. 26 2019
 9         Coaxial Cable               GTS                     N/A             GTS211      June. 27 2018    June. 26 2019
10         Coaxial cable               GTS                     N/A             GTS210      June. 27 2018    June. 26 2019
11         Coaxial Cable               GTS                     N/A             GTS212      June. 27 2018    June. 26 2019
12     Amplifier(100kHz-3GHz)           HP                    8347A            GTS204      June. 27 2018    June. 26 2019
13     Amplifier(2GHz-20GHz)            HP                   84722A            GTS206      June. 27 2018    June. 26 2019
                                                          AFS33-18002
14      Amplifier (18-26GHz)     Rohde & Schwarz                               GTS218      June. 27 2018    June. 26 2019
                                                          650-30-8P-44
15           Band filter             Amindeon                 82346            GTS219      June. 27 2018    June. 26 2019
16          Power Meter               Anritsu               ML2495A            GTS540      June. 27 2018    June. 26 2019
17         Power Sensor               Anritsu               MA2411B            GTS541      June. 27 2018    June. 26 2019
         Wideband Radio
18                               Rohde & Schwarz             CMW500            GTS575      June. 27 2018    June. 26 2019
       Communication Tester
19            Splitter                Agilent                11636B            GTS237      June. 27 2018    June. 26 2019
20         Loop Antenna               ZHINAN                ZN30900A           GTS534      June. 27 2018    June. 26 2019
             Breitband
21                               SCHWARZBECK               BBHA 9170           GTS579      Oct. 20 2018     Oct. 19 2019
            hornantenne
22            Amplifier                TDK                  PA-02-02           GTS574      Oct. 20 2018     Oct. 19 2019
23            Amplifier                TDK                  PA-02-03           GTS576      Oct. 20 2018     Oct. 19 2019
        PSA Series Spectrum
24                               Rohde & Schwarz               FSP             GTS578      June. 27 2018    June. 26 2019
             Analyzer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 8 of 25


                                                                                Report No.: GTS201905000216F01


Conducted Emission
                                                                                Inventory      Cal.Date       Cal.Due date
Item       Test Equipment           Manufacturer            Model No.
                                                                                   No.        (mm-dd-yy)      (mm-dd-yy)
 1        Shielding Room          ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)       GTS252      May.15 2019     May.14 2022
 2       EMI Test Receiver             R&S                   ESCI 7              GTS552     June. 27 2018    June. 26 2019
 3         Coaxial Switch         ANRITSU CORP               MP59B               GTS225     June. 27 2018    June. 26 2019
                                  SCHWARZBECK
 4     Artificial Mains Network                             NSLK8127             GTS226     June. 27 2018    June. 26 2019
                                     MESS
 5         Coaxial Cable               GTS                     N/A               GTS227     June. 27 2018    June. 26 2019

 6       EMI Test Software            AUDIX                     E3                 N/A           N/A             N/A
 7         Thermo meter                 KTJ                   TA328              GTS233     June. 27 2018    June. 26 2019
                                    Elektronik-
 8        Absorbing clamp                                    MDS21               GTS229     June. 27 2018    June. 26 2019
                                   Feinmechanik



RF Conducted Test:
                                                                                               Cal.Date       Cal.Due date
Item         Test Equipment          Manufacturer          Model No.           Serial No.
                                                                                              (mm-dd-yy)      (mm-dd-yy)
 1        MXA Signal Analyzer           Agilent            N9020A              GTS566       June. 27 2018    June. 26 2019
 2         EMI Test Receiver             R&S                ESCI 7             GTS552       June. 27 2018    June. 26 2019
 3         Spectrum Analyzer            Agilent            E4440A              GTS533       June. 27 2018    June. 26 2019
           MXG vector Signal
 4                                      Agilent            N5182A              GTS567       June. 27 2018    June. 26 2019
               Generator
           ESG Analog Signal
 5                                      Agilent            E4428C              GTS568       June. 27 2018    June. 26 2019
               Generator
 6       USB RF Power Sensor            DARE              RPR3006W             GTS569       June. 27 2018    June. 26 2019
 7           RF Switch Box             Shongyi          RFSW3003328            GTS571       June. 27 2018    June. 26 2019
        Programmable Constant
 8           Temp & Humi               WEWON         WHTH-150L-40-880          GTS572       June. 27 2018    June. 26 2019
             Test Chamber



General used equipment:
                                                                                              Cal.Date        Cal.Due date
Item       Test Equipment           Manufacturer          Model No.        Inventory No.
                                                                                             (mm-dd-yy)       (mm-dd-yy)
       Humidity/ Temperature
 1                                      KTJ                TA328               GTS243       June. 27 2018    June. 26 2019
             Indicator
 2            Barometer             ChangChun              DYM3                GTS255       June. 27 2018    June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 9 of 25


                                                                                 Report No.: GTS201905000216F01

7      Test results and Measurement Data
7.1 Antenna requirement
      Standard requirement:             FCC Part15 C Section 15.203
        15.203 requirement:
        An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
        responsible party shall be used with the device. The use of a permanently attached antenna or of an
        antenna that uses a unique coupling to the intentional radiator, the manufacturer may design the unit
        so that a broken antenna can be replaced by the user, but the use of a standard antenna jack or
        electrical connector is prohibited.
        15.247(c) (1)(i) requirement:
        (i) Systems operating in the 2400-2483.5 MHz band that is used exclusively for fixed. Point-to-point
        operations may employ transmitting antennas with directional gain greater than 6dBi provided the
        maximum conducted output power of the intentional radiator is reduced by 1 dB for every 3 dB that the
        directional gain of the antenna exceeds 6dBi.
      EUT Antenna:
       The antenna is PIFA antenna, the best case gain of the antenna is 0dBi, reference to the appendix II for details




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 10 of 25


                                                                                 Report No.: GTS201905000216F01
7.2 Conducted Emissions
      Test Requirement:                FCC Part15 C Section 15.207
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            150KHz to 30MHz
      Class / Severity:                Class B                 Class B
      Receiver setup:                  RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                            Limit (dBuV)
                                          Frequency range (MHz)
                                                                               Quasi-peak              Average
                                                  0.15-0.5                      66 to 56*              56 to 46*
                                                    0.5-5                          56                     46
                                                     5-30                          60                     50
                                       * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                  1. The EUT and simulators are connected to the main power through a
                                          line impedance stabilization network (L.I.S.N.). This provides a
                                          50ohm/50uH coupling impedance for the measuring equipment.
                                       2. The peripheral devices are also connected to the main power through a
                                          LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                          termination. (Please refer to the block diagram of the test setup and
                                          photographs).
                                       3. Both sides of A.C. line are checked for maximum conducted
                                          interference. In order to find the maximum emission, the relative
                                          positions of equipment and all of the interface cables must be changed
                                          according to ANSI C63.10: 2013 on conducted measurement.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test environment:                Temp.:        25 C         Humid.:        52%         Press.:          1012mbar
      Test voltage:                    AC 120V, 60Hz
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 11 of 25


 GTS
                                                                                        Report No.: GTS201905000216FO1
Measurement data

 Mode:                        Transmitting mode                                 Test by:               Bill
 Temp./Hum.(%H):              26°C/56%RH                                        Probe:                 Line




 ag Level BW

 T0

 m                                                                               ]—
  m\



 40
                          i                     (



 ®>                  j    |               w
                                                |
  10                                       \

   0


 1 0.150.2                     0.5                  1          2                 5             10             20    30
                                                         Frequency (MHz)
        Freq     Reading       LISN/ISN        Cable                Limit     Over
                 level           factor         loss       Level     level     limit       Remark
         MHz      dBu¥               dB/m           cB     dBuy      dBu¥        dB
        0.18     40.18               0.   40   0.   09   40.   67   64. 64    —23.97          QP
        0.18      31.93              0.   40   0.   09   32.   42   54.64     —22. 22         Average
        0.24      36.23              0.   40   0.   L1   36.   74   62.26     —25.52          QP
        0. 24    27. 70              0.   40   0.   11   28.   21   52.26     —24.05          Average
        0.30     31.03               0.   40   0.   10   31.   53   60.37    —28. 84          oP
        0.30     27.83               0.   40   0.   10   28.   33   50. 37    —22.04          Average
        0.36     30.40               0.   37   0.   10   30.   87   §8.87     —28.00          qP
        0.36      23.37              0.   37   0.   10   23.   84   48.87     —25.03          Average
        0.41     29.33               0.   35   0.   11   29.   79   §7. 64    —27.85          QP
        O.41      23.76              0.   35   0.   11   24.   22   47. 64   —23. 42          Average
        0.95      31.10              0.   21   0.   15   31.   46   56. 00   —24,. 54         QP
        0.95      19.96              0.   21   0.   15   20,   32   46. 00   —25, 68          Average




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                         Page 12 of 25


 GTS
                                                                                                   Report No.: GTS201905000216FO1



 Mode:                          Transmitting mode                                            Test by:               Bill
 Temp./Hum.(%H):                26°C/56%RH                                                   Probe:                 Neutral


        Level (dBuV)


  70


  50\



  40

  30                               I             l’   |

  20|                              {             2
  10                                                  f

   0


 1 0.150.2                       0.5                       1               2                  5            10              20    30
                                                                Frequency (MHz)
           Freq    Reading        LISN/ISN            Cable                    Limt        Over
                   level            factor             loss       Level         level       limit       Renark
            IHz         dBu¥           dB/m                dB     dBu¥          dBu¥          dB

           0.18         41.82          0.   40        0.   09   42.   31       64. 68      —22.37          QP
           0.18        30.08           0,   40        0,   09   30.   57       §4.68       —24.11          Average
           0.23         37.06          0,   40        0.   11   37.   57       62. 30     —24.73
           0.23         26.51          0.   40        0.   11   27.   02       52. 30      —25. 28         Average
           0. 30       33. 04          0. 40          0. 10     33. 54         60.37      —26. 93          qP
           0. 30       25. 73          0. 40          0. 10     26. 23         50.37      —24.14           Average
           0. 35       30. 63          0. 37          0. 10     31.10          §8.87      —27.77           QP
           0.35         21.03          0.   37        0.   10   21. 50         48.   87    —27. 37         Average
           0.§3        30.72           0.   31        0.   11   31.14          56.   00   —24.86           QP
           0.53        19.43           0.   31        0.   11   19. 85         46.   00    —26.15          Average
           0.77         33.53          0.   24        0.   14   33. 91         56.   00   —22. 09
           0.77        18. 34          0.   24        0.   14   18. 72         46.   00   —27. 28          Average



Notes:
1. An initial pre—scan was performed on the line and neutral lines with peak detector.
2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak
     emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                      Page 13 of 25


                                                                                 Report No.: GTS201905000216F01


7.3 Radiated Emission Method
      Test Requirement:                FCC Part15 C Section 15.209
      Test Method:                     ANSI C63.10:2013
      Test Frequency Range:            9kHz to 25GHz
      Test site:                       Measurement Distance: 3m
      Receiver setup:                    Frequency         Detector             RBW     VBW          Remark
                                           9kHz-          Quasi-peak           200Hz   300Hz     Quasi-peak Value
                                          150kHz
                                          150kHz-         Quasi-peak           9kHz    10kHz     Quasi-peak Value
                                           30MHz
                                          30MHz-          Quasi-peak       120KHz      300KHz    Quasi-peak Value
                                            1GHz
                                                              Peak        1MHz       3MHz         Peak Value
                                        Above 1GHz
                                                              Peak        1MHz        10Hz       Average Value
      Limit:                                    Frequency             Limit (dBuV/m @3m)            Remark
      (Field strength of the                                                   94.00             Average Value
      fundamental signal)                 2400MHz-2483.5MHz
                                                                              114.00              Peak Value
      Limit:                                    Frequency                  Limit (uV/m)             Remark
      (Spurious Emissions)                0.009MHz-0.490MHz           2400/F(kHz) @300m        Quasi-peak Value
                                          0.490MHz-1.705MHz           24000/F(kHz) @30m        Quasi-peak Value
                                           1.705MHz-30.0MHz                 30 @30m            Quasi-peak Value
                                             30MHz-88MHz                    100 @3m            Quasi-peak Value
                                             88MHz-216MHz                   150 @3m            Quasi-peak Value
                                            216MHz-960MHz                   200 @3m            Quasi-peak Value
                                              960MHz-1GHz                   500 @3m            Quasi-peak Value
                                                                            500 @3m              Average Value
                                               Above 1GHz
                                                                            5000 @3m              Peak Value
      Limit:                           Emissions radiated outside of the specified frequency bands, except for
      (band edge)                      harmonics, shall be attenuated by at least 50 dB below the level of the
                                       fundamental or to the general radiated emission limits in Section 15.209,
                                       whichever is the lesser attenuation.
      Test setup:
                                       For radiated emissions from 9kHz to 30MHz




                                       For radiated emissions from 30MHz to1GHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                Page 14 of 25


                                                                               Report No.: GTS201905000216F01




                                       For radiated emissions above 1GHz




      Test Procedure:                  1. The EUT was placed on the top of a rotating table (0.8m for below
                                          1GHz and 1.5 meters for above 1GHz) above the ground at a 3 meter
                                          camber. The table was rotated 360 degrees to determine the position of
                                          the highest radiation.
                                       2. The EUT was set 3 meters away from the interference-receiving
                                          antenna, which was mounted on the top of a variable-height antenna
                                          tower.
                                       3. The antenna height is varied from one meter to four meters above the
                                          ground to determine the maximum value of the field strength. Both
                                          horizontal and vertical polarizations of the antenna are set to make the
                                          measurement.
                                       4. For each suspected emission, the EUT was arranged to its worst case
                                          and then the antenna was tuned to heights from 1 meter to 4 meters
                                          and the rota table was turned from 0 degrees to 360 degrees to find the
                                          maximum reading.
                                       5. The test-receiver system was set to Peak Detect Function and
                                          Specified Bandwidth with Maximum Hold Mode.
                                       6. If the emission level of the EUT in peak mode was 10dB lower than the
                                          limit specified, then testing could be stopped and the peak values of the
                                          EUT would be reported. Otherwise the emissions that did not have
                                          10dB margin would be re-tested one by one using peak, quasi-peak or
                                          average method as specified and then reported in a data sheet.
      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test environment:                Temp.:        26 C         Humid.:      56%          Press.:      1012mbar
      Test voltage:                    AC 120V, 60Hz
      Test results:                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 15 of 25


                                                                                Report No.: GTS201905000216F01
Measurement data:


7.3.1   Field Strength of The Fundamental Signal
Peak value:
                 Read         Antenna       Cable       Preamp                                   Over
 Frequency                                                             Level      Limit Line
                 Level         Factor       Loss         Factor                                  Limit      polarization
   (MHz)                                                             (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                   (dB)
  2402.00        90.12         27.58         5.39        30.18         92.91       114.00       -21.09        Vertical
  2402.00        87.87         27.58         5.39        30.18         90.66       114.00       -23.34      Horizontal
  2440.00        88.61         27.55         5.43        30.06         91.53       114.00       -22.47        Vertical
  2440.00        86.91         27.55         5.43        30.06         89.83       114.00       -24.17      Horizontal
  2480.00        91.13         27.52         5.47        29.93         94.19       114.00       -19.81        Vertical
  2480.00        88.23         27.52         5.47        29.93         91.29       114.00       -22.71      Horizontal
Average value:
                 Read         Antenna       Cable       Preamp                                   Over
 Frequency                                                             Level      Limit Line
                 Level         Factor       Loss         Factor                                  Limit      polarization
   (MHz)                                                             (dBuV/m)     (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                   (dB)
  2402.00        75.25         27.58         5.39        30.18         78.04        94.00       -15.96        Vertical
  2402.00        73.71         27.58         5.39        30.18         76.50        94.00       -17.50      Horizontal
  2440.00        73.92         27.55         5.43        30.06         76.84        94.00       -17.16        Vertical
  2440.00        71.30         27.55         5.43        30.06         74.22        94.00       -19.78      Horizontal
  2480.00        75.74         27.52         5.47        29.93         78.80        94.00       -15.20        Vertical
  2480.00        73.65         27.52         5.47        29.93         76.71        94.00       -17.29      Horizontal

Note:RBW 3MHz VBW 3MHz PK detector is for PK value , RMS detector is for AV value




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                 Page 16 of 25


    GTS
                                                                                     Report No.: GTS201905000216FO1

7.3.2          Spurious emissions
m         Below 30MHz
          The emission from 9 kHz to 30MHz was pre—tested and found the result was 200B lower than the limit,
          and according to 15.31(0), the test result no need to reported.


m         Below 1GHz


    Mode:                           Transmitting mode                             Test by:               Bill
    Temp./Hum.(%H):                 26°C/56%RH                                    Polarziation:          Horizontal



    m]Lt:-}'vel {dBuV/im})


    70


    60

    50)                                                                                                                ‘7




    30

    20

    10


          30            50                       100                 200                      500                     1000
                                                            Frequency (MHz)
               Freq   Reading         Antenna     Cable        Preanp              Limit      Over
                       level          factor      loss         factor    level     level      linit         Remark
                MHz          dBu¥       dB;‘m     dB            dB        dBu¥      dBu¥/m          dB
           35.624      38. 57           11. 42     0. 62       35. 40    15. 51    40. 00     —24.49            QP
           41.132      39.12            12. 21     0. 67       35. 73    16. 27    40. 00     —23.73             QP
           47. 160     38, 90           12. 27     0. 74       36. 04    15. 87    40. 00     —24.13             QP
           55. 609     37. 54           11.73      0. 82       36. 26    13. 83    40. 00     —26.17            qP
           95. 427     35. 92           11. 52     1. 16       36. 68    11. 92    43. 50     —31.58            qP
          801. 786     33. 91           21. 40     4 . 46      37. 62    22. 15    46. 00     —23.856           QP




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                       Page 17 of 25


 GTS
                                                                                   Report No.: GTS201905000216FO1



 Mode:                       Transmitting mode                                  Test by:               Bill
 Temp./Hum.(%H):             26°C/56%RH                                         Polarziation:          Vertical


 lmLe‘b'el (dBuVim)


 70

 60

 50                                                                                                                  ‘7




 30

 20

 10


      30          50                       100                  200                         500                     1000
                                                       Frequency (MHz)
           Freq   Reading      Antenna      Cable         Preanp                Limnit      Over
                  level        factor       loss          factor     level      level       limit         Remark
            NHz       dBu¥      dB;/m       dB             dB         dBu¥        dBu¥/m          dB
       42. 007    38. 44        12.   22     0.   69      35.   78   15.   57    40.   00   —24.43            QP
       96. 099     38.52        11.   65     1.   16      36.   69   14.   64    43.   50   —28.86             QP
      143.930     41. 21         7.   47     1.   53      37.   04   13.   17    43.   50   —30.33             QP
      155. 910    43.48          8.   05     1.   60      37.   11   16.   02    43.   50   —27.48             QP
      167. 924    45.54          8.   46     1.   67      37.   18   18.   49    43.   50   —25.01            QP
      216.024     40. 14        11.   02     1.   93      37.   35   15.   74    46.   00   —30.26             QP




Global United Technology Services Co., Ltd.
No. 301—309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Bacan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                     Page 18 of 25


                                                                                 Report No.: GTS201905000216F01

     Above 1GHz
Test channel:                                            Lowest channel

Peak value:
                  Read        Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
                  Level        Factor        Loss        Factor                                      Limit   polarization
  (MHz)                                                              (dBuV/m)       (dBuV/m)
                 (dBuV)        (dB/m)        (dB)         (dB)                                       (dB)
    4804.00       35.93         31.78        8.60        32.09         44.22          74.00         -29.78        Vertical
    7206.00      30.92          36.15        11.65        32.00        46.72          74.00         -27.28        Vertical
    9608.00      30.66          37.95        14.14        31.62        51.13          74.00         -22.87        Vertical
 12010.00           *                                                                 74.00                       Vertical
 14412.00           *                                                                 74.00                       Vertical
    4804.00      39.94          31.78         8.60        32.09        48.23          74.00         -25.77       Horizontal
    7206.00      32.55          36.15        11.65        32.00        48.35          74.00         -25.65       Horizontal
    9608.00      29.95          37.95        14.14        31.62        50.42          74.00         -23.58       Horizontal
 12010.00           *                                                                 74.00                      Horizontal
 14412.00       *                                                                     74.00                      Horizontal
Average value:
              Read            Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
              Level            Factor        Loss       Factor                                       Limit   polarization
   (MHz)                                                             (dBuV/m)       (dBuV/m)
             (dBuV)            (dB/m)        (dB)         (dB)                                       (dB)
  4804.00     25.01             31.78        8.60        32.09         33.30          54.00         -20.70        Vertical
    7206.00      19.76         36.15         11.65       32.00         35.56          54.00         -18.44        Vertical
    9608.00      18.92         37.95         14.14       31.62         39.39          54.00         -14.61        Vertical
 12010.00           *                                                                 54.00                       Vertical
 14412.00           *                                                                 54.00                       Vertical
    4804.00      29.08         31.78         8.60        32.09         37.37          54.00         -16.63       Horizontal
    7206.00      21.84         36.15         11.65       32.00         37.64          54.00         -16.36       Horizontal
    9608.00      18.54         37.95         14.14       31.62         39.01          54.00         -14.99       Horizontal
 12010.00           *                                                                 54.00                      Horizontal
 14412.00           *                                                                 54.00                      Horizontal
Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                      Page 19 of 25


                                                                                 Report No.: GTS201905000216F01

Test channel:                                                  Middle channel
Peak value:
                 Read         Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
                 Level         Factor        Loss       Factor                                       Limit   polarization
  (MHz)                                                              (dBuV/m)       (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                       (dB)
  4880.00        35.99          31.85        8.67        32.12         44.39          74.00         -29.61        Vertical
  7320.00        30.96         36.37         11.72       31.89         47.16          74.00         -26.84        Vertical
  9760.00        30.69         38.35         14.25       31.62         51.67          74.00         -22.33        Vertical
 12200.00           *                                                                 74.00                       Vertical
 14640.00           *                                                                 74.00                       Vertical
  4880.00        40.01         31.85         8.67        32.12         48.41          74.00         -25.59       Horizontal
  7320.00        32.60         36.37         11.72       31.89         48.80          74.00         -25.20       Horizontal
  9760.00        29.99         38.35         14.25       31.62         50.97          74.00         -23.03       Horizontal
 12200.00           *                                                                 74.00                      Horizontal
 14640.00       *                                                                     74.00                      Horizontal
Average value:
              Read            Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
              Level            Factor        Loss       Factor                                       Limit   polarization
   (MHz)                                                             (dBuV/m)       (dBuV/m)
             (dBuV)            (dB/m)        (dB)         (dB)                                       (dB)
  4880.00     25.06             31.85        8.67        32.12         33.46          54.00         -20.54        Vertical
  7320.00        19.80         36.37         11.72       31.89         36.00          54.00         -18.00        Vertical
  9760.00        18.96         38.35         14.25       31.62         39.94          54.00         -14.06        Vertical
 12200.00           *                                                                 54.00                       Vertical
 14640.00           *                                                                 54.00                       Vertical
  4880.00        29.15         31.85         8.67        32.12         37.55          54.00         -16.45       Horizontal
  7320.00        21.89         36.37         11.72       31.89         38.09          54.00         -15.91       Horizontal
  9760.00        18.58         38.35         14.25       31.62         39.56          54.00         -14.44       Horizontal
 12200.00           *                                                                 54.00                      Horizontal
 14640.00           *                                                                 54.00                      Horizontal
Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                      Page 20 of 25


                                                                                 Report No.: GTS201905000216F01

Test channel:                                                  Highest channel
Peak value:
                 Read         Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
                 Level         Factor        Loss       Factor                                       Limit   polarization
  (MHz)                                                              (dBuV/m)       (dBuV/m)
                (dBuV)         (dB/m)        (dB)         (dB)                                       (dB)
  4960.00        35.82          31.93        8.73        32.16         44.32          74.00         -29.68        Vertical
  7440.00        30.84         36.59         11.79       31.78         47.44          74.00         -26.56        Vertical
  9920.00        30.59         38.81         14.38       31.88         51.90          74.00         -22.10        Vertical
 12400.00           *                                                                 74.00                       Vertical
 14880.00           *                                                                 74.00                       Vertical
  4960.00        39.80         31.93         8.73        32.16         48.30          74.00         -25.70       Horizontal
  7440.00        32.47         36.59         11.79       31.78         49.07          74.00         -24.93       Horizontal
  9920.00        29.87         38.81         14.38       31.88         51.18          74.00         -22.82       Horizontal
 12400.00           *                                                                 74.00                      Horizontal
 14880.00       *                                                                     74.00                      Horizontal
Average value:
              Read            Antenna        Cable      Preamp                                       Over
Frequency                                                              Level        Limit Line
              Level            Factor        Loss       Factor                                       Limit   polarization
   (MHz)                                                             (dBuV/m)       (dBuV/m)
             (dBuV)            (dB/m)        (dB)         (dB)                                       (dB)
  4960.00     24.95             31.93        8.73        32.16         33.45          54.00         -20.55        Vertical
  7440.00        19.73         36.59         11.79       31.78         36.33          54.00         -17.67        Vertical
  9920.00        18.89         38.81         14.38       31.88         40.20          54.00         -13.80        Vertical
 12400.00           *                                                                 54.00                       Vertical
 14880.00           *                                                                 54.00                       Vertical
  4960.00        29.02         31.93         8.73        32.16         37.52          54.00         -16.48       Horizontal
  7440.00        21.80         36.59         11.79       31.78         38.40          54.00         -15.60       Horizontal
  9920.00        18.50         38.81         14.38       31.88         39.81          54.00         -14.19       Horizontal
 12400.00           *                                                                 54.00                      Horizontal
 14880.00           *                                                                 54.00                      Horizontal
Remarks:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor
2. The emission levels of other frequencies are very lower than the limit and not show in test report.
3. “*”, means this data is the too weak instrument of signal is unable to test.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                      Page 21 of 25


                                                                               Report No.: GTS201905000216F01

7.3.3   Bandedge emissions
        All of the restriction bands were tested, and only the data of worst case was exhibited.
Test channel:                                                   Lowest channel
Peak value:
                 Read       Antenna        Cable      Preamp
Frequency                                                            Level       Limit Line     Over Limit
                 Level       Factor        Loss        Factor                                                  Polarization
  (MHz)                                                            (dBuV/m)      (dBuV/m)         (dB)
                (dBuV)       (dB/m)        (dB)         (dB)
 2310.00         40.76        27.59        5.38         30.18        43.55         74.00          -30.45       Horizontal
 2400.00         55.24        27.58        5.40         30.18        58.04         74.00          -15.96       Horizontal
 2310.00         41.10        27.59        5.38         30.18        43.89         74.00          -30.11         Vertical
 2400.00         57.05        27.58        5.40         30.18        59.85         74.00          -14.15         Vertical
Average value:
                 Read       Antenna        Cable      Preamp
Frequency                                                            Level       Limit Line     Over Limit
                 Level       Factor        Loss        Factor                                                  Polarization
  (MHz)                                                            (dBuV/m)      (dBuV/m)         (dB)
                (dBuV)       (dB/m)        (dB)         (dB)
 2310.00         31.79        27.59        5.38         30.18        34.58         54.00          -19.42       Horizontal
 2400.00         39.90        27.58        5.40         30.18        42.70         54.00          -11.30       Horizontal
 2310.00         31.58        27.59        5.38         30.18        34.37         54.00          -19.63         Vertical
 2400.00         39.94        27.58        5.40         30.18        42.74         54.00          -11.26         Vertical


Test channel:                                                   Highest channel
Peak value:
                  Read       Antenna       Cable       Preamp                                      Over
Frequency                                                             Level       Limit Line
                  Level       Factor       Loss         Factor                                     Limit       Polarization
  (MHz)                                                             (dBuV/m)      (dBuV/m)
                 (dBuV)       (dB/m)        (dB)         (dB)                                      (dB)
 2483.50         42.61         27.53        5.47         29.93        45.68         74.00         -28.32       Horizontal
 2500.00         42.18         27.55        5.49         29.93        45.29         74.00         -28.71       Horizontal
 2483.50         43.10         27.53        5.47         29.93        46.17         74.00         -27.83         Vertical
 2500.00         42.98         27.55        5.49         29.93        46.09         74.00         -27.91         Vertical
Average value:
              Read           Antenna       Cable       Preamp
Frequency                                                            Level        Limit Line      Over
              Level           Factor       Loss        Factor                                                  Polarization
  (MHz)                                                            (dBuV/m)       (dBuV/m)      Limit (dB)
             (dBuV)           (dB/m)        (dB)        (dB)
 2483.50         34.59        27.53         5.47        29.93        37.66          54.00         -16.34       Horizontal
 2500.00         32.89        27.55         5.49        29.93        36.00          54.00         -18.00       Horizontal
 2483.50         35.62        27.53         5.47        29.93        38.69          54.00         -15.31         Vertical
 2500.00         32.64        27.55         5.49        29.93        35.75          54.00         -18.25         Vertical
Remark:
1. Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 22 of 25


                                                                               Report No.: GTS201905000216F01

7.4 20dB Occupy Bandwidth
      Test Requirement:                FCC Part15 C Section 15.249/15.215
      Test Method:                     ANSI C63.10:2013
      Limit:                           Operation Frequency range 2400MHz~2483.5MHz
      Test setup:




      Test Instruments:                Refer to section 6.0 for details
      Test mode:                       Refer to section 5.2 for details
      Test results:                    Pass


Measurement Data
          Test channel                        20dB bandwidth(MHz)                            Result
               Lowest                                 1.210                                  Pass
               Middle                                 1.208                                  Pass
               Highest                                1.205                                  Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 23 of 25


                                                                               Report No.: GTS201905000216F01

Test plot as follows:




                                                  Lowest channel




                                                   Middle channel




                                                  Highest channel




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 24 of 25


                                                                               Report No.: GTS201905000216F01

8      Test Setup Photo
       Reference to the appendix I for details.


9      EUT Constructional Details
      Reference to the appendix II for details.




                                                  ------End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 25 of 25