EC1905030F01_R01_wifi_DFS

FCC ID: 2ATJUCENTRO-8M

Test Report

Download: PDF
FCCID_4340478

&
ECLOLUH



                                FCC RF Test Report
                                                         For

                           DEMOPAD SOFTWARE LIMITED


   Test Standards:                                  PART 15 SUBPART E §15. 407

   Product Description:                             Control and automation


   Tested Model:                                    Centro—8M

   Additional Model No.:                           N/A

   Brand Name:                                      DEMOPAD

   FCC ID:                                          2ATJUCENTRO—8M

   Classification                                   (NI)Unlicensed National Information Infrastructure

   Report No.:                                      EC1905030F01

   Tested Date:                                     2019—05—10 to 2019—05—20

   Issued Date:                                     2019—05—20

                                                     J$                 ;
                                                     [   /////bj '_}/C{/IK‘IY


   Prepared By:
                                                   Tiny Yang/ Engineer


   Approved By:                                      $ oo Ma
                                                    Bacon Wu / hF Manager

                               Hunan Ecloud Testing Technology Co., Ltd.
        Building A1, Changsha E Center, No. 18 Xiangtai Avenue, Liuyang Economic and
                             Technological Development Zone, Hunan, P.R.C
                              Tel.: +86—731—89634887           Fax.: +86—731—89634887

                                               www .hn—ecloud.com



  Note: The test results in this report apply exclusively to the tested model / sample. Without written approval of

  Hunan Ecloud Testing Technology Co., Ltd., the test report shall not be reproduced except in full.


                                                                                         Report No.: EC1905030F01


                                              Report Revise Record
    Report Version                Revise Time                   Issued Date   Valid Version              Notes
          V1.0                            /                     2019.05.20       Valid              Original Report




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                              Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                   Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                         Page 2 of 25


                                                                                                                          Report No.: EC1905030F01




                                                    TABLE OF CONTENTS

1    TEST LABORATORY ................................................................................................................................. 5

     1.1      Test facility ......................................................................................................................................... 5

2    GENERAL DESCRIPTION .......................................................................................................................... 6

     2.1      Applicant ............................................................................................................................................ 6
     2.2      Manufacturer...................................................................................................................................... 6
     2.3      General Description Of EUT .............................................................................................................. 6
     2.4      Modification of EUT ........................................................................................................................... 7
     2.5      Applicable Standards ......................................................................................................................... 7

3    TEST CONFIGURATION OF EQUIPMENT UNDER TEST........................................................................ 8

     3.1      Carrier Frequency and Channel ........................................................................................................ 8
     3.2      Test Mode .......................................................................................................................................... 9
     3.3      Support Equipment ............................................................................................................................ 9
     3.4      Test tool software version .................................................................................................................. 9
     3.5      Test Setup ....................................................................................................................................... 10
     3.6      DFS Detection Thresholds for Master Devices and Client Devices with Radar Detection ............. 11

4    REQUIREMENTS AND PARAMETERS FOR DFS TEST........................................................................ 12

     4.1      Applicability of DFS Requirements .................................................................................................. 12
     4.2      DFS Response requirement values................................................................................................. 14
     4.3      Short Pulse Radar Test Waveforms ................................................................................................ 15
     4.4      Long Pulse Radar Test Waveform .................................................................................................. 16
     4.5      Frequency Hopping Radar Test Waveform ..................................................................................... 16

5    CALIBRATION SETUP AND DFS TEST RESULTS ................................................................................ 17

     5.1      Calibration of Radar Waveform ....................................................................................................... 17
     5.2      In-Service Monitoring: Channel Move Time, Channel Closing Transmission Time and
                Non-Occupancy Period ................................................................................................................. 19

6    LIST OF MEASURING EQUIPMENT........................................................................................................ 24

    APPENDIX A. SETUP PHOTOGRAPHS




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                                                      Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                                                           Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                                                                  Page 3 of 25


                                                                                     Report No.: EC1905030F01


                  Summary of Dynamic Frequency Selection Test
                             Bandwidth
          UNII                  and               Description       Measured           Limit              Result
                              Channel
                                                 Channel Move
                                                                     2.121 s          10 sec               Pass
                                                     Time
                               80MHz                              <200ms +          200 ms +
                                               Channel Closing
                               (CH58)                               46 ms    aggregate of 60 ms over       Pass
                                              Transmission time
                              5290MHz                            (aggregate)  remaining 10 s period
                                               Non-Occupancy No transmission
   UNII Band 2-A
                                               Period and Client or Beacons        30 minutes              Pass
   5250-5350MHz
                                                 Beacon Test       occurred
         &
   UNII Band 2-C                                 Channel Move
                                                                     2.121 s          10 sec               Pass
   5470-5725MHz                                      Time
                               80MHz                              <200ms +          200 ms +
                                               Channel Closing
                              (CH106)                               30 ms    aggregate of 60 ms over       Pass
                                              Transmission time
                              5530MHz                            (aggregate)  remaining 10 s period
                                               Non-Occupancy No transmission
                                               Period and Client or Beacons        30 minutes              Pass
                                                 Beacon Test       occurred


Note: Since the product is client without radar detection function, only Channel Move Time, Channel Closing
Transmission Time and Non-Occupancy Period Test are required to be performed.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                          Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                               Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                     Page 4 of 25


                                                                                 Report No.: EC1905030F01


1 Test Laboratory
1.1 Test facility

CNAS ( accreditation number: L11138 )
Hunan Ecloud Testing Technology Co., Ltd. has obtained the accreditation of China National Accreditation

Service for Conformity Assessment (CNAS).

FCC (Designation number: CN1244 , Test Firm Registration Number:
793308 )
Hunan Ecloud Testing Technology Co., Ltd. has been listed on the US Federal Communications Commission

list of test facilities recognized to perform electromagnetic emissions measurements.

ISED(CAB identifier: CN0012)
Hunan Ecloud Testing Technology Co., Ltd. has been listed on the Wireless Device Testing Laboratories list of

innovation, Science and Economic Development Canada to test to Canadian radio equipment requirements.

A2LA (Certificate Code :                            4895.01 )
Hunan Ecloud Testing Technology Co., Ltd. has been listed by American Association for Laboratory

Accreditation to perform electromagnetic emission measurement.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                      Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                           Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                 Page 5 of 25


                                                                                     Report No.: EC1905030F01


2          General Description
2.1 Applicant
        DEMOPAD SOFTWARE LIMITED
        INFOLAB21 BAILRIGG ROAD LANCASTER LA1 4WA UNITED KINGDOM

2.2 Manufacturer
        DEMOPAD SOFTWARE LIMITED
        INFOLAB21 BAILRIGG ROAD LANCASTER LA1 4WA UNITED KINGDOM

2.3 General Description Of EUT
  Product                                         Control and automation
  Model No.                                       Centro-8M
  Additional No.                                  N/A
  Difference Description                          N/A
  FCC ID                                          2ATJUCENTRO-8M
  HW Version                                      2.0
  SW Version                                      2.6.5
  Power Supply                                    5Vdc (adapter or host equipment)
  Modulation Technology                           256QAM,64QAM, 16QAM, QPSK, BPSK for OFDM
  Modulation Type                                 802.11a/n/ac : OFDM
                                                  U-NII-1:5150~5250MHz
  Operating Frequency                             U-NII-2A:5250~5350MHz
                                                  U-NII-2C:5470~5725MHz
  Antenna Type                                    Integral Antenna with 0dBi gain
  I/O Ports                                       Refer to user’s manual

  Cable Supplied                                  USB cable: Unshielded, detachable, 1.0m



 NOTE:
1. The EUT was powered by the following adapters:

     Adapter
     Brand:                       DYS
     Model:                       DYS152-050200W-K
      Input:                      AC 100-240V, 50/60HZ, 0.45A MAX
      Output:                     DC 5V, 2.0A
      DC Line:                    1.15m, unshield, undetachable

Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                          Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                               Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                     Page 6 of 25


                                                                                 Report No.: EC1905030F01
2. For a more detailed features description, please refer to the manufacturer’s specifications or the user's
   manual.

3. For the test results, the EUT had been tested with all conditions. But only the worst case was shown in
   test report.



2.4 Modification of EUT
        No modifications are made to the EUT during all test items.



2.5 Applicable Standards
        According to the specifications of the manufacturer, the EUT must comply with the
        requirements of the following standards:
               FCC Part 15 Subpart E §15.407
               FCC KDB 905462 D02 UNII DFS Compliance Procedures New Rules v02
               FCC KDB 905462 D03 UNII Clients Without Radar Detection New Rules v01r02




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                       Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                            Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                  Page 7 of 25


                                                                                      Report No.: EC1905030F01


3          Test Configuration of Equipment Under Test
3.1 Carrier Frequency and Channel
        U-NII-1
         CHANNEL               FREQUENCY                   CHANNEL        FREQUENCY
                36                 5180 MHz                         44     5220 MHz
                38                 5190 MHz                         46     5230 MHz
                40                 5200 MHz                         48     5240 MHz
                42                 5210 MHz

        U-NII-2A
         CHANNEL               FREQUENCY                   CHANNEL        FREQUENCY
                52                 5260 MHz                         60     5300 MHz
                54                 5270 MHz                         62     5310 MHz
                56                 5280 MHz                         64     5320 MHz
                58                 5290 MHz

        U-NII-2C
         CHANNEL               FREQUENCY                   CHANNEL        FREQUENCY
               100                 5500 MHz                         112    5560 MHz
               102                 5510 MHz                         116    5580 MHz
               104                 5520 MHz                         132    5660 MHz
               106                 5530 MHz                         134    5670 MHz
               108                 5540 MHz                         136    5680 MHz
               110                 5550 MHz                         140    5700 MHz



        TDWR
         CHANNEL               FREQUENCY                   CHANNEL        FREQUENCY
               118                 5590 MHz                         124    5620 MHz
               120                 5600 MHz                         126    5630 MHz
               122                 5610 MHz                         128    5640 MHz




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                           Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                      Page 8 of 25


                                                                                                  Report No.: EC1905030F01



3.2 Test Mode
 Additional requirements for
                                                  Master Device or Client with                   Client Without Radar
      devices with multiple
                                                           Radar Detection                               Detection
          bandwidth modes
  U-NII Detection Bandwidth and
                                                    All BW modes must be tested                          Not required
   Statistical Performance Check
 Channel Move Time and Channel                       Test using widest BW mode                Test using the widest BW mode
     Closing Transmission Time                                      available                        available for the link
                All other tests                           Any single BW mode                             Not required
Note: Frequencies selected for statistical performance check (Section 7.8.4) should include several
       frequencies within the radar detection bandwidth and frequencies near the edge of the radar detection
       bandwidth. For 802.11 devices it is suggested to select frequencies in each of the bonded 20 MHz
       channels and the channel center frequency.



3.3 Support Equipment
                                                       Model
    Item        Equipment         Trade Name                              FCC ID        Data Cable            Power Cord
                                                        Name
                                                                                                             Unshielded, 1.8
     1.          WLAN AP            Motorola        MX1200YZ 2AF5PMX1200                       N/A
                                                                                                                   m
                                                                                                             shielded cable
                                                                                                              DC O/P 1.8 m
     2.          Notebook            Lenovo             E540             FCC DoC               N/A
                                                                                                             unshielded AC
                                                                                                             I/P cable1.2 m



3.4 Test tool software version
          Item                       Trade Name                            Model Name                       FW Version
           1.                         KEY-SIGHT                        N7607B Signal Studio                    3.0.0.0




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                          Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                               Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                                     Page 9 of 25


                                                                    Report No.: EC1905030F01



3.5 Test Setup
        Master Modes




        Client Modes




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                         Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C              Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                   Page 10 of 25


&
ECLOL                                                                                       Report No.: EC1905030FO01




3.6 DFS Detection Thresholds for Master Devices and Client Devices
    with Radar Detection

Maximum Transmit Power                                              Value (See Notes 1, 2, and 3)

EIRP >z 200 milliwatt                                               —64 dBm
EIRP < 200 milliwatt and power spectral density < 10                —62 dBm
dBm/MHz
EIRP < 200 milliwatt that do not meet the power                     —64 dBm

spectral density requirement

Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test

transmission waveforms to account for variations in measurement equipment. This will ensure that the test
signal is at or above the detection threshold level to trigger a DFS response.
Note3: EIRP is based on the highest antenna gain.
The radar Detection Threshold, lowest antenna gain is the parameter of Interference radar DFS detection
threshold, The Interference Detection Threshold is the ( —62dBm) + (0) [dBil+ 1 dB= —61 dBm.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                  Tel.:+86—731—89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                       Fax.: +86—731—89634887
FCC ID : 2ATJUCENTRO—8M
www.hn—ecloud.com
                                                                                                            Page 11 of 25


                                                                                         Report No.: EC1905030F01

4 Requirements and Parameters for DFS Test
4.1 Applicability of DFS Requirements
        EUT is client and operates as client without radar detection function.
             Table 1: Applicability of DFS Requirements Prior to Use of a Channel
                                                                             Operational Mode
                                                                                  Client
                   Requirement                                                                         Client With
                                                                    Master    Without Radar
                                                                                                    Radar Detection
                                                                                Detection

            Non-Occupancy Period                                     Yes       Not required                 Yes


           DFS Detection Threshold                                   Yes       Not required                 Yes

      Channel Availability Check Time                                Yes       Not required           Not required

          U-NII Detection Bandwidth                                  Yes       Not required                 Yes



              Table 2: Applicability of DFS requirements during normal operation
                                                                             Operational Mode
                                                                                  Client                  Client
                   Requirement
                                                                    Master    Without Radar            With Radar
                                                                                Detection              Detection
           DFS Detection Threshold                                   Yes       Not required                 Yes
   Channel Closing Transmission Time                                 Yes           Yes                      Yes
              Channel Move Time                                      Yes           Yes                      Yes
          U-NII Detection Bandwidth                                  Yes       Not required                 Yes
               Client Beacon Test                                    N/A           Yes                      Yes




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                              Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                   Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                        Page 12 of 25


                                                                                              Report No.: EC1905030F01




                                                                                     Operational Mode
   Additional requirements for devices                                  Master or
                                                                                                          Client
       with multiple bandwidth modes                                   Client With
                                                                                               Without Radar Detection
                                                                     Radar Detection
       U-NII Detection Bandwidth and                                  All BW modes
                                                                                                        Not required
       Statistical Performance Check                                  must be tested
                                                                                                 Test using the widest
     Channel Move Time and Channel                             Test using widest BW mode
                                                                                                  BW mode available
         Closing Transmission Time                                       available
                                                                                                        for the link
                  All other tests                                   Any single BW mode                  Not required
Note
Frequencies selected for statistical performance check should include several frequencies within the radar
detection bandwidth and frequencies near the edge of the radar detection bandwidth. For 802.11 devices it is
suggested to select frequencies in each of the bonded 20 MHz channels and the channel center frequency.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                     Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                          Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                               Page 13 of 25


                                                                                                Report No.: EC1905030F01



4.2 DFS Response requirement values
                             Parameter                                                       Value
         Non-occupancy period                                       Minimum 30 minutes
         Channel Availability Check Time                            60 seconds
         Channel Move Time                                          10 seconds See Note 1.
         Channel Closing Transmission Time                          200 milliseconds + an aggregate of 60 milliseconds over
                                                                    remaining 10 second period. See Notes 1 and 2.
         U-NII Detection Bandwidth                                  Minimum 100% of the 99% power bandwidth
                                                                    See Note 3.
         Note 1: The instant that the Channel Move Time and the Channel Closing Transmission Time begins
         is as follows:
            • For the Short pulse radar Test Signals this instant is the end of the Burst.
            • For the Frequency Hopping radar Test Signal, this instant is the end of the last radar Burst
            generated.
            • For the Long Pulse radar Test Signal this instant is the end of the 12 second period defining the
            radar transmission.
         Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the
         beginning of the Channel Move Time plus any additional intermittent control signals required to
         facilitate Channel changes (an aggregate of 60 milliseconds) during the remainder of the 10 second
         period. The aggregate duration of control signals will not count quiet periods in between
         transmissions.
         Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 is used and for each
         frequency step the minimum percentage of detection is 90%. Measurements are performed with no
         data traffic.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                     Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                          Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                               Page 14 of 25


                                                                                     Report No.: EC1905030F01



4.3 Short Pulse Radar Test Waveforms
        As the EUT is a Client Device with no Radar Detection, only one type radar pulse is required for the
        testing. Radar Pulse type 0 was used in the evaluation of the Client device for the purpose of
        measuring the Channel Move Time and the Channel Closing Transmission Time.


                                                                                    Minimum
                        Pulse
          Radar                                                                   Percentage of          Minimum
                        Width          PRI (µsec)              Number of Pulses
           Type                                                                    Successful              Trials
                        (µsec)
                                                                                    Detection
             0              1              1428                      18               60%                     30



                                          Test A
             1              1                                                         60%                    30
                                          Test B



             2            1-5            150-230                    23-29             60%                     30
             3           6-10            200-500                    16-18             60%                     30
             4           11-20           200-500                    12-16             60%                     30
         Aggregate (Radar Types 1-4)                                                  80%                    120
         Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move
         time, and channel closing time tests.


        Test A: 15 unique PRI values randomly selected from the list of 23 PRI values in Table 5a
        Test B: 15 unique PRI values randomly selected within the range of 518-3066 μsec, with a minimum
        increment of 1 μsec, excluding PRI values selected in Test A


        A minimum of 30 unique waveforms are required for each of the short pulse radar types 2 through 4.
        For short pulse radar type 1, the same waveform is used a minimum of 30 times. If more than 30
        waveforms are used for short pulse radar types 2 through 4, then each additional waveform must also
        be unique and not repeated from the previous waveforms.

        If more than 30 waveforms are used for Short Pulse Radar Type 1, then each additional waveform is
        generated with Test B and must also be unique and not repeated from the previous waveforms in Tests
        A or B.

        The aggregate is the average of the percentage of successful detections of short pulse radar types 1-4.


Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                            Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                 Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                      Page 15 of 25


                                                                                            Report No.: EC1905030F01
4.4 Long Pulse Radar Test Waveform
Radar             Pulse             Chirp             PRI (µsec)    Number of    Number of    Minimum           Minimum
Type              Width             Width                           Pulses per   Bursts       Percentage        Number of
                  (µsec)            (MHz)                           Burst                     of                Trials
                                                                                              Successful
                                                                                              Detection
      5             50-100              5-20          1000-2000        1-3         8-20            80%                30
       The parameters for this waveform are randomly chosen. Thirty unique waveforms are required for the
Long Pulse Radar Type waveforms. If more than 30 waveforms are used for the Long Pulse Radar Type
waveforms, then each additional waveform must also be unique and not repeated from the previous
waveforms.

4.5 Frequency Hopping Radar Test Waveform
Radar             Pulse             PRI (µsec)        Pulses        Hopping      Hopping      Minimum           Minimum
Type              Width                               per           Rate (kHz)   Sequence     Percentage        Number of
                  (µsec)                              Hop                        Length       of                Trials
                                                                                 (msec)       Successful
                                                                                              Detection
      6                 1                333                 9        0.333         300            70%                30
       For the Frequency Hopping Radar Type, the same Burst parameters are used for each waveform. The
hopping sequence is different for each waveform and a 100-length segment is selected from the hopping
sequence defined by the following algorithm:
       The first frequency in a hopping sequence is selected randomly from the group of 475 integer
frequencies from 5250 – 5724 MHz. Next, the frequency that was just chosen is removed from the group and
a frequency is randomly selected from the remaining 474 frequencies in the group. This process continues
until all 475 frequencies are chosen for the set. For selection of a random frequency, the frequencies
remaining within the group are always treated as equally likely.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                   Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                        Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                             Page 16 of 25


                                                                                 Report No.: EC1905030F01


5          Calibration Setup and DFS Test Results
5.1 Calibration of Radar Waveform
5.1.1      Radar Waveform Calibration Procedure
          The Interference Radar Detection Threshold Level is (-62dBm) + (0) [dBi]+ 1 dB= -61dBm that had
          been taken into account the output power range and antenna gain. The following equipment setup
          was used to calibrate the radiated Radar Waveform. A vector signal generator was utilized to
          establish the test signal level for radar type 0. During this process there were no transmissions by
          either the Master or Client Device. The spectrum analyzer was switched to the zero span (Time
          Domain) at the frequency of the Radar Waveform generator. Peak detection was used. The spectrum
          analyzer resolution bandwidth (RBW) and video bandwidth (VBW) were set to 3 MHz to measure the
          type 0 radar waveform. The spectrum analyzer had offset -5.82dB to compensate receiving horn
          antenna gain 10.32dBi and RF cable loss 4.5dB. The vector signal generator amplitude was set so
          that the power level measured at the spectrum analyzer was (-62dBm) + (0) [dBi]+ 1 dB= -61 dBm.
          Capture the spectrum analyzer plots on short pulse radar waveform.

5.1.2      Radar Waveform Calibration Result
                                               <80MHz / 5290 MHz> Radar Type 0

         Radar / DFS detection threshold level and the burst of pulses on the Channel frequency




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                      Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                           Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                Page 17 of 25


                                                                                 Report No.: EC1905030F01



                                               <80MHz / 5530 MHz> Radar Type 0

         Radar / DFS detection threshold level and the burst of pulses on the Channel frequency




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                      Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                           Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                Page 18 of 25


                                                                                        Report No.: EC1905030F01



5.2 In-Service Monitoring: Channel Move Time, Channel Closing
    Transmission Time and Non-Occupancy Period
5.2.1 Limit of In-Service Monitoring
               The EUT has In-Service Monitoring function to continuously monitor the radar signals, If radar is
          detected, it must leave the channel (Shutdown). The Channel Move Time to cease all transmissions
          on the current Channel upon detection of a Radar Waveform above the DFS Detection Threshold
          within 10 sec. The total duration of Channel Closing Transmission Time is comprised of 200
          milliseconds starting at the beginning of the Channel Move Time plus any additional intermittent
          control signals required to facilitate Channel changes (an aggregate of 60 milliseconds) during the
          remainder of the 10 second period. The aggregate duration of control signals will not count quiet
          periods in between transmissions.
               Non-Occupancy Period time is 30 minute during which a Channel will not be utilized after a Radar
          Waveform is detected on that Channel. The non-associated Client Beacon Test is during the 30
          minutes observation time. The EUT should not make any transmissions in the DFS band after EUT
          power up.



5.2.2      Test Procedures
          1.     The radar pulse generator is setup to provide a pulse at frequency that the Master and Client are
                 operating. A type 0 radar pulse with a 1us pulse width and a 1428 us PRI is used for the testing.
          2.     The vector signal generator is adjusted to provide the radar burst (18 pulses) at a level of
                 approximately -62dBm at the antenna of the Master device.
          3.     A trigger is provided from the pulse generator to the DFS monitoring system in order to capture
                 the traffic and the occurrence of the radar pulse.
          4.     A U-NII device operating as a Client Device will associate with the Master at Channel. The
                 MPEG file “TestFile.mpg” specified by the FCC is streamed from the “file computer” through the
                 Master to the Client Device and played in full motion video using Media Player Classic Ver.
                 6.4.8.6 in order to properly load the network for the entire period of the test.
          5.     When a radar Burst with a level equal to the DFS Detection Threshold + 1dB is generated on the
                 Operating Channel of the U-NII device. At time T0 the Radar Waveform generator sends a Burst
                 of pulse of the radar waveform at Detection Threshold + 1dB.
          6.     Observe the transmissions of the EUT at the end of the radar Burst on the Operating Channel.
                 Measure and record the transmissions from the EUT during the observation time (Channel Move
                 Time). One 12 seconds plot is reported for the Short Pulse Radar Types 1. The plot for the Short
                 Pulse Radar Types start at the end of the radar burst. The Channel Move Time will be calculated
                 based on the zoom in 600ms plot of the Short Pulse Radar Type.
Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                              Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                   Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                        Page 19 of 25


                                                                                    Report No.: EC1905030F01


          7.    Measurement of the aggregate duration of the Channel Closing Transmission Time method.
                With the spectrum analyzer set to zero span tuned to the center frequency of the EUT operating
                channel at the radar simulated frequency, peak detection, and max hold, the dwell time per bin is
                given by: Dwell (0.4ms)= S (12000ms) / B (30000); where Dwell is the dwell time per spectrum
                analyzer sampling bin, S is the sweep time and B is the number of spectrum analyzer sampling
                bins. An upper bound of the aggregate duration of the intermittent control signals of Channel
                Closing Transmission Time is calculated by: C (ms)= N X Dwell (0.4 ms); where C is the Closing
                Time, N is the number of spectrum analyzer sampling bins (intermittent control signals) showing
                a U-NII transmission and Dwell is the dwell time per bin.
                  Measure the EUT for more than 30 minutes following the channel move time to verify that no
                  transmissions or beacons occur on this Channel.

5.2.3 Result of Channel Move Time, Channel Closing Transmission Time and
Non-Occupancy Period for Client Beacon Test
Test Mode :            Client without radar detection                 Temperature :         26.3℃
Test Engineer : Victorique Gao                                        Relative Humidity : 47%


    BW / Channel                                Test Item            Test Result          Limit           Pass/Fail

                                         Channel Move Time             2.121 s            < 10s              Pass
                                                                      200ms +
 80MHz / 5290 MHz Channel Closing Transmission Time                                    < 260ms               Pass
                                                                       0.046 s
                                      Non-Occupancy Period            ≥ 30 min         ≥ 30 min              Pass
                                         Channel Move Time             2.121 s            < 10s              Pass
                                                                      200ms +
 80MHz / 5530 MHz Channel Closing Transmission Time                                    < 260ms               Pass
                                                                        0.03 s
                                      Non-Occupancy Period            ≥ 30 min         ≥ 30 min              Pass


     Note: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning
     of the Channel Move Time plus any additional intermittent control signals required to facilitate a Channel
     move (an aggregate of 60 milliseconds) during the remainder of the 10 seconds period. The aggregate
     duration of control signals will not count quiet periods in between transmissions.




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                            Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                 Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                      Page 20 of 25


                                                                                      Report No.: EC1905030F01



5.2.4 Channel Move Time, Channel Closing Transmission Time and Non-Occupancy
Period for Client Beacon Test Plots

                                               <80MHz / 5290 MHz> In-Service Monitoring
                                                        Channel Move Time &
                                              Channel Closing Transmission Time




                                                       Non-Occupancy Period




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                           Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                     Page 21 of 25


                                                                                      Report No.: EC1905030F01




                                               <80MHz / 5530 MHz> In-Service Monitoring
                                                        Channel Move Time &
                                              Channel Closing Transmission Time




                                                       Non-Occupancy Period




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                           Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                     Page 22 of 25


                                                                                  Report No.: EC1905030F01
5.2.5 Data Traffic Plots
                                                     EUT data traffic (5290MHz)




                                                     EUT data traffic (5530MHz)




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                       Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                            Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                 Page 23 of 25


                                                                                          Report No.: EC1905030F01


6          List of Measuring Equipment
                                                                            Calibration
 Instrument Manufacturer                   Model No.           Serial No.                 Due Date          Remark
                                                                               Date
   Spectrum
                        Keysight             N9010A          MY56070788     2019-01-23    2020-01-22      Conducted
   Analyzer
     Signal
  Generator             Keysight             N5182B          MY56200384     2019-04-19    2020-04-18      Conducted
  (Interferer)
     Signal
  Generator             Keysight             N5171B          MY56200661     2019-01-23    2020-01-22      Conducted
   (Blocker)




Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                               Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                    Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                         Page 24 of 25


                                                                                                 Report No.: EC1905030F01




Appendix A. Setup Photographs




--------------------------------------------------------End of the report--------------------------------------------------------
Building A1, Changsha E Center, No. 18 Xiangtai Avenue,                                                         Tel.:+86-731-89634887
Liuyang Economic and Technological Development Zone, Hunan, P.R.C                                              Fax.: +86-731-89634887
FCC ID : 2ATJUCENTRO-8M
www.hn-ecloud.com
                                                                                                                   Page 25 of 25



Document Created: 2019-07-01 01:28:45
Document Modified: 2019-07-01 01:28:45

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC