Test Report

FCC ID: 2ATGY-AWC1052

Test Report

Download: PDF
FCCID_4357113

                                     FCC 47 CFR PART 15 SUBPART C


                                                    TEST REPORT


                                                             For

                                      Charging Stand for Apple Watch

         MODEL NUMBER: AWC1052, AWC1052AW, AWC1052SG, AWC1052XX
            ( X would be any Arabian number or English letter or blank)

                                           FCC ID: 2ATGY-AWC1052

                                    REPORT NUMBER: 4789012724.1-1

                                          ISSUE DATE: June 27, 2019


                                                      Prepared for

                                       Ubio Labs, Inc.
                     2821 Northup Way, Suite 250, Bellevue, WA 98004, USA


                                                      Prepared by

      UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch
 Building 10, Innovation Technology Park, No. 1, Li Bin Road, Song Shan Lake Hi-
     Tech Development Zone Dongguan, 523808, People’s Republic of China
                               Tel: +86 769 22038881
                               Fax: +86 769 33244054
                               Website: www.ul.com




The results reported herein have been performed in accordance with the laboratory’s terms of accreditation. This report
shall not be reproduced except in full without the written approval of the Laboratory. The results in this report apply to the
test sample(s) mentioned above at the time of the testing period only and are not to be used to indicate applicability to other
similar products. This report does not imply that the product(s) has met the criteria for certification.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 2 of 23

                                                   Revision History

 Rev.       Issue Date             Revisions                                                           Revised By
  V0        06/27/2019             Initial Issue




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 3 of 23



                                         Summary of Test Results
          Description of Test Item                                       Standard                           Results

  Power Line Conducted Emission Test                                   FCC 15.207                            PASS

          Radiated Emission Test                                       FCC 15.209                            PASS
               20dB Bandwidth                                          FCC 15.215                            PASS




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                              REPORT NO.: 4789012724.1-1
                                                                                                          Page 4 of 23


                                               TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ...................................................................................... 5

2.     TEST METHODOLOGY .......................................................................................................... 6

3.     FACILITIES AND ACCREDITATION ...................................................................................... 6

4.     CALIBRATION AND UNCERTAINTY ..................................................................................... 7
     4.1.         MEASURING INSTRUMENT CALIBRATION ............................................................ 7
     4.2.         MEASUREMENT UNCERTAINTY ............................................................................. 7

5.     EQUIPMENT UNDER TEST .................................................................................................... 8
     5.1.         DESCRIPTION OF EUT ............................................................................................. 8
     5.2.         TEST MODE............................................................................................................... 8
     5.3.         TEST ENVIRONMENT ............................................................................................... 8
     5.4.         ACCESSORY ............................................................................................................. 9
     5.5.         MEASURING INSTRUMENT LIST ........................................................................... 10

6.     20dB BANDWIDTH TEST ..................................................................................................... 11

7.     EMISSION TEST ................................................................................................................... 13

8.     AC POWER LINE CONDUCTED EMISSIONS ..................................................................... 21




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                                     FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 5 of 23

1. ATTESTATION OF TEST RESULTS
Applicant Information
Company Name:                        Ubio Labs, Inc.
Address:                             2821 Northup Way, Suite 250, Bellevue, WA 98004, USA

Manufacturer Information
Company Name:                        Shenzhen PYS Industrial Co., LTD
Address:                             Floor 3,8,12,Bldg 9#, Lianhua Industrial Zone, Loangyuan
                                     Road, Longhua Street, Longhua District, Shenzhen

EUT Description
EUT Name:                            Charging Stand for Apple Watch
Model:                               AWC1052
Serial Model:                        Please refer to page 8 clause 5.1. Description of EUT
Brand Name:                          /
Sample Status:                       Normal
Sample ID:                           2331442
Sample Received Date:                May 24, 2019
Date of Tested:                      June 3, 2019 ~ June 27, 2019


                                          APPLICABLE STANDARDS
                                STANDARD                                                TEST RESULTS
                 CFR 47 FCC PART 15 SUBPART C                                                 PASS


Tested By:                                                      Checked By:




Denny Huang                                                    Shawn Wen
Project Engineer                                               Laboratory Leader

Approved By:




Stephen Guo
Laboratory Manager




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 6 of 23

2. TEST METHODOLOGY
All tests were performed in accordance with the standard FCC CFR 47 Part 2, FCC CFR 47 Part
15C KDB414788 D01 Radiated Test Site v01 and ANSI C63.10-2013.



3. FACILITIES AND ACCREDITATION
 Test Location           UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                         Building 10, Innovation Technology Park, Song Shan Lake Hi
 Address
                         tech Development Zone, Dongguan, 523808, China
                         A2LA (Certificate No.: 4102.01)
                         UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                         has been assessed and proved to be in compliance with A2LA.
                         FCC (FCC Designation No.: CN1187)
                         UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                         Has been recognized to perform compliance testing on equipment subject
                         to the Commission's Delcaration of Conformity (DoC) and Certification
                         rules
                         IC(Company No.: 21320)
 Accreditation
                         UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
 Certificate
                         has been registered and fully described in a report filed with
                         Industry Canada. The Company Number is 21320.
                         VCCI (Registration No.: G-20019, R-20004, C-20012 and T-20011)
                         UL Verification Services (Guangzhou) Co., Ltd. Song Shan Lake Branch.
                         has been assessed and proved to be in compliance with VCCI, the
                         Membership No. is 3793.
                         Facility Name:
                         Chamber D, the VCCI registration No. is G-20019 and R-20004
                         Shielding Room B , the VCCI registration No. is C-20012 and T-20011

Note:
   1. All tests measurement facilities use to collect the measurement data are located at
      Building 10, Innovation Technology Park, Song Shan Lake Hi tech Development Zone,
      Dongguan, 523808, China
   2. The test anechoic chamber in UL Verification Services (Guangzhou) Co., Ltd.
      Song Shan Lake Branch had been calibrated and compared to the open field sites and the
      test anechoic chamber is shown to be equivalent to or worst case from the open field site.
   3. For below 30MHz, lab had performed measurements at test anechoic chamber and
      comparing to measurements obtained on an open field site. And these measurements
      below 30MHz had been correlated to measurements performed on an OFS.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 7 of 23

4. CALIBRATION AND UNCERTAINTY
 4.1.      MEASURING INSTRUMENT CALIBRATION

The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.


 4.2.      MEASUREMENT UNCERTAINTY

Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                                                   Measurement Frequency
                  Test Item                                                                 K              U(dB)
                                                          Range
    Conducted disturbance at mains
                                                        0.15MHz ~ 30MHz                      2              3.62
           terminals ports
                                                           9kHz-150kHz                       2              3.32
         Radiated disturbance test
                                                          150kHz-30MHz                       2              3.72
        Radiated Emission Test                  30MHz~1GHz               2           4.00
Note: This uncertainty represents an expanded uncertainty expressed at approximately the 95%
confidence level using a coverage factor of k=2.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 8 of 23

5. EQUIPMENT UNDER TEST
 5.1.      DESCRIPTION OF EUT
 EUT Name                    Charging Stand for Apple Watch
 EUT Description             The EUT is a wireless charger.
 Model                       AWC1052
                             AWC1052AW, AWC1052SG, AWC1052XX
 Serial Models
                             ( X would be any Arabian number or English letter or blank)
 Model Defference            All the same except for the model number and color.
 Product Description         Operation Frequency                 326.5kHz
 Modulation Type             MSK
                             Input: DC 9V/2A from Adapter
 Rated input
                             Output: USB 5V/2.4A
 Rated Power                 Maximum 10W
 Antenna type                Coil


 5.2.      TEST MODE

        Config                Test Mode                                       Description
        Mode 1                  Standby                   EUT alone powered by AC/DC adapter
                                                      EUT and apple watch powered by AC/DC adapter,
        Mode 2                 Operating
                                                               USB output with 5V2.4A load



 5.3.         TEST ENVIRONMENT
    Environment Parameter                                   Selected Values During Tests
        Relative Humidity                                                55 ~ 65%
     Atmospheric Pressure:                                                1018Pa
           Temperature                                 TN                                   22 ~ 28°C
                                                       VL                                         /
             Voltage :                                 VN                                     DC 9V
                                                       VH                                         /

Note: VL= Lower Extreme Test Voltage
      VN= Nominal Voltage
      VH= Upper Extreme Test Voltage
      TN= Normal Temperature




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 9 of 23

 5.4.        ACCESSORY
SUPPORT EQUIPMENT


 Item          Equipment                 Brand Name       Model Name                         Series No.
                                                                              Input:110-240V~50/60Hz 0.5A
   1         Wall Charger                    /              CHG1104
                                                                              Output: DC 9V/2.25A
   2          Apple Watch                  Apple                 /                                /
   3          Dummy load                     /                   /                             5V2.4A


I/O CABLES

                                          Connector
 Cable No               Port                               Cable Type         Cable Length(m)             Remarks
                                            Type
                        DC
        1                                    DC                   /                    1.8                    /
                  (wall charger)
        2               DC                   USB                  /                    1.0                    /


EUT ACCESSORY


 Item       Accessory       Brand Name              Model Name                             Description
              Wall                                                           Input:110-240V~50/60Hz 0.5A
  1                                  /                CHG1104
            Charger                                                          Output: DC 9V/2.25A


TEST SETUP

The EUT support wireless charging.

SETUP DIAGRAM FOR TEST




             AC/DC                                          EUT                                         Dummy
             Adapter                                                                                     load
                                                        Apple watch




                          DC Cable                                                  DC Cable




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 10 of 23


 5.5.      MEASURING INSTRUMENT LIST

                                Conducted Emissions
                                      Instrument
Used    Equipment     Manufacturer Model No.        Serial No.                          Last Cal.   Next Cal.
  EMI Test Receiver        R&S         ESR3         101961                            Dec.10,2018 Dec.10,2019
       Two-Line V-
                           R&S        ENV216        101983                            Dec.10,2018 Dec.10,2019
         Network
                                       Software
Used               Description                Manufacturer                               Name             Version
  Test Software for Conducted disturbance       Farad                                  EZ-EMC          Ver. UL-3A1
                                 Radiated Emissions
                                      Instrument
Used    Equipment     Manufacturer Model No.        Serial No.                          Last Cal.   Next Cal.
  MXE EMI Receiver KESIGHT            N9038A     MY56400036                           Dec.10,2018 Dec.10,2019
        Hybrid Log
                           TDK      HLP-3003C       130960                            Sep.17,2018 Sep.17,2021
     Periodic Antenna
      Preamplifier          HP         8447D     2944A09099                           Dec.10,2018 Dec.10,2019
         Loop antenna         Schwarzbeck
                                         1519B          00008      Jan.17, 2019 Jan.17,2022
                                        Software
Used            Description                Manufacturer           Name            Version
  Test Software for Radiated disturbance      Farad             EZ-EMC         Ver. UL-3A1
                                    Other instruments
Used   Equipment       Manufacturer Model No.         Serial No.     Last Cal.   Next Cal.
  Spectrum Analyzer Keysight           N9030A       MY55410512 Dec.10,2018 Dec.10,2019




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 11 of 23

6. 20dB BANDWIDTH TEST
LIMITS

20dB Bandwidth
Intentional radiators operating under the alternative provisions to the general emission limits,
as contained in § 15.215, must be designed to ensure that the 20 dB bandwidth of the
emission, or whatever bandwidth may otherwise be specified in the specific rule section under
which the equipment operates, is contained within the frequency band designated in the rule
section under which the equipment is operated.


TEST PROCEDURE
Connect the UUT to the spectrum analyser and use the following settings:

 Center Frequency              The centre frequency of the channel under test
 Detector                      Peak
 RBW                           1% to 5% of the occupied bandwidth
 VBW                           approximately 3×RBW
 Trace                         Max hold
 Sweep                         Auto couple

Allow the trace to stabilize and measure the maximum width of the emission that is
constrained by the frequencies associated with the two outermost amplitude points (upper and
lower frequencies) that are attenuated by 99%/20 dB relative to the maximum level measured
in the fundamental emission.


TEST SETUP




            EUT                           Spectrum Analyzer




RESULTS




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 12 of 23



                                Frequency                               20dB Bandwidth
                                  (KHz)                                      (Hz)

                                   326.5                                         326




Note: All the modes have been tested, only the worst data record in the report.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 13 of 23

7. EMISSION TEST
LIMITS

  Please refer to FCC §15.205 and §15.209

  Radiation Disturbance Test Limit for FCC (Class B)(9KHz-1GHz)

                    Frequency                        Field Strength                 Measurement Distance
                        (MHz)                      (microvolts/meter)                     (meters)
                   0.009~0.490                        2400/F(KHz)                           300
                   0.490~1.705                       24000/F(KHz)                            30
                    1.705~30.0                             30                                30
                        30~88                             100                                 3
                       88~216                             150                                 3
                      216~960                             200                                 3
                     960~1000                             500                                 3

  Note: 1) At frequencies at or above 30 MHz, measurements may be performed at a distance other
  than what is specified provided: measurements are not made in the near field except where it can
  be shown that near field measurements are appropriate due to the characteristics of the device;
  and it can be demonstrated that the signal levels needed to be measured at the distance
  employed can be detected by the measurement equipment. Measurements shall not be
  performed at a distance greater than 30 meters unless it can be further demonstrated that
  measurements at a distance of 30 meters or less are impractical. When performing
  measurements at a distance other than that specified, the results shall be extrapolated to the
  specified distance using an extrapolation factor of 20 dB/decade (inverse linear-distance for field
  strength measurements; inverse-linear-distance-squared for power density measurements).

  (2) At frequencies below 30 MHz, measurements may be performed at a distance closer than that
  specified in the regulations; however, an attempt should be made to avoid making measurements
  in the near field. Pending the development of an appropriate measurement procedure for
  measurements performed below 30 MHz, when performing measurements at a closer distance
  than specified, the results shall be extrapolated to the specified distance by either making
  measurements at a minimum of two distances on at least one radial to determine the proper
  extrapolation factor or by using the square of an inverse linear distance extrapolation factor (40
  dB/decade). This paragraph (f) shall not apply to Access BPL devices operating below 30 MHz.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 14 of 23


TEST SETUP AND PROCEDURE

Below 30MHz (Loop Antenna)




The setting of the spectrum analyzer

RBW                         200Hz (From 9kHz to 0.15MHz)/ 9KHz (From 0.15MHz to 30MHz)
VBW                         200Hz (From 9kHz to 0.15MHz)/ 9KHz (From 0.15MHz to 30MHz)
Sweep                       Auto
Trace                       Max hold
1. The testing follows the guidelines in ANSI C63.10-2013 and 414788 D01 Radiated Test Site
v01.
2. The EUT was arranged to its worst case and then turntable (from 0 degree to 360 degrees) to
find the maximum reading. A pre-amp and a high pass filter are used for the test in order to get
better signal level. Both horizontal and vertical polarizations of the antenna are set to make the
measurement.
3. The EUT was placed on a turntable with 80cm meter above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the
top of a variable height antenna tower.
5. The radiated emission limits are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated
emission limits in these three bands are based on measurements employing an average detector.
6. For measurement below 1GHz, the initial step in collecting conducted emission data is a
spectrum analyzer peak detector mode pre-scanning the measurement frequency range.
Significant peaks are then marked and then Quasi Peak detector mode re-measured. If the
emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
the peak emission level will be reported. Otherwise, the emission measurement will be repeated
using the quasi-peak detector and reported.
7. Although these tests were performed other than open area test site, adequate comparison
measurements were confirmed against 30m open are test site. Therefore sufficient tests were
made to demonstrate that the alternative site produces results that correlate with the ones of tests
made in an open field based on KDB 414788.

UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 15 of 23

Below 1G and above 30MHz




The setting of the spectrum analyzer

RBW                         120K
VBW                         300K
Sweep                       Auto
Detector                    Peak/QP
Trace                       Max hold
1. The testing follows the guidelines in ANSI C63.10-2013.
2. The EUT was arranged to its worst case and then tune the antenna tower (from 1 m to 4 m)
and turntable (from 0 degree to 360 degrees) to find the maximum reading. A pre-amp and a high
pass filter are used for the test in order to get better signal level. Both horizontal and vertical
polarizations of the antenna are set to make the measurement.
3. The EUT was placed on a turntable with 0.8m above ground.
4. The EUT was set 3 meters from the interference receiving antenna, which was mounted on the
top of a variable height antenna tower.
5. For measurement below 1GHz, the initial step in collecting conducted emission data is a
spectrum analyzer peak detector mode pre-scanning the measurement frequency range.
Significant peaks are then marked and then Quasi Peak detector mode re-measured. If the
emission level of the EUT measured by the peak detector is 3 dB lower than the applicable limit,
the peak emission level will be reported. Otherwise, the emission measurement will be repeated
using the quasi-peak detector and reported.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT NO.: 4789012724.1-1
                                                                                               Page 16 of 23

RESULTS

  FCC PART 15C BELOW 30MHz SPURIOUS EMISSIONS (MODE 1, LOOP ANTENNA FACE ON TO
                       THE EUT, WORST-CASE CONFIGURATION)

                                                   9kHz~ 150kHz




  No.      Frequency         Reading        Correct        Result         Limit        Margin            Remark
             (MHz)           (dBuV)         (dB/m)         (dBuV)        (dBuV)         (dB)
    1          0.0300          63.90         -101.48        -37.58         38.06         -75.64             peak
    2          0.0568          55.86         -101.48        -45.62         32.55         -78.17             peak
    3          0.0860          52.66         -101.52        -48.86         28.93         -77.79             peak
    4          0.0997          53.11         -101.58        -48.47         27.63         -76.10             peak
    5          0.1055          53.57         -101.56        -47.99         27.15         -75.14             peak
    6          0.1102          52.32         -101.55        -49.23         26.76         -75.99             peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply
with AV limit.
       3. All 3 polarizations(Horizontal, Face-on and Face-off) of the loop antenna had been
tested, but only the worst data recorded in the report.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 17 of 23


                                                 150kHz ~ 490kHz




  No.      Frequency         Reading        Correct        Result          Limit        Margin            Remark
             (MHz)           (dBuV)         (dB/m)         (dBuV)         (dBuV)         (dB)
   1           0.2122           60.36        -101.45         -41.09        21.15         -62.24             peak
   2           0.2673           58.56        -101.50         -42.94        19.21         -62.15             peak
   3           0.3268           69.78        -101.53         -31.75        17.39         -49.14             peak
   4           0.3781           55.74        -101.55         -45.81        16.11         -61.92             peak
   5           0.4319           54.48        -101.57         -47.09        14.94         -62.03             peak
   6           0.4781           54.61        -101.59         -46.98        14.03         -61.01             peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply
with AV limit.
       3. All 3 polarizations(Horizontal, Face-on and Face-off) of the loop antenna had been
tested, but only the worst data recorded in the report.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                   REPORT NO.: 4789012724.1-1
                                                                                               Page 18 of 23


                                                  490kHz ~ 30MHz




  No.      Frequency         Reading        Correct        Result         Limit        Margin            Remark
             (MHz)           (dBuV)         (dB/m)         (dBuV)        (dBuV)         (dB)
    1         6.0083           47.13          -61.34        -14.21         29.54         -43.75             peak
    2         8.4282           46.45          -61.37        -14.92         29.54         -44.46             peak
    3         10.6707          46.38          -61.46        -15.08         29.54         -44.62             peak
    4         13.8872          47.06          -61.71        -14.65         29.54         -44.19             peak
    5         16.6320          46.65          -61.79        -15.14         29.54         -44.68             peak
    6         22.7700          48.33          -61.56        -13.23         29.54         -42.77             peak

Note: 1. Measurement = Reading Level + Correct Factor.
       2. If Peak Result complies with AV and QP limit, AV and QP Result are deemed to comply
with AV limit.
       3. All 3 polarizations (Horizontal, Face-on and Face-off) of the loop antenna had been
tested, but only the worst data recorded in the report.

Note: All the modes have been tested, only the worst data record in the report.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 19 of 23


SPURIOUS EMISSIONS 30MHz - 1GHz

 FCC PART15C SPURIOUS EMISSIONS (MODE 2, WORST-CASE CONFIGURATION, HORIZONTAL)




 No.       Frequency         Reading         Correct         Result          Limit         Margin          Remark
             (MHz)           (dBuV)          (dB/m)        (dBuV/m)        (dBuV/m)         (dB)
  1         36.7900           51.46          -17.71          33.75           40.00          -6.25            QP
  2         130.8800          49.59          -19.55          30.04           43.50         -13.46            QP
  3         219.1500          47.81          -16.87          30.94           46.00         -15.06            QP
  4         283.1700          48.12          -14.67          33.45           46.00         -12.55            QP
  5         318.0900          47.03          -13.66          33.37           46.00         -12.63            QP
  6         427.7000          42.58          -11.79          30.79           46.00         -15.21            QP


 Note: 1. Result Level = Read Level + Correct Factor.
       2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
       3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 20 of 23


   FCC PART15C SPURIOUS EMISSIONS (MODE 2, WORST-CASE CONFIGURATION, VERTICAL)




 No.       Frequency         Reading         Correct         Result          Limit         Margin          Remark
             (MHz)           (dBuV)          (dB/m)        (dBuV/m)        (dBuV/m)         (dB)
  1         48.4300           42.97          -18.30          24.67           40.00         -15.33            QP
  2         216.2400          38.40          -16.67          21.73           46.00         -24.27            QP
  3         283.1700          47.50          -14.67          32.83           46.00         -13.17            QP
  4         316.1500          49.61          -13.69          35.92           46.00         -10.08            QP
  5         431.5800          45.84          -11.72          34.12           46.00         -11.88            QP
  6         544.1000          36.08           -9.53          26.55           46.00         -19.45            QP


 Note: 1. Result Level = Read Level + Correct Factor.
       2. If Peak Result complies with QP limit, QP Result is deemed to comply with QP limit.
       3. Test setup: RBW: 120 kHz, VBW: 300 kHz, Sweep time: auto

Note: All the modes had been tested, but only the worst data recoreded in the report.




UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                 REPORT NO.: 4789012724.1-1
                                                                                             Page 21 of 23

8.     AC POWER LINE CONDUCTED EMISSIONS
LIMITS

Please refer to FCC §15.207 (a) .

                                                  (dBuV)
  FREQUENCY (MHz)
                                   Quasi-peak               Average
         0.15 -0.5                   66 - 56 *              56 - 46 *
         0.50 -5.0                     56.00                  46.00
         5.0 -30.0                     60.00                  50.00


TEST SETUP AND PROCEDURE




         40cm                                                                 Receiver

                  EUT
                                      80cm
                                                 AMN
         80cm




The EUT is put on a table of non-conducting material that is 0.8m high. The vertical conducting
wall of shielding is located 40cm to the rear of the EUT. The power line of the EUT is connected
to the AC mains through an Artificial Mains Network (A.M.N.). An EMI Measurement Receiver
(R&S Test Receiver ESR3) is used to test the emissions from both sides of AC line. According to
the requirements in Section 6.2 of ANSI C63.10-2013.Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR Quasi-Peak and
average detector mode. The bandwidth of EMI test receiver is set at 9kHz.
The arrangement of the equipment is installed to meet the standards and operating in a manner,
which tends to maximize its emission characteristics in a normal application.



UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                         Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT NO.: 4789012724.1-1
                                                                                              Page 22 of 23

 TEST RESULTS

                       LINE L RESULTS (MODE 2, WORST-CASE CONFIGURATION)




   No.       Frequency         Reading        Correct        Result         Limit        Margin           Remark
               (MHz)           (dBuV)          (dB)          (dBuV)        (dBuV)         (dB)
    1           0.1500           38.76           9.61          48.37         66.00         -17.63            QP
    2           0.1500           27.86           9.61          37.47         56.00         -18.53           AVG
    3           0.1689           32.90           9.61          42.51         65.01         -22.50            QP
    4           0.1689           22.58           9.61          32.19         55.01         -22.82           AVG
    5           0.2899           18.63           9.60          28.23         60.53         -32.30            QP
    6           0.2899           10.25           9.60          19.85         50.53         -30.68           AVG
    7           0.7417           22.95           9.60          32.55         56.00         -23.45            QP
    8           0.7417           15.24           9.60          24.84         46.00         -21.16           AVG
    9           9.1789           11.88           9.73          21.61         60.00         -38.39            QP
    10          9.1789           7.12            9.73          16.85         50.00         -33.15           AVG
    11          12.0814          6.66            9.78          16.44         60.00         -43.56            QP
    12          12.0814          2.33            9.78          12.11         50.00         -37.89           AVG

Note: 1. Result = Reading +Correct Factor.
      2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
      3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
      4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.
      5. The extension cord/outlet strip was calibrated with the LISN as required by ANSI
 C63.10:2013 Clause 6.2.2.




 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                          Co., Ltd, Song Shan Lake Branch.


                                                                                  REPORT NO.: 4789012724.1-1
                                                                                              Page 23 of 23

                         LINE N RESULTS (MODE 2, WORST-CASE CONFIGURATION)




   No.       Frequency         Reading        Correct        Result         Limit        Margin           Remark
               (MHz)           (dBuV)          (dB)          (dBuV)        (dBuV)         (dB)
    1           0.1539           40.08           9.60          49.68         65.79         -16.11            QP
    2           0.1539           24.26           9.60          33.86         55.79         -21.93           AVG
    3           0.1899           30.54           9.60          40.14         64.04         -23.90            QP
    4           0.1899           19.41           9.60          29.01         54.04         -25.03           AVG
    5           0.2469           21.96           9.60          31.56         61.86         -30.30            QP
    6           0.2469           9.93            9.60          19.53         51.86         -32.33           AVG
    7           0.7522           22.23           9.60          31.83         56.00         -24.17            QP
    8           0.7522           13.26           9.60          22.86         46.00         -23.14           AVG
    9           3.9180           13.13           9.66          22.79         56.00         -33.21            QP
    10          3.9180           6.92            9.66          16.58         46.00         -29.42           AVG
    11          8.8161           15.22           9.74          24.96         60.00         -35.04            QP
    12          8.8161           6.76            9.74          16.50         50.00         -33.50           AVG

Note: 1. Result = Reading +Correct Factor.
      2. If QP Result complies with AV limit, AV Result is deemed to comply with AV limit.
      3. Test setup: RBW: 200 Hz (9 kHz—150 kHz), 9 kHz (150 kHz—30 MHz).
      4. Step size: 80Hz (0.009MHz-0.15MHz), 4 kHz (0.15MHz-30MHz), Scan time: auto.
      5. The extension cord/outlet strip was calibrated with the LISN as required by ANSI
 C63.10:2013 Clause 6.2.2.

 Note: All the modes had been tested, but only the worst data recoreded in the report.



                                              END OF REPORT


 UL Verification Services (Guangzhou) Co., Ltd, Song Shan Lake Branch                      FORM NO: 10-SL-F0035
 This report shall not be reproduced except in full, without the written approval of UL Verification Services (Guangzhou)
                                          Co., Ltd, Song Shan Lake Branch.



Document Created: 2019-07-14 17:20:34
Document Modified: 2019-07-14 17:20:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC