RF exposure

FCC ID: 2ATEV-BL3362T-P

RF Exposure Info

Download: PDF
FCCID_4405001

1. MAXIMUM PERMISSIBLE EXPOSURE (MPE)

FCC ID: 2ATEV-BL3362T-P

1.1 General Information

Client Information
Applicant:                                Hangzhou BroadLink Technology Co., Ltd.
Address of applicant:                     Unit C, Building 1, No.57 Jiang’er Road, Changhe Street,
                                          Binjiang District, Hangzhou, Zhejiang, P.R.China

Manufacturer:                             Hangzhou BroadLink Technology Co., Ltd.
Address of manufacturer:                  Unit C, Building 1, No.57 Jiang’er Road, Changhe Street,
                                          Binjiang District, Hangzhou, Zhejiang, P.R.China

General Description of EUT
Product Name:                             WiFi Module
Trade Name:                               Broadlink
Model No.:                                BL3362T-P
Adding Model(s):                          /
Rated Voltage:                            DC 3.3V

Note: The test data is gathered from a production sample provided by the manufacturer.


Technical Characteristics of EUT
Support Standards:                        802.11b, 802.11g, 802.11n
                                          2412-2462MHz for 802.11b/g/n-HT20
Frequency Range:
                                          2422-2452MHz for 802.11n-HT40
RF Output Power:                          17.79dBm (Conducted)
Type of Modulation:                       DBPSK,BPSK,DQPSK,QPSK,16QAM,64QAM
Data Rate:                                1-11Mbps, 6-54Mbps, up to 150Mbps
                                          11 for 802.11b/g/n-HT20
Quantity of Channels:
                                          7 for 802.11n-HT40
Channel Separation:                       5MHz
Type of Antenna:                          PCB Antenna
Antenna Gain:                             0dBi

Note: The test data is gathered from a production sample provided by the manufacturer.


1.2 Standard Applicable

According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under
the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency
energy level in excess limit for maximum permissible exposure.

(a) Limits for Occupational / Controlled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
              0.3-3.0                614                  1.63                (100)*                    6
              3.0-30               1842/f                4.89/f              (900/f)*                   6
              30-300                 61.4                0.163                  1.0                     6
             300-1500                 /                     /                 F/300                     6
           1500-100000                /                     /                    5                      6


(b) Limits for General Population / Uncontrolled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
             0.3-1.34                614                  1.63                (100)*                   30
              1.34-30               824/f                2.19/f              (180/f)*                  30
              30-300                 27.5                0.073                  0.2                    30
             300-1500                 /                     /                 F/1500                   30
           1500-100000                /                     /                    1                     30
       Note: f = frequency in MHz: * = Plane-wave equivalents power density

1.3 MPE Calculation Method

S = (30*P*G) / (377*R2)
S = power density (in appropriate units, e.g., mw/cm2)
P = power input to the antenna (in appropriate units, e.g., mw)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
  the power gain factor is normally numeric gain.
R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm)


1.4 MPE Calculation Result

Maximum Tune-Up output power: 18 (dBm)
Maximum peak output power at antenna input terminal: 63.1 (mW)
Prediction distance: >20(cm)
Prediction frequency: 2437 (MHz)
Antenna gain: 0(dBi)
Directional gain (numeric gain): 1
The worst case is power density at prediction frequency at 20cm: 0.013(mw/cm2)
MPE limit for general population exposure at prediction frequency: 1 (mw/cm2)



Result: Pass



Document Created: 2019-08-16 16:43:39
Document Modified: 2019-08-16 16:43:39

© 2024 FCC.report