18_BL3353-P RFExp

FCC ID: 2ATEV-BL3353-P

RF Exposure Info

Download: PDF
FCCID_4338469

1. MAXIMUM PERMISSIBLE EXPOSURE (MPE)

1.1 General Information

 Client Information
 Applicant:                            Hangzhou BroadLink Technology Co., Ltd.
 Address of applicant:                 Unit C,Building 1,No.57 Jiang'er Road,Changhe Street,
                                       Binjiang District,Hangzhou,Zhejiang,P.R.China

 Manufacturer:                         Hangzhou BroadLink Technology Co., Ltd.
 Address of manufacturer:              Unit C,Building 1,No.57 Jiang'er Road,Changhe Street,
                                       Binjiang District,Hangzhou,Zhejiang,P.R.China

 General Description of EUT:
 Product Name:                         WiFi Module
 Trade Name:                           /
 Model No.:                            BL3353-P
 Adding Model(s):                      /
 FCC ID:                               2ATEV-BL3353-P
 Rated Voltage:                        DC 3.3V

 Technical Characteristics of EUT:
 Support Standards:                    802.11b, 802.11g, 802.11n-HT20, 802.11n-HT40
                                       2412-2462MHz for 802.11b/g/n-HT20
 Frequency Range:
                                       2422-2452MHz for 802.11n-HT40
 RF Output Power:                      16.84dBm (Conducted)
 Type of Modulation:                   DBPSK,BPSK,DQPSK,QPSK,16QAM,64QAM
 Data Rate:                            1-11Mbps, 6-54Mbps, up to 150Mbps
                                       11 for 802.11b/g/n-HT20
 Quantity of Channels:
                                       7 for 802.11n-HT40
 Channel Separation:                   5MHz
 Type of Antenna:                      PCB Antenna
 Antenna Gain:                         1.2dBi

Note: The test data is gathered from a production sample provided by the manufacturer.



1.2 Standard Applicable

According to §1.1307(b)(1) and KDB 447498 D01 General RF Exposure Guidance v06, system operating under
the provisions of this section shall be operating in a manner that the public is not exposed to radio frequency
energy level in excess limit for maximum permissible exposure.

(a) Limits for Occupational / Controlled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
              0.3-3.0                614                  1.63                (100)*                    6
              3.0-30               1842/f                4.89/f              (900/f)*                   6
              30-300                 61.4                0.163                  1.0                     6
             300-1500                 /                     /                 F/300                     6
           1500-100000                /                     /                    5                      6


(b) Limits for General Population / Uncontrolled Exposure


                                Electric Field      Magnetic Field                              Averaging Times
         Frequency range                                                  Power Density
                                Strength (E)         Strength (H)                                | E |2, | H |2 or
             (MHz)                                                        (S) (mW/cm2)
                                   (V/m)                (A/m)                                      S (minutes)
             0.3-1.34                614                  1.63                (100)*                   30
              1.34-30               824/f                2.19/f              (180/f)*                  30
              30-300                 27.5                0.073                  0.2                    30
             300-1500                 /                     /                 F/1500                   30
           1500-100000                /                     /                    1                     30
       Note: f = frequency in MHz: * = Plane-wave equivalents power density

1.3 MPE Calculation Method

S = (30*P*G) / (377*R2)
S = power density (in appropriate units, e.g., mw/cm2)
P = power input to the antenna (in appropriate units, e.g., mw)
G = power gain of the antenna in the direction of interest relative to an isotropic radiator,
  the power gain factor is normally numeric gain.
R = distance to the center of radiation of the antenna (in appropriate units, e.g., cm)


1.4 MPE Calculation Result


Maximum Tune-Up output power: 17 (dBm)
Maximum peak output power at antenna input terminal: 50.12 (mW)
Prediction distance: >20(cm)
Prediction frequency: 2412 (MHz)
Antenna gain: 1.2 (dBi)
Directional gain (numeric gain): 1.32
The worst case is power density at prediction frequency at 20cm: 0.013(mw/cm2)
MPE limit for general population exposure at prediction frequency: 1 (mw/cm2)



Result: Pass



Document Created: 2019-05-30 17:14:50
Document Modified: 2019-05-30 17:14:50