18_UL2QC10CA-SGR RFExp

FCC ID: 2ATCAUL2QC10CA-SGR

RF Exposure Info

Download: PDF
FCCID_4316408

                                                                            Model: UL20CIICA—SGR




                 Measurement and Test Report
                                              For

                           ALOGIC Corporation Pty Ltd.

           Level 40,140 William Street, Melbourne VIC 3000, Australia



                        FCC ID: 2ATCAULQC10CA—SGR


 FCC Rule(s):                      KDB 680106 D01 VO3

 Product Description:              Ultra Multi Device Wireless & USB Charging Station

 Tested Model:                     UL2GC10CA—SGR

 Report No.:                       WTX19X04026123W—2

 Tested Date:                      2019—04—26

 Issued Date:                      2019—04—28 to 2019—05—20

 Tested By:                        Jason Su / Engineer
                                                                      Ti   4
                                                                     Jflfih’/u

                                                                    FMa—Chan
 Reviewed By:                      Silin Chen / EMC Manager         ahie   nek

 Approved & Authorized By:         Jandy So / PSQ Manager           J”"%W

 Prepared By:
                        Shenzhen SEM Test Technology Co., Ltd.
                     1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                      Bac‘an District, Shenzhen, P.R.C. (518101)
          Tel.: +86—755—33068908   Fax.: +86—755—33063809 Website: wnw.semtest.com.cn



   Note: This test report is limited to the above client company and the product model only. It
   may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.




REPORT NO.: WTXI9X04026 123W—2                   PAGE 1 OF7                            REExposure


                                                                                                                                       Model: UL2QC10CA-SGR


TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................3
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................3
2. RF EXPOSURE TEST REPORT ............................................................................................................................4
   2.1 STANDARD APPLICABLE.........................................................................................................................................4
   2.2 TEST CONDITIONS ..................................................................................................................................................4
   2.3 TEST PROCEDURE ...................................................................................................................................................5
   2.4 TEST RESULT..........................................................................................................................................................5
   2.4 TEST PHOTOS .........................................................................................................................................................7




REPORT NO.: WTX19X04026123W-2                                                            PAGE 2 OF 7                                                       RFExposure


                                                                                     Model: UL2QC10CA-SGR


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

  Client Information
  Applicant:                                    ALOGIC Corporation Pty Ltd.
  Address of applicant:                         Level 40,140 William Street, Melbourne VIC 3000,
                                                Australia

  Manufacturer:                                 CE LINK LIMITED
  Address of manufacturer:                      Building M,LiCheng Technology Industrial
                                                Zone,GongHe Village,ShaJing Town,ShenZhen
                                                City,China

  General Description of EUT
  Product Name:                                 Ultra Multi Device Wireless & USB Charging Station
  Trade Name:                                   ALOGIC
  Model No.:                                    UL2QC10CA-SGR
  Adding Model(s):                              /
                                                A653-0905000I
  Power adapter                                 Input: AC100-240V, 50/60Hz, 1.5A
                                                Output: DC9V, 5000mA

  Note: The test data is gathered from a production sample, provided by the manufacturer.


  Technical Characteristics of EUT
  Frequency Range:                              110~205kHz
  Modulation Type:                              ASK
  Antenna Type:                                 Coil Antenna
  Rated Voltage:                                DC5V/DC 9V (Wireless output)
  Rated Current:                                1A/1.1A (Wireless output)
  Rated Power:                                  5W/10W (Wireless output)




REPORT NO.: WTX19X04026123W-2                           PAGE 3 OF 7                           RFExposure


                                                                                     Moiet uLagcioca.sor


2. RF Exposure Test Report

2.1 Standard Applicable
According to 5 1.1310 system operating under the provisions of this section shall be operating in a manner that
the public is not exposed to radio frequency energy level i excess limit for maximum permissible exposure.

                               Trece 1—Lis ron Mecuou Penussoce Exrosne (UPE)

 Erequency range     [Electrc fieldstrength   Magnetic ield strength      [Po¥er density   Inveraging time
 [ute)               (Vm)                        (Alm)                     (mwicm?)       (minutes)
                                (8) Limits for OccupationallControlled xposure
 b330                                         sn                       18            "d                       &
 ozo                                       Tar                        aoor          sove                      s
 Fozwo                                       ara                      mss              10                     &
 Foo—1 soo                                                                           van                      s
 [1s00—100.000                                                                          s                     s
                                    is for General Population/Uncontroled Exposure
 b3iz                                         en                       18            "d                      zo
 tsez0                                      seur                      Zior          oe                       5o
 Fozwo                                       2s                       sors             o2                    zo
 Foo—1 soo                                                                          ¥1s00                    zo
 [1s00—100.000                                                                         10                    El
    1=fequency in MFtz = Plane—wave equialent power densty

2.2 Test Con

     Test Mode                Description                   Remark                Power Supply Mode
        Tw                      Works                Comnect to wiseless loag    C SY (ith a adapter mpur
                                  orking              ‘omect to wircless loa        ac roviony
                                     .                            .              DCV (with a adapter input
         o                      Working              Comnect to wireless load
                                                                                    ac rovisor)

   Measurement
       .                                                        I5em
     Distance:




Report No: wixtoxomzetaw2                               macea or 7                               RiErponre


                                                                                  Model: UL2QC10CA-SGR



2.3 Test Procedure




a. The measurement probe was placed at test distance(15 cm for A,B,C,D,F and 20 cm for E) which is between
   the edge of the charger and the geometric center of probe.
b. The highest emission level was recorded at the measurement points(A, B, C, D, E, F).
c. The EUT was measured according to the distance of KDB 680106 D01 V03.

2.4 Test Result

The EUT dose comply with item 5.2 of KDB 680106 D01V03

1. Power transfer frequency is less that 1 MHz
     Yes, the device operate in the frequency range from 110kHz to 205kHz.


2. Output power from each primary coil is less than 15 watts
     Yes, the maximum output power of the primary coil is less than 15W.


3. The transfer system includes only single primary and secondary coils. This includes
     charging systems that may have multiple primary coils and clients that are able
     to detect and allow coupling only between individual pairs of coils
     Yes, the client device includes only single primary coils.


4. Client device is inserted in or placed directly in contact with the transmitter
     Yes, Client device is placed directly in contact with the transmitter.


5. Mobile exposure conditions only (portable exposure conditions are not covered by
     this exclusion).
     Yes, It is mobile exposure conditions only.


REPORT NO.: WTX19X04026123W-2                         PAGE 5 OF 7                              RFExposure


                                                                               Model: UL2QC10CA-SGR



6. The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above
    the top surface from all simultaneous transmitting coils are demonstrated to be
    less than 50% of the MPE limit.
    Yes, The EUT field strength levels are less than 50% of the MPE limit, refer to
    test TM1, TM2 list, and the coils can’t transmitted simultaneous.


Test Mode: TM1 (with mobile phone)
                                       Electric Field Emissions
      Test Position             Measure Value (V/m)               Limit(V/m)       50% Limit (V/m)
          Top                          7.65                          614                307
        Bottom                         8.11                          614                307
         Side 1                        7.55                          614                307
         Side 2                        7.65                          614                307
         Side 3                        9.24                          614                307
         Side 4                        8.87                          614                307


                                      Magnetic Field Emissions
      Test Position             Measure Value (A/m)               Limit(A/m)       50% Limit (A/m)
          Top                         0.0852                         1.63               0.815
        Bottom                        0.0841                         1.63               0.815
         Side 1                       0.0898                         1.63               0.815
         Side 2                       0.0725                         1.63               0.815
         Side 3                       0.0765                         1.63               0.815
         Side 4                       0.0712                         1.63               0.815



s




REPORT NO.: WTX19X04026123W-2                      PAGE 6 OF 7                           RFExposure


                                                                                Model: UL2QC10CA-SGR



Test Mode: TM2 (with mobile phone)
                                        Electric Field Emissions
      Test Position             Measure Value (V/m)                Limit(V/m)       50% Limit (V/m)
          Top                           8.62                          614                307
        Bottom                          8.41                          614                307
         Side 1                         8.95                          614                307
         Side 2                         9.58                          614                307
         Side 3                         9.32                          614                307
         Side 4                         7.54                          614                307


                                       Magnetic Field Emissions
      Test Position             Measure Value (A/m)                Limit(A/m)       50% Limit (A/m)
          Top                          0.0832                         1.63               0.815
        Bottom                         0.0841                         1.63               0.815
         Side 1                        0.0933                         1.63               0.815
         Side 2                        0.0711                         1.63               0.815
         Side 3                        0.0756                         1.63               0.815
         Side 4                        0.0769                         1.63               0.815

2.4 Test Photos




                                     ***** END OF REPORT *****




REPORT NO.: WTX19X04026123W-2                       PAGE 7 OF 7                           RFExposure



Document Created: 2019-06-12 14:43:17