18_P27QC10P60-BK RFExp

FCC ID: 2ATCAP27QC10P60-BK

RF Exposure Info

Download: PDF
FCCID_4324746

                                                                             Model: P27QC10P60-BK




                 Measurement and Test Report
                                              For
                           ALOGIC Corporation Pty Ltd
           Level 40,140 William Street, Melbourne VIC 3000, Australia


                        FCC ID: 2ATCAP27QC10P60-BK


 FCC Rule(s):                      KDB 680106 D01 V03

 Product Description:              USB-C Power Bank 27000mAH with Wireless Charger

 Tested Model:                     P27QC10P60-BK

 Report No.:                       WTX19X05029265W-2

 Tested Date:                      2019-05-10 to 2019-05-30

 Issued Date:                      2019-05-30

 Tested By:                        Jason Su / Engineer

 Reviewed By:                      Silin Chen / EMC Manager

 Approved & Authorized By:         Jandy So / PSQ Manager

 Prepared By:
                      Shenzhen SEM Test Technology Co., Ltd.
                     1/F, Building A, Hongwei Industrial Park, Liuxian 2nd Road,
                     Bao'an District, Shenzhen, P.R.C.(518101)
          Tel.: +86-755-33663308 Fax.: +86-755-33663309 Website: www.semtest.com.cn



   Note: This test report is limited to the above client company and the product model only. It
   may not be duplicated without prior permitted by Shenzhen SEM Test Technology Co., Ltd.




REPORT NO.: WTX19X05029265W-2                    PAGE 1 OF 7                            RFExposure


                                                                                                                                         Model: P27QC10P60-BK


TABLE OF CONTENTS
1. GENERAL INFORMATION ...................................................................................................................................3
   1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ...............................................................................3
2. RF EXPOSURE TEST REPORT ............................................................................................................................4
   2.1 STANDARD APPLICABLE.........................................................................................................................................4
   2.2 TEST CONDITIONS ..................................................................................................................................................4
   2.3 TEST PROCEDURE ...................................................................................................................................................5
   2.4 TEST RESULT..........................................................................................................................................................5
   2.4 TEST PHOTOS .........................................................................................................................................................7




REPORT NO.: WTX19X05029265W-2                                                            PAGE 2 OF 7                                                         RFExposure


                                                                                      Model: P27QC10P60-BK


1. GENERAL INFORMATION

1.1 Product Description for Equipment Under Test (EUT)

  Client Information
  Applicant:                                    ALOGIC Corporation Pty Ltd
  Address of applicant:                         Level 40,140 William Street, Melbourne VIC 3000,
                                                Australia

  Manufacturer:                                 SuiChuan CE LINK LIMITED
  Address of manufacturer:                      SuiChuan county industrial park east zone, Ji’an
                                                city,Jiangxi province, China.

  General Description of EUT
                                                USB-C Power Bank 27000mAH with Wireless
  Product Name:
                                                Charger
  Trade Name:                                   ALOGIC
  Model No.:                                    P27QC10P60-BK
  Power supply                                  Battery 3.7V,Wireless Output:DC5V 1A,DC9V 1.1A
  Adding Model(s):                              /

  Note: The test data is gathered from a production sample, provided by the manufacturer.


  Technical Characteristics of EUT
  Frequency Range:                              110~205kHz
  Modulation Type:                              ASK
  Antenna Type:                                 Coil Antenna
  Rated Voltage:                                DC5V /DC9V(Wireless output)
  Rated Current:                                1A/1.1A (Wireless output)
  Rated Power:                                  5W/10W (Wireless output)




REPORT NO.: WTX19X05029265W-2                           PAGE 3 OF 7                             RFExposure


                                                                                     Model: P27QC10P60-BK


2. RF Exposure Test Report

2.1 Standard Applicable

According to §1.1310 system operating under the provisions of this section shall be operating in a manner that
the public is not exposed to radio frequency energy level in excess limit for maximum permissible exposure.




2.2 Test Conditions

     Test Mode                Description                   Remark                  Power Supply Mode
        TM1             Wireless Output (5V1A)                  /                  DC3.7V inside battery
        TM2            Wireless Output (9V1.1A)                 /                  DC3.7V inside battery


    Measurement
                                                               15 cm
     Distance:




REPORT NO.: WTX19X05029265W-2                          PAGE 4 OF 7                                RFExposure


                                                                                   Model: P27QC10P60-BK



2.3 Test Procedure




a. The measurement probe was placed at test distance(15 cm for A,B,C,D,F and 20 cm for E) which is between
   the edge of the charger and the geometric center of probe.
b. The highest emission level was recorded at the measurement points(A, B, C, D, E, F).
c. The EUT was measured according to the distance of KDB 680106 D01 V03.

2.4 Test Result

The EUT dose comply with item 5.2 of KDB 680106 D01V03

1. Power transfer frequency is less that 1 MHz
     Yes, the device operate in the frequency range from 110kHz to 205kHz.


2. Output power from each primary coil is less than 15 watts
     Yes, the maximum output power of the primary coil is less than 15W.


3. The transfer system includes only single primary and secondary coils. This includes
     charging systems that may have multiple primary coils and clients that are able
     to detect and allow coupling only between individual pairs of coils
     Yes, the client device includes only single primary coils.


4. Client device is inserted in or placed directly in contact with the transmitter
     Yes, Client device is placed directly in contact with the transmitter.


5. Mobile exposure conditions only (portable exposure conditions are not covered by
     this exclusion).
     Yes, It is mobile exposure conditions only.


REPORT NO.: WTX19X05029265W-2                         PAGE 5 OF 7                               RFExposure


                                                                          Model: P27QC10P60-BK



6. The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above
   the top surface from all simultaneous transmitting coils are demonstrated to be
   less than 50% of the MPE limit.
   Yes, The EUT field strength levels are less than 50% of the MPE limit, refer to
   test TM1, TM2 list, and the coils can’t transmitted simultaneous.


Test Mode: TM1
                                  Electric Field Emissions
     Test Position         Measure Value (V/m)               Limit(V/m)      50% Limit (V/m)
         Top                      9.25                          614                307
        Bottom                    8.65                          614                307
        Side 1                    9.11                          614                307
        Side 2                    9.69                          614                307
        Side 3                    9.34                          614                307
        Side 4                    8.14                          614                307


                                 Magnetic Field Emissions
     Test Position         Measure Value (A/m)               Limit(A/m)      50% Limit (A/m)
         Top                     0.0865                         1.63              0.815
        Bottom                   0.0911                         1.63              0.815
        Side 1                   0.0932                         1.63              0.815
        Side 2                   0.0851                         1.63              0.815
        Side 3                   0.0836                         1.63              0.815
        Side 4                   0.0811                         1.63              0.815




REPORT NO.: WTX19X05029265W-2                 PAGE 6 OF 7                           RFExposure


                                                                           Model: P27QC10P60-BK



Test Mode: TM2
                                   Electric Field Emissions
     Test Position         Measure Value (V/m)                Limit(V/m)      50% Limit (V/m)
         Top                      10.21                          614                307
        Bottom                     9.27                          614                307
        Side 1                     9.11                          614                307
        Side 2                     9.36                          614                307
        Side 3                     9.55                          614                307
        Side 4                     9.17                          614                307


                                  Magnetic Field Emissions
     Test Position         Measure Value (A/m)                Limit(A/m)      50% Limit (A/m)
         Top                      0.0821                         1.63              0.815
        Bottom                    0.0932                         1.63              0.815
        Side 1                    0.0987                         1.63              0.815
        Side 2                    0.0941                         1.63              0.815
        Side 3                    0.0904                         1.63              0.815
        Side 4                    0.0826                         1.63              0.815

2.4 Test Photos




                                ***** END OF REPORT *****




REPORT NO.: WTX19X05029265W-2                  PAGE 7 OF 7                           RFExposure



Document Created: 2019-06-19 09:34:39
Document Modified: 2019-06-19 09:34:39

© 2024 FCC.report