Test reports

FCC ID: 2AT92-TSL-A03

Test Report

Download: PDF
FCCID_4437040

                                           Test Report

                                                 FCC ID: 2AT92-TSL-A03


                                               Date of issue: Sept. 02, 2019

    Report Number:                      MTi19070909-5E1


    Sample Description:                 Car Fast Wireless Charger


    Model(s):                           TSL-A03


    Applicant:                          Shenzhen Tianli Electronics Co., Ltd.


    Address:                            7th Floor, Building G, Debaoli Industrial Zone, Jihua Road, Putian
                                        Street, Longgang District, Shenzhen



    Date of Test:                       Aug. 08, 2019 – Aug. 16, 2019




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                                      - Page 2 of 26 -                                Report No.: MTi19070909-5E1


                                                            Table of Contents
1       GENERAL INFORMATION ...................................................................................................................... 4
    1.1     FEATURE OF EQUIPMENT UNDER TEST (EUT) ............................................................................................ 4
    1.2     TEST MODE............................................................................................................................................. 4
    1.3     EUT TEST SETUP .................................................................................................................................... 5
    1.4     ANCILLARY EQUIPMENT ........................................................................................................................... 5
    1.5     MEASUREMENT UNCERTAINTY ................................................................................................................. 5
2       SUMMARY OF TEST RESULT ................................................................................................................ 6
    2.1     OPERATION CHANNEL LIST ....................................................................................................................... 6
    2.2     TEST CHANNEL ....................................................................................................................................... 6
3       TEST FACILITIES AND ACCREDITATIONS ........................................................................................... 7
    3.1     TEST LABORATORY .................................................................................................................................. 7
    3.2     ENVIRONMENTAL CONDITIONS .................................................................................................................. 7
    3.3     MEASUREMENT UNCERTAINTY .................................................................................................................. 7
    3.4     TEST SOFTWARE ..................................................................................................................................... 7
4       LIST OF TEST EQUIPMENT.................................................................................................................... 8
5       TEST RESULTS ....................................................................................................................................... 8
    5.1 ANTENNA REQUIREMENT.......................................................................................................................... 9
       5.1.1 Standard requirement .................................................................................................................. 9
       5.1.2 EUT Antenna ................................................................................................................................ 9
    5.2 CONDUCTED EMISSION .......................................................................................................................... 10
       5.2.1 Limits .......................................................................................................................................... 10
       5.2.2 Test Procedures ......................................................................................................................... 10
       5.2.3 Test Setup .................................................................................................................................. 10
       5.2.4 Test Result ................................................................................................................................. 10
    5.3 RADIATED EMISSION .............................................................................................................................. 15
       5.3.1 Limits .......................................................................................................................................... 15
       5.3.2 Test Procedures ......................................................................................................................... 16
       5.3.3 Test Setup .................................................................................................................................. 17
       5.3.4 Test Result ................................................................................................................................. 17
    5.4 OCCUPIED BANDWIDTH .......................................................................................................................... 22
       5.4.1 Test method ............................................................................................................................... 22
       5.4.2 Test result ................................................................................................................................... 22
PHOTOGRAPHS OF THE TEST SETUP ....................................................................................................... 24
PHOTOGRAPHS OF THE EUT ...................................................................................................................... 26




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 3 of 26 -                     Report No.: MTi19070909-5E1




                              Test Result Certification
Applicant’s name:                 Shenzhen Tianli Electronics Co., Ltd.


                                  7th Floor, Building G, Debaoli Industrial Zone, Jihua Road, Putian
Address:
                                  Street, Longgang District, Shenzhen


Manufacture's name:               Shenzhen Tianli Electronics Co., Ltd.


                                  7th Floor, Building G, Debaoli Industrial Zone, Jihua Road, Putian
Address:
                                  Street, Longgang District, Shenzhen


Product name:                     Car Fast Wireless Charger


Trademark:                        SROTEK


Model name:                       TSL-A03


Standards:                        FCC Part 15C


Test Procedure:                   ANSI C63.10-2013

This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results
show that the equipment under test (EUT) is in compliance with the FCC requirements. And it is
applicable only to the tested sample identified in the report.


                       Tested by:


                                             Demi Mu                                            Aug. 16, 2019


                  Reviewed by:


                                             Blue Zheng                                         Sept. 02, 2019

                   Approved by:

                                             Smith Chen                                         Sept. 02, 2019



Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 4 of 26 -                     Report No.: MTi19070909-5E1

1 GENERAL INFORMATION
1.1 Feature of equipment under test (EUT)

    Product name:                         Car Fast Wireless Charger

    Model name:                           TSL-A03

    Model difference:                     N/A

    Operation frequency:                  115–205 kHz

    Modulation type:                      Load modulation

    Antenna type:                         Coil Antenna

    Power supply:                         DC 5V/9V from adapter

    Battery:                              N/A

    Adapter information:                  N/A

1.2 Test mode
To investigate the maximum EMI emission characteristics generates from EUT, the test system was
pre-scanning tested base on the consideration of following EUT operation mode or test
configuration mode which possible have effect on EMI emission level. Each of these EUT operation
mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

                           Test mode                                                   Description
                            Mode 1                                                    Charging+TX

Note1: The test modes were carried out for all operation modes. The final test mode of the EUT was
the worst test mode for EMI, and its test data was showed.
Note2: EUT is tested under full load and belongs to the worst mode.
Note3: The product supports three coils. It can work with any single coil or double coils, but not with
three coils. The report only shows the worst mode: double coil. The 5V and 9V operating voltages
have been tested and the results show that the 9V operating voltage data is the worst, and the
report only shows the worst mode.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 5 of 26 -                     Report No.: MTi19070909-5E1




1.3 EUT test setup
See photographs of the test setup in the report for the actual setup and connections between EUT
and support equipment.

1.4 Ancillary equipment
           Equipment                         Model                     S/N                  Manufacturer
                                                                                       Huizhou Dongyang Yienbi
             Adapter                     EQ-24BCN                        /
                                                                                         Electronics Co., Ltd.
               Load                             /                        /                         /

1.5 Measurement Uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     Conducted emission(150kHz~30MHz)                            ± 2.5 dB
     Radiated emission(30MHz~1GHz)                               ± 4.2 dB
     Radiated emission (above 1GHz)                              ± 4.3 dB
     Temperature                                                 ±1 degree
     Humidity                                                    ±5 %




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 6 of 26 -                     Report No.: MTi19070909-5E1




2 SUMMARY OF TEST RESULT
        Item                  FCC Part No.                            Description of Test                      Result

          1                FCC PART 15.203                           Antenna requirement                        Pass

          2                FCC PART 15.207                           Conducted emission                         Pass

          3                FCC PART 15.209                            Radiated emission                         Pass

          4                 FCC Part 15.215                             20dB bandwidth                          Pass


1.6 Operation channel list
Channel List
                     Channel                                             Frequency (kHz)
                       Low                                                    115
                      Middle                                                  125
                       High                                                   205

1.7 Test channel
                     Channel                                             Frequency (kHz)
                      Middle                                                  125




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 7 of 26 -                     Report No.: MTi19070909-5E1




3 TEST FACILITIES AND ACCREDITATIONS
4.1 Test laboratory

     Test Laboratory                     Shenzhen Microtest Co., Ltd
                                         No.102A & 302A, East Block, Hengfang Industrial Park, Xingye
     Location
                                         Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China
     FCC Registration No.:               448573

4.2 Environmental conditions

     Temperature:                      15ºC~35ºC
     Humidity                          20%~75%
     Atmospheric pressure              98kPa~101kPa


4.3 Measurement uncertainty
Measurement Uncertainty for a Level of Confidence of 95 %, U=2xUc(y)

     RF frequency                                                1 x 10-7
     RF power, conducted                                         ± 1 dB
     Conducted emission(150kHz~30MHz)                            ± 2.5 dB
     Radiated emission(30MHz~1GHz)                               ± 4.2 dB
     Radiated emission (above 1GHz)                              ± 4.3 dB
     Temperature                                                 ±1 degree
     Humidity                                                    ±5 %

4.4 Test software
         Software
                                    Manufacturer                            Model                              Version
          Name
                                    Shenzhen JS
     RF Test System                tonscend co., ltd                      JS1120-3                          2.5.77.0418




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 8 of 26 -                       Report No.: MTi19070909-5E1




4 LIST OF TEST EQUIPMENT
 Equipment                                   Manufactu                               Serial       Calibration
                  Equipment Name                                  Model                                             Due date
    No.                                         rer                                   No.            date
                                             Rohde&sch
  MTI-E004        EMI Test Receiver                                ESPI7            100314        2018/10/09       2019/10/08
                                               warz
                  TRILOG
                                             schwarabe
  MTI-E006        Broadband                                     VULB 9163          9163-872       2018/10/15       2020/10/14
                                                 ck
                  Antenna
                                             Hewlett-Pa                            3113A061
  MTI-E014        amplifier                                        8447D                          2018/10/09       2019/10/08
                                               ckard                                  50
                  Single path vehicle        Schwarzbe
  MTI-E036                                                     NNBM 8124             01175        2018/10/09       2019/10/08
                  AMN(LISN)                     ck
                  Low noise active
                                             Schwarzbe
  MTI-E038        vertical monopole                            VAMP 9243              #565        2018/10/16       2019/10/15
                                                ck
                  antenna
                                             Schwarzbe
  MTI-E039        Biconical antenna                             BBA 9106              #164        2018/10/15       2019/10/14
                                                ck

                  MXG Vector Signal                                                MY49060
  MTI-E041                                      Agilent           N5182A                          2019/04/16       2020/04/15
                  Generator                                                          455
                  ESG Series Analog                                                GB40051
  MTI-E042                                      Agilent           E4421B                          2019/05/21       2020/05/20
                  signal generator                                                   240
                  Thermometer clock
  MTI-E044                                         -               HTC-1                /         2019/04/17       2020/04/16
                  humidity monitor
                  Log Periodic               Schwarzbe
  MTI-E062                                                    VUSLP 9111B             #312        2018/04/11       2020/04/10
                  Antenna                       ck
                  Log Periodic Dipole        ETS-LIND
  MTI-E063                                                         3148B           00224524       2018/04/11       2020/04/10
                  Array Antenna                GREN
  MTI-E065        Amplifier                    EMtrace            RP06A              00117        2019/04/29       2020/04/28

                  Comprehensive              Rohde&sch
  MTI-E066                                                       CMW500             149155        2019/04/16       2020/04/15
                  test instrument              warz
                  PXA Signal                                                       MY51350
  MTI-E071                                      Agilent           N9030A                          2018/10/25       2019/10/24
                  Analyzer                                                           296
                                             Rohde&sch
  MTI-E076        EMI Test Receiver                               ESIB26            100273        2019/04/16       2020/04/15
                                               warz
                  Synthesized                                                      3610A019
  MTI-E078                                      Agilent           83752A                          2019/04/16       2020/04/15
                  Sweeper                                                             57
                                                                                   MY40027
  MTI-E079        DC Power Supply               Agilent           E3632A                          2019/04/16       2020/04/15
                                                                                     695
                  Artificial mains                                                ES391180
  MTI-E093                                      3ctest           LISN J50                         2019/04/16       2020/04/15
                  network                                                            5
                                         Space-Dtro EWLNA0118G
  MTI-E096        Power amplifier                                        1852001     2019/04/29 2020/04/28
                                           niccs            -P40
                                          SOLAR
  MTI-E097      Current Probe            ELECTRO          9207-1        220095-1 2019/04/17 2020/04/16
                                         NICS CO.
                                          SOLAR
  MTI-E098      Loop Sensor              ELECTRO          7334-1        220095-2 2019/04/21 2020/04/20
                                         NICS CO.
 Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to
 international system unit (SI).



Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 9 of 26 -                     Report No.: MTi19070909-5E1

5 TEST RESULTS
4.5 Antenna requirement
5.1.1 Standard requirement
15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device
5.1.2 EUT Antenna
The EUT antenna is Coil Antenna. It comply with the standard requirement. In case of replacement
of broken antenna the same antenna type must be used.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 10 of 26 -                     Report No.: MTi19070909-5E1


4.6 Conducted emission
5.1.3 Limits
For the following equipment, when designed to be connected to the public utility (AC) power line the
radio frequency voltage that is conducted back onto the AC power line on any frequency or
frequencies shall not exceed the limits in the following tables. Compliance with the provisions of this
paragraph shall be based on the measurement of the radio frequency voltage between each power
line and ground at the power terminal using a 50 μH/50 ohms line impedance stabilization network
(LISN).

               Frequency                                                Conducted limit (dBμV)
                 (MHz)                                     Quasi-peak                                  Average
                 0.15 -0.5                                   66 - 56 *                                 56 - 46 *
                   0.5 -5                                        56                                        46
                5 -30                               60                               50
Note: the limit of " * " marked band means the limitation decreases linearly with the logarithm of the
frequency in the range.
5.1.4 Test Procedures
The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to the
power mains through a line impedance stabilization network (LISN). All other support equipment
powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the
measuring instrument.
Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
forth in the center forming a bundle 30 to 40 cm long.
I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall length
shall not exceed 1 m.
LISN is at least 80 cm from nearest part of EUT chassis.
For the actual test configuration, please refer to the related Item – photographs of the test setup.
5.1.5 Test Setup




5.1.6 Test Result




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 11 of 26 -                     Report No.: MTi19070909-5E1



EUT:                Car Fast Wireless Charger                           Model Name:                 TSL-A03

Pressure:           101kPa                                              Phase:                      L

Test voltage:       DC 9V from adapter AC 120V/60Hz                     Test mode:                  Mode 1




 Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 12 of 26 -                     Report No.: MTi19070909-5E1



EUT:             Car Fast Wireless Charger                                 Model Name:            TSL-A03

Pressure:        101kPa                                                    Phase:                 N

Test voltage: DC 9V from adapter AC 120V/60Hz                              Test mode:             Mode 1




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 13 of 26 -                     Report No.: MTi19070909-5E1



EUT:                Car Fast Wireless Charger                           Model Name:               TSL-A03

Pressure:           101kPa                                              Phase:                    L

Test voltage:       DC 9V from adapter AC 240V/60Hz                     Test mode:                Mode 1




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 14 of 26 -                     Report No.: MTi19070909-5E1



EUT:                Car Fast Wireless Charger                           Model Name:               TSL-A03

Pressure:           101kPa                                              Phase:                    N

Test voltage:       DC 9V from adapter AC 240V/60Hz                     Test mode:                Mode 1




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 15 of 26 -                     Report No.: MTi19070909-5E1




4.7 Radiated emission
5.1.7 Limits
In case the emission fall within the restricted band specified on 15.205(a), then the 15.209(a) limit in
the table below has to be followed.
             Frequencies                      Field Strength           Measurement Distance
                 (MHz)                      (micorvolts/meter)                  (meters)
             0.009~0.490                       2400/F(KHz)                        300
             0.490~1.705                      24000/F(KHz)                         30
             1.705~30.0                             30                             30
                30~88                              100                              3
                88~216                             150                              3
               216~960                             200                              3
              Above 960                            500                              3

LIMITS OF RADIATED EMISSION MEASUREMENT (Above 1000MHz)

                                                                          Class B (dBuV/m) (at 3M)
                FREQUENCY (MHz)
                                                                       PEAK                           AVERAGE
                      Above 1000                                         74                                54
Notes:
  The limit for radiated test was performed according to FCC PART 15C.
  The tighter limit applies at the band edges.
  Emission level (dBuV/m)=20log Emission level (uV/m).

  FREQUENCY RANGE OF RADIATED MEASUREMENT (For unintentional radiators)

      Highest frequency generated or
     Upper frequency of measurement
                                                                                Range (MHz)
     used in the device or on which the
      device operates or tunes (MHz)
                   Below 1.705                                                         30
                    1.705 – 108                                                      1000
                     108 – 500                                                       2000
                    500 – 1000                                                5000
                                                          th
                                                         5 harmonic of the highest frequency or 40 GHz,
                    Above 1000
                                                                      whichever is lower

          Spectrum Parameter                                                   Setting
              Attenuation                                                        Auto
            Start Frequency                                                   1000 MHz
            Stop Frequency                                              10th carrier harmonic
     RB / VB (emission in restricted
                                                     1 MHz / 1 MHz for Peak, 1 MHz / 10Hz for Average
                  band)

           Receiver Parameter                                             Setting
                Attenuation                                                Auto
          Start ~ Stop Frequency                                9kHz~150kHz / RB 200Hz for QP
          Start ~ Stop Frequency                                150kHz~30MHz / RB 9kHz for QP


Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 16 of 26 -                     Report No.: MTi19070909-5E1

          Start ~ Stop Frequency                             30MHz~1000MHz / RB 120kHz for QP
5.1.8 Test Procedures
a.   The measuring distance of at 3 m shall be used for measurements at frequency up to 25GHz.
     For frequencies above 1GHz, any suitable measuring distance may be used.

b.   The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3 meter
     semi-chamber test. The table was rotated 360 degrees to determine the position of the highest
     radiation.

c.   The height of the equipment or of the substitution antenna shall be 0.8m; above 1GHz, the
     height was 1.5m, the height of the test antenna shall vary between 1 m to 4 m. Both horizontal
     and vertical polarizations of the antenna are set to make the measurement.

d.   The initial step in collecting conducted emission data is a spectrum analyzer peak detector
     mode pre-scanning the measurement frequency range. Significant peaks are then marked and
     then Quasi Peak detector mode re-measured.

e.   If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
     EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
     performed.

f.   For the actual test configuration, please refer to the related Item –EUT Test Photos.

g.   For the radiated emission test above 1GHz:
     Place the measurement antenna away from each area of the EUT determined to be a source of
     emissions at the specified measurement distance, while keeping the measurement antenna
     aimed at the source of emissions at each frequency of significant emissions, with polarization
     oriented for maximum response.

h.   The measurement antenna may have to be higher or lower than the EUT, depending on the
     radiation pattern of the emission and staying aimed at the emission source for receiving the
     maximum signal. The final measurement antenna elevation shall be that which maximizes the
     emissions. The measurement antenna elevation for maximum emissions shall be restricted to a
     range of heights of from 1 m to 4 m above the ground or reference ground plane.

Note: Both horizontal and vertical antenna polarities were tested and performed pretest to three
orthogonal axis. The worst case emissions were reported.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 17 of 26 -                     Report No.: MTi19070909-5E1




5.1.9 Test Setup
Radiated Emission Test-Up Frequency Below 30MHz




Radiated Emission Test-Up Frequency 30MHz~1GHz




5.1.10     Test Result
Note1: The product supports three coils. It can work with any single coil or double coils, but not with
three coils. The report only shows the worst mode: double coil. The 5V and 9V operating voltages
have been tested and the results show that the 9V operating voltage data is the worst, and the
report only shows the worst mode.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 18 of 26 -                     Report No.: MTi19070909-5E1

Frequency range (9kHz – 30MHz)

  EUT:                 Car Fast Wireless Charger             Model Name:                    TSL-A03
  Pressure:            101kPa                                Test mode:                     Mode 1
  Test voltage:        DC 9V from adapter AC 120V/60Hz




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 19 of 26 -                     Report No.: MTi19070909-5E1



   EUT:                Car Fast Wireless Charger Model Name:                               TSL-A03
   Pressure:           101kPa                               Test mode:                     Mode 1
   Test voltage: DC 9V from adapter AC 120V/60Hz




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                       - Page 20 of 26 -                     Report No.: MTi19070909-5E1

 Frequency range (30MHz – 1GHz)

EUT:               Car Fast Wireless Charger                      Model Name :                      TSL-A03

Pressure:          101kPa                                         Polarization:                     Vertical

Test voltage:      DC 9V from adapter AC 120V/60Hz Test mode:                                       Mode 1




 Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 21 of 26 -                     Report No.: MTi19070909-5E1



  EUT:                Car Fast Wireless Charger                         Model Name:             TSL-A03
  Pressure:           101kPa                                            Polarization:           Horizontal
  Test voltage: DC 9V from adapter AC 120V/60Hz                         Test mode:              Mode 1




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 22 of 26 -                     Report No.: MTi19070909-5E1

4.8 Occupied bandwidth
5.1.11     Test method
Use the following spectrum analyzer settings:
Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
RBW ≥1% of the 20 dB bandwidth
VBW ≥RBW
Sweep = auto
Detector function = peak
Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the marker-delta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99%
occupied bandwidth of the emission.
5.1.12     Test result

                                                                                                        99% occupied
                                                                       20dB emission
         Coil Ant                    Frequency (kHz)                                                      bandwidth
                                                                      bandwidth (kHz)
                                                                                                            (kHz)
         Coil Ant1                           125                             8.094                          6.916
         Coil Ant2                           125                             8.161                            6.956
         Coil Ant3                           125                             8.100                            6.910

Test plots as below:




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 23 of 26 -                     Report No.: MTi19070909-5E1




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 24 of 26 -                     Report No.: MTi19070909-5E1


Photographs of the Test Setup
                                                    Radiated emission




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 25 of 26 -                     Report No.: MTi19070909-5E1



                                                   Conducted emission




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                      - Page 26 of 26 -                     Report No.: MTi19070909-5E1


Photographs of the EUT
See the APPENDIX 1: EUT PHOTO in the report No.: MTi19070909-5E1-1.


                                              ----END OF REPORT----




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China



Document Created: 2019-09-06 18:48:41
Document Modified: 2019-09-06 18:48:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC