RF Exposure

FCC ID: 2AT2K-SUVIE01

RF Exposure Info

Download: PDF
FCCID_4421398

                                                                                                                                            FCC ID: 2AT2K-SUVIE01

                                                   MPE Calculation : WLAN
                                                                                                                                                      Maximum power
                                     Frequency range         Max Target Power           ANT Gain             Maximum EIRP            Maximum EIRP                      Requriment
     RF function or Mode                                                                                                                                 density
                                           (MHz)                      (dBm)               (dBi)                   (dBm)                  (mW)                     2
                                                                                                                                                                             2
                                                                                                                                                                       (mW/cm )
                                                                                                                                                        (mW/cm )
           802.11b               2412.00     ~     2462.00            11.50               3.03                    14.53                 28.379            0.0057         1.000

           802.11g               2412.00     ~     2462.00            11.00               3.03                    14.03                 25.293           0.0050          1.000
        802.11n(HT20)            2412.00     ~     2462.00            9.00                3.03                    12.03                 15.959           0.0040          1.000
                                             ~
                                             ~
                                             ~

                                             ~

                                             ~
                                             ~
Note: Refer to the operation description for the max tune-up power.



The EUT will only be used with a separation of 20 centimeters or greater between the antenna and the body of the user.
The MPE sample calculation for this exposure is shown below.
                                   ▪S=       EIRP / ( 4 R2 π )                                              - Note
                                     =         28.3792 / ( 4 X 202 X π )                                    S= Maximum power density(mW/cm 2)
                                     =         0.00565 mW/cm2                                               EIRP= Equivalent Isotropic Radiated Power(mW)
                                                                                                            R= Distance to the center of the radiation of the antenna(20cm)
                                ▪ Limits for General Population/Uncontrolled Exposure
                                                               Electric Field         Magnetic field
                                    Frequency range                                                          Power Density          Averageing time
                                                                 strength               strength                          2
                                         (MHz)                                                                 (mW/cm )                (minutes)
                                                                   (V/m)                 (A/m)
                                   0.3       ~      1.34                       614                  1.63                  *100                   30
                                                                                                                                2
                                  1.34       ~       30                       824/f              2.19 / f            *180 / f                    30
                                   30        ~       300                       27.5                0.073                      0.2                30
                                   300       ~      1,500                                                            f / 1500                    30

                                  1,500      ~     100,000                                                                    1.0                30

                                f = frequency in MHz * = Plane-wave equivalent power density

               Conclusion : The exposure condition of this device is compliant with FCC