RF Exposure Info

FCC ID:

RF Exposure Info

Download: PDF

             F2 Labs
             16740 Peters Road
             Middlefield, Ohio 44062
             United States of America
             www.f2labs.com                              CERTIFICATION TEST REPORT

Manufacturer:                  WaveFlex, Inc.
                               5480 Roesland Dr.
                               Galena, OH 43021 USA

Applicant:                     Same as Above

Product Name:                  Quantum Picocell Gateway Radio

Product Description:           Picocell gateway radio with USB connector                provides
                               simultaneous communication on 8 LoRa channels.

Model:                         MASM-100-1003-00: Quantum Picocell Gateway Radio

FCC ID:                        2ASYA-1001003

Testing Commenced:             July 17, 2018

Testing Ended:                 July 23, 2018

Test Results:                  In Compliance

                               The EUT complies with the EMC requirements when
                               manufactured identically as the unit tested in this report,
                               including any required modifications. Any changes to the
                               design or build of this unit subsequent to this testing may deem
                               it non-compliant.

Standards:
   • KDB447498




042216
Report Number: F2P19086C-10E               Page 1 of 8                   Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                            Client: WaveFlex, Inc.
                                                                         Model: MASM-100-1003-00




Evaluation Conducted by:
                                  Julius Chiller, EMC/Wireless Engineer



Report Reviewed by:
                                  Ken Littell, Director of EMC & Wireless Operations


         F2 Labs                         F2 Labs                           F2 Labs
         26501 Ridge Road                16740 Peters Road                 8583 Zionsville Road
         Damascus, MD 20872              Middlefield, OH 44062             Indianapolis, IN 46268
         Ph 301.253.4500                 Ph 440.632.5541                   Ph 317.610.0611




    This test report may be reproduced in full; partial reproduction only may be made with the written
    consent of F2 Labs. The results in this report apply only to the equipment tested.




042216
Report Number: F2P19086C-10E                   Page 2 of 8                       Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                       Client: WaveFlex, Inc.
                                                    Model: MASM-100-1003-00



                               TABLE OF CONTENTS


         Section                         Title                       Page


         1           ADMINISTRATIVE INFORMATION                         4
         2           SUMMARY OF TEST RESULTS/MODIFICATIONS              5
         3           ENGINEERING STATEMENT                              6
         4           EUT INFORMATION AND DATA                           7
         5           RF EXPOSURE FOR DEVICE >20cm FROM HUMAN            8




042216
Report Number: F2P19086C-10E        Page 3 of 8          Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                      Client: WaveFlex, Inc.
                                                                   Model: MASM-100-1003-00




1        ADMINISTRATIVE INFORMATION

1.1      Measurement Location:
         F2 Labs in Middlefield, Ohio. Site description and attenuation data are on file with the
         FCC's Sampling and Measurement Branch at the FCC Laboratory in Columbia, MD.

1.2      Measurement Procedure:
         All measurements were performed according to KDB558074.

1.4      Document History

                                                                                  Approved
          Document Number            Description             Issue Date
                                                                                     By
           F2P19086C-10E              First Issue          Aug. 16, 2019           K. Littell




042216
Report Number: F2P19086C-10E                Page 4 of 8                    Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                 Client: WaveFlex, Inc.
                                                              Model: MASM-100-1003-00



2        SUMMARY OF TEST RESULTS

          Test Name                             Standard(s)                      Results

    RF Exposure for Device
     >20cm from Human
                                                KDB447498                       Complies




                               Modifications Made to the Equipment

                                           None




042216
Report Number: F2P19086C-10E             Page 5 of 8                 Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                    Client: WaveFlex, Inc.
                                                                 Model: MASM-100-1003-00



3        ENGINEERING STATEMENT

         This report has been prepared on behalf of WaveFlex, Inc., to provide documentation
         for the testing described herein. This equipment has been tested and found to comply
         with KDB447498. The test results found in this test report relate only to the item(s)
         tested.




042216
Report Number: F2P19086C-10E               Page 6 of 8                  Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                     Client: WaveFlex, Inc.
                                                                  Model: MASM-100-1003-00



4        EUT INFORMATION AND DATA

4.1      Equipment Under Test:
         Product: Quantum Picocell Gateway Radio
         Model: MASM-100-1003-00
         Serial No.: None Specified
         FCC ID: 2ASYA-1001003

4.2      Trade Name:
         WaveFlex, Inc.

4.3      Power Supply:
         USB from Interface Power Supply

4.4      Applicable Rules:
         • KDB447498

4.5      Equipment Category:
         Radio Transmitter-DTS

4.6      Antenna:
         2.2dBi Whip

4.7      Accessories:
         Raspberry Interface

4.8      Test Item Condition:
         The equipment to be tested was received in good condition.




042216
Report Number: F2P19086C-10E               Page 7 of 8                 Issue Date: Aug. 16, 2019


         Order Number: F2P19086C                                 Client: WaveFlex, Inc.
                                                              Model: MASM-100-1003-00



5.       RF EXPOSURE FOR DEVICE >20cm FROM HUMAN

5.1      Requirements:

         Limit:                     1mW/cm2

         Formula used for result:   E.I.R.P.
                                    4 π R2

         Results:                   E.I.R.P. = 1000mW

                                    1000mW at the 923.3 MHz Low Channel
                                    which is the highest.

                                    1000mW          =   1000mW     = 0.199mW/cm2
                                      4 π R2             5026.55




042216
Report Number: F2P19086C-10E          Page 8 of 8                   Issue Date: Aug. 16, 2019



Document Created: 2019-08-23 19:40:34
Document Modified: 2019-08-23 19:40:34

© 2019 FCC.report