SAR Dipole Performance Measurement Report

FCC ID: 2ASXEMODEL1

RF Exposure Info

Download: PDF
FCCID_4274503

 <Justification of the extended calibration>
 Referring to KDB 865664 D01, if dipoles are verified in return loss<-20dB, (within 20% of
 prior calibration),and in impedance (within 5 ohm of prior calibration), the annual calibration
 is not necessary and the calibration interval can be extended.


                                         Body 835 MHz

      Date of
                     Return Loss (dB)       Delta (%)          Impedance          Delta(ohm)
   Measurement

    2017.08.15            -23.87                -                 49.0                 -

    2018.08.15            -22.21              -6.95              52.59                3.59


The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of
prior calibration. Therefore the verification result should support extended calibration.

<Dipole Verification Data>

Body 835MHz


                                        Body 1900 MHz

      Date of
                     Return Loss (dB)      Delta (%)          Impedance          Delta(ohm)
   Measurement

    2017.08.15            -20.22               -                48.8                 -

    2018.08.16            -23.26             15.03              47.11              -1.79
The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of
prior calibration. Therefore the verification result should support extended calibration.

<Dipole Verification Data>

Body 1900 MHz


                                        Body 2450 MHz

      Date of
                     Return Loss (dB)      Delta (%)          Impedance          Delta(ohm)
   Measurement

    2017.08.15            -32.75               -                48.8                 -

    2018.08.16            -31.06             -5.16              45.61              -3.19
The return loss is <-20dB, within 20% of prior calibration; the impedance is within 5 ohm of
prior calibration. Therefore the verification result should support extended calibration.

<Dipole Verification Data>

Body 2450 MHz