15B report

FCC ID: 2ASWV-GS63E-W1

Test Report

Download: PDF
FCCID_4388474

                          Shenzhen Zhongjian Nanfang Testing Co., Ltd.
                                                                                                  Report No: CCISE190405102

1        Cover Page

                                      FCC REPORT
Applicant:                                 Shenzhen Lingdu Auto Electronics Co., Ltd

Address of Applicant:                      1801-1808 Haiyun Building, No. 468 Minzhi Avenue, Longhua,
                                           Shenzhen, Guangdong, China
Equipment Under Test (EUT)

    Product Name:                          GS63E

    Model No.:                             GS63E, GS63T, GS63S

FCC ID:                                    2ASWV-GS63E-W1

Applicable standards:                      FCC CFR Title 47 Part 15 Subpart B

Date of sample receipt:                    11 Apr., 2019

Date of Test:                              11 Apr., to 31 Jul., 2019

Date of report issued:                     01 Aug., 2019

Test Result:                               PASS *
  * In the configuration tested, the EUT complied with the standards specified above.




 Authorized Signature:




       Bruce Zhang
    Laboratory Manager
This report details the results of the testing carried out on one sample. The results contained in this test report do not relate to other
samples of the same product and does not permit the use of the CCIS product certification mark. The manufacturer should ensure that all
products in series production are in conformity with the product sample detailed in this report.

This report may only be reproduced and distributed in full. If the product in this report is used in any configuration other than that detailed in
the report, the manufacturer must ensure the new system complies with all relevant standards.

This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
Unless otherwise stated the results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 90 days
only.


                                                                                 Report No: CCISE190405102

2      Version
      Version No.                            Date                                  Description
             00                        01 Aug., 2019                                 Original




    Tested by:                                                           Date:          01 Aug., 2019

                                       Test Engineer

    Reviewed by:                                                         Date:          01 Aug., 2019

                                    Project Engineer




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                          Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                         Page 2 of 29


                                                                                                                            Report No: CCISE190405102

3         Contents
                                                                                                                                                                                 Page
1     COVER PAGE ....................................................................................................................................................... 1
2     VERSION ............................................................................................................................................................... 2
3     CONTENTS ........................................................................................................................................................... 3
4     TEST SUMMARY .................................................................................................................................................. 4
5     GENERAL INFORMATION .................................................................................................................................. 5
    5.1    CLIENT INFORMATION ...................................................................................................................................................... 5
    5.2    GENERAL DESCRIPTION OF E.U.T. ...................................................................................................................................... 5
    5.3    TEST MODE.................................................................................................................................................................... 5
    5.4    MEASUREMENT UNCERTAINTY ........................................................................................................................................... 5
    5.5    DESCRIPTION OF SUPPORT UNITS ....................................................................................................................................... 6
    5.6    RELATED SUBMITTAL(S) / GRANT (S) ................................................................................................................................... 6
    5.7    DESCRIPTION OF CABLE USED ............................................................................................................................................ 6
    5.8    LABORATORY FACILITY ...................................................................................................................................................... 6
    5.9    LABORATORY LOCATION ................................................................................................................................................... 6
    5.10      TEST INSTRUMENTS LIST ............................................................................................................................................... 7
6     TEST RESULTS AND MEASUREMENT DATA ................................................................................................ 8
    6.1    CONDUCTED EMISSION ..................................................................................................................................................... 8
    6.2    RADIATED EMISSION ...................................................................................................................................................... 11
7     TEST SETUP PHOTO ........................................................................................................................................ 25
8     EUT CONSTRUCTIONAL DETAILS ................................................................................................................ 29




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                                                               Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                                                                        Page 3 of 29


                                                                              Report No: CCISE190405102

4      Test Summary
                 Test Item                                Section in CFR 47                 Result
           Conducted Emission                                 Part 15.107                    Pass
            Radiated Emission                                 Part 15.109                    Pass
All measurement data were performed in accordance with ANSI C63.4:2014 of test method.
 Remark:
 1. Pass: The EUT complies with the essential requirements in the standard.
 2. N/A: The EUT not applicable of the test item.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                       Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                      Page 4 of 29


                                                                                Report No: CCISE190405102

5      General Information
5.1 Client Information
        Applicant:                              Shenzhen Lingdu Auto Electronics Co., Ltd
        Address:                                1801-1808 Haiyun Building, No. 468 Minzhi Avenue, Longhua,
                                                Shenzhen, Guangdong, China
        Manufacturer:                           Shenzhen Lingdu Auto Electronics Co., Ltd
        Address:                                1801-1808 Haiyun Building, No. 468 Minzhi Avenue, Longhua,
                                                Shenzhen, Guangdong, China
        Factory:                                Dongguan KAKA Electronic Technology Co., Ltd
        Address:                                No.395, Huanshi East Road, Shitanpu,TangxiaTown, Dongguan,
                                                Guangdong, China

5.2 General Description of E.U.T.
        Product Name:                           GS63E
        Model No.:                              GS63E, GS63T, GS63S
        Power supply:                           Rechargeable Li-ion Battery DC3.7V-250mAh
                                                Model: HC-801
        DC adapter :                            Input: DC 12-24V, 0.15A
                                                Output: DC 5.0V, 2.5A
        Test Sample Condition:                  The test samples were provided in good working order with no
                                                visible defects.
        Remarks:                                Model No.: GS63E, GS63T, GS63S were identical inside, the
                                                electrical circuit design, layout, components used and internal
                                                wiring, with Onlythe shell is a little different.

5.3 Test Mode
 Conducted emission:
           PC mode                 Keep the EUT in Downloading mode
 Radiated emission:
 Charging+Recording mode           Keep the EUT in Charging+Recording(HDMI Output ) mode
    Charging+Playing mode          Keep the EUT in Charging+Playing( HDMI Output ) mode
          GPS mode              Keep the EUT in GPS receiver mode
 The sample was placed 0.8m above the ground plane of 3m chamber. Measurements in both horizontal and
 vertical polarities were performed. During the test, each emission was maximized by: having the EUT
 continuously working, investigated all operating modes, rotated about all 3 axis (X, Y & Z) and considered
 typical configuration to obtain worst position, manipulating interconnecting cables, rotating the turntable,
 varying antenna height from 1m to 4m in both horizontal and vertical polarizations. The emissions worst-case
 are shown in Test Results of the following pages.

5.4 Measurement Uncertainty
                    Parameters                                              Expanded Uncertainty
        Conducted Emission (9kHz ~ 30MHz)                                      ±1.60 dB (k=2)
         Radiated Emission (9kHz ~ 30MHz)                                      ±3.12 dB (k=2)
       Radiated Emission (30MHz ~ 1000MHz)                                     ±4.54 dB (k=2)
        Radiated Emission (1GHz ~ 18GHz)                                       ±5.84 dB (k=2)
        Radiated Emission (18GHz ~ 40GHz)                                      ±3.36 dB (k=2)

Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                             Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 5 of 29


CCIS                                                                             Report No: CCISE190405102

5.5 Description of Support Units
      Manufacturer                Description                 Model           Serial Number          FCC ID/DoC

        Skyworth                 Color LCD TV                24E12HR             K026709                 N/A
        GS Japan               Lead—acid battery          55D26R—MFZ           8362810610                N/A
            DELL                       PC                 OPTIPLEX745               N/A                  DoC
            DELL                   MONITOR                   E178FPC                N/A                  DoC
            DELL                  KEYBOARD                   SK—8115                N/A                  DoC
            DELL                    MOUSE                    MOCSUO                 N/A                  DoC
        LENOVO                       Laptop                   SL510              2B47A65                 DoC

5.6 Related Submittal(s) / Grant (s)
       This is an original grant, no related submittals and grants.

5.7 Description of Cable Used
            Cable Type                    Description              Length            From                 To
      Detached USB Cable                    Shielding               1.0m              EUT                 PC
   Non—separating USB Cable                 Unshielded              3.5m              EUT             Car charger

5.8 Laboratory Facility
        The test facility is recognized, certified, or accredited by the following organizations:
        ®@ FCC — Designation No.: CN1211
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been accredited as a testing laboratory by
       FCC(Federal Communications Commission). The test firm Registration No. is 727551.
        @ ISED — CAB identifier.: CNOO21
       The 3m Semi—anechoic chamber of Shenzhen Zhongjian Nanfang Testing Co., Ltd. has been
       Registered by Certification and Engineering Bureau of Industry Canada for radio equipment testing with
        Registration No.: 10106A—1.
        @ CNAS — Registration No.: CNAS L6048
       Shenzhen Zhongjian Nanfang Testing Co., Ltd. is accredited to ISO/IEC 17025:2005 General
       Requirements for the Competence of Testing and Calibration laboratories for the competence of
       testing. The Registration No. is CNAS L6048.
        ®    A2LA — Registration No.: 4346.01
        This laboratory is accredited in accordance with the recognized International Standard ISO/IEC
        17025:2005 General requirements for the competence of testing and calibration laboratories. The test
        scope can be found as below link: https://portal.a2la.org/scopepdf/4346—0 1.pdf

5.9 Laboratory Location
        Shenzhen Zhongjian Nanfang Testing Co., Ltd.
        Address: No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
        Bac‘an District, Shenzhen, Guangdong, China
        Tel: +86—755—23118282, Fax: +86—755—23116366
       Email: info@ccis—cb.com, Website: http//www.ccis—cb.com




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                              Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                             Page 6 of 29


                                                                                  Report No: CCISE190405102

5.10 Test Instruments list
 Radiated Emission:
                                                                                           Cal. Date        Cal. Due date
    Test Equipment            Manufacturer             Model No.          Serial No.
                                                                                          (mm-dd-yy)         (mm-dd-yy)
        3m SAC                  SAEMC                  9m*6m*6m               966         07-22-2017         07-21-2020
     Loop Antenna            SCHWARZBECK              FMZB1519B             00044         03-18-2019         03-17-2020
   BiConiLog Antenna         SCHWARZBECK               VULB9163               497         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D               916         03-18-2019         03-17-2020
     Horn Antenna            SCHWARZBECK              BBHA9120D              1805         06-22-2017         06-21-2020
     Horn Antenna            SCHWARZBECK              BBHA 9170          BBHA9170582      11-21-2018         11-20-2019
   EMI Test Software             AUDIX                    E3                           Version: 6.110919b
     Pre-amplifier                 HP                   8447D            2944A09358       03-18-2019         03-17-2020
     Pre-amplifier                 CD                  PAP-1G18             11804         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP30              101454         03-18-2019         03-17-2020
   Spectrum analyzer         Rohde & Schwarz            FSP40              100363         11-21-2018         11-20-2019
   EMI Test Receiver         Rohde & Schwarz           ESRP7                101070        03-18-2019         03-17-2020
        Cable                    ZDECL              Z108-NJ-NJ-81          1608458        03-18-2019         03-17-2020
        Cable                 MICRO-COAX              MFR64639             K10742-5       03-18-2019         03-17-2020
        Cable                   SUHNER              SUCOFLEX100           58193/4PE       03-18-2019         03-17-2020


 Conducted Emission:
                                                                                         Cal. Date          Cal. Due date
   Test Equipment             Manufacturer            Model No.           Serial No.
                                                                                        (mm-dd-yy)           (mm-dd-yy)
  EMI Test Receiver         Rohde & Schwarz             ESCI               101189       03-18-2019           03-17-2020
    Pulse Limiter           SCHWARZBECK              OSRAM 2306             9731        03-18-2019           03-17-2020
        LISN                    CHASE                 MN2050D               1447        03-18-2019           03-17-2020
        LISN                Rohde & Schwarz           ESH3-Z5            8438621/010    07-21-2018           07-20-2021
       Cable                      HP                   10503A                N/A        03-18-2019           03-17-2020
  EMI Test Software             AUDIX                    E3                          Version: 6.110919b




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                  Page 7 of 29


                                                                              Report No: CCISE190405102

6      Test results and Measurement Data
6.1 Conducted Emission
       Test Requirement:                FCC Part 15 B Section 15.107
       Test Frequency Range:            150kHz to 30MHz
       Class / Severity:                Class B                  Class B
       Receiver setup:                  RBW=9kHz, VBW=30kHz
       Limit:                                                                        Limit (dBµV)
                                          Frequency range (MHz)
                                                                          Quasi-peak                Average
                                                 0.15-0.5                   66 to 56*               56 to 46*
                                                   0.5-5                       56                      46
                                                  0.5-30                       60                      50
                                        * Decreases with the logarithm of the frequency.
       Test setup:




       Test procedure                   1. The E.U.T and simulators are connected to the main power through a
                                           line impedance stabilization network(L.I.S.N.). The provide a
                                           50ohm/50uH coupling impedance for the measuring equipment.
                                        2. The peripheral devices are also connected to the main power through a
                                           LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                           termination. (Please refers to the block diagram of the test setup and
                                           photographs).
                                        3. Both sides of A.C. line are checked for maximum conducted
                                           interference. In order to find the maximum emission, the relative
                                           positions of equipment and all of the interface cables must be changed
                                           according to ANSI C63.4: 2014 on conducted measurement.
       Test Instruments:                Refer to section 5.9 for details
       Test mode:                       Refer to section 5.3 for details
       Test results:                    PASS




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                           Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 8 of 29


m                                                                                     Report No: CCISE190405102

Model No: GS63E, GS63T, GS63S were tested, of which GS63E was the worst, Will only put the worst
case in the report.

Measurement data:
 Product name:                    GS6SE                          Product model:           GS6SE

 Test by:                         Carey                          Test mode:               PC mode

 Test frequency:                  150 kHz ~ 30 MHz               Phase:                   Line

 Test voltage:                    AC 120 V/60 Hz                 Environment:             Temp: 22.5°C         Huni: 55%

                so Level (dBuV)


                70

                ao\\                                                                             ECC PaRT15 8 op
                50\\\;                                                                          ECC PART15B AV


                40
                                                                                                         2
                30

                20

                10

                 0

            Trace: 133
                                                          Frequency (MHz)

                                     Read   LISN        Cable                 Limit     Over
                          Freq      Level Factor          Loss    Level        Line    Limit Remark

                           MHz       dBu¥          dB      dB      dBu¥        dBu¥       dB

           1              0.582      4.46    —0.39      10.76     14.83     46.00     —31.17    Average
           2              .665      12.98    —0.38      10.77     23.31     56.00     —32.63    QFr
           5              1.698     13.31    —0.40      10.94     23.85     56.00     —32.15    QP
           4              1.707       8.70   —0.40      10.94     19.24     46.00     —26.76    Average
           5              3.417     14.94    —0.45§     10.91     25.40     56.00     —30.60    qP
           6              3.417     i1.41    —0.45      10.91     21.87     46.00     —24.13    Average
           T             10.233       8.87   —O.61      10.94     19.20     50.00     —30.80    Average
           8             11.933     14.78    —O.64      10.92     25.06     60.00     —34.94    QP
           9             16.928     19.92    —0.80      10.91     30.03     50.00     —19.97    Average
          10             18.039     21.98    —O.87      10.92     32.03     60.00     —27.97    QP
          11             18.039     20.38    —O0.87     10.92     30.43     50.00     —19.57    Average
          12             19.122     22.13    —0.92      10.92     32.13     60.00     —27.57    QP


 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2. Quast—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongjian Nantfang Testing Co., Ltd.                                                  Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 9 of 29


w                                                                                      Report No: CCISE190405102


 Product name:                    GS6sE                          Product model:            GSesE

Test by:                          Carey                          Test mode:                PC mode

Test frequency:                   150 kHz ~ 30 MHz               Phase:                    Neutral

Test voltage:                     AC 120 V/60 Hz                 Environment:              Temp: 22.5°C        Huni: 55%

               so Level (dBuV)


               70

               eol                                                                                ECC PART15 B OP

               sol                                                                                ECC PART15B AV


               40
               30

               20

               10

                0
                                                           Frequency (MHz)
           Trace: 135



                                    Read    LISN        Cable                 Limit      Over
                         Freq      Level Factor           Loss   Level         Line     Limit Remark

                          MHz        dBu¥          dB      dB      dBu¥        dBu¥        dB

           1            0.471        5.80    —0.65      10.75     15.90       46.49 —30.59 Average
           2            0.683       13.85    —O.64      10.77     23.98       56.00 —32.02 QP
           3            2.636       15.24    —O.67      10.93     25.50       56.00 —30.50 QP
           4            2.7T1T9       T.59   —0.67      10.93     17.85       46.00 —28.15 Average
           5         10,.233        15.95    —0.79      10.94     26.10       60.00 —33.90 QP
           6         10.233         12.69    —0.79      10.94     22.84       50.00 —27.16 Average
           7         11.933         17.44    —0.80      10.92     27.56       60.00 —32.44 QP
         8           14.828         17.44    —O.81      10.90     27.53       50.00    —22.47    Average
         9           15.970         21.05    —0.94      10.91     31.02       50.00    —18.98    Average
        10           17.018         25.53    —1.07      10.91     35.37       §$0.00   —24.63    QP
        $1           17.018         24.09    —1.07      10.91     33.93       50.00    —16.07    Average
        12           18.039         25.69    —1.19      10.92     35.42       60.00    —24.58    QP

 Notes:
 1. An initial pre—scan was performed on the line and neutral lines with peak detector.
 2. Quasi—Peak and Average measurement were performed at the frequencies with maximized peak emission.
 3. _Final Level =Receiver Read level + LISN Factor + Cable Loss.




Shenzhen Zhongfian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 10 of 29


                                                                         Report No: CCISE190405102

6.2 Radiated Emission
        Test Requirement:             FCC Part 15 B Section 15.109
        Test Frequency Range:         30MHz to 25000MHz
        Test site:                    Measurement Distance: 3m (Semi-Anechoic Chamber)
        Receiver setup:                 Frequency       Detector        RBW      VBW           Remark
                                       30MHz-1GHz      Quasi-peak      120kHz   300kHz    Quasi-peak Value
                                                         Peak           1MHz     3MHz       Peak Value
                                       Above 1GHz
                                                         RMS            1MHz     3MHz      Average Value
        Limit:                               Frequency           Limit (dBuV/m @3m)          Remark
                                           30MHz-88MHz                    40.0           Quasi-peak Value
                                          88MHz-216MHz                    43.5           Quasi-peak Value
                                          216MHz-960MHz                   46.0           Quasi-peak Value
                                           960MHz-1GHz                    54.0           Quasi-peak Value
                                                                          54.0            Average Value
                                            Above 1GHz
                                                                          74.0             Peak Value
        Test setup:                   Below 1GHz




                                      Above 1GHz




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                     Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                    Page 11 of 29


                                                                               Report No: CCISE190405102


        Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above
                                           the ground at a 3 meter semi-anechoic camber. The table was rotated
                                           360 degrees to determine the position of the highest radiation.
                                        2. The EUT was set 3 meters away from the interference-receiving
                                           antenna, which was mounted on the top of a variable-height antenna
                                           tower.
                                        3. The antenna height is varied from one meter to four meters above the
                                           ground to determine the maximum value of the field strength. Both
                                           horizontal and vertical polarizations of the antenna are set to make the
                                           measurement.
                                        4. For each suspected emission, the EUT was arranged to its worst case
                                           and then the antenna was tuned to heights from 1 meter to 4 meters
                                           and the rotatable table was turned from 0 degrees to 360 degrees to
                                           find the maximum reading.
                                        5. The test-receiver system was set to Peak Detect Function and
                                           Specified Bandwidth with Maximum Hold Mode.
                                        6. If the emission level of the EUT in peak mode was 10dB lower than the
                                           limit specified, then testing could be stopped and the peak values of
                                           the EUT would be reported. Otherwise the emissions that did not have
                                           10dB margin would be re-tested one by one using peak, quasi-peak or
                                           average method as specified and then reported in a data sheet.
        Test Instruments:               Refer to section 5.9 for details
        Test mode:                      Refer to section 5.3 for details
        Test results:                   Passed
        Remark:                         All of the observed value above 6GHz ware the niose floor , which were
                                        no recorded ,only worse case is reported




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                            Project No.: CCISE1904051
No. B-C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bao’an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                            Page 12 of 29


c c I s                                                                                   Report No: CCISE190405102

Measurement Data:
Model No: GS63E, GS63T, GS63S were tested, of which GS63E was the worst, Will only put the worst
case in the report.
Below 1GHz:
DC 12V:

 Product Name:                    GSesE                                  Product model:         GSesE

Test By:                          Carey                                  Test mode:             Charging&Recording mode

Test Frequency:                   30 MHz ~1 GHz                          Polarization:          Vertical

Test Voltage:                     DC 12V                                 Environment:           Temp: 24°C      Huni: 57%


              80Level (dBuVim)



              70

              60
                                                                                                FCC PART1S CLAS$ B




                   30             50                100               200                       500             1000
                                                             Frequency (MHz)
                                        ReadAntenna     Cable Preamp                  Limit    Over
                           Freq        Level Factor      Loss Factor        Level      Line   Linit Remark

                            NBz         dbu¥    dB/m        dB       dB dBu¥/m dBu¥/m             dB
          1             190.40§        48.11   10. 30     2.80   28.90      32.31     43.50 —11.19 QP
          2             297.224        41.23   13.56      2.93   28.46      35.26     46.00 —10.74 QP
          3             459.114        §2.95   16.84      3.27   28.89      44.17     46.00 —1.83 QP
          4             487.315        45.20   17.79      3.51   28.93      37.57     46.00 —8.43 QP
          5             595.133        48.02   19. 39     3.94   28.95      42.40     46.00 —3.60 QP
          6             744.866        43.34   20.59      4.34   28.50      39.77     46.00 —6.23 QP

 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                     Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                    Page 13 of 29


c c I s                                                                                     Report No: CCISE190405102



 Product Name:                     GSesE                                  Product model:            GSesE

 Test By:                          Carey                              Test mode:                    Charging&Recording mode

 Test Frequency:                   30 MHz ~ 1 GHz                         Polarization:             Horizontal

 Test Voltage:                     DC 12V                                 Environment:              Temp: 24°C       Huni: 57%


              8OLevel (dBuVim)



              70

              60
                                                                                                   FCC PART15 CLASS$ B
              50

              40

              30

              20

              10


                   30          50                   100              200                           500              1000
                                                              Frequency (MHz)
                                      Read&ntenna         Cable Preamp                    Limit     Over
                           Freq      Level Factor           Loss Factor Level               Line   Limit Remark

                            THz       dBu¥y    dB/m          dB      dB dBu¥/m dBu¥/m                    dB
          1             186.441      50.09    10.18        2.77   28.93      34.11        43.50 —9.39 QP
          2             230.907      49.82    11.95        2.83   28.64      35.96        46.00 —10.04 QP
          3             297.224      54.65    13.56        2.93   28.46      42.68        46.00 —3.32 QP
          4             404.667      48.01    15.43        3.09   28.79      37.74        46.00 —8.26 P
          5             459.114      45.79    16.84        3.27   28.89      37.01        46.00 —8.99 qP
          6             595. 133     44.07    19.39        3.94   28.95      38.45        46.00 —7.55 qP

 Remark:
 1. Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                         Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                         Page 14 of 29


CCIS                                                                                   Report No: CCISE190405102

DC 24V:
 Product Name:                 GSesE                                  Product model:               GSesE

Test By:                       Carey                                  Test mode:                   Charging&Recording mode

Test Frequency:                30 MHz ~1 GHz                          Polarization:                Vertical

Test Voltage:                  DC 24V                                 Environment:                 Temp: 24°C      Huni: 57%


          80Level (dBuVim)


          70

          60
                                                                                                  FCC PART15 CLAS$ B
          50                                                                                  5
                                                                                          i              6
          40                                                                             4
                       1                   s                              3
          30                               +                                  I

          20

          10


               30          50                  100                200                             500             1000
                                                        Frequency (MHz)
                                 Read&ntenna         Cable Preamp                  Limit           Over
                       Freq     Level Factor           Loss Factor        Level     Line          Linit Remark

                       ~NHz       dBu¥y    db/m         db _       dB dBu¥/n dBu¥/m                     db
         1           40.988     48.47     12.38       1.22    29.89       32.18    40.00 —7.52 qP
         2           85.598     48.41      8. 89      1.87    29.60       29.57    40.00 —10.43 QP
         3          243.377     45.48     12.42       2.82    28.58       32.14    46.00 —13.86 QP
         4          404.667     48.175    15.43       3.09    28.79       38.48    46.00 —T.52 QP
         5          459.114     53.41     16.84       3.2T    28.89       44.63    46.00 —1.37 QP
         6          595. 133    46.07     19.39       3.94    28.95       40.45    46.00 —5.55 P

 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                       Page 15 of 29


c c I s                                                                                    Report No: CCISE190405102



 Product Name:                     GSesE                                  Product model:          GSesE

 Test By:                          Carey                                  Test mode:              Charging&Recording mode

 Test Frequency:                   30 MHz ~ 1 GHz                         Polarization:           Horizontal

 Test Voltage:                     DC 24V                                 Environment:            Temp: 24°C     Huni: 57%


              80Levs,-l (dBuVim)


              70

              60
                                                                                                  FCC PART15 CLAS$ B
              50




                   30              50                100                200                       500             1000
                                                              Frequency (MHz)
                                         Readintenna     Cable Preamp                  Limit     Over
                           Freq         Level Factor       Loss Factor      Level        Line   Linit Remark

                            NHz          dBu¥    dB/n        dB      dB dBu¥/m dBuT¥/m             dB
          1             170. 793        51.20    9. 66     2.66   29.04     34.48      43.50 —9.02 QP
          2             243.377         50.75   12.42      2.82   28.58     37.41      46.00 —8.59 QP
          3             297.224         47.78   13.56      2.93   28.46     35.81      46.00 —10.19 QP
          4             404.667         50.99   15.43      3.09   28.79     40.72      46.00 —5.28 QP
          5             459.114         53.00   16.84      3.27   28.89     44.22      46.00 —1.78 QP
          6             §95.133         44.78   19.39      3.94   28.95     39.16      46.00 —6.84 QP

 Remark:
 1.  Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                      Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                      Page 16 of 29


c c I s                                                                                Report No: CCISE190405102

For AC:

 Product Name:              GSesE                                     Product model:              GSesE

Test By:                    Carey                                     Test mode:                  PC mode

Test Frequency:             30 MHz ~1 GHz                             Polarization:               Vertical

Test Voltage:               AC 120/60Hz                               Environment:                Temp: 24°C       Huni: 57%


            solevel (dBuV/im)



            70

            60
                                                                                                 FCC PART15 CLASS$ B
            50                                                                              :z

            40

            30

            20

            10


               G3(]         50                 100                 200                           500              1000
                                                         Frequency (MHz)
                                  Readintenna        Cable Preamp                  Limit     Over
                         Freq    Level Factor          Loss Factor       Level      Line    Limit Remark

                          MHz     dBu¥     dB/m         dB        dB dBu¥/m dBu¥/m                     dB
           1          147.921    49.93     9.01       2.50    29.23      32.21     43.50 —11.29 QP
           2          239.987    51.86    12.30       2.82    28.59      38.39     46.00 —7.61 QP
           3          404.667    51.13    15.43       3.09    28.79      40.86     46.00 —5.14 QP
           4          459.114    53.13    16.84       3.27    28.89      44.35     46.00 —1.65 QP
           5          709.182    48.20    20.44       4.21    28.63      44.22     46.00 —1.78 QP
           6          721.726    48.37    20.49       4.26    28.58      44.54     46.00 —1.46 QP


 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                       Page 17 of 29


CCIS                                                                                    Report No: CCISE190405102


 Product Name:                  GSesE                                  Product model:           GSesE

 Test By:                       Carey                                  Test mode:               PC mode

 Test Frequency:                30 MHz ~ 1 GHz                         Polarization:            Horizontal

 Test Voltage:                  AC 120/60Hz                            Environment:             Temp: 24°C     Huni: 57%


            sOLe\'eI (dBuVim)


            70

            60
                                                                                              FCC PART15 CLASS$ B
            50

            40

            30

            20

            10


                030         50                   100                 200                      500              1000
                                                           Frequency (MHz)
                                   Readintenna         Cable Preamp                 Limit     Over
                         Freq     Level Factor           Loss Factor     Level        Line   Limit Remark

                          WHz      dBu¥y      dB/m        dB       dB dBu¥/m dBu¥/m              dB ~         CCC
            1         239.987     §3.20    12.30        2.82   28.59     39.73      46.00    —6.27   QP
            2         254.728     5§0.73   12.78        2.82   28.53     37.80      46.00    —8.20   qP
            3         351.708     48.81    14.62        3.10   28.57     37.96      46.00    —8.04   QP
            4         459.114     §2.99    16.84        3.27   28.89     44.21      46.00    —1.79   QP
            5         645.120     43.57    19.69        3.87   28.79     38.34      46.00    —7.66   QP
            6         T21.726     45.78    20.49        4.26   28.58     41.95      46.00    —4.05   QP

 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                    Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                   Page 18 of 29


M                                                                                              Report No: CCISE190405102

Above 1GHz:
For DC 12V;:
 Product Name:                 GS6SE                                       Product model:           GS6SE

 Test By:                      Carey                                       Test mode:               Charging&Recording mode

 Test Frequency:               1 GHz ~6 GHz                                Polarization:            Vertical

 Test Voltage:                 DC A12V                                     Environment:             Temp: 24°C           Huni: 57%


              sOlevel (dBu\Vim)
                                                                                                     FCC PART 15 (PK)
              70

              60
                                                                                                     FCC PART 15 (AV)
              50                                                                           1              3        4
              40

              30

              20

              10


               G1000    1200           1500             2000                                              5000     6000
                                                               Frequency (MHz)

                                   ReadAntenna          Cable Preamp                 Limit        Over
                       Freq       Level Factor            Loss Factor       Level      Line      Limit Remark

                        MNHz       dBu¥y       dB/m —      db _dB dBu¥/m dBu¥/m                     db
          1        3612.141       48.17       29.21      5.90     41.55     43.93    74.00      —30.07   Peak
          2         3612.141      37.77       29.21      5.90     41.55     33.53    54.00      —20.47   Average
          3         4864.797      49.57       31.69      6.84     41.83     48.74    74.00      —25.26   Peak
          4         4864.797      38.14       31.69      6.84     41.83     37.31    54.00      —16.69   Average
          5         5864.002      49.290      33.06      7.90     42.03     50.98    74.00      —23.02   Peak
          6         5864.002      38.87       33.06      7.90     42.03     40.56    54.00      —13.44   Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongfian Nantfang Testing Co., Ltd.                                                       Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                             Page 19 of 29


CCIS                                                                                        Report No: CCISE190405102


 Product Name:                    GSesE                                    Product model:          GSesE

Test By:                          Carey                                    Test mode:              Charging&Recording mode

Test Frequency:                   1 GHz ~6 GHz                             Polarization:           Horizontal

Test Voltage:                     DC 12V                                   Environment:            Temp: 24°C         Huni: 57%


              80Le\'eI (dBuVim)

                                                                                                       FCC PART 15 (PK)
              70

              60
                                                                                                       FCC PART 15(A\{)
              50                                                                                   3        3        4
              40                                                                                           "

              30

              20


              10


                   1000   1200            1500           2000                                               5000     6000
                                                                Frequency (MHz)
                                    Readintenna          Cable Preamp                 Limit     Over
                          Freq     Level Factor            Loss Factor       Level      Line   Limit Remark

                           NHz       dbu¥y        db/m      db _       dB dBu¥/m dBu¥/m            db
          1         4253.563       48.290        30.67    6.48     41.85     45.87    74.00    —28.13   Peak
          2          4253.563      39.17         30.67    6.48     41.85     36.75    54.00    —17.25   Average
          3          4864.7T97     48.01         31.69    6.84     41.83     47.18    74.00    —26.82   Peak
          4          4864.797      39.17         31.69    6.84     41.83     38.34    54.00    —15.66   Average
          5          §829.869      48.34         33.00    7.90     42.03     49.96    74.00    —24.04   Peak
          6         5§829.869      39.64         33.00    7.90     42.03     41.26    54.00    —12.74   Average


 Remark:
 1.   Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lowerthan the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 20 of 29


CCIS                                                                                      Report No: CCISE190405102

For DC 24V:
 Product Name:                  GSesE                                   Product model:                GSesE

 Test By:                       Carey                                 Test mode:                      Charging&Recording mode

 Test Frequency:                1 GHz ~ 6 GHz                           Polarization:                 Vertical

 Test Voltage:                  DC 24V                                  Environment:                  Temp: 24°C          Huni: 57%


            so Level (dBuVim)

                                                                                                       FCC PART 15 (PK)
            70

            60
                                                                                                       FCC PART 15 (AV)
            50                                                                                               3       $
                                                                                                1
            40                                                                                                       &

            30

            20

            10


                 1000   1200            1500           2000                                                  5000    6000
                                                            Frequency (MHz)
                                   Read&ntenna          Cable Preamp                    Limit         Over
                        Freq      Level Factor            Loss Factor Level              Line        Limit Remark

                 ______WHz dBu¥y dB/m — db — dB dBu¥/m dBu¥/m —dB —
          1        3950.383       46.76        30.12     6.10   41.80     43.38         74.00       —30.62   Peak
          2        3950.383       36.82        30.12     6.10   41.80     33.44         54.00       —20.56   Average
          3         4808.328      47.69        31.02     6.80   41.81     46.14         74.00       —27.86   Peak
          4         4808.328      39.27        31.02     6.80   41.81     37.72         54.00       —16.28   Average
          5        5762.199       47.26        32.65     T.T9   41.98     48.45         74.00       —25.55   Peak
          6        5762.199       37.28        32.65     T.79   41.98     38.47         54.00       —15.53   Average


 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                          Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                              Page 21 of 29


c c I s                                                                                    Report No: CCISE190405102



 Product Name:                   GSesE                                    Product model:            GSesE

Test By:                         Carey                                    Test mode:                Charging&Recording mode

Test Frequency:                  1 GHz ~6 GHz                             Polarization:             Horizontal

Test Voltage:                    DC 24V                                   Environment:              Temp: 24°C       Huni: 57%


             80Level (dBu\Vim)
                                                                                                      FCC PART 15 (PK)
             T0

             60
                                                                                                      FCC PART 15 (AV)
             50                                                                                 4
                                                                                                         z3          &

             40                                                                                                      (

             30

             20

             10


              G1000    1200              1500           2000                                                  5000   6000
                                                               Frequency (MHz)
                                   Read&ntenna          Cable Preamp                   Limit      Over
                       Freq       Level Factor            Loss Factor       Level        Line    Limit Remark

                  _____NHz dBu¥ dB/m —db _                             dB dBu¥/m dBuT¥/m            dB               C
         1        3942.7T04       46.60         30.12    6.10     41.80     43.22      74.00    —30.78   Peak
         2         3942.704       36.84         30.12    6.10     41.80     33.46      54.00    —20.54   Average
         3        4697.350        48.02         30.81    6.85     41.99     46.10      74.00    —27.90   Peak
         4         4697.350       38.25         30.81    6.85§    41.99     36.33      54.00    —17.67   Average
         5         5841.225       47.24         32.67    7.90     42.03     48.53      74.00    —25.47   Peak
         6         5841.225       37.41         32.67    7.90     42.03     38.70      54.00    —15.30   Average


 Remark:
 1.  Final Level = Receiver Read level + Antenna Factor + Cable Loss— Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                        Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                          Page 22 of 29


CCIS                                                                                       Report No: CCISE190405102

For PC:
Above 1GHz:
 Product Name:                 GSese                                      Product model:           GSesE

 Test By:                      Carey                                      Test mode:               PC mode

 Test Frequency:               1 GHz ~ 6 GHz                              Polarization:            Vertical

 Test Voltage:                 AC 120/60Hz                                Environment:             Temp: 24°C       Huni: 57%


            BOLeveI (dBu\im)

                                                                                                    FCC PART 15 (PK)
            70

            50
                                                                                                    FCC PART 15 (AV)
            50

            40

            30

            20

            10


                 1000   1200           1500           2000                                                5000     6000
                                                             Frequency (MHz)
                                  ReadiAntenna        Cable Preamp                     Limit      Over
                        Freq     Level Factor           Loss Factor         Level        Line    Limit Remark

                         NBz      dbu¥y        dB/m          dB       dB dBu¥/m dBu¥/m              dB
          1        2893.635      43.90        28.40     5.24      41.58     35.96      74.00    —38.04   Peak
          2        2893.635      34.69        28.40     5.24      41.58     26.75      54.00    —27.25   Average
          3        4030.897      44.50        30.26     6.15      41.81     39.10      74.00    —34.90   Peak
          4         4030.897     35.04        30.26     6.15      41.81     29.64      54.00    —24.36   Average
          5        4813.252      46.44        31.61     6.81      41.82     43.04      74.00    —30.96   Peak
          6         4813.252     37.22        31.61     6.81      41.82     33.82      54.00    —20.18   Average


 Remark:
 1.  Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 23 of 29


CCIS                                                                                       Report No: CCISE190405102


 Product Name:                 GSesE                                      Product model:           GSesE

Test By:                       Carey                                      Test mode:               PC mode

Test Frequency:                1 GHz ~6 GHz                               Polarization:            Horizontal

Test Voltage:                  AC 120/60Hz                                Environment:             Temp: 24°C       Huni: 57%

           8olevel (dBu\Vim)
                                                                                                      FCC PART 15 (PK)
           70

           60
                                                                                                     FCC PART 15 (AV)
           50

           40                                                               7               3

           30

           20

           10


                1000   1200            1500           2000                                                  5000   6000
                                                             Frequency (MHz)

                                  ReadAntenna         Cable Preamp                     Limit      Over
                       Freq      Level Factor           Loss Factor         Level        Line    Limit Remark

                       ~NHz — dBbu¥            dB/m          dB      dB dBu¥/m dBu¥/m —             dB               ~
          1       2801.799       43.91        28.23    5.13       41.66     35.61      74.00    —38.39   Peak
          2        2801.799      34.53        28.23    5.13       41.66     26.23      54.00    —27.77   Average
          3        3758.839      44.41        29.59    6.04       41.74     38.30      74.00    —35.70   Peak
          4        3758.839      35.20        29.59    6.04       41.74     29.09      54.00    —24.91   Average
          5        4997.811      46.10        31.90    6.94       41.88     43.06      74.00    —30.94   Peak
          6        4997.811      36.64        31.90    6.94       41.88     33.60      54.00    —20.40   Average


 Remark:
 1.    Final Level = Receiver Read level + Antenna Factor + Cable Loss — Preamplifier Factor.
 2.   The emission levels of other frequencies are very lower than the limit and not show in test report.




Shenzhen Zhongjian Nanfang Testing Co., Ltd.                                                       Project No.: CCISE1904051
No. B—C, 1/F., Building 2, Laodong No.2 Industrial Park, Xixiang Road,
Bac‘an District, Shenzhen, Guangdong, China
Telephone: +86 (0) 755 2311 8282 Fax: +86 (0) 755 2311 6366                                                        Page 24 of 29



Document Created: 2019-08-07 11:58:43
Document Modified: 2019-08-07 11:58:43

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC