Test report

FCC ID: 2ASRT-SCN650

Test Report

Download: PDF
FCCID_4338548

                                                   TEST REPORT
Report Reference No. .................... :               CHTEW19050099                   Report verification:

Project No. ...................................... :      SHT1901065803EW

FCC ID ............................................. :    2ASRT-SCN650

Applicant’s name ........................... :            Screeneo Innovation SA

Address ............................................. :   Route de Lully 5C, 1131 Tolochenaz, Switzerland

Manufacturer......................................:       SHENZHEN HOLATEK CO. LTD.
                                                          1001,10F,Building B4,KeXing Science Park,Nanshan,
Address...............................................:
                                                          Shenzhen,China.
Test item description .................... :              Home Projector

Trade Mark ....................................... :      Philips

Model/Type reference ....................... :            Screeneo S6

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Mar 29, 2019

Date of testing…………………………:                                Mar 30, 2019- May 23, 2019

Date of issue…………………………...:                               May 24, 2019

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Silvia Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Aaron Fang
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.




                                                                    Page: 1 of 17


Report No : CHTEW19050099                                                Page 2 of 17                                                  Issued: 2019-05-24




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1. Client Information                                                                                                                                                   5
3.2. Product Description                                                                                                                                                  5
3.3. EUT operation mode                                                                                                                                                   5
3.4. Configuration of Tested System                                                                                                                                       错
误!未定义书签。
3.5. Support unit used in test configuration                                                                                                                              错
误!未定义书签。


4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1.    Address of the test laboratory                                                                                                                                    6
4.2.    Test Facility                                                                                                                                                     6
4.3.    Environmental conditions                                                                                                                                          7
4.4.    Statement of the measurement uncertainty                                                                                                                          7
4.5.    Equipments Used during the Test                                                                                                                                   8

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.1.    Conducted Emissions Test                                                                                                                                          9
5.2.    Radiated Emissions Test                                                                                                                                           12

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                         Page 3 of 17                  Issued: 2019-05-24



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-05-24                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                       Page 4 of 17                           Issued: 2019-05-24



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                    PASS          Tony Duan
          Radiated Emissions                          15.109(a)                    PASS         Michael Jie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                      Page 5 of 17                       Issued: 2019-05-24



3. SUMMARY
3.1. Client Information
Applicant:                    Screeneo Innovation SA

Address:                      Route de Lully 5C, 1131 Tolochenaz, Switzerland

Manufacturer:                 SHENZHEN HOLATEK CO. LTD.

Address:                      1001,10F,Building B4,KeXing Science Park,Nanshan, Shenzhen,China.

3.2. Product Description
Name of EUT:                  Home Projector

Trade Mark:                   Philips

Model No.:                    Screeneo S6

Listed Model(s)               -

Power supply:                 DC 19V

                              Model:GQ150-1900780-E1
Adapter information:          Input:100-240Va.c., 50/60Hz, 2.0A Max
                              Output:19Vd.c., 7.8A


3.3. EUT operation mode
Test mode                                                      Describe
USB playing                   Keep the EUT in USB playing status
HDMI playing                  Keep the EUT in HDMI playing status
LAN                           Keep the EUT in LAN status
Pre-scan all of above modes. Only show HDMI mode which is the worst case on the report.




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                          Page 6 of 17                             Issued: 2019-05-24



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                      Page 7 of 17                          Issued: 2019-05-24



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.28 dB           (1)
Radiated Emissions                           1~18GHz                      5.16 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.35 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                         Page 8 of 17                       Issued: 2019-05-24


4.5. Equipments Used during the Test

 ●     Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26

 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ○     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ○     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2019/04/26       2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                          Page 9 of 17                        Issued: 2019-05-24



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                        Limit (dBuV)
          Frequency range (MHz)
                                                         Quasi-peak                        Average
                  0.15-0.5                                66 to 56*                        56 to 46*
                    0.5-5                                    56                               46
                    5-30                                     60                               50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


  Level [dBpVJ

                                          i                                  Pticro                   i
                                          i                                  bon a a                  i
                                  ohoboled ooo oc cccod enc oo  becodecdeckedokobds cce c~——~— ae———— 1
                                          i            i        i   60    d  o d a d a                i     i
                                  oboboledi en 8 8888i e n o    i
                                                                hsnbbo oo qo
                                                                          d  ob a a                   i     i
                                                                             bor g a a                i
                       Dob D d 0OE Dd d d     00000004 0000 0P 00 0d 0 ob ul                          i     i
                                          i                i    i   ooo
                                          7                7    7   m—1      a a a                    i     i
                                        old   lc lc c oc od 2000b od e daislia       all    god=g>~~ 1
                                                                          i             i
                                                  AALILQOCAOCRCCARS O oob S               » pas enac 9 — C :
                                                                i   j                   i
                                                       NUALC                 !          !




                                                       Frequency [Hz]

x x xMES    GM1905065005_fin



MEASUREMENT RESULT:                       "GM1905065005_fin"
5/6/2019          9:42AM
    Frequency                Level      Transd           Limit          Margin   Detector      Line       PE
                 MHz           dBuy              dB        dBuv             dB
      0.177000               59.00             9 .9            65          5.6   QP            L1       GND
      0 .262500              53.410            9 .9            61          §.0   P             L1       GND
      0. 424500              40.80             9 .9            57         16.6   P             L1       GND
      4.573500               34 .60            9 .9            56         21.4   P             L1       GND
      9.271500               38 .60           10.1             60         21.4   P             L1       GND
    12.790500                34.80            10.1             60         25.2   QP            L1       GND

MEASUREMENT RESULT:                           "GM1905065005_fin2"
5/6/2019          9: 42AM
     Frequency                Level      Transd           Limit         Margin   Detector       Line       PE
                 MHz           dBuy              dB         dBuv            dB
       0.172500               37.30             9.9             55        17.5   AV             L1       GND
       0.262500               48 .40            9.9             51         3.0   AV             L1       GND
       0.433500               36.00             9.9             47        11.2   AV             L1       GND
       0. 627000              24 .10            9.9             46        21.9   AV             L1       GND
       4.420500               26.50             9 .9            46        19.5   AV             L1       GND
        9.280500              30 .50          10.1              50        19.5   AV             L1       GND


  Level [dBpVJ




                                                                                                   i      i
                                          i.
                               ol.__

                                                                                                   1      1
                                                                                                   1      1
                 300k 400k     600k 800k 1M                                               2M       3M    4M   5M   61
                                                                                      Frequency [Hz]

x x xMES    GM1905065004_fin



MEASUREMENT RESULT :                      "GM1905065004_fin"
5/6/2019  9:34AM
   Frequency     Level                  Transd                                          Limit          Margin           Detector       Line        PE
         MHz      dBuv                                        dB                         dBuv                 dB

      0.172500               52.60                                                           65          12.2           OP                        GND
                                               © t w w to w

                                                                  © w w t to t




                                                                                                                                   2 2 2 2 Z4 Z
      0.267000               48.60                                                           61          12.6           OP                        GND
      0.451500               38.80                                                           57          18.0           OP                        GND
      0. 613500              38 .60                                                          56          17.4           QP                        GND
      0.789000               37.80                                                           56          18.2           OP                        GND
      4.951500               37.00         1                                                 56          19.0           OP                        GND

MEASUREMENT RESULT:                        "GM1905065004_fin2"
5/6/2019          9:34AM
     Frequency               Level      Tran sd                                         Limit           Margin          Detector           Line    PE
           MHz                dBuv                                dB                     dBuVv                dB

       0.262500              42.40                                                            51           9.0          AV                        GND
                                                   © t w to w w

                                                                      & o t to t to




                                                                                                                                       122 Z= 4




       0 .447000             28 .90                                                           47          18.0          AV                        GND
       0 . 618000            32.70                                                            46          13.3          AV                        GND
       0.784500              28 .30                                                           46          17.7          AV                        GND
       0. 942000             23.30                                                            46          22.7          AV                        GND
       4.875000              30 .30                                                           46          15.7          AV                        GND


Report No : CHTEW19050099                       Page 12 of 17                         Issued: 2019-05-24



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                     Page 13 of 17                       Issued: 2019-05-24


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


  Level [dBpV/im]
80
70

60

50

40
30

20
10

 0
                                                                     Frequency [H2z]

x x xMES        GM1905106118_red



MEASUREMENT RESULT:                      "GM1905106118_red"
5/10/2019            7:10PM
         Frequency          Level        Transd       Limit             Margin         Det.     Height       Azimuth     Polarization
               MHz         dBuV/m            dB       dBu¥/m                dB                      cm           deg

     297.720000             42.10         —7.5             46   .0           3.9       QP        100    .0     15.00     HORTIZONTAL
     338 .460000            37.70         —6. 0            46   .0           8.3       OP        100    .0     54.00      HORIZONTAL
     594.540000             38 .20         0.7             46   .0           7.8       P         100    .0      6.00     HORIZONTAL
     743.920000             39.00          3.4             46   .0           7.0       P         100    .0    212.00      HORIZONTAL
     794.360000             37 .80         4.1             46   .0           8.2       oP        100    .0    212.00      HORIZONTAL
     930 .160000            38 .70         6.7             46   .0           7.3       P         100    .0    321.00      HORIZONTAL
         Level (dBuVim)
 80
                                                                                                                      FCC CLASS—B PK
 70

 60
                                                                                                                      FCC CLASS—B AV
 50

 40

 30

 20

 10

     0
         1000    1200         1500                   2000                                                                 5000     6000
Mark              Frequency     Reading           Antenna            Cable       Preamp         Level        Limit      Over     Remark
                    MHz          dBuV/m            ds                 dB          ds           dBuV/m        dBuV/m     limit
     1          1143.83         54.70             25. 86             4.53      37. 26         47.83          74.00     —~26.17   Peak
     2          1483.18         51.29             25.82              5.24      37.08          45.27          74.00     —28.73    Peak
     3          1855.51         49. 87            25. 34             6.05      37.46          43.50          74.00     —30.20    Peak
     4          2529 .78        52.73             27.38              6.56      37.59          49.38          74.00     —24.62    Peak
     5          2747.12         51.40             25.10              7.25      37.58          49.17          74.00     —24.83    Peak
     6          3672.30         44 .95            29.30              8.35      37.00          45.50          74.00     —25.40    Peak


  Level [dBuV/m]

80
70
60
50

40

30

20




                                                                                        Sk—————
 10




                                                                                                         8———
 0




                                                                                                   8.


                                                                                                         3|
                                                                                                                    M        800M    16




                                                                                        oo
                                                                                        o
                                                                                        5

                                                                                                   m
                                                                                                   f=]
                                                                                                   <
                                                                                                         on
                                                                                                         o
                                                                                                         <
                                                                                                         o
                                                                                                         o
                                                            Frequency [H2z]

x x xMES     GML905106120 red


MEASUREMENT RESULT:                  "GM1905106120_red"
5/10/2019          7:149M
      Frequency          Level      Transd         Limit      Margin          Det.        Height       Azimuth      Polarization
            MHz         dBu¥/m          dB         dBuV/m         dB                          cm           deg

   31.940000             34 .40      —13.3          40 .0          5.6        P             100   .0     93.00      VERTICAL
  524.700000             39.80        —1.5          46 .0          6.2        P             100   .0     44.00       VERTICAL
  600 . 360000           35.80         0 .8         46 .0         10.2        OP            100   .0     55.00       VERTICAL
  666320000              37 .20        1.7          46 .0          8.8        oP            100   .0      0.00       VERTICAL
  800180000              37 .40        4.2          46 .0          8.6        P             100   .0      0.00      VERTICAL
  945. 680000            37.10         6.8          46.0           8.9        P             100   .0    305.00       VERTICAL

 8o Level (dBuVim)
                                                                                                                 FCC CLASS—B PK
 70

 60
                                                                                                                 FCC CLASS—B AV
 50          4               3                33                     3|5. .        $6

 40

 30

 20

 10

  0
      1000    1200           1500                  2000                                                              5000           6000

 Mark            Frequency    Reading         Antenna        Cable       Preamp           Level         Limit       Over       Remark
                   MHz         dBuV/m          dB             ds          dB             dBuV/m         dBuV/m       limit
      1      1156.19          52.30           25.96          4.56      37. 25           45.57           74.00      —28.43       Peak
      2      1483.18          52.34           25.82          5. 24     37.08            46.32           74.00      —27.68       Peak
      3      1855.51          54.16           25. 34         6.05      37.46            48.09           74.00      —25.91       Peak
      4      2529 .78         49.64           27.38          5.56      37.59            46.29           74.00      <27.74       Peak
      5      2747.12          50.63           28.10          7.25      37.58            48.40           74.00      —25.60       Peak
      6      2993. 84         49.92           28 .59         7.48      37.58            48.41           74.00      ~25.59       Peak




                                                                                           cope c > hn ge ce e    n e en      n n n qe >


Report No : CHTEW19050099                     Page 16 of 17                  Issued: 2019-05-24



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19050099                     Page 17 of 17                    Issued: 2019-05-24



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
    Reference to the test report No.: CHTEW19050094




                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2019-05-24 22:09:33
Document Modified: 2019-05-24 22:09:33

© 2025 FCC.report