Test report

FCC ID: 2ASRT-SCN450

Test Report

Download: PDF
FCCID_4346740

                                                   TEST REPORT
Report Reference No. .................... :               CHTEW19060135                   Report verification:

Project No. ...................................... :      SHT1901065806EW

FCC ID ............................................. :    2ASRT-SCN450

Applicant’s name ........................... :            Screeneo Innovation SA

Address ............................................. :   Route de Lully 5C, 1131 Tolochenaz, Switzerland

Manufacturer......................................:       SHENZHEN HOLATEK CO. LTD.
                                                          1001,10F,Building B4,KeXing Science Park,Nanshan,Shenzhen,
Address...............................................:
                                                          China.
Test item description .................... :              Home Projector

Trade Mark ....................................... :      Philips

Model/Type reference ....................... :            Screeneo S4

Listed Model(s) ................................. :       -

Standard ......................................... :      47 CFR FCC Part 15 Subpart B

Date of receipt of test sample………..:                      Mar 30,2019

Date of testing…………………………:                                Mar 31,2019- Jun 19,2019

Date of issue…………………………...:                               Jun 20,2019

Result .................. …………………...:                     Pass

Compiled by
( position+printed name+signature) .. :                   File administrators Silvia Li
Supervised by
( position+printed name+signature) .. :                   Project Engineer Aaron Fang
Approved by
( position+printed name+signature) .. :                   RF Manager Hans Hu


Testing Laboratory Name ............. :                   Shenzhen Huatongwei International Inspection Co., Ltd.

Address ............................................. :   1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao,
                                                          Gongming, Shenzhen, China

Shenzhen Huatongwei International Inspection Co., Ltd. All rights reserved.

This publication may be reproduced in whole or in part for non-commercial purposes as long as the
Shenzhen Huatongwei International Inspection Co., Ltd. is acknowledged as copyright owner and source of
the material. Shenzhen Huatongwei International Inspection Co., Ltd. takes no responsibility for and will not
assume liability for damages resulting from the reader's interpretation of the reproduced material due to its
placement and context.

The test report merely corresponds to the test sample.




                                                                    Page: 1 of 17


Report No : CHTEW19060135                                                Page 2 of 17                                                          Issued: 2019-06-20




                                                                         Contents

1.       TEST STANDARDS AND REPORT VERSION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

1.1.    Test Standards                                                                                                                                                    3
1.2.    Report version information                                                                                                                                        3

2.       TEST DESCRIPTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4



3.       SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

3.1.    Client Information                                                                                                                                                5
3.2.    Product Description                                                                                                                                               5
3.3.    EUT operation mode                                                                                                                                                5

4.       TEST ENVIRONMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

4.1.    Address of the test laboratory                                                                                                                                    6
4.2.    Test Facility                                                                                                                                                     6
4.3.    Environmental conditions                                                                                                                                          7
4.4.    Statement of the measurement uncertainty                                                                                                                          7
4.5.    Equipments Used during the Test                                                                                                                                   8

5.       TEST CONDITIONS AND RESULTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

5.1.    Conducted Emissions Test                                                                                                                                          9
5.2.    Radiated Emissions Test                                                                                                                                           12

6.       TEST SETUP PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 6



7.       EXTERNAL AND INTERNAL PHOTOS OF THE EUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 7




Shenzhen Huatongwei International Inspection Co., Ltd.                                                     Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                         Page 3 of 17                         Issued: 2019-06-20



1. TEST STANDARDS AND REPORT VERSION
1.1. Test Standards
The tests were performed according to following standards:
47 CFR FCC Part 15 Subpart B - Unintentional Radiators
ANSI C63.4: 2014 – American National Standard for Methods of Measurement of Radio-Noise Emissions from
Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40GHz


1.2. Report version information
      Revision No.                Date of issue                          Description
          N/A                      2019-06-20                              Original




Shenzhen Huatongwei International Inspection Co., Ltd.           Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                       Page 4 of 17                               Issued: 2019-06-20



2. TEST DESCRIPTION
               Test Item                         Section in CFR 47                Result       Test Engineer
         Conducted Emissions                          15.107(a)                    PASS          Tony Duan
          Radiated Emissions                          15.109(a)                    PASS         Michael Jie


Note: The measurement uncertainty is not included in the test result.




Shenzhen Huatongwei International Inspection Co., Ltd.                  Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                      Page 5 of 17                           Issued: 2019-06-20



3. SUMMARY
3.1. Client Information
Applicant:                    Screeneo Innovation SA

Address:                      Route de Lully 5C, 1131 Tolochenaz, Switzerland

Manufacturer:                 SHENZHEN HOLATEK CO. LTD.

Address:                      1001,10F,Building B4,KeXing Science Park,Nanshan, Shenzhen,China.

3.2. Product Description
Name of EUT:                  Home Projector

Trade Mark:                   Philips

Model No.:                    Screeneo S4

Listed Model(s)               -

Power supply:                 DC 19.0V

                              Model:GQ150-1900780-E1
Adapter information:          Input:100-240Va.c., 50/60Hz, 2.0A Max
                              Output:19Vd.c., 7.8A


3.3. EUT operation mode
Test mode                                                      Describe
USB playing                   Keep the EUT in USB playing status
HDMI playing                  Keep the EUT in HDMI playing status
LAN                           Keep the EUT in LAN status
Pre-scan all of above modes. Only show HDMI mode which is the worst case on the report.




Shenzhen Huatongwei International Inspection Co., Ltd.             Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                          Page 6 of 17                             Issued: 2019-06-20



4. TEST ENVIRONMENT
4.1. Address of the test laboratory
Laboratory: Shenzhen Huatongwei International Inspection Co., Ltd.
Address: 1/F, Bldg 3, Hongfa Hi-tech Industrial Park, Genyu Road, Tianliao, Gongming, Shenzhen, China
Phone: 86-755-26748019 Fax: 86-755-26748089
4.2. Test Facility
The test facility is recognized, certified, or accredited by the following organizations:

CNAS-Lab Code: L1225

Shenzhen Huatongwei International Inspection Co., Ltd. has been assessed and proved to be in compliance
with CNAS-CL01 Accreditation Criteria for Testing and Calibration Laboratories (identical to ISO/IEC17025:
2005 General Requirements) for the Competence of Testing and Calibration Laboratories.

A2LA-Lab Cert. No. 3902.01

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been accredited by A2LA for
technical competence in the field of electrical testing, and proved to be in compliance with ISO/IEC 17025:
2005 General Requirements for the Competence of Testing and Calibration Laboratories and any additional
program requirements in the identified field of testing.

FCC-Registration No.: 762235

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory has been registered and fully
described in a report filed with the FCC (Federal Communications Commission). The acceptance letter from
the FCC is maintained in our files. Registration 762235.

IC-Registration No.: 5377B-1

Two 3m Alternate Test Site of Shenzhen Huatongwei International Inspection Co., Ltd. has been registered by
Certification and Engineering Bureau of Industry Canada for the performance of radiated measurements with
Registration No. 5377B-1.

ACA

Shenzhen Huatongwei International Inspection Co., Ltd. EMC Laboratory can also perform testing for the
Australian C-Tick mark as a result of our A2LA accreditation.




Shenzhen Huatongwei International Inspection Co., Ltd.                   Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                      Page 7 of 17                              Issued: 2019-06-20



4.3. Environmental conditions
During the measurement the environmental conditions were within the listed ranges:
Temperature:                                         15~35°C
Relative Humidity:                                       30~60 %
Air Pressure:                                            950~1050mba



4.4. Statement of the measurement uncertainty
The data and results referenced in this document are true and accurate. The reader is cautioned that there
may be errors within the calibration limits of the equipment and facilities. The measurement uncertainty was
calculated for all measurements listed in this test report acc. to CISPR 16 - 4 „Specification for radio
disturbance and immunity measuring apparatus and methods – Part 4: Uncertainty in EMC
Measurements“ and is documented in the Shenzhen Huatongwei International Inspection Co., Ltd quality
system acc. to DIN EN ISO/IEC 17025. Furthermore, component and process variability of devices similar to
that tested may result in additional deviation. The manufacturer has the sole responsibility of continued
compliance of the device.

Hereafter the best measurement capability for Shenzhen Huatongwei laboratory is reported:

                                                                       Measurement
                Test                             Range                                     Notes
                                                                        Uncertainty
Radiated Emissions                         30~1000MHz                     4.90 dB           (1)
Radiated Emissions                           1~18GHz                      4.96 dB           (1)
Conducted Disturbance                      0.15~30MHz                     3.02 dB           (1)
(1) This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=1.96.




Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                         Page 8 of 17                              Issued: 2019-06-20


4.5. Equipments Used during the Test

 ●     Conducted Emission
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)

 ●     Shielded Room         Albatross projects        N/A             N/A        2018/09/28       2023/09/27

 ●     EMI Test Receiver           R&S                 ESCI          101247       2018/10/27       2019/10/26

 ●     Artificial Mains      SCHWARZBECK            NNLK 8121          573        2018/10/27       2019/10/26

 ●     Pulse Limiter               R&S               ESH3-Z2         100499       2018/10/27       2019/10/26

 ●     RF Connection Cable   HUBER+SUHNER             EF400            N/A        2018/11/15       2019/11/14

 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A
       Single Balanced
 ○                                 FCC            FCC-TLISN-T2-02    20371        2018/10/28       2019/10/27
       Telecom Pair ISN
       Two Balanced
 ○                                 FCC            FCC-TLISN-T4-02    20373        2018/10/28       2019/10/27
       Telecom Pairs ISN
       Four Balanced
 ○                                 FCC            FCC-TLISN-T8-02    20375        2018/10/28       2019/10/27
       Telecom Pairs ISN
 ○     V-Network                   R&S               ESH3-Z6         100211       2018/10/27       2019/10/26

 ○     V-Network                   R&S               ESH3-Z6         100210       2018/10/27       2019/10/26

 ○     2-Line V-Network            R&S               ESH3-Z5         100049       2018/10/27       2019/10/26

 ●     Radiated Emission-6th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-02          N/A        2018/09/30       2021/09/29
       Chamber
 ●     EMI Test Receiver           R&S                 ESCI          100900       2018/10/28       2019/10/27

 ○     Loop Antenna                R&S               HFH2-Z2         100020       2017/11/20       2020/11/19
       Ultra-Broadband
 ●                           SCHWARZBECK             VULB9163          546        2017/04/05       2020/04/04
       Antenna
 ●     Pre-Amplifer          SCHWARZBECK             BBV 9742          N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER              N/A             N/A        2018/09/28       2019/09/27
 ●     RF Connection Cable   HUBER+SUHNER          SUCOFLEX104      501184/4      2018/09/28       2019/09/27
 ●     Test Software               R&S                ES-K1            N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A

 ●     Radiated emission-7th test site
                                                                                 Last Cal. Date   Next Cal. Date
Used      Test Equipment       Manufacturer          Model No.      Serial No.
                                                                                 (YY-MM-DD)        (YY-MM-DD)
       Semi-Anechoic
 ●                           Albatross projects     SAC-3m-01          N/A        2018/09/30       2021/09/29
       Chamber
 ●     Spectrum Analyzer           R&S                FSP40          100597       2018/10/27       2019/10/26

 ●     Horn Antenna          SCHWARZBECK              9120D           1011        2017/03/27       2020/03/26

 ○     Pre-amplifier              BONN             BLWA0160-2M      1811887       2018/11/14       2019/11/13

 ●     Pre-amplifier                CD               PAP-0102        12004        2018/11/14       2019/11/13
       Broadband Pre-
 ●                           SCHWARZBECK             BBV 9718       9718-248      2019/04/26       2020/04/25
       amplifier
 ●     RF Connection Cable   HUBER+SUHNER            RE-7-FH           N/A        2018/11/15       2019/11/14

 ●     RF Connection Cable   HUBER+SUHNER             RE-7-FL          N/A        2018/11/15       2019/11/14

 ●     Test Software               Audix                E3             N/A            N/A              N/A

 ●     Turntable             Maturo Germany          TT2.0-1T          N/A            N/A              N/A

 ●     Antenna Mast          Maturo Germany        CAM-4.0-P-12        N/A            N/A              N/A


Shenzhen Huatongwei International Inspection Co., Ltd.              Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                          Page 9 of 17                          Issued: 2019-06-20



5. TEST CONDITIONS AND RESULTS
5.1. Conducted Emissions Test
LIMIT
FCC CFR Title 47 Part 15 Subpart B Section 15.107:
                                                                        Limit (dBuV)
          Frequency range (MHz)
                                                         Quasi-peak                      Average
                  0.15-0.5                                66 to 56*                      56 to 46*
                    0.5-5                                    56                             46
                    5-30                                     60                             50
* Decreases with the logarithm of the frequency.

TEST CONFIGURATION




TEST PROCEDURE
1. The EUT was setup according to ANSI C63.4:2014
2. The EUT was placed on a plat form of nominal size, 1 m by 1.5 m, raised 10 cm above the conducting
   ground plane. The vertical conducting plane was located 40 cm to the rear of the EUT. All other surfaces
   of EUT were at least 10 cm from any other grounded conducting surface.
3. The EUT and simulators are connected to the main power through a line impedance stabilization
   network (LISN). The LISN provides a 50ohm / 50uH coupling impedance for the measuring equipment.
4. The peripheral devices are also connected to the main power through a LISN. (Please refer to the block
   diagram of the test setup and photographs)
5. Each current-carrying conductor of the EUT power cord, except the ground (safety) conductor,was
   individually connected through a LISN to the input power source.
6. The excess length of the power cord between the EUT and the LISN receptacle were folded back and
   forth at the center of the lead to form a bundle not exceeding 40 cm in length.
7. Conducted emissions were investigated over the frequency range from 0.15MHz to 30MHz using a
   receiver bandwidth of 9 kHz.
8. During the above scans, the emissions were maximized by cable manipulation.

TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable




Shenzhen Huatongwei International Inspection Co., Ltd.                Report Template Version: V01 (2018-01)


  Level [dBpVJ




                 300k   400k    600k    800k 1
                                                                                   Frequency [Hz]

x x xMES    GM1905235096_fin



MEASUREMENT RESULT:                          "GM1905235096_fin"
5/23/2019   8:03PM
   Frequency     Level                     Tran sd                                   Limit          Margin    Detector    Line     PE
          MHz      dBuv                                         dB                    dBuv              dB

      0.172500                 53.00                                                      65          11.8    OP          L1      GND
                                                   t tb

                                                                    & 0 w w i io




      0.442500                 40.30                                                      57          16.7    QP          L1      GND
      1.432500                 33.70                                                      56          22.3    QP          L1      GND
      2.481000                 40.10              9.                                      56          15.9    QP          L1      GND
      4.924500                 46.20             10.                                      56           9.8    QP          L1      GND
      5.311500                 49.10             10.                                      60          10 .9   QP          L1      GND

MEASUREMENT RESULT:                          "GM1905235096_fin2"
5/23/2019               8:03PM
     Frequency               Level         Transd                                   Limit           Margin    Detector   Line     PE
           MBz                 dBuv            dB                                    dBuv               dB

       0.177000                49.00                                                      55           5.6    AV         L1      GND
                                                 p t t t uD p

                                                                to o to to td o




       0.343500                35.40                                                      49          13.7    AV         L1      GND
       0.784500                30.00                                                      46          16.0    AV         L1      GND
       0.906000                28 .20                                                     46          17.8    AV         L1      GND
       0.969000                24 .60                                                     46          21.4    AV         L1      GND
       2.832000                33.60                                                      46          12.4    AV         L1      GND


  Level [dBpVJ




                                                Frequency [Hz]

x x xMES    GM1905235095_fin



MEASUREMENT RESULT:                    "GM1905235095_fin"
5/23/2019          8:01PM
     Frequency             Level      Transd      Limit          Margin   Detector   Line    PE
                 MHz           dBuv       dB        dBupv            dB
       0 .168000           54.00         9.9            65         11.1   QP         N      GND
       0 .343500           41.20         9.9            59         17.9   QP         N      GND
       0.883500            35.70         9.9            56         20.3   QP         N      GND
       1.122000            33.70         9.9            56         22.3   QP         N      GND
       2.125500            37.70         9 .9           56         18.3   OP         N      GND
       4.942500            45.00        10 .0           56         11.0   QP         N      GND

MEASUREMENT RESULT:                    "GM1905235095_fin2"

5/23/2019  8:01PM
   Frequency    Level                 Transd      Limit          Margin   Detector   Line    PE
                 MHz           dBuv       dB        dBuV             dB
       0.172500            47.70         9 .9           55          7.1    AV        N      GND
       0. 343500           36.10         9 .9           49         13.0   AV         N      GND
       0. 456000           29.80         9 .9           47         17.0   AV         N      GND
       0.784500            31.70         9 .9           46         14.3   AV         N      GND
       1.243500            30 .40        9 .9           46         15.6   AV         N      GND
       2.130000            30 .50        9 .9           46         15.5   AV         N      GND


Report No : CHTEW19060135                       Page 12 of 17                              Issued: 2019-06-20



5.2. Radiated Emissions Test
LIMIT

FCC CFR Title 47 Part 15 Subpart B Section 15.109
              Frequency                       Limit (dBuV/m @3m)                              Value
             30MHz-88MHz                                   40.00                           Quasi-peak
             88MHz-216MHz                                  43.50                           Quasi-peak
            216MHz-960MHz                                  46.00                           Quasi-peak
             960MHz-1GHz                                   54.00                           Quasi-peak
                                                           54.00                             Average
              Above 1GHz
                                                           74.00                              Peak

TEST CONFIGURATION

    30MHz ~ 1GHz




    Above 1GHz




TEST PROCEDURE

1.   The EUT was tested according to ANSI C63.4:2014.
2.   The EUT is placed on a turn table which is 0.8 meter above ground.
3.   The turn table is rotated 360 degrees to determine the position of the maximum emission level.
4.   The EUT waspositioned such that the distance from antenna to the EUT was 3 meters.
5.   The antenna is scanned from 1 meter to 4 meters to find out the maximum emission level. Thisis
     repeated for both horizontal and vertical polarization of the antenna.
6.   Use the following spectrum analyzer settings
     (1) Span shall wide enough to fully capture the emission being measured;
     (2) Below 1GHz,
          RBW=120KHz, VBW=300KHz, Sweep=auto, Detector function=peak, Trace=max hold;
          If the emission level of the EUT measured by the peak detectoris 3 dB lower than the applicable limit,
          the peak emission level will be reported. Otherwise, theemission measurement will be repeated using
          the quasi-peak detector and reported.
     (3) From 1GHz to 5th harmonic, RBW=1MHz, VBW=3MHz

Shenzhen Huatongwei International Inspection Co., Ltd.               Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                     Page 13 of 17                           Issued: 2019-06-20


TEST MODE:
Please refer to the clause 3.3

TEST RESULTS

   Passed               Not Applicable


Note: Final Level =Receiver Read level + Antenna Factor + Cable Loss – Preamplifier Factor




Shenzhen Huatongwei International Inspection Co., Ltd.            Report Template Version: V01 (2018-01)


     Level [dBpV/m]
80

70
60

50

40
30

20

 10




                                                                                     8| ——




                                                                                                      3.——
                                                                                               8.


                                                                                                      3|
                                                                                                                   M      800M    1G




                                                                    io
                                                                    o
                                                                    o
                                                                    5



                                                                                     w
                                                                                     0
                                                                                     5S

                                                                                               m
                                                                                               f=]
                                                                                               <
                                                                                                      o
                                                                                                      6
                                                                                                      s
                                                                                                      o
                                                                                                      o
                                                            Frequency [H2z]

x x xMES        GM1906066055_red



MEASUREMENT RESULT:                    "GM1906066055_red"
6/6/2019          5:12PM
      Frequency         Level       Transd      Limit         Margin          Det.     Height       Azimuth        Polarization
            MHz        dBpV/m           dB      dBpV/m            dB                       cm           deg

      57.160000            23.40       —5.5         40 .0          16.6       OP        100    .0    330.00        HORIZONTAL
     156.100000            37 .50      —9.8         43.5            6.0       P         300    .0    245.00        HORIZONTAL
     196.840000            33.10       —5.9         43.5           10.4       OP        100    .0     80.00         HORTIZONTAL
     299.660000            34 .30      —3.5         46.0           11.7       OP        100    .0     44.00         HORIZONTAL
     452.920000            39.40        0.5         46.0            6.6        QP       100    .0    216.00        HORTIZONTAL
     920 .460000           40 .10      10 .7        46.0            5.9       P         300    .0     85.00        HORIZONTAL

SOLQ\'E}I (dBuVim)
                                                                                                                FCC CLASS—B PK
70

60
                                                                                                                FCC CLASS—B AV

50

40

30

20

10


 0
      1000    1200           1500              2000                                                                    5000      6000
Mark            Frequency      Reading     Antenna          Cable      Preamp          Level        Limit        Over         Remark
                  MHz           dBuV/m      ds               dB         dB            dBuV/m        dBuV/m        limit
     1       1066.63           46.53       25. 40           5.14      37.79          39.28          74.00       —34.72         Peak
     2       1194.09           42.93       26. 25           5.51      37.65          37.04          74.00       —36.96         Peak
     5       1341.58           42.07       26. 07           5.39      37.29          36.74          74.00       —37.26         Peak
     4       1639.72           43.30       25. 02           5.46      37.72          37.06          74.00       —36.94         Peak
     5       2534.31           44.90       27 .41           5.18      37.50          42.99          74.00       —31.01         Peak
     6       2575.51           43.59       27.66            8.30      37.63          41.92          74.00       —32.08         Peak




                       n e revennr rean en en es winvcg se                             nrepns        rpersees    n se         n en qs e e es ,


  Level [dBpV/im]
80
70
60
50

40

30

20
              i                                       i                                       i
10            i          i              i             i                                       i                          i
              i          i              i             i                                       i                          i
              1          1              1             1                                       1                          1
      30M    40M        5OM    6OM 70M           100M                        200M           300M       400M    500M 6OOM            BOOM    1G
                                                                    Frequency [Hz]

x x x MBS     GM1906066054_red



MEASUREMENT RESULT:                          "GM1906066054_red"

6/6/2019            5:08PM
         Frequency             Level        Transd         Limit       Margin        Det.    Height        Azimuth           Polarization
                  MHz         dBuV/m            dB         dBuV/m             dB                     cm          deg

      31. 940000               30 .70         —9.3          40 .0            9.3     P            100. 0       91.00          VERTICAL
      61.040000                25.50          —6.4          40 .0           14.5     P            100 .0      287.00         VERTICAL
     150280000                 27.30         —10.0          43.5            16.2     P            100. 0      203.00         VERTICAL
     206.540000                29.80          —6.6          43.5            13.7     P            100. 0      276.00         VERTICAL
     439. 340000               40 .00          0.3          46 .0            6.0      oP          100 .0      203.00         VERTICAL
     955. 380000               38.50          10 .9         46 .0            7.5     oP           100 .0      276.00         VERTICAL

 8‘]Level (dBuVim)
                                                                                                                      FCC CLASS—B PK
 70

 60                                                                                                                       n
                                                                                                                      FCC CLASS—B AV
 50

 40

 30

 20

 10


  G100[]      1200               1500                     2000                                                               5000          6000
Mark           Frequency           Reading            Antenna        Cable     Preamp         Level           Limit          Over      Remark
                 MHz                dBuV/m             dB             ds         ds          dBuV/m           dBuV/m         limit
     1       1191.95               46.11              26. 24         5.50      37.65        40.20             74.00          —33.50        Peak
     2       1639.72               44.11              25.02          6.46     37.72         37.87             74.00      ~36.13            Peak
     3       2160.75               41.24              27.19          7.56     38.10         37.89             74.00      +36:44            Peak
     4       2538.86               45.17              27. 44         8.20     37.51         43.30             74.00      —30.70            Peak
     5       2612.70               43.92              27.84          8.41     37.44         42.73             74.00      +31.27            Peak
     6       2771.84               38. 29             28.10          8.85     34.75         40.49             74.00      —33.51            Peak


Report No : CHTEW19060135                     Page 16 of 17                      Issued: 2019-06-20



6. TEST SETUP PHOTOS OF THE EUT
Conducted Emissions (AC Mains)




Radiated Emissions (30MHz-1GHz)




Radiated Emissions (Above 1GHz)




Shenzhen Huatongwei International Inspection Co., Ltd.        Report Template Version: V01 (2018-01)


Report No : CHTEW19060135                     Page 17 of 17                        Issued: 2019-06-20



7. EXTERNAL AND INTERNAL PHOTOS OF THE EUT
    Reference to the test report No.: CHTEW19060130




                                        --------End of Report--------




Shenzhen Huatongwei International Inspection Co., Ltd.          Report Template Version: V01 (2018-01)



Document Created: 2019-06-22 12:18:46
Document Modified: 2019-06-22 12:18:46

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC