Test Report

FCC ID: 2ASQ9CL830-01

Test Report

Download: PDF
FCCID_4467109

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                    ShenZhen chileaf electronics Co., Ltd

            5#D Skyworth Innovation valley, No.8, Tongtou 1st Rd, ShiYan, BaoAn, ShenZhen, China



                                        FCC ID: 2ASQ9CL830-01


            Report Type:                                 Product Name:
            Original Report                              armband heart rate monitor


                  Report Number:           RDG190813004 -00A


                      Report Date:         2019-09-28


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190813004-00A




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................7
  SUPPORT CABLE LIST AND DETAILS ............................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
SUMMARY OF TEST RESULTS ...............................................................................................................................9
FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE..........................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................11
FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS ......................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................13
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................16
  APPLICABLE STANDARD ............................................................................................................................................16
  EUT SETUP ................................................................................................................................................................16
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................17
  TEST PROCEDURE ......................................................................................................................................................17
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................17
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................18
  TEST DATA ................................................................................................................................................................18
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................27
  APPLICABLE STANDARD ............................................................................................................................................27
  TEST PROCEDURE ......................................................................................................................................................27

                                                                                                                                                            Page 2 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                           Report No.: RDG190813004-00A


    TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................27
    TEST DATA ................................................................................................................................................................28
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................29
  APPLICABLE STANDARD ............................................................................................................................................29
  TEST PROCEDURE ......................................................................................................................................................29
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................29
  TEST DATA ................................................................................................................................................................29
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................31
  APPLICABLE STANDARD ............................................................................................................................................31
  TEST PROCEDURE ......................................................................................................................................................31
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................31
  TEST DATA ................................................................................................................................................................31




                                                                                                                                                             Page 3 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190813004-00A

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                    EUT Name:          armband heart rate monitor
                    EUT Model:         CL830
               Multiple Models:        CL831, CL832, CL833
           Operation Frequency:        2402-2480MHz
     Maximum Peak Output Power
                                       0.99dBm
                   (Conducted):
              Modulation Type:         GFSK
            Rated Input Voltage:       DC 3.7V from battery or DC 5V from USB port
            External Dimension:        50*30*10(mm)
                 Serial Number:        190813005
            EUT Received Date:         2019-08-14

Note: Model CL830 was selected for fully testing, the detailed information about the difference among CL831, CL832,
CL833 and model CL830 can be referred to the declaration letter which was stated and guaranteed by the
manufacturer.


Objective
This report is prepared on behalf of the ShenZhen chileaf electronics Co., Ltd in accordance with Part 2,
Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.207, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
No related submittal.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                                      Page 4 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190813004-00A

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                             Page 5 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                Report No.: RDG190813004-00A

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                      Frequency                                     Frequency
                Channel                                       Channel
                                        (MHz)                                         (MHz)
                   0                     2402                   20                     2442
                   1                     2404                   …                       …
                   …                      …                     …                       …
                   …                     …                      …                      …
                    ..                   …                      38                    2478
                   19                   2440                    39                    2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The software ' nRFgo Studio ' was used for testing, which was provided by manufacturer and the
maximum power was configured as below table:

                                               Frequency
                           Channel                                      Power level
                                                 (MHz)
                            Low                   2402                       /
                           Middle                 2440                       /
                           High                   2480                       /

The duty cycle as below:

                               Ton                  Ton+off             Duty Cycle
                              (ms)                  (ms)                   (%)
                              0.208                 0.629                 33.07




                                                                                                   Page 6 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                 Report No.: RDG190813004—00A


                                                 Duty Cycle

              ®      .




                                                                      i8
Local Support Equipment List and Details

       Manufacturer           Description              Model           Serial Number
         Unknown                  Adapter                M4                  /



Support Cable List and Details


          Cable          Shiclding      Ferrite Core   Lenath   From Port              To
       Description         Type                          (m)
        USB cable           No              No           0.8     Adapter           EUT




                                                                                       Page 7 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190813004-00A


Block Diagram of Test Setup




                                                                      Page 8 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190813004-00A


SUMMARY OF TEST RESULTS

              FCC Rules                              Description of Test               Result
       FCC§15.247 (i) & §1.1310 &
                                                       RF Exposure                   Compliance
               §2.1093
              FCC §15.203                           Antenna requirement              Compliance

            FCC §15.207(a)                   AC line conducted emissions             Compliance
         FCC §15.205, §15.209,
                                                    Spurious emissions               Compliance
              §15.247(d)
           FCC §15.247(a)(2)                   6 dB emission bandwidth               Compliance

           FCC §15.247(b)(3)              Maximum conducted output power             Compliance

            FCC §15.247(d)            100 kHz Bandwidth of frequency band edge       Compliance

            FCC §15.247(e)                      Power spectral density               Compliance




                                                                                                Page 9 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190813004-00A

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 1.0 dBm (1.26 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
= 1.26/5*(√2.480) = 0.4< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                               Page 10 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190813004-00A

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement, and the antenna gain is -1.0 dBi, fulfill the requirement of
this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 11 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190813004-00A

FCC §15.207 (a)– AC LINE CONDUCTED EMISSIONS
Applicable Standard
FCC§15.207(a)


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207.

The spacing between the peripherals was 10 cm.

The adapter was connected to the main lisn with a 120 V/60 Hz AC power source.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




                                                                                              Page 12 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190813004-00A

Test Procedure

During the conducted emission test, the adapter was connected to the first LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All data was recorded in the Quasi-peak and average detection mode.


Corrected Amplitude & Margin Calculation
The basic equation is as follows:

VC = VR + AC + VDF
Cf = AC + VDF

Herein,
VC (cord. Reading): corrected voltage amplitude
VR: reading voltage amplitude
Ac: attenuation caused by cable loss
VDF: voltage division factor of AMN
Cf: Correction Factor

The “Margin” column of the following data tables indicates the degree of compliance within the
applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation
for margin calculation is as follows:

                                    Margin = Limit – Corrected Amplitude


Test Equipment List and Details

                                                                     Serial         Calibration   Calibration
      Manufacturer              Description           Model
                                                                    Number             Date        Due Date
         Unknown               Coaxial Cable       C-NJNJ-50        C-0200-01       2018-09-05     2019-09-05
           R&S                 Test Software         EMC32        Version8.53.0        N/A            N/A
           R&S              Two-line V-network      ENV 216          101614         2018-12-10     2019-12-10
           R&S               EMI Test Receiver        ESCI           101121         2019-05-09     2020-05-09

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 13 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                              Report No.: RDG190813004-00A

Test Data
    Environmental Conditions
             Temperature:                          26.4oC
        Relative Humidity:                          61%
           ATM Pressure:                          100.6kPa
                    Tester:                        Sky Lu
                 Test Date:                      2019-08-27
Test Result: Compliance

Test Mode: Transmitting
    AC120 V, 60 Hz, Line:

                          80

                          70
                                                                                                        Quasi-Peak Limit
                          60
                                                                                                           Average Limit
                          50
          Level in dBμ




                          40

                          30

                          20

                          10

                          0
                          150k       300    400 500    800 1M           2M   3M     4M 5M 6    8 10M          20M      30M
                                                                  Frequency in Hz



                     Frequency             QuasiPeak       Bandwidth                  Corr.     Margin         Limit
                                                                             Line
                       (MHz)                (dBμV)           (kHz)                    (dB)       (dB)         (dBμV)
                      0.157652                40.3           9.000           L1       11.1       25.3           65.6
                         0.418016            29.0               9.000        L1        9.9       28.5           57.5
                         0.647640            29.5               9.000        L1        9.8       26.5           56.0
                         1.108377            28.3               9.000        L1        9.8       27.7           56.0
                         1.859513            28.1               9.000        L1        9.7       27.9           56.0
                         2.909785            28.9               9.000        L1        9.8       27.1           56.0

                         Frequency          Average        Bandwidth                   Corr.    Margin         Limit
                                                                             Line
                           (MHz)            (dBμV)           (kHz)                     (dB)      (dB)         (dBμV)
                          0.430682            25.8           9.000            L1        9.9      21.4           47.2
                         0.660657             26.5              9.000         L1        9.8      19.5           46.0
                         0.926623             25.9              9.000         L1        9.8      20.1           46.0
                         1.248947             25.7              9.000         L1        9.8      20.3           46.0
                         3.515338             24.6              9.000         L1        9.8      21.4           46.0
                         4.419352             24.3              9.000         L1        9.8      21.7           46.0




                                                                                                                       Page 14 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                            Report No.: RDG190813004-00A

    AC120 V, 60 Hz, Neutral:


                         80

                         70
                                                                                                      Quasi-Peak Limit
                         60
                                                                                                         Average Limit
                         50
          Level in dBμ




                         40

                         30

                         20

                         10

                          0
                          150k      300    400 500    800 1M           2M   3M     4M 5M 6   8 10M          20M      30M
                                                                 Frequency in Hz



                     Frequency            QuasiPeak       Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.389891               29.0           9.000            N       10.0      29.1           58.1
                         0.546852           28.7               9.000         N        9.8      27.3           56.0
                         0.993465           28.0               9.000         N        9.8      28.0           56.0
                         1.523953           28.1               9.000         N        9.8      27.9           56.0
                         3.119684           29.1               9.000         N        9.8      26.9           56.0
                         4.508181           29.0               9.000         N        9.8      27.0           56.0

                     Frequency             Average        Bandwidth                  Corr.    Margin         Limit
                                                                            Line
                       (MHz)               (dBμV)           (kHz)                    (dB)      (dB)         (dBμV)
                      0.430682               25.8           9.000            N        9.9      21.4           47.2
                         0.654116           25.8               9.000         N        9.8      20.2           46.0
                         0.926623           25.3               9.000         N        9.8      20.7           46.0
                         1.274051           25.7               9.000         N        9.8      20.3           46.0
                         3.182389           24.6               9.000         N        9.8      21.4           46.0
                         3.658074           24.3               9.000         N        9.8      21.7           46.0




                                                                                                                     Page 15 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190813004-00A

FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission below 1GHz tests were performed in the 10 meters chamber, above 1GHz tests were
performed in the 3 meters chamber B, using the setup accordance with the ANSI C63.10-2013. The
specification used was the FCC 15.209, and FCC 15.247 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.




                                                                                              Page 16 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190813004-00A

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 17 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190813004-00A

Test Equipment List and Details

                                                                       Serial       Calibration    Calibration
    Manufacturer           Description             Model
                                                                     Number            Date         Due Date
         R&S           EMI Test Receiver           ESCI               100035        2019-08-03     2020-08-03
        Farad            Test Software            EZ-EMC             V1.1.4.2          N/A            N/A
    Sunol Sciences          Antenna                 JB3             A060611-2       2017-08-25     2020-08-25
       Unknown           Coaxial Cable           C-NJNJ-50          C-1000-01       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0400-02       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0530-01       2018-09-24     2019-09-24
       Sonoma              Amplifier               310N               185914        2018-10-13     2019-10-13
        Agilent        Spectrum Analyzer          E4440A           SG43360054       2019-05-09     2020-05-09
    ETS-Lindgren         Horn Antenna              3115             000 527 35      2018-10-12     2021-10-12
      Ducommun                                                     1007726-01
                          Horn Antenna         ARH-4223-02                          2016-11-18     2019-11-18
     Technolagies                                                      1304
       Unknown            Coaxial Cable         C-SJSJ-50           C-0800-01       2018-09-05     2019-09-05
       Unknown            Coaxial Cable       C-2.4J2.4J-50         C-0700-02       2019-06-27     2020-06-27
                                             AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                 25-S-42
       Quinstar             Amplifier       QLW-18405536-JO        15964001001      2019-06-27     2020-06-27
                                            OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2019-06-16     2020-06-16
                                                    S
     Micro-tronics       High Pass Filter      HPM50111              S/N-G217       2019-06-16     2020-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

                      Test Items    Radiation Below 1GHz     Radiation Above 1GHz
                  Temperature:              24.1C                   27.3C
             Relative Humidity:              54%                      58%
                ATM Pressure:             100.7 kPa                 100.4kPa
                         Tester:           Ade Xiao                 Lucy Lu
                      Test Date:         2019-08-23               2019-08-20

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                    Page 18 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190813004-00A

1) 30MHz-1GHz (Low Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     30.9700       28.37           peak           -8.40       19.97        40.00         20.03
    162.8900       28.87           peak          -12.88       15.99        43.50         27.51
    291.9000       27.79           peak          -11.30       16.49        46.00         29.51
    428.6700       27.32           peak           -7.84       19.48        46.00         26.52
    589.6900       26.22           peak           -3.43       22.79        46.00         23.21
    726.4600       24.81           peak           -1.57       23.24        46.00         22.76




                                                                                        Page 19 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190813004-00A

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)

     30.0000        27.77          peak              -7.95    19.82         40.00         20.18
    148.3400        28.47          peak             -12.79    15.68         43.50         27.82
    196.8400        28.14          peak             -13.27    14.87         43.50         28.63
    272.5000        30.87          peak             -11.98    18.89         46.00         27.11
    486.8700        25.93          peak              -6.42    19.51         46.00         26.49
    591.6300        26.44          peak              -3.42    23.02         46.00         22.98




                                                                                         Page 20 of 33


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190813004-00A

 2) 1-25GHz:

                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2402.00      65.80         PK          H     28.10     1.80      0.00     95.70        N/A         N/A
 2402.00      65.42         AV          H     28.10     1.80      0.00     95.32        N/A         N/A
 2402.00      58.13         PK          V     28.10     1.80      0.00     88.03        N/A         N/A
 2402.00      57.79         AV          V     28.10     1.80      0.00     87.69        N/A         N/A
 2390.00      26.18         PK          H     28.08     1.80      0.00     56.06       74.00       17.94
 2390.00      15.91         AV          H     28.08     1.80      0.00     45.79       54.00        8.21
 4804.00      49.59         PK          H     32.91     3.17     37.20     48.47       74.00       25.53
 4804.00      42.13         AV          H     32.91     3.17     37.20     41.01       54.00       12.99
 7206.00      45.00         PK          H     35.74     4.82     37.23     48.33       74.00       25.67
 7206.00      33.16         AV          H     35.74     4.82     37.23     36.49       54.00       17.51
                                         Middle Channel: 2440 MHz
 2440.00      65.94         PK          H     28.18     1.82      0.00     95.94        N/A         N/A
 2440.00      65.49         AV          H     28.18     1.82      0.00     95.49        N/A         N/A
 2440.00      58.66         PK          V     28.18     1.82      0.00     88.66        N/A         N/A
 2440.00      58.32         AV          V     28.18     1.82      0.00     88.32        N/A         N/A
 4880.00      49.76         PK          H     33.06     3.27     37.21     48.88       74.00       25.12
 4880.00      42.33         AV          H     33.06     3.27     37.21     41.45       54.00       12.55
 7320.00      45.35         PK          H     36.03     4.62     37.37     48.63       74.00       25.37
 7320.00      33.29         AV          H     36.03     4.62     37.37     36.57       54.00       17.43
                                          High Channel: 2480 MHz
 2480.00      66.16         PK          H     28.26     1.84      0.00     96.26        N/A         N/A
 2480.00      65.74         AV          H     28.26     1.84      0.00     95.84        N/A         N/A
 2480.00      59.06         PK          V     28.26     1.84      0.00     89.16        N/A         N/A
 2480.00      58.57         AV          V     28.26     1.84      0.00     88.67        N/A         N/A
 2483.50      30.73         PK          H     28.27     1.84      0.00     60.84       74.00       13.16
 2483.50      23.01         AV          H     28.27     1.84      0.00     53.12       54.00        0.88
 4960.00      50.55         PK          H     33.22     3.23     37.25     49.75       74.00       24.25
 4960.00      42.69         AV          H     33.22     3.23     37.25     41.89       54.00       12.11
 7440.00      45.38         PK          H     36.34     4.41     37.52     48.61       74.00       25.39
 7440.00      33.59         AV          H     36.34     4.41     37.52     36.82       54.00       17.18




                                                                                          Page 21 of 33


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190813004-00A

    Worst plots (High Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 22 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190813004-00A

Vertical




     Fundamental
     Test with Band
     Rejection Filter




                                                                     Page 23 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190813004-00A

FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)
Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Test Equipment


Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer            Description            Model
                                                                    Number           Date         Due Date

         R&S            Spectrum Analyzer          FSV40             101474       2019-01-09      2020-01-09

       Unknown             Coaxial Cable         C-SJ00-0010       C0010/04        Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:            26.1 C
         Relative Humidity:               69%
             ATM Pressure:           100.4 kPa
                      Tester:         Lily Xie
                  Test Date:         2019-08-20

    Test Mode: Transmitting
   Test Result: Compliance. Please refer to the following table and plots.

                                                                                                    Page 24 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG190813004-00A


                                                    6 dB Emission
                                       Frequency                     Limit
                         Channel                      Bandwidth
                                         (MHz)                      (MHz)
                                                        (MHz)
                          Low             2402           0.668       ≥0.5
                         Middle           2440           0.676       ≥0.5
                         High             2480           0.684       ≥0.5



                                             Low Channel




                                                                                     Page 25 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)           Report No.: RDG190813004-00A


                                           Middle Channel




                                             High Channel




                                                                             Page 26 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190813004-00A

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-10      2019-12-10
                          Power Sensor
       Unknown            Coaxial Cable        C-SJ00-0010        C0010/04         Each time         N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 27 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190813004-00A

Test Data
     Environmental Conditions

              Temperature:              26.1 C
         Relative Humidity:              69%
             ATM Pressure:           100.4 kPa
                     Tester:            Lily Xie
                  Test Date:        2019-08-20

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.

                                                            Max Peak
                                               Frequency    Conducted      Limit
                               Channel
                                                 (MHz)     Output Power   (dBm)
                                                              (dBm)
                                Low                2402        0.23        30
                               Middle              2440        0.79        30
                               High                2480        0.99        30




                                                                                           Page 28 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190813004-00A

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration     Calibration
    Manufacturer           Description             Model
                                                                  Number             Date          Due Date
         R&S           Spectrum Analyzer           FSV40           101474         2019-01-09      2020-01-09
      Unknown             Coaxial Cable          C-SJ00-0010      C0010/04         Each time          N/A

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:           26.1 C
         Relative Humidity:              69%
             ATM Pressure:           100.4 kPa
                     Tester:         Lily Xie
                  Test Date:        2019-08-20

Test mode: Transmitting

                                                                                                    Page 29 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                Report No.: RDG190813004-00A

Test Result: Compliance. Please refer to following plots.

                                          Band Edge, Left Side




                                         Band Edge, Right Side




                                                                                  Page 30 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190813004-00A

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer            Description             Model
                                                                     Number            Date        Due Date

          R&S             Spectrum Analyzer          FSV40               101474     2019-01-09    2020-01-09

        Unknown             Coaxial Cable          C-SJ00-0010       C0010/04        Each time       N/A


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

                Temperature:            26.1 C
          Relative Humidity:               69%
              ATM Pressure:            100.4 kPa
                       Tester:         Lily Xie
                   Test Date:         2019-08-20

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 31 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190813004-00A

                                                    Power Spectral
                                   Frequency                            Limit
                     Channel                           Density
                                     (MHz)                           (dBm/3kHz)
                                                     (dBm/3kHz)
                       Low            2402              -14.08           ≤8
                      Middle          2440              -13.26           ≤8
                      High            2480              -11.08           ≤8


                                Power Spectral Density, Low Channel




                                                                                        Page 32 of 33


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190813004-00A


                              Power Spectral Density, Middle Channel




                                Power Spectral Density, High Channel




                                  ***** END OF REPORT *****

                                                                                        Page 33 of 33



Document Created: 2019-10-01 10:30:01
Document Modified: 2019-10-01 10:30:01

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC