Test Report

FCC ID: 2ASQ9CL800-01

Test Report

Download: PDF
FCCID_4420118

                                           FCC PART 15.247
                                               TEST REPORT

                                                              For

                    ShenZhen chileaf electronics Co., Ltd
            5#D Skyworth Innovation valley, No.8 ,Tongtou 1st Rd ,ShiYan ,BaoAn, ShenZhen, China



                                        FCC ID: 2ASQ9CL800-01


            Report Type:                                 Product Type:
            Original Report                              Heart Rate Monitor


                  Report Number:           RDG190708002-00B


                      Report Date:         2019-08-07


                                           Jerry Zhang
                     Reviewed By:          EMC Manager

                                           Bay Area Compliance Laboratories Corp. (Dongguan)
                 Test Laboratory:          No.69 Pulongcun, Puxinhu Industry Area,
                                           Tangxia, Dongguan, Guangdong, China
                                           Tel: +86-769-86858888
                                           Fax: +86-769-86858891
                                           www.baclcorp.com.cn




Note: This test report is prepared for the customer shown above and for the device described herein. It may not be duplicated or
used in part without prior written consent from Bay Area Compliance Laboratories Corp. (Dongguan). This report must not be
used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of the Federal
Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk “*”.


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                          Report No.: RDG190708002-00B




                                                       TABLE OF CONTENTS

GENERAL INFORMATION .......................................................................................................................................4
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) .....................................................................................4
 OBJECTIVE ...................................................................................................................................................................4
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................4
 TEST METHODOLOGY ..................................................................................................................................................4
 MEASUREMENT UNCERTAINTY ....................................................................................................................................5
 TEST FACILITY .............................................................................................................................................................5
SYSTEM TEST CONFIGURATION ..........................................................................................................................6
  DESCRIPTION OF TEST CONFIGURATION ......................................................................................................................6
  EQUIPMENT MODIFICATIONS .......................................................................................................................................6
  EUT EXERCISE SOFTWARE ..........................................................................................................................................6
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE............................................................................................9
  APPLICABLE STANDARD ..............................................................................................................................................9
FCC §15.203 - ANTENNA REQUIREMENT...........................................................................................................10
  APPLICABLE STANDARD ............................................................................................................................................10
  ANTENNA INFORMATION AND CONNECTOR CONSTRUCTION.....................................................................................10
FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS .................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  EUT SETUP ................................................................................................................................................................11
  EMI TEST RECEIVER & SPECTRUM ANALYZER SETUP ..............................................................................................12
  TEST PROCEDURE ......................................................................................................................................................12
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST DATA ................................................................................................................................................................13
FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH .............................................................................................19
  APPLICABLE STANDARD ............................................................................................................................................19
  TEST PROCEDURE ......................................................................................................................................................19
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................19
  TEST DATA ................................................................................................................................................................19
FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER ......................................................22
  APPLICABLE STANDARD ............................................................................................................................................22
  TEST PROCEDURE ......................................................................................................................................................22
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................22
  TEST DATA ................................................................................................................................................................23
FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE .......................................................24
  APPLICABLE STANDARD ............................................................................................................................................24
  TEST PROCEDURE ......................................................................................................................................................24
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................24
  TEST DATA ................................................................................................................................................................24
FCC §15.247(e) - POWER SPECTRAL DENSITY .................................................................................................26
  APPLICABLE STANDARD ............................................................................................................................................26
  TEST PROCEDURE ......................................................................................................................................................26
                                                                                                                                                            Page 2 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                                                                       Report No.: RDG190708002-00B


 TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................26
 TEST DATA ................................................................................................................................................................26




                                                                                                                                                          Page 3 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190708002-00B

GENERAL INFORMATION
Product Description for Equipment under Test (EUT)

                    EUT Name:         Heart Rate Monitor
                    EUT Model:        CL800
                Multiple Model:       CL801 ,CL802 ,CL803 ,CL804 ,CL805
           Operation Frequency:       2402-2480 MHz
     Maximum peak Output Power
                                      0.38 dBm
                   (Conducted):
              Modulation Type:        GFSK
            Rated Input Voltage:      DC 3V from battery
            External Dimension:       60(mm)*35(mm)*13(mm)
                 Serial Number:       190708002
            EUT Received Date:        2019-07-11

Notes: Model CL800was selected for fully testing, the detailed information about the difference among
CL801 ,CL802 ,CL803 ,CL804 ,CL805 can be referred to the declaration letter which was stated and guaranteed by
the manufacturer.


Objective
This report is prepared on behalf of ShenZhen chileaf electronics Co., Ltd in accordance with Part 2,
Subpart J, Part 15, Subparts A and C of the Federal Communications Commission’s rules

The tests were performed in order to determine the compliance of the EUT with FCC Rules Part 15-
Subpart C, section 15.203, 15.205, 15.209, 15.247 rules.


Related Submittal(s)/Grant(s)
. No Related Submittal(s)/Grant(s)


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices and KDB 558074 D01
DTS Meas Guidance v05r02.

All emissions measurement was performed and Bay Area Compliance Laboratories Corp. (Dongguan).




                                                                                                   Page 4 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190708002-00B

Measurement Uncertainty
            Parameter                                      Measurement Uncertainty
    Occupied Channel Bandwidth                                     ±5 %
    RF output power, conducted                                    ±0.61dB
  Power Spectral Density, conducted                               ±0.61 dB
                                          30M~200MHz: 4.55 dB,200M~1GHz: 5.92 dB,1G~6GHz: 4.98 dB,
    Unwanted Emissions, radiated
                                            6G~18GHz: 5.89 dB,18G~26.5G:5.47 dB,26.5G~40G:5.63 dB
   Unwanted Emissions, conducted                                    ±1.5 dB
           Temperature                                                ±1℃
             Humidity                                                 ±5%
   DC and low frequency voltages                                     ±0.4%
            Duty Cycle                                                 1%
 AC Power Lines Conducted Emission                        3.12 dB (150 kHz to 30 MHz)


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Dongguan) to collect test data is located
on the No.69 Pulongcun, Puxinhu Industry Area, Tangxia, Dongguan, Guangdong, China.

The lab has been recognized as the FCC accredited lab under the KDB 974614 D01 and is listed in the
FCC Public Access Link (PAL) database, FCC Registration No. : 897218, the FCC Designation No. :
CN1220.

The lab has been recognized by Innovation, Science and Economic Development Canada to test to
Canadian radio equipment requirements, the CAB identifier: CN0022.




                                                                                             Page 5 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190708002-00B

SYSTEM TEST CONFIGURATION
Description of Test Configuration
The system was configured for testing in engineering mode.
For Bluetooth LE mode, 40 channels are provided for testing:

                                      Frequency                                       Frequency
                Channel                                       Channel
                                        (MHz)                                           (MHz)
                   0                     2402                   20                       2442
                   1                     2404                   …                         …
                   …                      …                     …                         …
                   …                     …                      …                        …
                    ..                   …                      38                      2478
                   19                   2440                    39                      2480

EUT was tested with channel 0, 19 and 39.


Equipment Modifications
No modification was made to the EUT tested.


EUT Exercise Software
The software:' RTLBTAPP ' was used during test, which was provided by manufacturer. The maximum
power level was configured by the software as below table:

                                               Frequency                Power level
                           Channel
                                                 (MHz)                    Setting
                            Low                   2402                       9
                           Middle                 2440                       9
                           High                   2480                       9

The duty cycle as below:

                               Ton                  Ton+off             Duty Cycle
                              (ms)                  (ms)                   (%)
                              0.232                 0.622                 37.30




                                                                                                  Page 6 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190708002-00B




Block Diagram of Test Setup




                                                                      Page 7 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190708002-00B


SUMMARY OF TEST RESULTS

               FCC Rules                            Description of Test                 Result

       FCC §15.247 (i) & §1.1310 &
                                                          RF Exposure                 Compliance
                §2.1093
                §15.203                            Antenna Requirement                Compliance

               §15.207 (a)                    AC Line Conducted Emissions           Not Applicable
            §15.205, §15.209,
                                                    Spurious Emissions                Compliance
               §15.247(d)
             §15.247 (a)(2)                              6 dB Bandwidth               Compliance

              §15.247(b)(3)                 Maximum Conducted Output Power            Compliance

               §15.247(d)              100 kHz Bandwidth of Frequency Band Edge       Compliance

               §15.247(e)                         Power Spectral Density              Compliance


    Not Applicable: the device was powered by battery.




                                                                                                 Page 8 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                           Report No.: RDG190708002-00B

FCC §15.247 (i) & §1.1310 & §2.1093- RF EXPOSURE
Applicable Standard
According to§15.247(i) and §1.1310, systems operating under the provisions of this section shall be
operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess of
the Commission’s guideline.

According to KDB447498 D01 General RF Exposure Guidance v06:

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances ≤ 50
mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] · [√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where
        • f(GHz) is the RF channel transmit frequency in GHz
        • Power and distance are rounded to the nearest mW and mm before calculation
        • The result is rounded to one decimal place for comparison
        • 3.0 and 7.5 are referred to as the numeric thresholds in the step 2 below

The test exclusions are applicable only when the minimum test separation distance is ≤ 50 mm and for
transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
mm, a distance of 5 mm according to 5) in section 4.1 is applied to determine SAR test exclusion.


Measurement Result

The max conducted power including tune-up tolerance is 1 dBm (1.26 mW).
[(max. power of channel, mW)/(min. test separation distance, mm)][√f(GHz)]
=1.26/5*(√2.480) = 0.4< 3.0

So the stand-alone SAR evaluation is not necessary.




                                                                                                 Page 9 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                             Report No.: RDG190708002-00B

FCC §15.203 - ANTENNA REQUIREMENT
Applicable Standard
According to § 15.203, an intentional radiator shall be designed to ensure that no antenna other than that
furnished by the responsible party shall be used with the device. The use of a permanently attached
antenna or of an antenna that uses a unique coupling to the intentional radiator shall be considered
sufficient to comply with the provisions of this section. The manufacturer may design the unit so that a
broken antenna can be replaced by the user, but the user of a standard antenna jack or electrical connector
is prohibited. The structure and application of the EUT were analyzed to determine compliance with
section §15.203 of the rules. §15.203 state that the subject device must meet the following criteria:

a. Antenna must be permanently attached to the unit.
b. Antenna must use a unique type of connector to attach to the EUT.
c. Unit must be professionally installed, and installer shall be responsible for verifying that the correct
   antenna is employed with the unit.


Antenna Information And Connector Construction
The EUT has one internal antenna arrangement, and the antenna gain is -1.0 dBi, fulfill the requirement of
this section. Please refer to the EUT photos.

Result: Compliance.




                                                                                                 Page 10 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                          Report No.: RDG190708002-00B

FCC §15.209, §15.205, §15.247(d) - SPURIOUS EMISSIONS
Applicable Standard
FCC §15.247 (d); §15.209; §15.205

EUT Setup
Below 1GHz:




Above 1GHz:




The radiated emission Below 1GHz tests were performed in the 10 meters chamber, above 1GHz tests
were performed in the 3 meters chamber B, using the setup accordance with the ANSI C63.10-2013. The
specification used was the FCC 15.209, and FCC 15.247 limits.

The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the
middle.

The spacing between the peripherals was 10 cm.




                                                                                              Page 11 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                         Report No.: RDG190708002-00B

EMI Test Receiver & Spectrum Analyzer Setup

The system was investigated from 30 MHz to 25 GHz.

During the radiated emission test, the EMI test receiver & Spectrum Analyzer Setup were set with the
following configurations:

30MHz-1000MHz:

                    Measurement             RBW            Video B/W       IF B/W
                        QP                 120 kHz          300 kHz        120kHz

1GHz- 25GHz:

                       Measurement            Duty cycle       RBW         Video B/W
                           PK                    Any           1MHz          3 MHz
                                                >98%           1MHz          10 Hz
                            AV
                                                <98%           1MHz            1/T

Note: T is minimum transmission duration

If the maximized peak measured value complies with under the QP/Average limit more than 6dB, then it is
unnecessary to perform an QP/Average measurement.


Test Procedure

Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all
installation combinations.

Data was recorded in Quasi-peak detection mode for frequency range of 30 MHz-1 GHz, peak and
Average detection modes for frequencies above 1 GHz.


Corrected Amplitude & Margin Calculation

The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Meter Reading. The basic equation is as follows:

        Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

        Margin = Limit –Corrected Amplitude




                                                                                             Page 12 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                               Report No.: RDG190708002-00B

Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
    Manufacturer           Description                Model
                                                                     Number            Date         Due Date
         R&S           EMI Test Receiver           ESCI               100035        2018-08-03     2019-08-03
        Farad            Test Software            EZ-EMC             V1.1.4.2          N/A            N/A
    Sunol Sciences          Antenna                 JB3             A060611-2       2017-08-25     2020-08-25
       Unknown           Coaxial Cable           C-NJNJ-50          C-1000-01       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0400-02       2018-09-05     2019-09-05
       Unknown           Coaxial Cable           C-NJNJ-50          C-0530-01       2018-09-24     2019-09-24
          HP               Amplifier               8447F           2443A01912       2018-09-05     2019-09-05
        Agilent        Spectrum Analyzer          E4440A           SG43360054       2019-05-09     2020-05-09
    ETS-Lindgren         Horn Antenna               3115            000 527 35      2018-10-12     2021-10-12
      Ducommun                                                     1007726-01
                          Horn Antenna          ARH-4223-02                         2016-11-18     2019-11-18
     Technolagies                                                      1304
       Unknown            Coaxial Cable          C-SJSJ-50          C-0800-01       2018-09-05     2019-09-05
       Unknown            Coaxial Cable        C-2.4J2.4J-50        C-0700-02       2019-06-27     2020-06-27
                                              AFS42-00101800-
        MITEQ               Amplifier                                 2001271       2018-09-05     2019-09-05
                                                  25-S-42
       Quinstar             Amplifier        QLW-18405536-JO       15964001001      2019-06-27     2020-06-27
                                             OBSF-2400-2483.5-
     E-Microwave        Band-stop Filters                          OE01601525       2019-06-16     2020-06-16
                                                     S
     Micro-tronics       High Pass Filter       HPM50111             S/N-G217       2019-06-16     2020-06-16

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data

     Environmental Conditions

              Temperature:                 25.6oC
         Relative Humidity:                 48%
            ATM Pressure:                 100.3kPa
                     Tester:              Neil Liao
                  Test Date:             2019-07-17

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots.




                                                                                                    Page 13 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190708002-00B

1) 30MHz-1GHz (High Channel was the worst):
Horizontal:




                  Receiver                     Correction     Cord.
   Frequency                                                               Limit        Margin
                  Reading        Detector       Factor        Amp.
     (MHz)                                                               (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)      (dBuV/m)
     32.9100       29.12           peak           -9.36       19.76        40.00         20.24
     55.2200       35.34           peak          -20.03       15.31        40.00         24.69
    116.3300       33.45           peak          -16.33       17.12        43.50         26.38
    199.7500       29.26           peak          -12.79       16.47        43.50         27.03
    268.6200       29.53           peak          -12.12       17.41        46.00         28.59
    459.7100       27.74           peak           -7.14       20.60        46.00         25.40




                                                                                        Page 14 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190708002-00B

Vertical:




                  Receiver                     Correction      Cord.
   Frequency                                                                Limit        Margin
                  Reading        Detector       Factor         Amp.
     (MHz)                                                                (dBuV/m)        (dB)
                  (dBuV)                        (dB/m)       (dBuV/m)
     31.9400        31.69          peak              -8.88    22.81         40.00         17.19
    110.5100        33.33          peak             -16.46    16.87         43.50         26.63
    163.8600        34.07          peak             -12.86    21.21         43.50         22.29
    291.9000        29.44          peak             -11.29    18.15         46.00         27.85
    379.2000        28.20          peak              -8.60    19.60         46.00         26.40
    467.4700        31.78          peak              -6.96    24.82         46.00         21.18




                                                                                         Page 15 of 28


  Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190708002-00B

 2) 1-25GHz:
                  Receiver             Rx Antenna      Cable Amplifier   Corrected
Frequency                                                                              Limit      Margin
            Reading    Detector       Polar Factor       loss    Gain    Amplitude
  (MHz)                                                                              (dBμV/m)      (dB)
            (dBμV) (PK/QP/AV)         (H/V) (dB/m)      (dB)     (dB)    (dBμV/m)
                                          Low Channel: 2402 MHz
 2390.00      26.98         PK          V     28.08     1.80      0.00     56.86        74.00      17.14
 2390.00      14.65         AV          V     28.08     1.80      0.00     44.53        54.00       9.47
 4804.00      59.78         PK          V     32.91     3.17     37.20     58.66        74.00      15.34
 4804.00      50.05         AV          V     32.91     3.17     37.20     48.93        54.00      5.07
 7206.00      50.16         PK          V     35.74     4.82     37.23     53.49        74.00      20.51
 7206.00      46.27         AV          V     35.74     4.82     37.23     49.60        54.00      4.40
                                         Middle Channel: 2440 MHz
 4880.00      58.29         PK          V     33.06     3.27     37.21     57.41        74.00      16.59
 4880.00      47.80         AV          V     33.06     3.27     37.21     46.92        54.00      7.08
 7320.00      53.30         PK          V     36.03     4.62     37.37     56.58        74.00      17.42
 7320.00      48.21         AV          V     36.03     4.62     37.37     51.49        54.00      2.51
                                          High Channel: 2480 MHz
 2483.50      26.98         PK          V     28.27     1.84      0.00     57.09        74.00      16.91
 2483.50      14.33         AV          V     28.27     1.84      0.00     44.44        54.00       9.56
 4960.00      56.28         PK          V     33.22     3.23     37.25     55.48        74.00      18.52
 4960.00      50.45         AV          V     33.22     3.23     37.25     49.65        54.00      4.35
 7440.00      56.32         PK          V     36.34     4.41     37.52     59.55        74.00      14.45
 7440.00      49.65         AV          V     36.34     4.41     37.52     52.88        54.00      1.12




                                                                                          Page 16 of 28


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190708002-00B

    Worst plots (High Channel)
    Horizontal


Fundamental
Test with Band
Rejection Filter




                                                                          Page 17 of 28


     Bay Area Compliance Laboratories Corp. (Dongguan)   Report No.: RDG190708002-00B

    Vertical




Fundamental
Test with Band
Rejection Filter




                                                                          Page 18 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190708002-00B

FCC §15.247(a) (2) –6 dB EMISSION BANDWIDTH
Applicable Standard
According to FCC §15.247(a) (2)

Systems using digital modulation techniques may operate in the 902–928 MHz, 2400–2483.5 MHz, and
5725–5850 MHz bands. The minimum 6 dB bandwidth shall be at least 500 kHz.


Test Procedure

a) Set RBW = 100 kHz.
b) Set the video bandwidth (VBW) ≥ 3×RBW.
c) Detector = Peak.
d) Trace mode = max hold.
e) Sweep = auto couple.
f) Allow the trace to stabilize.
g) Measure the maximum width of the emission that is constrained by the frequencies associated with the
   two outermost amplitude points (upper and lower frequencies) that are attenuated by 6 dB relative to the
   maximum level measured in the fundamental emission.


                                 EUT                                 Signal Analyzer



Test Equipment List and Details

                                                                     Serial       Calibration    Calibration
    Manufacturer            Description             Model
                                                                    Number           Date         Due Date

       Unknown             Coaxial Cable        C-SJ00-0010        C0012/01        Each time         N/A

         R&S            Spectrum Analyzer           FSP 38           100478       2018-12-10      2019-12-10


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                 29.4C
         Relative Humidity:                60%
            ATM Pressure:               100.6 kPa
                     Tester:             Lily Xie
                  Test Date:           2019-07-11

    Test Mode: Transmitting
   Test Result: Compliance. Please refer to the following table and plots.

                                                                                                    Page 19 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                   Report No.: RDG190708002-00B


                                                    6 dB Emission
                                       Frequency                     Limit
                         Channel                      Bandwidth
                                         (MHz)                      (MHz)
                                                        (MHz)
                          Low             2402           0.676       ≥0.5
                         Middle           2440           0.672       ≥0.5
                         High             2480           0.676       ≥0.5



                                             Low Channel




                                                                                     Page 20 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)           Report No.: RDG190708002-00B


                                           Middle Channel




                                             High Channel




                                                                             Page 21 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190708002-00B

FCC §15.247(b) (3) - MAXIMUM PEAK CONDUCTED OUTPUT POWER
Applicable Standard
According to FCC §15.247(b) (3), for systems using digital modulation in the 902-928 MHz, 2400-2483.5
MHz, and 5725-5850 MHz bands: 1 Watt. As an alternative to a peak power measurement, compliance
with the one Watt limit can be based on a measurement of the maximum conducted output power.
Maximum Conducted Output Power is defined as the total transmit power delivered to all antennas and
antenna elements averaged across all symbols in the signaling alphabet when the transmitter is operating at
its maximum power control level. Power must be summed across all antennas and antenna elements. The
average must not include any time intervals during which the transmitter is off or is transmitting at a
reduced power level. If multiple modes of operation are possible (e.g., alternative modulation methods),
the maximum conducted output power is the highest total transmit power occurring in any mode.


Test Procedure
1. Place the EUT on a bench and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the antenna port to test
   equipment.
3. Add a correction factor to the display.
4.

                                                                      USB Wideband
                                                                       Power Sensor
                                EUT



Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description            Model
                                                                  Number             Date         Due Date

       Unknown            Coaxial Cable        C-SJ00-0010        C0012/01         Each time         N/A
                         USB Wideband
        Agilent                                 U2022XA         MY5417006         2018-12-10      2019-12-10
                          Power Sensor

  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).




                                                                                                    Page 22 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                        Report No.: RDG190708002-00B


Test Data
     Environmental Conditions

              Temperature:                29.4C
         Relative Humidity:                  60%
            ATM Pressure:                 100.6 kPa
                     Tester:               Lily Xie
                  Test Date:             2019-07-11


Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table.


                                                           Max Peak
                                              Frequency    Conducted      Limit
                               Channel
                                                (MHz)     Output Power   (dBm)
                                                             (dBm)
                                Low             2402          0.38        30
                               Middle           2440          0.13        30
                               High             2480          -0.02       30




                                                                                          Page 23 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                              Report No.: RDG190708002-00B

FCC §15.247(d) – 100 kHz BANDWIDTH OF FREQUENCY BAND EDGE
Applicable Standard
According to FCC§15.247(d):In any 100 kHz bandwidth outside the frequency band in which the spread
spectrum or digitally modulated intentional radiator is operating, the radio frequency power that is
produced by the intentional radiator shall be at least 20 dB below that in the 100 kHz bandwidth within the
band that contains the highest level of the desired power, based on either an RF conducted or a radiated
measurement, provided the transmitter demonstrates compliance with the peak conducted power limits. If
the transmitter complies with the conducted power limits based on the use of RMS averaging over a time
interval, as permitted under paragraph (b)(3) of this section, the attenuation required under this paragraph
shall be 30 dB instead of 20 dB. Attenuation below the general limits specified in §15.209(a) is not
required. In addition, radiated emissions which fall in the restricted bands, as defined in §15.205(a), must
also comply with the radiated emission limits specified in §15.209(a) (see §15.205(c)).


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT without connection to measurement instrument. Turn on the EUT and connect its
   antenna terminal to measurement instrument via a low loss cable. Then set it to any one measured
   frequency within its operating range, and make sure the instrument is operated in its linear range.
3. Set RBW to 100 kHz and VBW of spectrum analyzer to 300 kHz with a convenient frequency span
   including 100 kHz bandwidth from band edge.
4. Measure the highest amplitude appearing on spectral display and set it as a reference level. Plot the
   graph with marking the highest point and edge frequency.
5. Repeat above procedures until all measured frequencies were complete.


Test Equipment List and Details

                                                                   Serial         Calibration    Calibration
    Manufacturer           Description             Model
                                                                  Number             Date         Due Date

       Unknown            Coaxial Cable        C-SJ00-0010        C0012/01         Each time         N/A

         R&S            Spectrum Analyzer          FSP 38          100478         2018-12-10      2019-12-10


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

              Temperature:                29.4C
         Relative Humidity:               60%
            ATM Pressure:              100.6 kPa
                     Tester:            Lily Xie
                  Test Date:          2019-07-11
Test mode: Transmitting
Test Result: Compliance. Please refer to following plots.
                                                                                                    Page 24 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)               Report No.: RDG190708002-00B


                                         Band Edge, Left Side




                                        Band Edge, Right Side




                                                                                 Page 25 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                                 Report No.: RDG190708002-00B

FCC §15.247(e) - POWER SPECTRAL DENSITY
Applicable Standard
According to FCC§15.247(e):For digitally modulated systems, the power spectral density conducted from
the intentional radiator to the antenna shall not be greater than 8 dBm in any 3 kHz band during any time
interval of continuous transmission. This power spectral density shall be determined in accordance with
the provisions of paragraph (b) of this section. The same method of determining the conducted output
power shall be used to determine the power spectral density.


Test Procedure
1. Check the calibration of the measuring instrument using either an internal calibrator or a known signal
   from an external generator.
2. Position the EUT was set without connection to measurement instrument. Turn on the EUT and
   connect its antenna terminal to measurement instrument via a low loss cable. Then set it to any one
   measured frequency within its operating range, and make sure the instrument is operated in its linear
   range.
3. Set the RBW = 3 kHz, VBW = 10 kHz, Set the span to 1.5 times the DTS bandwidth.
4. Use the peak marker function to determine the maximum amplitude level.


Test Equipment List and Details

                                                                      Serial        Calibration   Calibration
     Manufacturer            Description              Model
                                                                     Number            Date        Due Date

        Unknown             Coaxial Cable        C-SJ00-0010         C0012/01        Each time       N/A

          R&S             Spectrum Analyzer         FSP 38               100478     2018-12-10    2019-12-10


  * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Dongguan) attests that all calibrations
  have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

               Temperature:                 29.4C
         Relative Humidity:                  60%
            ATM Pressure:                 100.6 kPa
                     Tester:               Lily Xie
                  Test Date:             2019-07-11

Test Mode: Transmitting

Test Result: Compliance. Please refer to the following table and plots




                                                                                                    Page 26 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                      Report No.: RDG190708002-00B


                                                    Power Spectral
                                   Frequency                             Limit
                    Channel                            Density
                                     (MHz)                            (dBm/3kHz)
                                                     (dBm/3kHz)
                      Low             2402              -13.85            ≤8
                     Middle           2440              -15.60            ≤8
                     High             2480              -13.29            ≤8


                                Power Spectral Density, Low Channel




                                                                                        Page 27 of 28


Bay Area Compliance Laboratories Corp. (Dongguan)                       Report No.: RDG190708002-00B

                               Power Spectral Density, Middle Channel




                                Power Spectral Density, High Channel




                                  ***** END OF REPORT *****


                                                                                         Page 28 of 28



Document Created: 2019-08-30 12:11:55
Document Modified: 2019-08-30 12:11:55

© 2024 FCC.report