test report

FCC ID: 2ASPF-D8

Test Report

Download: PDF
FCCID_4235181

  Report No.:           FCC1903035
  File reference No.:   2019-03-27

  Applicant:            RUII Industrial(HK)Co.,Ltd


  Product:              Wireless Charger

  Model No.:            D8

  Trademark:            N/A


  Test Standards:       FCC Part 15 Subpart C




                        It is herewith confirmed and found to comply with the
  Test result:
                        requirements set up by ANSI C63.4&FCC Part 15 Subpart C for
                        the evaluation of electromagnetic compatibility


  Approved By



  Jack Chung

  Manager

  Dated:                March 27, 2019

  Results appearing herein relate only to the sample tested
  The technical reports is issued errors and omissions exempt and is subject to
  withdrawal at

       SHENZHEN TIMEWAY TESTING LABORATORIES
Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West,
Tong Le Village, Nanshan District, Shenzhen, China
      Tel (755) 83448688, Fax (755) 83442996, E-Mail:info@timeway-lab.com


 Report No: FCC1903035                                                                                                        Page 2 of 33
 Date: 2019-03-27



         Special Statement:
              The testing quality ability of our laboratory meet with "Quality Law of People's Republic
         of China" Clause 19.
              The testing quality system of our laboratory meets with ISO/IEC-17025 requirements,
         which is approved by CNAS. This approval result is accepted by MRA of APLAC.

                 Our test facility is recognized, certified, or accredited by the following organizations:

              CNAS-LAB Code: L2292
              The EMC Laboratory has been assessed and in compliance with CNAS-CL01
         accreditation criteria for testing Laboratories (identical to ISO/IEC 17025:1999 General
         Requirements) for the Competence of testing Laboratories.

             FCC-Registration No.: 744189
             The EMC Laboratory has been registered and fully described in a report filed with the
         (FCC) Federal Communications commission. The acceptance letter from the FCC is
         maintained in our files. Registration No.:744189.




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 3 of 33
 Date: 2019-03-27


         Test Report Conclusion
         Content
1.0      General Details ……………………..…………………………..……………………………..…                                                                            4
1.1      Test Lab Details…………………………………………………………..………………….……                                                                              4
1.2      Applicant Details………………………………………………………….……………….……..                                                                             4
1.3      Description of EUT ……………………………………………………………..………….……                                                                             4
1.4      Submitted Sample………………………..……………………………………..………………..                                                                             4
1.5      Test Duration…………………………………….…………………………………..…….……...                                                                             5
1.6      Test Uncertainty……………………………………….……………………………...…………...                                                                           5
1.7      Test By…………………………………………………………………………………………….                                                                                     5
2.0      List of Measurement Equipment…………………………………………………………….…                                                                          6
3.0      Technical Details…………………………………………………………………………………                                                                                7
3.1      Summary of Test Results………………………………………………………………………….                                                                            7
3.2      Test Standards……………………………………………………………………………………..                                                                                7
4.0      EUT Modification………………………………………………………………………………...                                                                               7
5.0      Power Line Conducted Emission Test…………………………………………………………….                                                                      8
5.1      Schematics of the Test…………………………………………………………………………….                                                                            8
5.2      Test Method and Test Procedure………………………………………………………………….                                                                        8
5.3      Configuration of the EUT…………………………………………………………………………                                                                            8
5.4      EUT Operating Condition…………………………………………………………………………                                                                             9
5.5      Conducted Emission Limit………………………………………………………………………..                                                                           9
5.6      Test Result………………………………………………………………………………………...                                                                                 9
6.0      Radiated Emission test…………………………………………………………………………..                                                                            14
6.1      Test Method and Test Procedure………………………………………………………………….                                                                        14
6.2      Configuration of the EUT…………………………………………………………………………                                                                            15
6.3      EUT Operation Condition…………………………………………………………………………                                                                             15
6.4      Radiated Emission Limit………………………………………………………………………….                                                                            15
6.5      Test Result………………………………………………………………………………………...                                                                                 16
7.0      20dB Bandwidth Test……………………………………………………………………………..                                                                              23
8.0      Antenna Requirement……………………………………………………..……………………...                                                                            25
9.0      FCC Label………………………………………………………………………………………..                                                                                    26
10.0     Photo of Testing………………………….…………………………….…………………………                                                                               27




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 4 of 33
 Date: 2019-03-27


1.0    General Details

1.1    Test Lab Details
       Name :         SHENZHEN TIMEWAY TESTING LABORATORIES.
       Address:       Zone C, 1st Floor, Block B, Jun Xiang Da Building, Zhongshan Park Road West, Tong Le
                      Village, Nanshan District, Shenzhen, China
       Telephone:     +86 755 83448688
       Fax:           +86 755 83442996
       Site on File with the Federal Communications Commission – United Sates
       Registration Number: 744189
       For 3m Anechoic Chamber

1.2    Applicant Details
       Applicant:    RUII Industrial(HK)Co.,Ltd
       Address:      Unit B,4th, East Building,Lushi Industrial Building, Baoan district, Shenzhen
       Telephone:    13828862954
       Fax:          075582592119

1.3    Description of EUT
       Product:                             Wireless Charger
       Manufacturer:                        RUII Industrial(HK)Co.,Ltd
       Address:                             Unit B,4th, East Building,Lushi Industrial Building, Baoan district, Shenzhen
       Brand Name:                          N/A
       Model Number:                        D8
       Additional Model Name                N/A
       Additional Trade Name                N/A
       Rating:                              Input: DC5V, 2 A (Normal charge) or DC9V, 1.67A (fast charge);
                                            Built-in 3.7V, 300mAh Li-ion battery
       Operation Frequency:                 See below table


                Frequency                           Frequency                          Frequency                           Frequency
Channel                            Channel                             Channel                            Channel
                   (MHz)                              (MHz)                              (MHz)                                (MHz)

      01           0.1115              06              0.140              11              0.165              16               0.190

      02            0.120              07              0.145              12              0.170              17               0.195

      03            0.125              08              0.150              13              0.175              18               0.200

      04            0.130              09              0.155              14              0.180              19               0.205


The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 5 of 33
 Date: 2019-03-27



      05            0.135              10              0.160              15              0.185

       Teas channel                     Frequency (MHz)

            CH13                            0.175 MHz




       Modulation Type:                     MSK
       Antenna Designation                  Inductive Loop Antenna with Gain 0dBi

1.4    Submitted Sample
       1 Samples

1.5    Test Duration
       2019-03-06 to 2019-03-26

1.6    Test Uncertainty
       Conducted Emissions Uncertainty =3.6dB
       Radiated Emissions below 9kHz-30MHz Uncertainty =4.3dB
       Radiated Emissions below 30MHz-1GHz Uncertainty =4.7dB
       Radiated Emissions above 1GHz Uncertainty =6.0dB
       Conducted Power Uncertainty =6.0dB
       Occupied Channel Bandwidth Uncertainty =5%

1.7    Test Engineer

       The sample tested by

                                         Print Name: Terry Tang




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


   Report No: FCC1903035                                                                                                        Page 6 of 33
   Date: 2019-03-27



2.0 Test Equipment
 Instrument Type               Manufacturer                   Model                        Serial No.                  Date of Cal.          Due Date
ESPI Test Receiver                   R&S                      ESPI 3                         100379                    2018-06-22           2019-06-21
 Ultra Broadband                     R&S
                                                              HL562                          100157                    2018-06-18           2019-06-17
       ANT
   Loop Antenna                     EMCO                       6507                        00078608                    2018-06-25           2019-06-24
     Spectrum                        R&S                     FSIQ26                          100292                    2018-06-22           2019-06-21
   Horn Antenna                    A-INFO               LB-180400-KF                      J211060660                   2018-06-25           2019-06-24
   Horn Antenna                      R&S                 BBHA 9120D                        9120D-631                   2018-08-24           2019-08-23
   Bilog Antenna                Schwarebeck                VULB9163                         9163/340                   2018-07-04           2019-07-03
  9*6*6 Anechoic                        --                       --                            N/A                     2018-02-07           2021-02-06
     Spectrum                    HP/Agilent               ESA-L1500A                     US37451154                    2018-06-22           2019-06-21
     Spectrum                    HP/Agilent                  E4407B                      MY50441392                    2018-03-27           2019-03-26
     Spectrum                          RS                       FSP                      1164.4391.38                  2019-01-18           2020-01-17
                                                         ZT26-NJ-NJ-8
     RF Cable                      Zhengdi                                                       --                    2018-05-24           2019-05-23
                                                            M/FA
     RF Cable                      Zhengdi                      7m                               --                    2018-03-17           2019-03-16
     RF Switch                        EM                    EMSW18                           060391                    2018-06-22           2019-06-21
   Pre-Amplifier                Schwarebeck                 BBV9743                            #218                    2018-06-22           2019-06-21
   Pre-Amplifier                 HP/Agilent                   8449B                       3008A00160                   2018-08-05           2019-08-04
DC Power Supply                    Jingtong                  JT12098                       WYK-305                     2018.08.20           2019-08-19
        LISN                   SCHAFFNER                     NNB42                            00012                    2019-01-08           2020-01-07




  The report refers only to the sample tested and does not apply to the bulk.
  This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
  may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
  show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
  others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
  discussion of correspondence with any third party concerning the contents of the report.
  In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
  adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 7 of 33
 Date: 2019-03-27



3.0       Technical Details

3.1       Summary of test results
                      The EUT has been tested according to the following specifications:


                                      Standard                                    Test Type            Result                  Notes
                        FCC Part 15, Paragraph 15.203                              Antenna              PASS                Compliant
                                                                                 requirements
                        FCC Part 15, Paragraph 15.207                            Conducted              PASS                Compliant
                                                                                Emission Test
                                                                                   General
                    FCC Part 15, Paragraph 15.209 (a) (f)                                               PASS                Compliant
                                                                                 Requirement
                        FCC Part 15, Paragraph 15.215                               20dB                PASS                Compliant
                                                                                  Bandwidth
                                                                                   Testing


3.2       Test Standards
          FCC Part 15 Subpart C , ANSI C63.4 :2014 and ANSI C63.10 :2013

4.0       EUT Modification
          No modification by SHENZHEN TIMEWAY TESTING LABORATORIES




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 8 of 33
 Date: 2019-03-27



5.       Power Line Conducted Emission Test

5.1      Schematics of the test
                                         Test Receiver




      AC Mains                               L.I.S.N                                   EUT                              Load


                                   EUT: Equipment Under Test
5.2      Test Method and test Procedure
         The EUT was tested according to ANSI C63.10-2013.The Frequency spectrum From 0.15MHz to
         30MHz was investigated. The LISN used was 50ohm/50uH as specified by section 5.1 of ANSI C63.10
         –2013.

         Block diagram of Test setup

                                                     EUT                      Cable
                                                                                                           Receiver



                       800mm
                                                                                L.S.I.N
                                                                                                          AC



5.3      Configuration of The EUT
         The EUT was configured according to ANSI C63.10-2013. All interface ports were connected to the
         appropriate peripherals. All peripherals and cables are listed below.
A.       EUT
         Device                              Manufacturer                                             Model                     FCC ID
     Wireless Charger                      RUII Industrial(HK)Co.,Ltd                                   D8                    2ASPF-D8


B.       Internal Device
        Device                                      Manufacturer                                       Model                FCC ID/DOC
          N/A
C.       Peripherals
         Device                   Manufacturer                         Model                                        Rating


The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 9 of 33
 Date: 2019-03-27



      Power Supply                      h.TV                   S012BES0500200                     Input:100-240V~, 50/60Hz,0.5A;
                                                                                                         Output: DC5V, 2A
                                        GW                      GW-TCQC3-A1                      Input:100-240V~, 50/60Hz,0.5A;
                                                                                                 Output: DC5V, 3A or DC9V, 2A or
                                                                                                          DC12V, 1.5A
5.4      EUT Operating Condition
         Operating condition is according to ANSI C63.10 -2013.
A        Setup the EUT and simulators as shown on follow
B        Enable AF signal and confirm EUT active to normal condition

5.5      Power line conducted Emission Limit according to Paragraph 15.207
        Frequency                      Class A Limits (dBμV)                                   Class B      Limits (dBμV)
          (MHz)               Quasi-peak Level              Average Level             Quasi-peak Level               Average Level
    0.15 ~ 0.50                       79.0                        66.0                    66.0~56.0*                   56.0~46.0*
    0.50 ~ 5.00                       73.0                        60.0                         56.0                         46.0
    5.00 ~ 30.00                      73.0                        60.0                         60.0                         50.0
         Notes:        1. *Decreasing linearly with logarithm of frequency.
                       2. The tighter limit shall apply at the transition frequencies

5.6      Test Results
         The frequency spectrum from 0.15MHz to 30MHz was investigated. All reading are
         quasi-peak values with a resolution bandwidth of 9kHz. (The average detector is
         necessary when the Quasi-peak emission level beyond the average Limit.)




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 10 of 33
 Date: 2019-03-27



A:         Conducted Emission on Live Terminal (150kHz to 30MHz)
           EUT Operating Environment
           Temperature: 26℃          Humidity: 65%RH        Atmospheric Pressure: 101 KPa
           EUT set Condition: Keep Transmitting (Normal Charge)
           Equipment Level: Class B
           Results: PASS
           Please refer to following diagram for individual




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 11 of 33
 Date: 2019-03-27



B:         Conducted Emission on Neutral Terminal (150kHz to 30MHz)
           EUT Operating Environment
           Temperature: 26℃          Humidity: 65%RH        Atmospheric Pressure: 101 KPa
           EUT set Condition: Keep Transmitting (Normal Charge)
           Equipment Level: Class B
           Results: Pass
           Please refer to following diagram for individual




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 12 of 33
 Date: 2019-03-27



C:         Conducted Emission on Live Terminal (150kHz to 30MHz)
           EUT Operating Environment
           Temperature: 26℃          Humidity: 65%RH        Atmospheric Pressure: 101 KPa
           EUT set Condition: Keep Transmitting (Fast Charge)
           Equipment Level: Class B
           Results: Pass
           Please refer to following diagram for individual




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 13 of 33
 Date: 2019-03-27



D:            Conducted Emission on Neutral Terminal (150kHz to 30MHz)
              EUT Operating Environment
              Temperature: 26℃          Humidity: 65%RH        Atmospheric Pressure: 101 KPa
              EUT set Condition: Keep Transmitting (Fast Charge)
              Equipment Level: Class B
              Results: pass
              Please refer to following diagram for individual




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 14 of 33
 Date: 2019-03-27



6      Radiated Emission Test
6.1     Test Method and test Procedure:

(1)      The EUT was tested according to ANSI C63.10-2013. The radiated test was performed at TIMEWAY
         EMC Laboratory. This site is on file with the FCC laboratory division, Registration No.744189
(2)      The EUT, peripherals were put on the turntable which table size is 1m x 1.5 m, table high 0.8 m. All set up
         is according to ANSI C63.10-2013.
(3)      The frequency spectrum from 9 kHz to 1 GHz was investigated. All readings from 30 MHz to 1 GHz are
         quasi-peak values with RBW=120 kHz/VBW=300 kHz; All readings from 9 kHz to 30 MHz are
         quasi-peak values with RBW=10 kHz/VBW=30 kHz. For the frequency bands 9-90 kHz, 110-490 kHz
         and above 1000 MHz Radiated emission test in these three bands are based on measurements employing
         an average detector. Measurements were made at 3 meters.
(4)      The antenna high is varied from 1 m to 4 m high to find the maximum emission for each frequency.
(5)      Maximizing procedure was performed on the six (6) highest emissions to ensure EUT compliance is with
         all installation combinations. All data was recorded in the peak detection mode. Quasi-peak readings was
         performed only when an emission was found to be marginal (within -4 dB of specification limit), and are
         distinguished with a "QP" in the data table.
(6)      The antenna polarization: Vertical polarization and Horizontal polarization.

         Block diagram of Test setup

         9kHz-30MHz




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 15 of 33
 Date: 2019-03-27



         30MHz-1000MHz




6.2      Configuration of The EUT
         Same as section 5.3 of this report

6.3      EUT Operating Condition
         Same as section 5.4 of this report.

6.4       Radiated Emission Limit
          All emission from a digital device, including any network of conductors and apparatus connected thereto,
          shall not exceed the level of field strength specified below:

B.          Frequencies in restricted band are compiled to limit on Paragraph 15.209.
            Limits for frequency below 30MHz
              Frequency Range (MHz)                        Distance (m)                          Field strength (V/m)
                       0.009-0.490                               300                                  2400/F(kHz)
                       0.490-1.705                                30                                  2400/F(kHz)
                         1.705-30                                 30                                         30




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 16 of 33
 Date: 2019-03-27



            Limits for frequency above 30MHz
              Frequency Range (MHz)                        Distance (m)                       Field strength (dBμV/m)
                            30-88                                   3                                        40.0
                           88-216                                   3                                        43.5
                          216-960                                   3                                        46.0
                         Above 960                                  3                                        54.0
Note:       1. RF Voltage (dBuV) = 20 log RF Voltage (uV)
            2. In the Above Table, the tighter limit applies at the band edges.
            3. Distance refers to the distance in meters between the measuring instrument antenna and the EUT
            4. The emission limits shown in the above table are based on measurements employing a CISPR
            quasi-peak detector except for the frequency bands 9-90 kHz, 110-490 kHz. Radiated emission limits in
            these three bands are based on measurements employing an average detector.

6.5         Test result




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 17 of 33
 Date: 2019-03-27



Measurement data:
Note: Limit dBuV/m @3m = Limit dBuV/m @300m+ 80
Limit dBuV/m @3m = Limit dBuV/m @30m + 40

Normal Charge

9 kHz~30 MHz




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 18 of 33
 Date: 2019-03-27



Fast Charge

9 kHz~30 MHz




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                        Page 19 of 33
 Date: 2019-03-27


A.        General Radiated Emission Data
          Radiated Emission In Horizontal (30MHz----1000MHz)

          EUT set Condition:         Keep Transmitting (Normal Charge)

          Results:                   Pass

          Please refer to following diagram for individual




                                                                                                                                                      

    No.     Frequency    Results        Factor         Limit          Over Limit      Detector    Table       Height      ANT         Verdict
            (MHz)        (dBuV/m)       (dB)           (dBuV/m)       (dB)                        (o)         (cm)

    1       117.278      29.71          -14.88         43.5           -13.79          Peak        337.00      200         H           Pass

    2       128.430      31.03          -16.75         43.5           -12.47          Peak        337.00      200         H           Pass

    3       201.405      36.94          -13.42         43.5           -6.56           Peak        279.00      200         H           Pass




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 20 of 33
 Date: 2019-03-27


B.     General Radiated Emission Data

       Radiated Emission In Vertical (30MHz----1000MHz)

       EUT set Condition:            Keep Transmitting (Normal Charge)

       Results:                      Pass

       Please refer to following diagram for individual




                                                                                                                                                 
 No.      Frequenc      Results          Factor     Limit          Over         Detector     Table (o)    Height       ANT           Verdict
          y (MHz)       (dBuV/m)         (dB)       (dBuV/m)       Limit                                  (cm)
                                                                   (dB)

 1        46.486        30.28            -11.43     40.0           -9.72        Peak         316.00       100          V             Pass

 2        67.821        27.78            -14.55     40.0           -12.22       Peak         263.00       100          V             Pass

 3        117.278       29.47            -14.88     43.5           -14.03       Peak         147.00       100          V             Pass

 4        199.465       32.86            -13.50     43.5           -10.64       Peak         43.00        100          V             Pass




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


    Report No: FCC1903035                                                                                                   Page 21 of 33
    Date: 2019-03-27


C.        General Radiated Emission Data
          Radiated Emission In Horizontal (30MHz----1000MHz)

          EUT set Condition:          Keep Transmitting (Fast Charge)

          Results:                    Pass

          Please refer to following diagram for individual




                                                                                                                                                   

    No.         Frequen     Results       Factor       Limit         Over          Detector     Table (o)     Height       ANT           Verdict
                cy (MHz)    (dBuV/m       (dB)         (dBuV/m       Limit                                    (cm)
                            )                          )             (dB)

    1           68.790      31.77         -15.10       40.0          -8.23         Peak         20.00         200          H             Pass

    2           74.851      31.78         -17.28       40.0          -8.22         Peak         10.00         200          H             Pass

    3           99.580      32.26         -13.60       43.5          -11.24        Peak         10.00         200          H             Pass

    4           136.673     34.10         -17.17       43.5          -9.40         Peak         360.00        200          H             Pass

    5           195.829     33.02         -13.66       43.5          -10.48        Peak         265.00        200          H             Pass

    6           228.073     33.93         -12.77       46.0          -12.07        Peak         84.00         100          H             Pass




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 22 of 33
 Date: 2019-03-27


D.     General Radiated Emission Data

       Radiated Emission In Vertical (30MHz----1000MHz)

       EUT set Condition:            Keep Transmitting (Fast Charge)

       Results:                      Pass

       Please refer to following diagram for individual




                                                                                                                                                      
 No.      Frequency       Results        Factor (dB)     Limit           Over Limit     Detector     Table        Height      ANT         Verdict
          (MHz)           (dBuV/m)                       (dBuV/m)        (dB)                        (o)          (cm)

 1        44.168          35.29          -11.46          40.0            -4.71          Peak         257.00       144         V           Pass

 1*       44.168          32.45          -11.46          40.0            -7.55          QP           257.00       144         V           Pass

 2        77.761          33.80          -17.54          40.0            -6.20          Peak         295.00       100         V           Pass

 3        87.943          35.15          -15.63          40.0            -4.85          Peak         192.00       100         V           Pass

 4        129.400         37.88          -16.81          43.5            -5.62          Peak         242.00       100         V           Pass

 5        137.643         39.63          -17.25          43.5            -3.87          Peak         233.00       100         V           Pass

 6        203.829         35.85          -13.50          43.5            -7.65          Peak         189.00       100         V           Pass




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 23 of 33
 Date: 2019-03-27



7.0       20dB Bandwidth Testing

7.1       Test Procedure
          With the EUT’s antenna attached, the EUT’s 20dB Bandwidth was received by the test
          antenna which was connected to the spectrum analyzer with the START and STOP frequencies set
          to the EUT’s operation band.



7.3       Test Data


            Frequency (MHz)              20dB Bandwidth Emission (kHz)                         Limit (kHz)                      Result
                    0.175                                   3.33                                      --                         Pass


          Measurement under Fast Charge Mode---and it was the worst case.

          Refer to attached plots:




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 24 of 33
 Date: 2019-03-27


20dB Bandwidth
                                   Marker 1 [T1 ndB]                            RBW            1 kHz           RF Att            20 dB
          Ref Lvl                  ndB                  20.00 dB                VBW            3 kHz
           0 dBm                   BW         3.33166333 kHz                    SWT        150 ms              Unit                    dBm
      0
                                                                                                 1 [T1]                  -40.54 dBm
                                                                                                                                               A
                                                                                                              175.06262525 kHz
   -10
                                                                                               ndB                         20.00 dB
                                                                                               BW                 3.33166333 kHz
   -20                                                                                           T1 [T1]                 -60.67 dBm
                                                                                                              173.35921844 kHz
                                                                                                 T2 [T1]                 -60.39 dBm
   -30
                                                                                                              176.69088176 kHz
          1MAX                                                                                                                               1MA
                                                                          1
   -40



   -50


                                                       T1                                 T2
   -60



   -70



   -80



   -90



 -100
          Center 175 kHz                                          1.25 kHz/                                         Span 12.5 kHz

Date:               26.MAR.2019             09:53:52




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 25 of 33
 Date: 2019-03-27



8.0 Antenna Requirement
8.1 Standard Applicable
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a unique
coupling to the intentional radiator shall be considered sufficient to comply with the provisions of this Section.
The manufacturer may design the unit so that a broken antenna can be replaced by the user, but the use of a
standard antenna jack or electrical connector is prohibited. This requirement does not apply to carrier current
devices or to devices operated under the provisions of Sections 15.211, 15.213, 15.217, 15.219, or 15.221. Further,
this requirement does not apply to intentional radiators that must be professionally installed, such as perimeter
protection systems and some field disturbance sensors, or to other intentional radiators which, in accordance with
Section 15.31(d), must be measured at the installation site. However, the installer shall be responsible for ensuring
that the proper antenna is employed so that the limits in this Part are not exceeded.

8.2 Antenna Connected constructions
The antenna is Inductive Loop Antenna. The antenna gain is 0dBi. So it meets the requirement of 15.203




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 26 of 33
 Date: 2019-03-27



9.0     FCC ID Label
                                                 FCC ID: 2ASPF-D8
        This device complies with part 15 of the FCC rules. Operation is subject to the following two
        conditions (1) this device may not cause harmful interference, and (2) this device must accept
        any interference received, including interference that may cause undesired operation.
        The label must not be a stick-on paper label. The label on these products must be permanently affixed
        to the product and readily visible at the time of purchase and must last the expected lifetime of the
        equipment not be readily detachable.

        Mark Location:




                                                                                                        Label Location




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 27 of 33
 Date: 2019-03-27



10.0.       Photo of testing
10.1        Conducted test View




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 28 of 33
 Date: 2019-03-27


10.2          Radiated emission test view




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 29 of 33
 Date: 2019-03-27


        Photo for the EUT




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 30 of 33
 Date: 2019-03-27


        Photo for the EUT




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 31 of 33
 Date: 2019-03-27


       Photo for the EUT




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 32 of 33
 Date: 2019-03-27


       Photo for the EUT




The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.


 Report No: FCC1903035                                                                                                      Page 33 of 33
 Date: 2019-03-27


       Photo for the EUT




                                                             End of the report-

The report refers only to the sample tested and does not apply to the bulk.
This report is issued in confidence to the client and it will be strictly treated as such by the SHENZHEN TIMEWAY TESTING LABORATORIES. It
may not be reproduced rather in its entirety or in part and it may not be used for adverting. The client to whom the report is issued may, however,
show or send it . or a certified copy there of prepared by the SHENZHEN TIMEWAY TESTING LABORATORIES. to his customer. Supplier or
others persons directly concerned. SHENZHEN TIMEWAY TESTING LABORATORIES. will not, without the consent of the client enter into any
discussion of correspondence with any third party concerning the contents of the report.
In the event of the improper use of the report. The SHENZHEN TIMEWAY TESTING LABORATORIES. reserves the rights to withdraw it and to
adopt any other remedies which may be appropriate.



Document Created: 2019-04-11 12:52:28
Document Modified: 2019-04-11 12:52:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC