Test report

FCC ID: 2ASON-DKPA4

Test Report

Download: PDF
FCCID_4242759

                             Global United Technology Services Co., Ltd.

                                                                                  Report No.: GTS201902000075F02



                                       FCC REPORT
    Applicant:                        Dinsafer Innovation Co., Ltd.

    Address of Applicant:             Room 402/403, Floor 4, Area B, Unit B, West Silicon Valley,
                                      No. 5010, Baoan Avenue, Hangcheng Street, Baoan District,
                                      Shenzhen, 518128, China
    Manufacturer:                     Dinsafer Innovation Co., Ltd.

    Address of                        Room 402/403, Floor 4, Area B, Unit B, West Silicon Valley,
    Manufacturer:                     No. 5010, Baoan Avenue, Hangcheng Street, Baoan District,
                                      Shenzhen, 518128, China
    Equipment Under Test (EUT)

      Product Name:                   Wireless Keypad

      Model No.:                      DKPA4(DKP *4,*=A-Z)(DKP A*,*=1-9)

      FCC ID:                         2ASON-DKPA4

    Applicable standards:             FCC CFR Title 47 Part 15 Subpart C

    Date of sample receipt:           March 4, 2019

    Date of Test:                     March 4~ March 26, 2019

    Date of report issued:            March 27, 2019

    Test Result :                     PASS *

*     In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




      Robinson Lo
Laboratory Manager
This results shown in this test report refer only to the sample(s) tested, this test report cannot be reproduced, except in
full, without prior written permission of the company. The report would be invalid without specific stamp of test institute
and the signatures of compiler and approver.


                                                                               Report No.: GTS201902000075F02

2     Version

           Version No.                                 Date                             Description
                 00                              March 27, 2019                           Original




Prepared By:                                                       Date:                March 27, 2019

                                     Project Engineer



Check By:                                                          Date:                March 27, 2019

                                         Reviewer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 2 of 19


                                                                                                            Report No.: GTS201902000075F02

3         Contents
                                                                                                                                                          Page
1    COVER PAGE .............................................................................................................................................1

2     VERSION ...................................................................................................................................................2

3     CONTENTS ...............................................................................................................................................3

4     TEST SUMMARY ......................................................................................................................................4
    4.1       MEASUREMENT UNCERTAINTY .............................................................................................................4
5     GENERAL INFORMATION .......................................................................................................................5
    5.1       GENERAL DESCRIPTION OF EUT ..........................................................................................................5
    5.2       TEST MODE .........................................................................................................................................6
    5.3       DESCRIPTION OF SUPPORT UNITS ........................................................................................................6
    5.4       TEST FACILITY ....................................................................................................................................6
    5.5       TEST LOCATION ..................................................................................................................................6
    5.6       OTHER INFORMATION REQUESTED BY THE CUSTOMER..........................................................................6
6     TEST INSTRUMENTS LIST ......................................................................................................................7

7     TEST RESULTS AND MEASUREMENT DATA .......................................................................................9
    7.1       ANTENNA REQUIREMENT:.....................................................................................................................9
    7.2       CONDUCTED EMISSIONS ....................................................................................................................10
    7.3       RADIATED EMISSION METHOD ............................................................................................................13
    7.4       20DB OCCUPY BANDWIDTH ...............................................................................................................18
8     TEST SETUP PHOTO .............................................................................................................................19

9     EUT CONSTRUCTIONAL DETAILS .......................................................................................................19




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                                                    Page 3 of 19


                                                                               Report No.: GTS201902000075F02

4      Test Summary
                Test Item                              Section in CFR 47                     Result
          Antenna requirement                                 15.203                          Pass
    AC Power Line Conducted Emission                          15.207                          Pass
            Radiated Emission                                 15.209                          Pass
             20dB Bandwidth                                   15.215                          Pass
Pass: The EUT complies with the essential requirements in the standard.




4.1 Measurement Uncertainty
            Test Item                      Frequency Range               Measurement Uncertainty        Notes
        Radiated Emission                    9kHz ~ 30MHz                          4.54dB               (1)
        Radiated Emission                  30MHz ~ 1000MHz                         5.34dB               (1)
    AC Power Line Conducted
                                           0.15MHz ~ 30MHz                         3.44dB               (1)
          Emission
Note (1): The measurement uncertainty is for coverage factor of k=2 and a level of confidence of 95%.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 4 of 19


                                                                               Report No.: GTS201902000075F02

5     General Information
5.1 General Description of EUT
      Product Name:                  Wireless Keypad
      Model No.:                     DKPA4(DKP *4,*=A-Z)(DKP A*,*=1-9)
      Test Model No:                 DKPA4
      Remark: All above models are identical in the same PCB layout, interior structure and electrical circuits.
The only difference is model name for commercial purpose.
      Serial No.:                    2019-DKPA4
      Hardware Version:              Y002-F4-1-V1.1
      Software Version:              Y002F4_V1.0.0.2019.03.20-RS
      Test sample(s) ID:             GTS201902000075-1
      Sample(s) Status               Engineer sample
      Operation Frequency:           125kHz
      Modulation type:               Backscatter modulation
      Antenna Type:                  Inductive loop coil Antenna
      Antenna gain:                  0dBi(declared by applicant)
      Power supply:                  SWITCHING ADAPTER
                                     MODEL: KCH0501000US
                                     INPUT: AC 100-240v, 50/60Hz, 0.6A Max
                                     OUTPUT; DC 5V, 1A
                                     Or
                                     DC 3.7V 890mAh rechargeable Li-ion Battery




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 5 of 19


                                                                               Report No.: GTS201902000075F02


5.2 Test mode
      Transmitting mode                     Keep the EUT in continuously transmitting.
5.3 Description of Support Units
      None
5.4 Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      ● FCC —Registration No.: 381383
      Global United Technology Services Co., Ltd., Shenzhen EMC Laboratory has been registered and fully
      described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
      from the FCC is maintained in files. Registration 381383.
      ● Industry Canada (IC) —Registration No.: 9079A-2
      The 3m Semi-anechoic chamber of Global United Technology Services Co., Ltd. has been registered by
      Certification and Engineering Bureau of Industry Canada for radio equipment testing with Registration
      No.: 9079A-2.
      ● NVLAP (LAB CODE:600179-0)
      Global United Technology Services Co., Ltd., is accredited by the National Voluntary Laboratory
      Accreditation Program (NVLAP). LAB CODE:600179-0
5.5 Test Location
      All tests were performed at:
      Global United Technology Services Co., Ltd.
      No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone, Xixiang Road, Baoan
      District, Shenzhen, Guangdong, China 518102
      Tel: 0755-27798480
      Fax: 0755-27798960
5.6 Other Information Requested by the Customer
      None.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                              Page 6 of 19


                                                                               Report No.: GTS201902000075F02

6      Test Instruments list
Radiated Emission:
                                                                               Inventory     Cal.Date        Cal.Due date
Item      Test Equipment            Manufacturer            Model No.
                                                                                  No.       (mm-dd-yy)       (mm-dd-yy)
         3m Semi- Anechoic
 1                               ZhongYu Electron     9.2(L)*6.2(W)* 6.4(H)    GTS250      July. 03 2015    July. 02 2020
             Chamber
 2         Control Room        ZhongYu Electron 6.2(L)*2.5(W)* 2.4(H)          GTS251           N/A              N/A
 3       EMI Test Receiver     Rohde & Schwarz         ESU26                   GTS203      June. 27 2018    June. 26 2019
                               SCHWARZBECK
 4       BiConiLog Antenna                           VULB9163                  GTS214      June. 27 2018    June. 26 2019
                              MESS-ELEKTRONIK
           Double -ridged      SCHWARZBECK
 5                                                  BBHA 9120 D                GTS208      June. 27 2018    June. 26 2019
           waveguide horn     MESS-ELEKTRONIK
6          Horn Antenna         ETS-LINDGREN             3160                  GTS217      June. 27 2018    June. 26 2019
7        EMI Test Software          AUDIX                 E3                    N/A             N/A              N/A
8          Coaxial Cable             GTS                  N/A                  GTS213      June. 27 2018    June. 26 2019
9          Coaxial Cable             GTS                  N/A                  GTS211      June. 27 2018    June. 26 2019
10          Coaxial cable            GTS                  N/A                  GTS210      June. 27 2018    June. 26 2019
11         Coaxial Cable             GTS                  N/A                  GTS212      June. 27 2018    June. 26 2019
12     Amplifier(100kHz-3GHz)         HP                8347A                  GTS204      June. 27 2018    June. 26 2019
13     Amplifier(2GHz-20GHz)          HP               84722A                  GTS206      June. 27 2018    June. 26 2019
                                                    AFS33-18002
14      Amplifier (18-26GHz)   Rohde & Schwarz                                 GTS218      June. 27 2018    June. 26 2019
                                                    650-30-8P-44
15           Band filter             Amindeon                 82346            GTS219      June. 27 2018    June. 26 2019
16         Power Meter                 Anritsu              ML2495A            GTS540      June. 27 2018    June. 26 2019
17        Power Sensor                 Anritsu              MA2411B            GTS541      June. 27 2018    June. 26 2019
         Wideband Radio
18                               Rohde & Schwarz            CMW500             GTS575      June. 27 2018    June. 26 2019
       Communication Tester
19            Splitter                 Agilent              11636B             GTS237      June. 27 2018    June. 26 2019
20        Loop Antenna                ZHINAN               ZN30900A            GTS534      June. 27 2018    June. 26 2019
            Breitband
21                               SCHWARZBECK               BBHA 9170           GTS579      Oct. 20 2018     Oct. 19 2019
           hornantenne
22           Amplifier                  TDK                 PA-02-02           GTS574      Oct. 20 2018     Oct. 19 2019
23           Amplifier                  TDK                 PA-02-03           GTS576      Oct. 20 2018     Oct. 19 2019
       PSA Series Spectrum
24                               Rohde & Schwarz              FSP              GTS578      June. 27 2018    June. 26 2019
             Analyzer




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                  Page 7 of 19


                                                                                Report No.: GTS201902000075F02


Conducted Emission

                                                                                Inventory      Cal.Date       Cal.Due date
Item       Test Equipment           Manufacturer            Model No.
                                                                                  No.         (mm-dd-yy)       (mm-dd-yy)

 1        Shielding Room          ZhongYu Electron    7.3(L)x3.1(W)x2.9(H)      GTS252       May.16 2014      May.15 2019

 2       EMI Test Receiver              R&S                  ESCI 7             GTS552      June. 27 2018     June. 26 2019

 3         Coaxial Switch         ANRITSU CORP               MP59B              GTS225      June. 27 2018     June. 26 2019

                                  SCHWARZBECK
 4     Artificial Mains Network                            NSLK8127             GTS226      June. 27 2018     June. 26 2019
                                       MESS
                                                                                            June. 27 2018    June. 26 2019
 5         Coaxial Cable                GTS                   N/A               GTS227

 6       EMI Test Software            AUDIX                    E3                 N/A            N/A              N/A

 7         Thermo meter                 KTJ                  TA328              GTS233      June. 27 2018     June. 26 2019

                                     Elektronik-
 8        Absorbing clamp                                    MDS21              GTS229      June. 27 2018     June. 26 2019
                                   Feinmechanik


General used equipment:
                                                                                              Cal.Date       Cal.Due date
Item       Test Equipment           Manufacturer           Model No.      Inventory No.
                                                                                             (mm-dd-yy)      (mm-dd-yy)
       Humidity/ Temperature
 1                                       KTJ                TA328              GTS243       June. 27 2018    June. 26 2019
             Indicator
 2           Barometer               ChangChun              DYM3               GTS255       June. 27 2018    June. 26 2019




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                   Page 8 of 19


                                                                                 Report No.: GTS201902000075F02

7     Test results and Measurement Data
7.1 Antenna requirement:
      Standard requirement:            FCC Part15 C Section 15.203
      15.203 requirement:
       An intentional radiator shall be designed to ensure that no antenna other than that furnished by the responsible
       party shall be used with the device. The use of a permanently attached antenna or of an antenna that uses a
       unique coupling to the intentional radiator, the manufacturer may design the unit so that a broken antenna can be
       replaced by the user, but the use of a standard antenna jack or electrical connector is prohibited.
      EUT Antenna:

        The antenna is Inductive loop coil Antenna, the best case gain of the antenna is 0dBi, reference to the appendix II

        for details.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                                    Page 9 of 19


                                                                               Report No.: GTS201902000075F02


7.2 Conducted Emissions
      Test Requirement:               FCC Part15 C Section 15.207
      Test Method:                    ANSI C63.10:2013
      Test Frequency Range:           150KHz to 30MHz
      Class / Severity:               Class B         Class B
      Receiver setup:                 RBW=9KHz, VBW=30KHz, Sweep time=auto
      Limit:                                                                        Limit (dBuV)
                                          Frequency range (MHz)
                                                                         Quasi-peak              Average
                                                0.15-0.5                   66 to 56*             56 to 46*
                                                 0.5-5                         56                   46
                                                  5-30                         60                   50
                                      * Decreases with the logarithm of the frequency.
      Test setup:




      Test procedure:                 1. The E.U.T and simulators are connected to the main power through a
                                         line impedance stabilization network (L.I.S.N.). This provides a
                                         50ohm/50uH coupling impedance for the measuring equipment.
                                      2. The peripheral devices are also connected to the main power through a
                                         LISN that provides a 50ohm/50uH coupling impedance with 50ohm
                                         termination. (Please refer to the block diagram of the test setup and
                                         photographs).
                                      3. Both sides of A.C. line are checked for maximum conducted
                                         interference. In order to find the maximum emission, the relative
                                         positions of equipment and all of the interface cables must be changed
                                         according to ANSI C63.10 on conducted measurement.
      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass


Measurement data:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 10 of 19


                                                                               Report No.: GTS201902000075F02


Line:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 11 of 19


                                                                               Report No.: GTS201902000075F02


Neutral:




Notes:
1. An initial pre-scan was performed on the line and neutral lines with peak detector.
2. Quasi-Peak and Average measurement were performed at the frequencies with maximized peak emission.
3. Final Level =Receiver Read level + LISN Factor + Cable Loss
4. If the average limit is met when using a quasi-peak detector receiver, the EUT shall be deemed to meet
     both limits and measurement with the average detector receiver is unnecessary.




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 12 of 19


                                                                               Report No.: GTS201902000075F02


7.3 Radiated Emission Method
      Test Requirement:               FCC Part15 C Section 15.209
      Test Method:                    ANSI C63.10:2013
      Test Frequency Range:           9kHz to 1GHz
      Test site:                      Measurement Distance: 3m
      Receiver setup:                    Frequency          Detector       RBW          VBW          Remark
                                        9kHz - 30MHz      PK,AV,QP         10kHz       30kHz        PK,AV,QP
                                        30MHz-1GHz        Quasi-peak 120kHz           300kHz Quasi-peak Value
                                                             Peak          1MHz        3MHz        Peak Value
                                         Above 1GHz
                                                             Peak          1MHz         10Hz     Average Value
                                      Remark: For the frequency bands 9-90 kHz, 110-490 kHz and above 1000
                                      MHz. Radiated emission test in these three bands are based on
                                      measurements employing an average detector.
      Limit:                          Limits for frequency below 30MHz
      (Spurious Emissions)                                                     Measurement
                                          Frequency        Limit (uV/m)                              Remark
                                                                               Distance(m)
                                         0.009-0.490       2400/F(kHz)              300            PK,AV,QP
                                         0.490-1.705       24000/F(kHz)              30         Quasi-peak Value
                                           1.705-30             30                   30         Quasi-peak Value
                                      Limits for frequency Above 30MHz
                                                 Frequency             Limit (dBuV/m @3m)            Remark
                                              30MHz-88MHz                      40.00            Quasi-peak Value
                                              88MHz-216MHz                     43.50            Quasi-peak Value
                                             216MHz-960MHz                     46.00            Quasi-peak Value
                                               960MHz-1GHz                     54.00            Quasi-peak Value
                                                                               54.00              Average Value
                                                Above 1GHz
                                                                               74.00               Peak Value
                                      Remark: The emission limits shown in the above table are based on
                                      measurements employing a CISPR quasi-peak detector except for the
                                      frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated
                                      emission limits in these three bands are based on measurements
                                      employing an average detector.
      Test Procedure:                 1. The EUT was placed on the top of a rotating table 0.8 meters above the
                                         ground at a 3 meter camber. The table was rotated 360 degrees to
                                         determine the position of the highest radiation.
                                      2. The EUT was set 3 meters away from the interference-receiving
                                         antenna, which was mounted on the top of a variable-height antenna
                                         tower.
                                      3. The antenna height is varied from one meter to four meters above the
                                         ground to determine the maximum value of the field strength. Both
                                         horizontal and vertical polarizations of the antenna are set to make the
                                         measurement.
                                      4. For each suspected emission, the EUT was arranged to its worst case
                                         and then the antenna was tuned to heights from 1 meter to 4 meters and
                                         the rota table was turned from 0 degrees to 360 degrees to find the
                                         maximum reading.
                                      5. The test-receiver system was set to Peak Detect Function and Specified
                                         Bandwidth with Maximum Hold Mode.
                                      6. If the emission level of the EUT in peak mode was 10dB lower than the

Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 13 of 19


                                                                              Report No.: GTS201902000075F02
                                         limit specified, then testing could be stopped and the peak values of the
                                         EUT would be reported. Otherwise the emissions that did not have 10dB
                                         margin would be re-tested one by one using peak, quasi-peak or
                                         average method as specified and then reported in a data sheet.
                                      7. The radiation measurements are performed in X, Y, Z axis positioning.
                                         And found the Y axis positioning which it is worse case, only the test
                                         worst case mode is recorded in the report.
      Test setup:                     Below 30MHz




                                      30MHz ~ 1000MHz




      Test Instruments:               Refer to section 6.0 for details
      Test mode:                      Refer to section 5.2 for details
      Test results:                   Pass



Measurement data:




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                            Page 14 of 19


                                                                               Report No.: GTS201902000075F02

Measurement data:
Note: Limit dBuV/m @3m = Limit dBuV/m @300m+ 80
      Limit dBuV/m @3m = Limit dBuV/m @30m + 40
Below 30MHz




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 15 of 19


                                                                               Report No.: GTS201902000075F02

30MHz ~ 1GHz
Horizontal




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 16 of 19


                                                                               Report No.: GTS201902000075F02

Vertical




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 17 of 19


                                                                               Report No.: GTS201902000075F02

7.4 20dB Occupy Bandwidth
      Test Requirement:           FCC Part15 C Section 15.215
      Test Method:                ANSI C63.10:2013
      Test setup:




      Test Instruments:           Refer to section 6.0 for details
      Test mode:                  Refer to section 5.2 for details
      Test results:               Pass


Measurement Data


         Test frequency                         20dB bandwidth
                                                                                            Result
             (KHz)                                  (KHz)
            125.00                                  2.838                                    Pass




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 18 of 19


                                                                               Report No.: GTS201902000075F02

8     Test Setup Photo
       Reference to the appendix I for details.


9     EUT Constructional Details
       Reference to the appendix II for details.


                                                   ------End------




Global United Technology Services Co., Ltd.
No. 301-309, 3/F., Jinyuan Business Building, No.2, Laodong Industrial Zone,
Xixiang Road, Baoan District, Shenzhen, Guangdong, China 518102
Telephone: +86 (0) 755 2779 8480 Fax: +86 (0) 755 2779 8960                             Page 19 of 19



Document Created: 2019-04-17 20:43:27
Document Modified: 2019-04-17 20:43:27

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC