RF Exposure Report

FCC ID: 2ASNP-E79X3562018

RF Exposure Info

Download: PDF
FCCID_4222675

             Exhibit: RF Exposure – FCC
                               FCC ID: 2ASNP-E79X3562018
                                 IC: 24793-E79X3562018




                                                                                    Report File #: 7169003484B-001
© TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc


 Client               dormakaba USA Inc


 Product              Electronic Lock: E-Plex 7900



RF Exposure – FCC
The EUT contains a 13.56 MHz RFID reader. The minimum separation distance from the
radiating structure to the extremity of a user is 5 mm. This distance is the shortest distance
from any antenna to the surface as stated by the manufacturer during normal operation.

Therefore SAR test exclusion was evaluated according to FCC KDB 447498 D01 v06
Sections 4.3.2 and 4.3.1.

General SAR test exclusion guidance:

13.56 MHz Transmitter
As per FCC KDB 447498 Section and 4.3.1 c) 2), the 10-g extremity SAR Test Exclusion
Threshold is given by

c).2) For test separation distances ≤ 50 mm, the power threshold determined by the equation in
c).1) for 50 mm and 100 MHz is multiplied by ½

c).1) For test separation distances > 50 mm and < 200 mm, the power threshold at the
corresponding test separation distance at 100 MHz in step b) is multiplied by [1 + log(100/f(MHz))]

b).1) {[Power allowed at numeric threshold for 50 mm in step a)] + [(test separation distance –
50mm)·(f(MHz)/150)]} mW, for 100 MHz to 1500 MHz

The formula will be then:
½ ({[Power allowed at numeric threshold for 50 mm in step 4.3.1 a)] + [(test separation distance –
50mm)·(f(MHz)/150)]} { [1 + log(100/f(MHz))] })mW

Where:
Test separation distance is 50 mm and f = 100 MHz.

Which results in
½ [Power allowed at numeric threshold for 50 mm in step 4.3.1 a)] mW




       Page 2 of 4                     Report Issued: 3/29/2019                                    Report File #: 7169003484B-001

              © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc.


 Client               dormakaba USA Inc


 Product              Electronic Lock: E-Plex 7900



SAR Calculations: 13.56 MHz transmitter

The power allowed for numeric threshold of 7.5, for f = 0.1 GHz, and for a min. test
distance of ≤ 5mm

                                        (𝑚𝑎𝑥. 𝑝𝑜𝑤𝑒𝑟, 𝑚𝑊)
                                                               × √𝑓 = 7.5
                                      (𝑚𝑖𝑛. 𝑡𝑒𝑠𝑡 𝑑𝑖𝑠𝑡𝑎𝑛𝑐𝑒, 𝑚𝑚)

                                                                                      7.5 × 50 𝑚𝑚
                                        (𝑚𝑎𝑥. 𝑝𝑜𝑤𝑒𝑟, 𝑚𝑊) =
                                                                                               √0.1

                                          (𝑚𝑎𝑥. 𝑝𝑜𝑤𝑒𝑟, 𝑚𝑊) = 1185.8 𝑚𝑊

And therefore, ½ power allowed is 592.9 mW

The EIRP of the transmitter is calculated from field strength at 3 m using
Equation 22 and guidance form Annex G of ANSI C63.10

EIRP = EMeas – 95.2


The transmitter has a field strength of 56 dBuV/m @ 3 m

          EIRP = 56 – 95.2 = -39.2 dBm = 0.0001 mW

SAR Exclusion Threshold condition is met with peak EIRP.




      Page 3 of 4                      Report Issued: 3/29/2019                                    Report File #: 7169003484B-001

              © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc.


 Client                 dormakaba USA Inc


 Product                Electronic Lock: E-Plex 7900



2.4 GHz Transmitter
As per FCC KDB 447498 Section and 4.3.1 a), the 10-g extremity SAR Test Exclusion
Threshold is given by

For 100 MHz to 6 GHz and test separation distances ≤ 50 mm, the 10-g SAR test exclusion
thresholds are determined by the following:
[(max. power of channel, including tune-up tolerance, mW) / (min. test separation distance,
mm)]*[√f(GHz)] ≤ 7.5 for 10-g extremity SAR
where
f(GHz) is the RF channel transmit frequency in GHz

SAR Calculations: 2.4 GHz transmitter

The power allowed for numeric threshold of 7.5, for f = 2.4 GHz, and for a min. test
distance of ≤ 5mm

                                          (𝑚𝑎𝑥. 𝑝𝑜𝑤𝑒𝑟, 𝑚𝑊)
                                                                 × √𝑓 = 7.5
                                        (𝑚𝑖𝑛. 𝑡𝑒𝑠𝑡 𝑑𝑖𝑠𝑡𝑎𝑛𝑐𝑒, 𝑚𝑚)

The 2.4GHz transmitter maximum power as per certification report # EI0036-2 issued by
Bureau Veritas on 2018-07-23, is 22dBm (158.5mW).
The maximum duty cycle declared by the manufacturer is 9.5%, which leads to a correction
factor of 10 x log (9.5/100) = -10.2dB.
Applying the correction factor, the formula above will be:

(11.8 dBm / min test distance, mm)x√2.4 = 15.1/5 *1.55 = 4.7 ≤ 7.5

SAR Exclusion Threshold condition is met with peak conducted power.




        Page 4 of 4                      Report Issued: 3/29/2019                                    Report File #: 7169003484B-001

                © TÜV SÜD Canada Inc. This test report shall not be reproduced except in full, without written approval of TÜV SÜD Canada Inc.



Document Created: 2019-03-29 13:53:59
Document Modified: 2019-03-29 13:53:59

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC