RF Exposure (MPE)

FCC ID: 2ASLSRU700A10

RF Exposure Info

Download: PDF
FCCID_4307026

MPE/RF EXPOSURE EVALUATION REPORT

FCC Part 15 RF Exposure Requirements

Report No.: PULO01-U2_FCC_MPE Rev A




                             Company: Puloli Inc.

                           Model Name: RU700A 1.0


MPE/RF EXPOSURE EVALUATION REPORT


                       Test of: Puloli Inc.

    To: FCC CFR 47 Part 15 RF Exposure Requirements

   Test Report Serial No.: PULO01-U2_FCC_MPE Rev A

                This report supersedes: NONE


               Applicant:     Sonos Inc
                              649 Mission Street Ste 416
                              San Francisco, California 94105
                              USA



              Issue Date:     23rd May 2019



   This Test Report is Issued Under the Authority of:

      MiCOM Labs, Inc.
      575 Boulder Court
      Pleasanton California 94566
      USA
      Phone: +1 (925) 462-0304
      Fax: +1 (925) 462-0306
      www.micomlabs.com

    MiCOM Labs is an ISO 17025 Accredited Testing Laboratory


                                                                     Title:           Puloli, Inc. RU700A 1.0
                                                                       To:            FCC Part 15 RF Exposure Requirements
                                                                  Serial #:           PULO01-U2_FCC_MPE Rev A




1.1. MAXIMUM PERMISSABLE EXPOSURE

Calculations for Maximum Permissible Exposure Levels
Power Density = Pd (mW/cm2) = EIRP/(4*π*d2)
EIRP = P * G
P = Peak output power (mW)
G = Antenna numeric gain (numeric)
d = Separation distance (cm)
Numeric Gain = 10 ^ (G (dBi)/10)

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of power density is
f/1500 mW/cm2

These calculations represent worst case in terms of the exposure levels.
                                                                     Calculated
                 Frequency                       Peak       Peak                                            Power
                              Ant    Numeric                           Power                                       Min Calculated
  Freq. Band         of                        Output      Output                                          Density
                             Gain     Gain                             Density                                     safe distance
    (MHz)       Calculation                     Power      Power                                            Limit
                             (dBi) (numeric)                        (mW/cm2) @                                     for Limit (cm)
                   (MHz)                        (dBm)       (mW)                                          (mW/cm2)
                                                                        20cm
    787 - 788       787.411875        5.0          3.16       20.99          125.6           0.08            0.525             5.86


Note: for mobile or fixed location transmitters the minimum separation distance is 20cm, even if calculations
indicate the MPE distance to be less.



Specification
Maximum Permissible Exposure Limits



FCC §1.1310 Limit = f/1500 mW/cm2 from 1.310 Table 1 for devices operating in the <900 MHz band




                 Issue Date:       23rd May 2019                                               Page:      3 of 5
                This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                           personnel. All changes will be noted in the Document History section of the report.
    MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


                                                                    Title:           Puloli, Inc. RU700A 1.0
                                                                      To:            FCC Part 15 RF Exposure Requirements
                                                                 Serial #:           PULO01-U2_FCC_MPE Rev A




Specification - Maximum Permissible Exposure Limits

                             TABLE 1—LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
  Frequency range          Electric field strength          Magnetic field strength          Power density         Averaging time
       (MHz)                        (V/m)                           (A/m)                      (mW/cm2)              (minutes)

                                       (A) Limits for Occupational/Controlled Exposure

     0.3-3.0                         614                              1.63                        *100                     6
      3.0-30                       1842/f                            4.89/f                      *900/f2                   6
     30-300                         61.4                             0.163                         1.0                     6
    300-1,500                         --                                --                        f/300                    6
  1,500-100,000                       --                                --                            5                    6
                                  (B) Limits for General Population/Uncontrolled Exposure

     0.3-1.34                        614                              1.63                        *100                    30
     1.34-30                        824/f                            2.19/f                      *180/f2                  30
     30-300                         27.5                             0.073                         0.2                    30
    300-1,500                         --                                --                       f/1500                   30
  1,500-100,000                       --                                --                         1.0                    30

                                       f = frequency in MHz * = Plane-wave equivalent power density




                Issue Date:       23rd May 2019                                               Page:       4 of 5
               This test report may be reproduced in full only. The document may only be updated by MiCOM Labs
                          personnel. All changes will be noted in the Document History section of the report.
   MiCOM Labs, 575 Boulder Court, Pleasanton, California 94566 USA, Phone: +1 (925) 462 0304, Fax: +1 (925) 462 0306, www.micomlabs.com


       575 Boulder Court
Pleasanton, California 94566, USA
     Tel: +1 (925) 462 0304
     Fax: +1 (925) 462 0306
      www.micomlabs.com



Document Created: 2019-06-05 04:40:50
Document Modified: 2019-06-05 04:40:50

© 2024 FCC.report