RF Exposure

FCC ID: 2ASJOSH001-2

RF Exposure Info

Download: PDF
FCCID_4312495

FCC ID: 2ASJOSH001-2                         Product Name: Power charging station


                        RF Exposure Considerations

1. Measuring Standard
  KDB 680106 D01 RF Exposure Wireless Charging Apps v03

2. Requirements
  According to the item 5.2 of KDB 680106 D01v03:
  For device designed for typical desktop applications, RF exposure evaluation should be
  conducted assuming a user separation distance of 20cm (Top) and 15cm (Edge). E and H
  field strength measurements or numerical modeling may be used to demonstrate
  compliance. Measurements should be made from all sides and the top of the primary/client
  pair, with the 20cm(Top) and 15cm(Edge) measured from the center of the probe(s) to the
  edge of the device.
                        Limits For Maximum Permissible Exposure (MPE)


FCC ID: 2ASJOSH001-2                          Product Name: Power charging station




3. Test Setup




Note:
1. The RF exposure test is performed in the shield room.
2. The test distance is between the edge of the charger and geometric centre of probe.



4. Test Equipment List
     Test Equipment         Manufacturer         Model No.            Calibration Due
     Magnetic field meter   NARDA                ELT-400              Sep. 02, 2019


FCC ID: 2ASJOSH001-2                              Product Name: Power charging station


5. Test Result
The EUT does comply with item 5 KDB 680106 D01v03.
(1) Power transfer frequency is less than 1MHz. (Conform)
    - The frequency for EUT is 110-205KHz.
(2) Output power from each primary coil is less than or equal to 15 watts. (Conform)
    -10w max.
(3) The transfer system includes only single primary and secondary coils. This includes
    charging systems that may have multiple primary coils and clients that are able to detect
    and allow coupling only between individual pairs of coils. (Conform)
    -only single coil.
(4) Client device is placed directly in contact with the transmitter. (Conform)
    -yes, client device is put specification area of EUT directly.
(5) Mobile exposure conditions only (portable exposure conditions are not covered by this
    exclusion.) (Conform)
    -yes, EUT work with plug in and AC power.
(6) The aggregate H-field strengths at 15cm surrounding the device and 20cm above the top
    surface from all simultaneous transmitting coils are demonstrated to be less than 50% of
    the MPE limit. (Conform)
    -yes, please see data.



 E-Filed Strength at 15cm surrounding the EUT and 20cm above the top surface of the EUT
                                                                       50%
                Test        Test      Test        Test        Test                Limits
                                                                       Limits
 Charging     Position   Position   Position    Position    Position              Test     Result
                                                                       Test
                  A          B          C          D           E                  (V/m)
                                                                       (V/m)
    1%
                0.38      0.40        0.29        0.39        0.41      307        614     Pass
  Battery
   50%
                1.26      1.17        1.08        1.25        1.31      307        614     Pass
  Battery
   99%
                2.11      2.27        2.37        2.42        2.52      307        614     Pass
  Battery
  Standby       0.28      0.31        0.40        0.37        0.36      307        614     Pass


FCC ID: 2ASJOSH001-2                            Product Name: Power charging station




 H-Filed Strength at 15cm surrounding the EUT and 20cm above the top surface of the EUT
                                                                     50%
               Test       Test       Test       Test       Test               Limits
                                                                     Limits
 Charging     Position   Position   Position   Position   Position            Test     Result
                                                                     Test
                 A          B          C          D          E                (A/m)
                                                                     (A/m)
    1%
               0.041      0.039      0.043      0.028      0.064     0.815    1.63     Pass
  Battery
   50%
               0.15       0.14       0.16       0.13       0.11      0.815    1.63     Pass
  Battery
   99%
               0.33       0.29       0.30       0.44       0.45      0.815    1.63     Pass
  Battery
 Standby       0.16       0.17       0.15       0.14       0.11      0.815    1.63     Pass
Note: The aggregate H-filed strengths at 15cm surrounding the device and 20cm above the top
surface.
A/m=uT/1.25



Document Created: 2019-05-29 07:04:08
Document Modified: 2019-05-29 07:04:08

© 2024 FCC.report