RF exposure report

FCC ID: 2ASHX-XTHP005

RF Exposure Info

Download: PDF
FCCID_4205803

                                      RF Exposure evaluation



According to 447498 D01 General RF Exposure Guidance v05

The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances

≤ 50 mm are determined by:

[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance, mm)] ·[√

f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR, where

 f(GHz) is the RF channel transmit frequency in GHz

 Power and distance are rounded to the nearest mW and mm before calculation

 The result is rounded to one decimal place for comparison



Worse case is as below: [2441MHz 0.20dBm( 1.047 mW)output power]



(1.047   mW /5mm) ·[√2.441 (GHz)]= 0.33 <3.0 for 1-g SAR



Then SAR evaluation is not required



Document Created: 2019-03-19 11:39:56
Document Modified: 2019-03-19 11:39:56

© 2024 FCC.report