REPORT

FCC ID: 2ASHB-WSTHE

Test Report

Download: PDF
FCCID_4256045

SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




                                                  FCC TEST REPORT
                                                                 For
                                                     Wheely-Safe Ltd
                                                       TPMS Sensor
                                                Test Model: WSTHE(F)-2
                                Additional Model: Please Refer to Page 6



  Prepared for                              : Wheely-Safe Ltd
  Address                                   : Unit 8, Queens Drive Industrial Estate, Burntwood,
                                              Staffordshire. WS7 4QF UNITED KINGDOM

  Prepared by                               : Shenzhen LCS Compliance Testing Laboratory Ltd.
  Address                                   : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an
                                              Avenue, Bao’an District, Shenzhen, Guangdong, China
  Tel                                       : (+86)755-82591330
  Fax                                       : (+86)755-82591332
  Web                                       : www.LCS-cert.com
  Mail                                      : webmaster@LCS-cert.com

  Date of receipt of test                   :
                                                 April 01, 2019
  sample
  Number of tested samples                  :    1
  Serial number                             :    Prototype
  Date of Test                              :    April 01, 2019 ~ April 16, 2019
  Date of Report                            :    April 17, 2019




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 1 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA

                                              FCC/IC TEST REPORT
                                           FCC CFR 47 PART 15C(15.231)
Report Reference No. .......... : LCS190107166AEA
Date of Issue ........................... : April 17, 2019
Testing Laboratory Name ..... : Shenzhen LCS Compliance Testing Laboratory Ltd.
Address ................................... : 1/F., Xingyuan Industrial Park, Tongda Road, Bao’an
                                              Avenue, Bao’an District, Shenzhen, Guangdong, China
Testing Location/ Procedure .... : Full application of Harmonised standards ■
                                              Partial application of Harmonised standards □
                                              Other standard testing method □
Applicant’s Name .................. : Wheely-Safe Ltd

Address ................................... : Unit 8, Queens Drive Industrial Estate, Burntwood,
                                              Staffordshire. WS7 4QF UNITED KINGDOM
Test Specification
Standard .................................. : FCC CFR 47 PART 15 Subpart C
Test Report Form No. .............. : LCSEMC-1.0
TRF Originator ......................... : Shenzhen LCS Compliance Testing Laboratory Ltd.
Master TRF.............................. : Dated 2011-03
Shenzhen LCS Compliance Testing Laboratory Ltd. All rights reserved.
This publication may be reproduced in whole or in part for non-commercial purposes as long
as the Shenzhen LCS Compliance Testing Laboratory Ltd. is acknowledged as copyright
owner and source of the material. Shenzhen LCS Compliance Testing Laboratory Ltd. takes
no responsibility for and will not assume liability for damages resulting from the reader's
interpretation of the reproduced material due to its placement and context.
Test Item Description. ........... : TPMS Sensor
Trade Mark .............................. : Michelin
Test Model ............................... : WSTHE(F)-2
Ratings .................................... : DC 3V by CR2032 Battery
Result .................................... : Positive


        Compiled by:                                  Supervised by:                                   Approved by:




   Ace Chai / administrators                 Calvin Weng/ Technique principal                       Gavin Liang/ Manager




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 2 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA



                                             FCC/IC TEST REPORT
                                                                                                April 17, 2019
   Test Report No. : LCS190107166AEA                                                              Date of issue



   Test Mode............................... : WSTHE(F)-2

   EUT........................................ : TPMS Sensor

   Applicant............................... : Wheely-Safe Ltd
   Address.................................. : Unit 8, Queens Drive Industrial Estate, Burntwood, Staffordshire.
                                                  WS7 4QF UNITED KINGDOM
   Telephone.............................. : /
   Fax......................................... : /

   Manufacturer........................ : Gobiz Electronics Limited
   Address.................................. : Rm 201, 2/F, Hi-Tech Centre, 9 Choi Yuen Road, Sheung Shui,
                                                  N.T., Hong Kong, China
   Telephone..............................
                                                : /
   .
   Fax......................................... : /

   Factory..................................      : Gobiz Electronics Limited
   Address..................................      : Rm 201, 2/F, Hi-Tech Centre, 9 Choi Yuen Road, Sheung Shui,
   .                                                N.T., Hong Kong, China
   Telephone..............................        : /
   Fax.........................................   : /




                          Test Result                                                          Positive
  The test report merely corresponds to the test sample.
  It is not permitted to copy extracts of these test result without the written permission of the test
  laboratory.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 3 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


                                                    Revision History
       Revision                        Issue Date                          Revisions                        Revised By
         000                          April 17, 2019                      Initial Issue                     Gavin Liang




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 4 of 30


 SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                                                   FCC ID:2ASHB-WSTHE                      Report No.:LCS190107166AEA




                                                                TABLE OF CONTENTS
1. GENERAL INFORMATION ................................................................................................................................... 6
   1.1. DESCRIPTION OF DEVICE (EUT) ........................................................................................................................ 6
   1.2. OBJECTIVE .......................................................................................................................................................... 7
   1.3. ENVIRONMENTAL CONDITIONS ........................................................................................................................... 7
   1.4. HOST SYSTEM CONFIGURATION LIST AND DETAILS .......................................................................................... 7
   1.5. EXTERNAL I/O PORT ........................................................................................................................................... 7
   1.6. DESCRIPTION OF TEST FACILITY ........................................................................................................................ 8
   1.7. STATEMENT OF THE MEASUREMENT UNCERTAINTY ......................................................................................... 8
2. TEST METHODOLOGY ......................................................................................................................................... 9
   2.1. EUT CONFIGURATION ........................................................................................................................................ 9
   2.2. EUT EXERCISE ................................................................................................................................................... 9
   2.3. GENERAL TEST PROCEDURES ........................................................................................................................... 9
   2.4. INSTRUMENT CALIBRATION ................................................................................................................................. 9
   2.5. TEST MODE ....................................................................................................................................................... 10
3. SYSTEM TEST CONFIGURATION .................................................................................................................... 11
   3.1. JUSTIFICATION .................................................................................................................................................. 11
   3.2. EUT EXERCISE SOFTWARE .............................................................................................................................. 11
   3.3. SPECIAL ACCESSORIES .................................................................................................................................... 11
   3.4. BLOCK DIAGRAM/SCHEMATICS......................................................................................................................... 11
   3.5. EQUIPMENT MODIFICATIONS ............................................................................................................................ 11
   3.6. TEST SETUP ...................................................................................................................................................... 11
4. SUMMARY OF TEST RESULTS ........................................................................................................................ 12
5. TEST ITEMS AND RESULTS ............................................................................................................................. 13
   5.1. DURATION OF EACH TRANSMISSION AND THE SILENT PERIOD ......................................................................... 13
   5.2. TRANSMITTER FIELD STRENGTH OF EMISSIONS .............................................................................................. 15
   5.3. 20DB BANDWIDTH EMISSIONS ......................................................................................................................... 25
   5.4. DUTY CYCLE ...................................................................................................................................................... 26
   5.5. ANTENNA REQUIREMENT .................................................................................................................................. 28
6. LIST OF MEASURING EQUIPMENTS .............................................................................................................. 29
7. TEST SETUP PHOTOGRAPHS OF EUT .......................................................................................................... 30
8. EXTERIOR PHOTOGRAPHS OF THE EUT ..................................................................................................... 30
9. INTERIOR PHOTOGRAPHS OF THE EUT ...................................................................................................... 30




      This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                     Page 5 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


 1. GENERAL INFORMATION

         1.1. Description of Device (EUT)
                 EUT                             : TPMS Sensor

                 Test Model                      : WSTHE(F)-2

                                                   WSTHE(R)-2, WSTLE-1, WSTLI-1, ISP-1,
                                                   FMSTLE(F)-1, FMSTLE(R)-1, FCSTLE(FL)-1,
                 Additional Model                : FCSTLE(FR)-1, FCSTLE(RL)-1, FCSTLE(RR)-1,
                                                   FTSTLE(FL)-1, FTSTLE(FR)-1, FTSTLE(RL)-1,
                                                   FTSTLE(RR)-1

                                                     PCB board, structure and internal of these model(s) are
                 Model Declaration               :
                                                     the same, So no additional models were tested.

                 Power Supply                    : DC 3V by CR2032 Battery

                 Hardware Version                : V1.0

                 Software Version                : V1.0

                 Transmit Frequency : 433.92MHz

                 Number of Channels : 1

                 Modulation Type                 : ASK

                 Antenna Description : Internal Antenna, 0dBi (Max.)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 6 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


         1.2. Objective
               The primary objective of the manufacturer is compliance with Subpart C of Part 15 of
               FCC Rules for the radiated and conducted emissions of intentional radiators and
               Industry CanadaRSS-210 for Low Power, License-Exempt Radio Communication
               Devices. Certification ofthese devices is required as a prerequisite to marketing as
               defined in Part 2 the FCC Rules and Industry Canada Radio Standards Procedure
               RSP-100.

               Certification is a procedure where the manufacturer or a contracted laboratory
               makes measurements and submits the test data and technical information to the
               FCC. The FCC issues a grant of equipment authorization upon successful
               completion of their review of the submitted documents. Once the equipment
               authorization has been obtained, the label indicating compliance must be attached
               to all identical units, which are subsequently manufactured.

               Maintenance of compliance is the responsibility of the manufacturer. Any
               modification of the product which may result in increased emissions should be
               checked to ensure compliance has been maintained (i.e., printed circuit board layout
               changes, different line filter, different power supply, harnessing or I/O cable changes,
               etc.).


         1.3. Environmental Conditions
               During the measurement the environmental conditions were within the listed ranges:
               - Temperature: 15-35℃
               - Humidity: 30-60 %
               - Atmospheric pressure: 86-106kPa


         1.4. Host System Configuration List and Details
           Manufacturer              Description               Model             Serial Number             Certificate
                   --                      --                      --                     --                      --


         1.5. External I/O Port
                   I/O Port Description                            Quantity                            Cable
                                --                                      --                                 --




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 7 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


         1.6. Description of Test Facility
               FCC Registration Number is 254912.
               Industry Canada Registration Number is 9642A-1.
               EMSD Registration Number is ARCB0108.
               UL Registration Number is 100571-492.
               TUV SUD Registration Number is SCN1081.
               TUV RH Registration Number is UA 50296516-001.
               NVLAP Accreditation Code is 600167-0.
               FCC Designation Number is CN5024.
               CAB identifier: CN0071
         1.7. Statement of The Measurement Uncertainty

               ISO Guide 17025 requires that an estimate of the measurement uncertainties
               associated with the emissions test results be included in the report. The
               measurement uncertainties given below are based on a 95% confidence level and
               were calculated in accordance with NAMAS document NIS 81.
                     Test Item             Frequency Range           Uncertainty         Note
                                             9KHz~30MHz                3.10dB             (1)
                                           30MHz~200MHz                2.96dB             (1)
                Radiation Uncertainty :
                                          200MHz~1000MHz               3.10dB             (1)
                                            1GHz~26.5GHz               3.80dB             (1)
                    Conduction        :     150kHz~30MHz               1.63dB             (1)
                    Uncertainty
                 Power disturbance :       30MHz~300MHz                1.60dB             (1)

               (1). This uncertainty represents an expanded uncertainty expressed at
               approximately the 95% confidence level using a coverage factor of k=2.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 8 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


 2. TEST METHODOLOGY
               All measurements contained in this report were conducted with ANSI C63.10: 2013,
               American National Standard of Procedures for Compliance Testing of Unlicensed
               Wireless Devices.
               The radiated testing was performed at an antenna-to-EUT distance of 3 meters. All
               radiated and conducted emissions measurement was performed at Shenzhen LCS
               Compliance Testing Laboratory Ltd..
         2.1. EUT Configuration
               The EUT configuration for testing is installed on RF field strength measurement to
               meet the Commissions requirement and operating in a manner that intends to
               maximize its emission characteristics in a continuous normal application.


         2.2. EUT Exercise
               The EUT was operated in the normal operating mode. The TX frequency that was
               fixed which was for the purpose of the measurements.
               According to its specifications, the EUT must comply with the requirements of the
               Section 15.203, 15.205, 15.207, 15.209 and 15.231 under the FCC Rules Part 15
               Subpart C and RSS-210.


         2.3. General Test Procedures
              2.3.1 Conducted Emissions(N/A)
               According to the requirements in Section 6.2 of ANSI C63.10: 2013, AC power-line
               conducted emissions shall be measured in the frequency range between 0.15 MHz
               and 30MHz using Quasi-peak and average detector modes.

               2.3.2 Radiated Emissions
               The EUT is placed on a turn table and the turntable shall rotate 360 degrees to
               determine the position of maximum emission level. EUT is set 3m away from the
               receiving antenna, which varied from 1m to 4m to find out the highest emission. And
               also, each emission was to be maximized by changing the polarization of receiving
               antenna both horizontal and vertical. In order to find out the maximum emissions,
               exploratory radiated emission measurements were made according to the
               requirements in Section 6.3 of ANSI C63.10: 2013


         2.4. Instrument Calibration
               All test equipment is regularly checked to ensure that performance is maintained in
               accordance with the manufacturer's specifications. All antennas are calibrated at
               regular intervals with respect to tuned half-wave dipoles. An exhibit of this report
               contains the list of test equipment used and calibration information.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                 Page 9 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




         2.5. Test Mode
               The EUT has been tested under engineering mode. The field strength of radiation
               emission was measured in the following position: EUT stand-up position (Y axis),
               lie-down position (X, Z axis).
               The worst case of Y axis was reported.
               DC 3.0V by CR2032 Battery power to the EUT for testing.

               The EUT transmits signal as soon as it is powered on, and recorded the result in this
               report.

               ***Note: Using a temporary antenna connector for the EUT when conducted
               measurements are performed.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 10 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA



 3. SYSTEM TEST CONFIGURATION


         3.1. Justification

               The system was configured for testing in a continuous transmit condition.

         3.2. EUT Exercise Software

               N/A

         3.3. Special Accessories

               N/A

         3.4. Block Diagram/Schematics

               Please refer to the related document

         3.5. Equipment Modifications

               Shenzhen LCS Compliance Testing Laboratory Ltd. has not done any modification
               on the EUT.

         3.6. Test Setup

               Please refer to the test setup photo.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 11 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


 4. SUMMARY OF TEST RESULTS

                           Applied Standard: FCC Part 15 Subpart C
                 FCC Rules                 Description of Test                                                     Result
                   §15.203                                   Antenna Requirement                                Compliant
                   §15.205                          Restricted Bands Of Operation                               Compliant
                                                  Radiated Emission Limits, General
                   §15.209                                                                                      Compliant
                                                             Requirements.
                                                  Field Strength Of Fundamental And
                 §15.231 (e)                                                                                    Compliant
                                                               Harmonics
                 §15.231 (c)                                20dB Bandwidth                                      Compliant
                                                 Duration of each Transmission and the
                 §15. 231(e)                                                                                    Compliant
                                                              silent period
                   §15.231                                  Duty cycle Factor                                   Compliant
                   §15.207                                   Conducted Emissions                                     N/A




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 12 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


 5. TEST ITEMS AND RESULTS

         5.1. Duration of each Transmission and the silent period

               FCC 15.231 (e)
               5.1.1. Limit
               devices operated under the provisions of this paragraph shall be provided with a means for
               automatically limiting operation so that the duration of each transmission shall not be
               greater than one second and the silent period between transmissions shall be at least 30
               times the duration of the transmission but in no case less than 10 seconds.

               5.1.2. Test Procedure

               Maximizing procedure was performed on the highest emissions to ensure that the
               EUT complied with all installation combinations. The antenna was all opened.

               5.1.3. Test Results
                  Temperature            23.4℃                       Humidity                    53.3%
                  Test Engineer          WangChuang



             Frequency            Duration of each                   Limit: not more than 1
                                 Transmission Time                          seconds                         Conclusion
               (MHz)                     (s)                                   (s)
               433.92                     0.049                                    1                            PASS



             Frequency             the silent period             Limit: At least 30 times the
                                                                 duration of the transmission               Conclusion
               (MHz)                       (s)                   but in no case less than 10s
               433.92                      14.2                                  >10s                           PASS




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 13 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 14 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


            5.2. Transmitter Field Strength of Emissions

               5.2.1. Limit
               FCC §15.231 (e) /15.209

               In addition to the provisions of § 15.205, the field strength of emissions from
               Intentional radiators operated under this section shall not exceed the following:
                        Fundamental                       Field Strength of                   Field Strength of spurious
                         frequency                          Fundamental                               emissions
                           (MHz)                          (microvolt/meter)                        (microvolt/meter)
                         40.66-40.70                            1,000                                       100
                           70-130                                500                                         50
                          130-174                            500 to 1,500                                 50 to 150
                          174-260                               1,500                                       150
                          260-470                           1,500 to 5,000                               150 to 500
                         Above 470                              5,000                                       500

               [Where F is the frequency in MHz, the formulas for calculating the maximum
               permitted fundamental field strengths are as follows: for the band 260-470 MHz,
               µV/m at 3 meters = 16.66667(F) - 2833.333. The maximum permitted unwanted
               emission level is 20 dB below the maximum permitted fundamental level.]
               §15.205 (a) Except as shown in paragraph (d) of this section, only spurious
               emissions are permitted in any of the frequency bands listed below:




               1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
               2 Above 38.6
               §15.205 (b) Except as provided in paragraphs (d) and (e), the field strength of
               emissions appearing within these frequency bands shall not exceed the limits shown
               in Section 15.209. At frequencies equal to or less than 1000 MHz, compliance with
               the limits in Section 15.209 shall be demonstrated using measurement
               instrumentation employing a CISPR quasi peak detector. Above 1000 MHz,
               compliance with the emission limits in Section 15.209 shall be demonstrated based
               on the average value of the measured emissions. The provisions in Section 15.35
               apply to these measurements.


  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 15 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA

               §15.209 (a) Except as provided elsewhere in this Subpart, the emissions from an
               intentional radiator shall not exceed the field strength levels specified in the following
               table:




               ** Except as provided in paragraph (g), fundamental emissions from intentional
               radiators operating under this Section shall not be located in the frequency bands 54
               72 MHz, 76 88 MHz, 174 216 MHz or 470 806 MHz. However, operation within these
               frequency bands is permitted under other sections of this Part, e.g., Sections 15.231
               and 15.241.
               §15.209 (b) In the emission table above, the tighter limit applies at the band edges.


               5.2.2. Instruments Setting
               The following table is the setting of spectrum analyzer and receiver.
                Spectrum Parameter                     Setting
                 Attenuation                                           Auto
                 Start Frequency                                       1000 MHz
                 Stop Frequency                                        10th carrier harmonic
                 RB / VB (Emission in restricted band)                 1MHz / 1MHz for Peak, 1 MHz / 10Hz for Average
                 RB / VB (Emission in non-restricted band)             1MHz / 1MHz for Peak, 1 MHz / 10Hz for Average


                 Spectrum Parameter                                    Setting
                 Attenuation                                           Auto
                 Start ~ Stop Frequency                                9kHz~150kHz / RB 200Hz for QP
                 Start ~ Stop Frequency                                150kHz~30MHz / RB 9kHz for QP
                 Start ~ Stop Frequency                                30MHz~1000MHz / RB 120kHz for QP




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 16 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




               5.2.3. Test Procedures
               1) Sequence of testing 9 kHz to 30 MHz
               Setup:
               --- The equipment was set up to simulate a typical usage like described in the user
               manual or described by manufacturer.
               --- If the EUT is a tabletop system, a rotatable table with 0.8 m height is used.
               --- If the EUT is a floor standing device, it is placed on the ground.
               --- Auxiliary equipment and cables were positioned to simulate normal operation
               conditions.
               --- The AC power port of the EUT (if available) is connected to a power outlet below
               the turntable.
               --- The measurement distance is 3 meter.
               --- The EUT was set into operation.
               Premeasurement:
               --- The turntable rotates from 0°to 315°using 45°steps.
               --- The antenna height is 1.5 meter.
               --- At each turntable position the analyzer sweeps with peak detection to find the
               maximum of all emissions
               Final measurement:
               --- Identified emissions during the premeasurement the software maximizes by
               rotating the turntable position (0°to 360°) and by rotating the elevation axes (0°to
               360°).
               --- The final measurement will be done in the position (turntable and elevation)
               causing the highest emissions with QPK detector.
               --- The final levels, frequency, measuring time, bandwidth, turntable position,
               correction factor, margin to the limit and limit will be recorded. Also a plot with the
               graph of the premeasurement and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 17 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




               2) Sequence of testing 30 MHz to 1 GHz
               Setup:
               --- The equipment was set up to simulate a typical usage like described in the user
               manual or described by manufacturer.
               --- If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed
               on the ground plane.
               --- If the EUT is a floor standing device, it is placed on the ground plane with
               insulation between both.
               --- Auxiliary equipment and cables were positioned to simulate normal operation
               conditions.
               --- The AC power port of the EUT (if available) is connected to a power outlet below
               the turntable.
               --- The measurement distance is 3 meter.
               --- The EUT was set into operation.
               Premeasurement:
               --- The turntable rotates from 0°to 315°using 45°steps.
               --- The antenna is polarized vertical and horizontal.
               --- The antenna height changes from 1 to 3 meter.
               --- At each turntable position, antenna polarization and height the analyzer sweeps
               three times in peak to find the maximum of all emissions.
               Final measurement:
               --- The final measurement will be performed with minimum the six highest peaks.
               --- According to the maximum antenna and turntable positions of premeasurement
               the software maximize the peaks by changing turntable position (± 45°) and antenna
               movement between 1 and 4 meter.
               --- The final measurement will be done with QP detector with an EMI receiver.
               --- The final levels, frequency, measuring time, bandwidth, antenna height, antenna
               polarization, turntable angle, correction factor, margin to the limit and limit will be
               recorded. Also a plot with the graph of the premeasurement with marked maximum
               final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 18 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




               3) Sequence of testing 1 GHz to 12.75 GHz
               Setup:
               --- The equipment was set up to simulate a typical usage like described in the user
               manual or described by manufacturer.
               --- If the EUT is a tabletop system, a rotatable table with 1.5 m height is used.
               --- If the EUT is a floor standing device, it is placed on the ground plane with
               insulation between both.
               --- Auxiliary equipment and cables were positioned to simulate normal operation
               conditions.
               --- The AC power port of the EUT (if available) is connected to a power outlet below
               the turntable.
               --- The measurement distance is 3 meter.
               --- The EUT was set into operation.
               Premeasurement:
               --- The turntable rotates from 0°to 315°using 45°steps.
               --- The antenna is polarized vertical and horizontal.
               --- The antenna height is 1.5 meter.
               --- At each turntable position and antenna polarization the analyzer sweeps with
               peak detection to find the maximum of all emissions.
               Final measurement:
               --- The final measurement will be performed with minimum the six highest peaks.
               --- According to the maximum found antenna polarisation and turntable position of
               the premeasurement the software maximizes the peaks by rotating the turntable
               position (0°to 360°). This measurement is repeated for different EUT-table positions
               (0°to 150°in 30°-steps). This procedure is repeated for both antenna polarisations.
               --- The final measurement will be done in the position (turntable, EUT-table and
               antenna polarization) causing the highest emissions with Peak and RMS detector.
               --- The final levels, frequency, measuring time, bandwidth, turntable position,
               EUT-table position, antenna polarization, correction factor, margin to the limit and
               limit will be recorded. Also a plot with the graph of the premeasurement with marked
               maximum final measurements and the limit will be stored.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 19 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA


               5.2.4. Test Setup Layout




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 20 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




               5.2.5. EUT Operation during Test
               The EUT was programmed to be in continuously transmitting mode.


               5.2.6. Results of Radiated Emissions (9kHz~30MHz)
               The low frequency, which started from 9KHz to 30MHz, was pre-scan and the result
               was 20dB lower than the limit line per 15.31(o) was not reported.
               Note: Distance extrapolation factor = 40 log (specific distance / test distance) (dB);
               Limit line = specific limits (dBuV) + distance extrapolation factor.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 21 of 30


s#evenien ues compuraiice TesTine LaporaToRy LTo.                     reo ipoasuo.msrue            Repore No.sLCS1901071661EA

                   5.2.7. Results of Radiated Emissions (30MHz~1GHz)

                        Temporature          2420                   Humidity                  58.4%

                        Test Engineer        WangGhuang             Pol                       Horizontal
                         Test Mode           Tx

Honzontal
              oLevel(aBuvim)
                                                                                              s
              zo
              co                                                                                          rcclotasss
              so
              «o
              so
              20
              10
                   5o           so                   100                                          5oo               T00
    Env. /zns:                            2a.20C/s0.as
    por:                                  wonzzonsaz
                         Freq    Reading          Cabtes   Antfse Messured               Limit          Over     Remark
                        nixe          apuy           as    dB/m           dBuy/m        dBut/m       ds
          1          s.s2             5.75          ouss   slsz            i7.a0        ~a0.00     2220            or
          2          a9.ae           ~o.44          o.er    ad.ar          as.ge         as.s0     —30.22          ce
          3          ers.02          —0.42          ols    11.07           i1183        a6.00      —30.47          ce
          a          2sz.os           0.71          n0r     arlor          asl.es        46.00     —31.37          ce
          s         a99.92           sa.so          nas    as.ss           Ti.er        a6.00       25.21          resk
          s         zi9.20            1276          i7s    as.os           mr.se        a6.00      —23.44          ce
     mote: 1. All readings are Quasi—pesk velues.
     2. Messured= Reading + Antenns Factor + Cable Loss
     3. the emission that are 20db below the official limit are not reported


                                                           Fundamental Peak Result

      Freq;enc                       Peak Level                      Limit(dBpV/im                  Maré;)ln(d Conclusi
       (MHz)                          (dBuVim)                         {average}                                  on
        4393.92                         71.21                               92.86                       —21.65      PASS


                                                           Harmonics Average Result
                                                  AV                                m               Margin(d
      Frequenc|             Peak        Factor(dBuV/im)       Average           Limit(dBuV/               B)      |Conslusi
              Y             Level         {see Section          Level                   m)                           on
        (MHz)             |(dBuV/im)              5.4)       (dBuV/im)              {average)
        433.02              71.21               —6.189          65.021                72.86             —7.839      PASS



   This reportsthall not be reproduced exceptinful, vithouthe wrizen approvalofsherahen Lics Compliance Testng Laboratory Lad.
                                                             Fage22 of 30


s#evenen tos comptance resrvc ragoratory Lo                         CC 10 —249KB—WSTHE       Repon Nest.csi9olori¢6sEA


                       Temperature           2420                 Humidty                sa.4%
                      Test Engineer          WangChuang           Pol                    Verical
                        Test Mode            Tx
Vertical
            poLevel (dBuvim
            zo
            so
                                                                                                        recaukss.a
            so
            ao
            so
            20
            10
                 5o            5o                   100           200                         5oo                  1000
                                                         Frequency @tit2)
  Bnv./ins:                                  24.2°0/s3 .48
  pors:                                      vernrcan
                      rreq      Reading          Cabtos    Antfsc       Measured     Limit          Over    Remark
                       mite          aBuv          as      48/m         dBu¥/m      dBu¥/m           dB
       1           selar            <ou%0         o.45     a2.90         12.s9       «0.00         <ardi       oor
       20         a0s.2r             —o.a3        ols      ar.an         i2.9e       a3.50         —30.s4      or
       3           remes            —o.82         o.8a     10.57         10.s9       a3.50         —am.91      or
       4          so3.sa             —0.08        m03       ao.ir        r4.06      a6.00          —31.94      or
       s          ass.gr            so.6a         nas       as.ss        26.3a      46.00           30.34      Pesk
       60         Tes.36             1.27         azo      as.ae         er.as      a6.00          —23.35      or
   Note: 1. All reedings are Quasi—peak valucs.
   2. Meesured= Resding + Antenna Factor + Cable Loss
   3. The emission that are 20db below the official limit are not reported
                                                           Fundamental Peak Result

       Frsq;snc                      Peak Level                     Limit{dBpV/m)            Margin(d| Conclusi
        (MHz)                         (dBp¥/im)                       {average)                  B)       on
           499.92                       7634                             92.86                 —16.52        Pass


                                                           Harmonics Average Result
                                             AV                              ho
       Frequenc}              Peak     Factor(dBpV/m)         Average       Limk(dBpV/ Margin(d] Conclusi
             Y            Level          {see Section           Level           m)                 B)         on
           (MHz)         |(dBp¥/m)           5.4)             (dBpV/m)       {average)
           433.02         76.34                £.189           70.151            72.06         —2.709        PaASs



   This mpon shallnai be repredued exceptfal, wihout the witen orproval ofShanchen LCS Conplance Tesing Laboraiory Li
                                                       Page2sef 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




               5.2.8. Results of Radiated Emissions (1-5GHz)


            Temperature              24.3℃                           Humidity                       53.3%
            Test Engineer            WangChuang                      Test Mode                      Tx




      Peak Value:
        Frequency                      Level                    Limit Line                  Margin
                                                                                                               Polarization
          (MHz)                      (dBuV/m)                   (dBuV/m)                   (dBuV/m)
         1301.76                       48.07                       74                        -25.93             Horizontal
         1735.68                       48.63                       74                        -25.37             Horizontal
         2169.60                       44.77                       74                        -29.23             Horizontal
         1301.76                       41.67                       74                        -32.33              Vertical
         1735.68                       41.05                       74                        -32.95              Vertical
         2169.60                       41.09                       74                        -32.91              Vertical


 Average Value:
                                                             Average            Limit
 Frequency   Level                    Duty cycle                                                  Margin
                                                              value             Line                                 Polarization
   (MHz)   (dBuV/m)                     factor                                                   (dBuV/m)
                                                            (dBuV/m)          (dBuV/m)
   1301.76            48.07              -6.189              41.881              54                -12.119            Horizontal
   1735.68            48.63              -6.189              42.441              54                -11.559            Horizontal
   2169.60            44.77              -6.189              38.581              54                -15.419            Horizontal
   1301.76            41.67              -6.189              35.481              54                -18.519             Vertical
   1735.68            41.05              -6.189              34.861              54                -19.139             Vertical
   2169.60            41.09              -6.189              34.901              54                -19.099             Vertical
        1. Measuring frequencies from 9k~10th harmonic (ex. 5GHz), No emission found between lowest
            internal used/generated frequency to 30MHz.
        2. Radiated emissions measured in frequency range from 9k~10th harmonic (ex. 5GHz) were
            made with an instrument using Peak detector mode.
        3. Data of measurement within this frequency range shown “ --- ” in the table above means the
           reading of emissions are attenuated more than 20dB below the permissible limits or the field
           strength is too small to be measured.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 24 of 30


SHENZHEN LCS COMPLIANCE TESTING IABORATORY LTD.                                                     ECC ID:2ASHB—WSTHE                    Report No.: LCS190107166AEA




         5.3. 20dB Bandwidth Emissions

               FCC 15.231 (c)
               5.3.1. Limit
               The bandwidth of the emission shall be no wider than 0.25% of the center frequency
               for devices operating above 70 MHz and below 900 MHz. Bandwidth is determined
               at the points 20 dB down from the modulated carrier.

               5.3.2. Test Procedure
               With the EUT‘s antenna attached, the EUT‘s 200B Bandwidth power was received
               by the test antenna which was connected to the spectrum analyzer with the START
               and STOP frequencies set to the EUT‘s operation band.

               5.3.3. Test Data
            Temperature                          24.3°C                                           Humidity                                53.3%
           Test Engineer                         WangChuang                                       Test Mode                               Tx



             Transmit Frequency                                                      Limit                   200B Bandwidth                                 Result
                                                                                                                                                             esu
                          (MHz)                                                      (kHz)                             (kH2)

                         433.92                                                     1085.00                           79.78                                 PASS
          .                  .                                         BJ0.25% of the centre operating frequency
       Maximum allowed bandwidth:                                                                 .
                                                                       [0.5% of the centre operating frequency
                       RBW:                                            10kHz 100kHz Dother kHz
                       VBW:                                            B30kHz [1300kHz Llother kHz
               [Bk: KosightSpectrum Analyee— Occupied SW                                                                                               To o es
                           I     i       on       ac |             I           |_    sensena          1   aucn auto   1134031 AAeris, 2019
                Ref Value 0.00 dBm                                          Genter Freg: 433.920000 MHz               Radio Std: None              Amptdiy Scale
                                                                        cz3 Trig: FreeRun          Avglold:>1010
                                                           #lEGainLow       #Atten: 10 dB                             Radio Device: BTS                 Ref Value

                                                                                                                                                         0.00 dBm
                o dBraiv           Ref 0.00 dBm
                Log
                100                                                                                                                                 Attenuation
                20                                                                                                                                       F10 aB)
                0
                00                                                                   / \
                                                                                        W                                                               Scale/Div
                me                                                                                                                                         10. as
                |soo                                                                        \"L
                lroo                                         uen3                                           m
                |soo

                |so


                Center 433.9 MHz                                                                                          Span 1 MHzI
                 Res BW 10 kHz                                                      #VBW 30 kHz                         Sweep 9.6 ms

                   Occupied Bandwidth                                                  Total Power              —24.8 dBm                      |

                                                    73.713 kHz
                  Transmit Freq Error                          5.193 kHz               OBW Power                   99.00 %
                  x dB Bandwidth                               79.78 kHz               x dB                     —20.00 dB
                                                                                                                                                            More
                                                                                                                                                             1 of2




  This report shall not be reproduced exceptinfull, withoutthe written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                             Page 25 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




         5.4. Duty cycle

               5.4.1. Limit
               No dedicated limit specified in the Rules.
               5.4.2. Test Procedure
               5.4.2.1. Place the EUT on the table and set it in transmitting mode.
               5.4.2.2. Remove the antenna from the EUT and then connect a low loss RF cable
               from the antenna port to the spectrum analyzer.
               5.4.2.3. Set centre frequency of spectrum analyzer=operating frequency.
               5.4.2.4. Set the spectrum analyzer as RBW=100kHz, VBW=100KHz, Span=0Hz,
               Adjust Sweep=100ms to obtain the “worst-case” pulse on time.
               5.4.2.5. Repeat above procedures until all frequency measured was complete.
               5.4.3. Test Data
               Ton = 49.04 (ms)
               Tp = 100 (ms)
               The duty cycle= 49.04 /100 = 49.04%
               Average Correction Factory = 20*log (Ton/Tp) =20*log (0.4904) = -6.189 dB

               Note: The signal bandwidth was measured and less then 100kHz RBW so PDCF
               factor is not required to correct the fundamental signal peak result.




                                                          Tp = 49.04(ms)




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 26 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 27 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA




         5.5. Antenna Requirement

               FCC 15.203
               5.5.1. Standard Applicable

               According to § 15.203 & RSS-Gen, An intentional radiator shall be designed to
               ensure that no antenna other than that furnished by the responsible party shall be
               used with the device. The use of a permanently attached antenna or of an antenna
               that uses a unique coupling to the intentional radiator shall be considered sufficient
               to comply with the provisions of this section.


               5.5.2. Result
               Compliant.
               The antenna used for transmitting is permanently attached and no consideration of
               replacement. Please see EUT photo for details.




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 28 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                            FCC ID:2ASHB-WSTHE             Report No.:LCS190107166AEA



 6. LIST OF MEASURING EQUIPMENTS
Item                 Equipment                   Manufacturer          Model No.             Serial No.          Cal Date        Due Date
 1             MXA Signal Analyzer                  Agilent             N9020A             MY49100060           2018-11-15      2019-11-14
 2              DC Power Supply                    Agilent              E3642A                  N/A             2018-11-15      2019-11-14
             Temperature & Humidity             GUANGZHOU
 3                                                                      GDS-100                70932            2018-10-10      2019-10-09
                   Chamber                       GOGNWEN
 4             EMI Test Software                  AUDIX                    E3                     /                  /               /
                                                    SIDT
 5          3m Semi Anechoic Chamber                                    SAC-3M             03CH03-HY            2018-06-16      2019-06-15
                                                FRANKONIA
 6             Positioning Controller                MF                 MF-7082                   /             2018-06-16      2019-06-15
 7             Active Loop Antenna            SCHWARZBECK            FMZB 1519B                00005            2018-07-26      2019-07-25
 8                By-log Antenna              SCHWARZBECK             VULB9163               9163-470           2018-07-26      2019-07-25
 9                 Horn Antenna               SCHWARZBECK            BBHA 9120D             9120D-1925          2018-07-02      2019-07-01
10               EMI Test Receiver                   R&S                 ESR 7                101181            2018-06-16      2019-06-15
11         RS SPECTRUM ANALYZER                      R&S                 FSP40                100503            2018-11-15      2019-11-14
12                 AMPLIFIER                       QuieTek                QTK             CHM/0809065           2018-11-15      2019-11-14
13                RF Cable-R03m                     Jye Bao   RG142          CB021                              2018-06-16      2019-06-15
                                                            SUCOFLEX
 14             RF Cable-HIGH                 SUHNER                       03CH03-HY                            2018-06-16      2019-06-15
                                                               106
Note: All equipment is calibrated through GUANGZHOU LISAI CALIBRATION AND TEST CO.,LTD.




     This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                   Page 29 of 30


SHENZHEN LCS COMPLIANCE TESTING LABORATORY LTD.                         FCC ID:2ASHB-WSTHE            Report No.:LCS190107166AEA

7. TEST SETUP PHOTOGRAPHS OF EUT

   Please refer to separated files for Test Setup Photos of the EUT.


8. EXTERIOR PHOTOGRAPHS OF THE EUT

   Please refer to separated files for External Photos of the EUT.


9. INTERIOR PHOTOGRAPHS OF THE EUT

   Please refer to separated files for Internal Photos of the EUT.




                           ----------------THE END OF REPORT---------------




  This report shall not be reproduced except in full, without the written approval of Shenzhen LCS Compliance Testing Laboratory Ltd..
                                                                Page 30 of 30



Document Created: 2019-04-23 08:48:11
Document Modified: 2019-04-23 08:48:11

© 2024 FCC.report