Test report

FCC ID: 2ASBE-DEV00106

Test Report

Download: PDF
FCCID_4196702

                                                                                     Report No.: ATE20190037
                                                                                                  Page 1 of 22




                           APPLICATION CERTIFICATION FCC Part 15C
                                        On Behalf of
                                        Ectosense NV

                                       Airpatch Charger
                                      Model No.: DEV00106

                                    FCC ID: 2ASBE-DEV00106




            Prepared for        :   Ectosense NV
            Address             :   Bosbessenlaan 19a, Rotselaar, 3110 Belgium

            Prepared by         :   Shenzhen Accurate Technology Co., Ltd.
            Address             :   1/F., Building A, Changyuan New Material Port, Science &
                                    Industry Park, Nanshan District, Shenzhen, Guangdong, P.R.
                                    China

                                    Tel: +86-755-26503290
                                    Fax: +86-755-26503396




            Report No.          :   ATE20190037
            Date of Test        :   January 14-January 16, 2019
            Date of Report      :   January 18, 2019




FCC ID: 2ASBE-DEV00106                                                     Shenzhen Accurate Technology Co., Ltd


                                                                                                                                         Report No.: ATE20190037
                                                                                                                                                      Page 2 of 22


                                                             TABLE OF CONTENTS

    Description                                                                                                                                                    Page


    Test Report Declaration
     1.      TEST RESULTS SUMMARY ......................................................................................................... 4
     2.      GENERAL INFORMATION .......................................................................................................... 5
          2.1.     Description of Device (EUT)....................................................................................................................5
          2.2.     Test Mode .................................................................................................................................................5
          2.3.     Special Accessory and Auxiliary Equipment ...........................................................................................5
          2.4.     Description of Test Facility ......................................................................................................................6
          2.5.     Measurement Uncertainty.........................................................................................................................6
     3.      MEASURING DEVICE AND TEST EQUIPMENT ..................................................................... 7
          3.1.     The Equipment Used to Measure Conducted Disturbance .......................................................................7
          3.2.     The Equipment Used to Measure Radiated Emission...............................................................................7
     4.      AC POWER LINE CONDUCTED MEASUREMENT................................................................. 8
          4.1.     Block Diagram of Test Setup....................................................................................................................8
          4.2.     AC Power Line Conducted Emission Measurement Limits .....................................................................8
          4.3.     Configuration of EUT on Measurement ...................................................................................................8
          4.4.     Operating Condition of EUT ....................................................................................................................8
          4.5.     Measurement Procedure ...........................................................................................................................9
          4.6.     Data Sample..............................................................................................................................................9
          4.7.     Measurement Results................................................................................................................................9
     5.      RADIATED EMISSION MEASUREMENT................................................................................ 14
          5.1.     Block Diagram of Test............................................................................................................................14
          5.2.     Radiated Emission Limit ........................................................................................................................15
          5.3.     EUT Configuration on Measurement .....................................................................................................15
          5.4.     Operating Condition of EUT ..................................................................................................................15
          5.5.     Measurement Procedure .........................................................................................................................15
          5.6.     Data Sample............................................................................................................................................16
          5.7.     Measurement Result ...............................................................................................................................16
     6.      ANTENNA REQUIREMENT........................................................................................................ 22
          6.1.     The Requirement ....................................................................................................................................22
          6.2.     Antenna Construction .............................................................................................................................22




FCC ID: 2ASBE-DEV00106                                                                                                      Shenzhen Accurate Technology Co., Ltd


                                                                                        Report No.: ATE20190037
                                                                                                     Page 3 of 22


                                       Test Report Declaration
             Applicant          :   Ectosense NV
             Address            :   Bosbessenlaan 19a, Rotselaar, 3110 Belgium

             Manufacturer       :   Ectosense NV
             Address            :   Bosbessenlaan 19a, Rotselaar, 3110 Belgium

             Product            :   Airpatch Charger
             Model No.          :   DEV00106
             Trade Mark         :   NightOwl

             Measurement Procedure Used:

             FCC CFR47 Part 18 Subpart C Section 18.305 and 18.307
             ANSI C63.10: 2013

             The device described above is tested by Shenzhen Accurate Technology Co., Ltd. to determine
             the maximum emission levels emanating from the device. The maximum emission levels are
             compared to the FCC Part 18 Subpart C limits both radiated and conducted emissions. The
             measurement results are contained in this test report and Shenzhen Accurate Technology Co.,
             Ltd. is assumed full responsibility for the accuracy and completeness of these measurements.
             Also, this report shows that the Equipment Under Test (EUT) is to be technically compliant with
             the FCC requirements.

             This report applies to above tested sample only. This report shall not be reproduced in part
             without written approval of Shenzhen Accurate Technology Co., Ltd.


             Date of Test :                             January 14-January 16, 2019
             Date of Report :                                January 18, 2019



             Prepared by :
                                                           (Star Yang, Engineer)




             Approved & Authorized Signer :
                                                            (Sean Liu, Manager)




FCC ID: 2ASBE-DEV00106                                                        Shenzhen Accurate Technology Co., Ltd


                                                                               Report No.: ATE20190037
                                                                                            Page 4 of 22



          1. TEST RESULTS SUMMARY

                Test Items                           Test Standard                    Test Results
                AC Power Line Conducted Emission   FCC Part 18.307(b)                      Pass
                Radiated Emission                  FCC Part 18.305(b)                      Pass




FCC ID: 2ASBE-DEV00106                                               Shenzhen Accurate Technology Co., Ltd


                                                                                             Report No.: ATE20190037
                                                                                                          Page 5 of 22



          2. GENERAL INFORMATION


                 2.1.Description of Device (EUT)

                         Product                       :    Airpatch Charger
                         Model No.                     :    DEV00106
                         Frequency                     :    110-205KHz
                         Modulation Type               :    ASK
                         Type of Antenna               :    Induction coil
                         AC Adapter Rating             :    Model: SWN6-5-NH-I38
                                                            Input: 100-240Vac, 0.6-0.3A, 50-60Hz
                                                            Output: 5V 1.2A


                 2.2.Test Mode

                         Test Item                         EMI Test Modes
                         Conducted Emission                Max. Power Output
                         Radiated Emission                 Max. Power Output


                 2.3.Special Accessory and Auxiliary Equipment

                             Description          Manufacturer            Model                    S/N
                            Airpatch Sensor       Ectosense NV           DEV00093                  N/A

                         Note: Wireless charger load is provided by manufacturer




FCC ID: 2ASBE-DEV00106                                                             Shenzhen Accurate Technology Co., Ltd


                                                                                        Report No.: ATE20190037
                                                                                                     Page 6 of 22



                 2.4.Description of Test Facility
                    EMC Lab           :   Recognition of accreditation by Federal Communications
                                          Commission (FCC)
                                          The Designation Number is CN1189
                                          The Registration Number is 708358

                                          Listed by Innovation, Science and Economic Development
                                          Canada (ISEDC)
                                          The Registration Number is 5077A-2

                                          Accredited by China National Accreditation Service for
                                          Conformity Assessment (CNAS)
                                          The Registration Number is CNAS L3193

                                          Accredited by American Association for Laboratory
                                          Accreditation (A2LA)
                                          The Certificate Number is 4297.01

                    Name of Firm      :   Shenzhen Accurate Technology Co., Ltd
                    Site Location     :   1/F., Building A, Changyuan New Material Port, Science &
                                          Industry Park, Nanshan District, Shenzhen, Guangdong, P.R.
                                          China



                 2.5.Measurement Uncertainty
                    Conducted emission expanded uncertainty         :   U=2.23dB, k=2

                    Radiated emission expanded uncertainty          :   U=3.08dB, k=2
                    (9kHz-30MHz)
                    Radiated emission expanded uncertainty          :   U=4.42dB, k=2
                    (30MHz-1000MHz)
                    Radiated emission expanded uncertainty          :   U=4.06dB, k=2
                    (Above 1GHz)




FCC ID: 2ASBE-DEV00106                                                        Shenzhen Accurate Technology Co., Ltd


                                                                              Report No.: ATE20190037
                                                                                           Page 7 of 22



          3. MEASURING DEVICE AND TEST EQUIPMENT

            3.1. The Equipment Used to Measure Conducted Disturbance
Item Equipment           Manufacturer      Model No.   Serial No.   Last Cal.              Cal.
                                                                                           Interval
  1. Test Receiver    Rohde & Schwarz      ESCS30      100307       Jan.05, 2019           1 Year
  2. L.I.S.N.         Schwarzbeck          NLSK8126    8126431      Jan.05, 2019           1 Year
  3. Pulse Limiter    Rohde & Schwarz      ESH3-Z2     100305       Jan.05, 2019           1 Year
     50Ω Coaxial      Anritsu Corp         MP59B       6200283936   Jan.05, 2019           1 Year
  4.
     Switch
  5. RF Coaxial Cable SUHNER               N-2m        No.2         Jan.05, 2019           1 Year
  6. Measurement Software: ES-K1 V1.71

            3.2. The Equipment Used to Measure Radiated Emission
Item Equipment            Manufacturer     Model No.   Serial No.   Last Cal.              Cal.
                                                                                           Interval
  1. Spectrum Analyzer    Rohde&Schwarz    FSV40       101495       Jan.05, 2019           1 Year
  2. Test Receiver        Rohde& Schwarz   ESR         101817       Jan.05, 2019           1 Year
  3. Bilog Antenna        Schwarzbeck      VULB9163    9163-323     Jan.05, 2019           1 Year
  4. Loop Antenna         Schwarzbeck      FMZB1516    1516131      Jan.05, 2019           1 Year
  5. Horn Antenna         Schwarzbeck      BBHA9120D   9120D-655    Jan.05, 2019           1 Year
  6. Horn Antenna         Schwarzbeck      BBHA9170    9170-359     Jan.05, 2019           1 Year
  7. RF Switching         Compliance       RSU-M2      38322        Jan.05, 2019           1 Year
     Unit+PreAMP          Direction
  8. Pre-Amplifier        Agilent          8447D       294A10619    Jan.05, 2019           1 Year
  9. Pre-Amplifier        Rohde&Schwarz    CBLU11835   3791         Jan.05, 2019           1 Year
                                           40-01
 10.   50 Coaxial Switch Anritsu Corp      MP59B       6200506474   Jan.05, 2019           1 Year
 11.   RF Coaxial Cable   RESENBERGER N-12m            No.11        Jan.05, 2019           1 Year
 12.   RF Coaxial Cable   RESENBERGER N-0.5m           No.12        Jan.05, 2019           1 Year
 13.   RF Coaxial Cable   SUHNER           N-2m        No.13        Jan.05, 2019           1 Year
 14.   RF Coaxial Cable   SUHNER           N-0.5m      No.15        Jan.05, 2019           1 Year
 15.   RF Coaxial Cable   SUHNER           N-2m        No.16        Jan.05, 2019           1 Year
 16.   RF Coaxial Cable   RESENBERGER N-6m             No.17        Jan.05, 2019           1 Year
 17.   Measurement Software: EZ_EMC V1.1.4.2




FCC ID: 2ASBE-DEV00106                                              Shenzhen Accurate Technology Co., Ltd


                                                                                              Report No.: ATE20190037
                                                                                                           Page 8 of 22



          4. AC POWER LINE CONDUCTED MEASUREMENT


                 4.1.Block Diagram of Test Setup

                                        Test Receiver
                    AC Mains


                                             L.I.S.N          Adapter                   LOAD

                                                                                          EUT


                 4.2.AC Power Line Conducted Emission Measurement Limits
                                Frequency                                   Limit dB(V)
                                  (MHz)                    Quasi-peak Level                Average Level
                             0.15 - 0.50                     66.0 – 56.0 *                 56.0 – 46.0 *
                             0.50 - 5.00                          56.0                         46.0
                             5.00 - 30.00                         60.0                         50.0
                         NOTE1: The lower limit shall apply at the transition frequencies.
                         NOTE2: The limit decreases linearly with the logarithm of the frequency in the range
                                 0.15MHz to 0.50MHz.


                 4.3.Configuration of EUT on Measurement
                         The equipments are installed on conducted emission measurement to meet the
                         commission requirement and operating regulations in a manner, which tends to maximize
                         its emission characteristics in a normal application.


                 4.4.Operating Condition of EUT
                            4.4.1. Setup the EUT and simulator as shown as Section 4.1.

                            4.4.2. Turn on the power of all equipment.

                            4.4.3. Let the EUT work in test mode and measure it.




FCC ID: 2ASBE-DEV00106                                                              Shenzhen Accurate Technology Co., Ltd


                                                                                               Report No.: ATE20190037
                                                                                                            Page 9 of 22



                  4.5.Measurement Procedure
                          The EUT is put on the plane 0.8 m high above the ground by insulating support and is
                          connected to the power mains through a line impedance stabilization network (L.I.S.N.).
                          This provides a 50ohm coupling impedance for the EUT system. Please refer the block
                          diagram of the test setup and photographs. Both sides of AC lines are checked to find out
                          the maximum conducted emission. In order to find the maximum emission levels, the
                          relative positions of equipment and all of the interface cables shall be changed according
                          to ANSI C63.10: 2013 on Conducted Emission Measurement.

                          The bandwidth of test receiver (R & S ESCS30) is set at 9kHz.

                          The frequency range from 150kHz to 30MHz is checked.


                  4.6.Data Sample
Frequency     Transducer          QuasiPeak   Average   QuasiPeak   Average    QuasiPeak     Average          Remark
  (MHz)         value               Level      Level      Limit      Limit      Margin       Margin          (Pass/Fail)
                 (dB)              (dBV)     (dBV)     (dBV)     (dBV)       (dB)         (dB)
 X.XX            10.6                25.3       17.0       59.0       49.0       33.7         32.0               Pass

                          Transducer value = Insertion loss of LISN + Cable Loss
                          Result = Quasi-peak Level/Average Level + Transducer value
                          Limit = Limit stated in standard

                          Calculation Formula:

                          Margin = Limit – Reading level value – Transducer value


                  4.7.Measurement Results
                          Pass.

                          The frequency range from 150kHz to 30MHz is checked.

                          Emissions attenuated more than 20 dB below the permissible value are not reported.

                          The spectral diagrams are attached as below.




 FCC ID: 2ASBE-DEV00106                                                              Shenzhen Accurate Technology Co., Ltd


                                   Report No.: ATE20190037
                                                Page 10 of 22




FCC ID: 2ASBE-DEV00106   Shenzhen Accurate Technology Co., Ltd


                                   Report No.: ATE20190037
                                                Page 11 of 22




FCC ID: 2ASBE-DEV00106   Shenzhen Accurate Technology Co., Ltd


                                   Report No.: ATE20190037
                                                Page 12 of 22




FCC ID: 2ASBE-DEV00106   Shenzhen Accurate Technology Co., Ltd


ACCURATE TECHNOLOGY CO.,LTD

CONDUCTED EMISSION STANDARD FCC PART 18 C

EUT:                                     Airpatch Charger M/N:DEVOO106
Manufacturer:                            Ectosense NV
Operating Condition:                     Max. Power Output
Test Site:                               1#¥Shielding Roon
Operator:                                Frank
Test Specification:                      L    120V/60Hz
Comment:                                 Report NO.:ATE20190037
Start of Test:                           2019—1—14 / 10:02:;15MM


SCAN TABLE: "V       S9K—30MHz fin"
  Short Description:             _SUB_STD_VTERMZ 1.70
  Start                     Stop             Step            Detector Meas.                     1             Transducer
  Frequency                 Frequency        Width                    Time                      Bandw.
  9.0 kiz                   150.0 kHz        100.0 Hz       QuasiPeak 1.0 s                     200 Hz        NSLKS126 2008
                                                            Average
  150.0 kEz                 30.0 MBz          5.0 kHz       QuasiPeak 1.0 s                     9 kEz         NSLK8126 2008
                                                            Average


  Level [dBpV)
                                                   g__




                                                                               g!—




                                                                                                       ol _

                                                                                                              sl—




                                                                                                                       Sl—
 o
     150k                 200k 400k      600k_ 800k 1
                                                                    t
                                                                     =


                                                                               &

                                                                                           &
                                                                                           5
                                                                                           a
                                                                                           5
                                                                                           a
                                                                                           &

                                                                                                       5

                                                                                                              =




                                                                                                                       s
                                                                                                                       =
                                                                                                                              &
                                                                                                                              8
                                                                                                                              5
                                                                 Frequency [H2]
            m m n m n y




MEASUREMENT RESULT:                           "FP—1198—4_fin"

 2019—1—14 10:05AM
   Frequency   Level                         Transd      Limit    Margin             Detector     Line         PE
         MEz    dBuV                             ds       dBuv        dB

      0.340018                  39.20          10.6         59          20.0         P            L1          GND
      0. 670245                 41.90          10.8         56          14.1         P            L1          GND
      0.941021                  41.00          10.8         56          15.0         9P           L1          GND
      4.932760                  41 .50         11.2         56          14.5         P            L1          GND
      5.300255                  43.30          11.2         60          16.7         (gP          L1          GND
     17.766905                  45 .20         11.4         60          14.8         P            L1          GND



MEASUREMENT RESULT:                           "F—1198—4fin2"
 2019—1—14                10:05MM
     Frequency                  Level        Transd      Limit    Margin             Detector     Line         PE
           MEz                   dBuV            dB       dBuv        dB

      0. 341378                 31.70          10. 6        49          17.5      AV              L1          GND
      0. 654382                 33. 60         10.8         46          12.4      AV              L1          GND
      1.015172                  32.60          10.8         46          13.4      AV              L1          GND
      4.992190                  33.20          11.2         46          12.8      AV              L1          GND
      5.300255                  34 .80         11.2         50          15.2      AV              L1          GND
     17.766905                  39. 60         11.4         50          10.4      AV              L1          GND


                                                                                          Report No.: ATE20190037
                                                                                                       Page 14 of 22



          5. RADIATED EMISSION MEASUREMENT


                 5.1.Block Diagram of Test
                           5.1.1.Block diagram of connection between the EUT and simulators


                         AC Mains


                                          Adapter                 LOAD

                                                                  EUT


                           5.1.2.Block diagram of test setup (In chamber)




FCC ID: 2ASBE-DEV00106                                                          Shenzhen Accurate Technology Co., Ltd


                                                                                             Report No.: ATE20190037
                                                                                                          Page 15 of 22



                 5.2.Radiated Emission Limit
                                Frequency              Distance                 Field Strengths Limit
                                   MHz                  Meters                V/m              dBV/m
                                 0.009-30                300                    15               103.5
                                   30-88                  3                    100                40.0
                                  88-216                  3                    150                43.5
                                 216-960                  3                    200                46.0
                                Above 960                 3                    500                54.0
                          Limit: 0.009-30MHz = 20log (15) +40log (300/3) dBV/m
                          Distance Correction Factor=40log(test distance/specific distance)


                 5.3.EUT Configuration on Measurement
                         The equipments are installed on Radiated Emission Measurement to meet the commission
                         requirements and operating regulations in a manner which tends to maximize its emission
                         characteristics in normal application.


                 5.4.Operating Condition of EUT
                           5.4.1. Setup the EUT and simulator as shown as Section 5.1.

                           5.4.2. Turn on the power of all equipment.

                           5.4.3. Let the EUT work in test mode and measure it.


                 5.5.Measurement Procedure
                         The EUT and its simulators are placed on a turntable, which is 0.8 meter high above
                         ground. The turntable can rotate 360 degrees to determine the position of the maximum
                         emission level. EUT is set 3.0 meters away from the receiving antenna, which is mounted
                         on an antenna tower. The antenna can be moved up and down between 1.0 meter and 4
                         meters to find out the maximum emission level. Broadband antenna (calibrated bilog
                         antenna) is used as receiving antenna. Both horizontal and vertical polarizations of the
                         antenna are set on measurement. In order to find the maximum emission levels, all of the
                         interface cables must be manipulated according to ANSI C63.10: 2013 on radiated
                         emission measurement.

                         From 9kHz to 30MHz at distance 3m The EUT was rotated a full revolution in order to
                         obtain the maximum value of the electric field intensity.
                         The final level, expressed in dBuV/m, is arrived at by taking the reading from the EMI
                         receiver(Level dBuV) and adding the antenna correction factor and cable loss
                         factor(Factor dB) to it. This result then has to be compared with the relevant FCC
                         limit.The resolution bandwidth during the measurement is as follows:

                         9kHz – 150kHz: ResBW: 200Hz
                         150kHz – 30MHz: ResBW: 9kHz



FCC ID: 2ASBE-DEV00106                                                             Shenzhen Accurate Technology Co., Ltd


                                                                                              Report No.: ATE20190037
                                                                                                           Page 16 of 22



                 5.6.Data Sample
           Frequency(        Reading        Factor          Result       Limit         Margin            Remark
           MHz)              (dBv)         (dB/m)          (dBv/m)     (dBv/m)      (dB)
           X.XX              49.83          -22.03          27.80        43.50         -15.70            QP

                         Frequency(MHz) = Emission frequency in MHz
                         Reading(dBv) = Uncorrected Analyzer/Receiver reading
                         Factor (dB/m)= Antenna factor + Cable Loss – Amplifier gain
                         Result(dBv/m) = Reading + Factor
                         Limit (dBv/m)= Limit stated in standard

                         Calculation Formula:

                         Margin(dB) = Result (dBv/m)–Limit(dBv/m)

                         Result(dBv/m)= Reading(dBv)+ Factor(dB/m)

                         The “Margin” column of the following data tables indicates the degree of compliance
                         with the applicable limit. For example, a margin of -7dB means the emission is 7dB
                         below the limit.


                 5.7.Measurement Result
                         Pass.

                         Note: 185KHz is fundamental frequency.

                         Emissions attenuated more than 20 dB below the permissible value are not reported.

                         The spectrum analyzer plots are attached as below.

                         EUT test at X,Y,Z position,
                         Measured at Antenna position 0 degree and 90 degree, only worse case is reported.




FCC ID: 2ASBE-DEV00106                                                              Shenzhen Accurate Technology Co., Ltd


ACCURATE TECHNOLOGY CO., LTD

RADIATED EMISSION STANDARD                          FCC PART 18 C
EUT:                             Airpatch Charger M/N:DEVOOLOG
Manufacturer:                    Ectosense NV
Operating Condition:             Max. Power Output
Test Site:                       1#Shielding Room
Operator:                        Frank
Test Specification:              AC 120¥/608z
Comment:                         X
Start of Test:                   2019—1—16 / 18:02:02


SCAN TABLE: "LFRE(E) Fin"
  Short Description:                             _SUB_STD_VTERM2 1.70
  Start      Stop       Step                        Detector Meas.         IF           Transducer
  Frequency   Frequency Width                                 Time         Bandw.
  9.0 kHz            150.0 kHz        100.0 Hz      QuasiPeak 1             200 Hz      15168
  150.0 kHz          30.0 MHz         5.0 kHz       QuasiPeak 1             9 kHz       1516R


   Level [dBpV/m]

 110
 100


  80


  60


  ao

  20



       k      20k—    30k   50k 70k 100k      200k 300k 500k         1M    2M   3M 4M    6M     10M               30M
                                                      Frequency [H2]

x x cuzs            37—15_fin
  ues            37—15_pre
e 17M           18e                    Voltage AV




MEASUREMENT RESULT:                   "FC—0037—15fin"

2019—1—16   10:48
   Frequency      Level              Transd    Limit     Margin     Det.   Height    Azimuth         Polarization
          MEz   Bu¥/m                    ds   dbuV/m         dB                on        deg

       0.035000          40.10         20.1      103.5      63.4    QP      100.0         0.00
                                                                                                  404 M D4 BX M




       0.061000          28.20         20.1      103.5      75.3    QP      100.0         0.00
       0.063000          35.70         20.1      103.5      67.8    P       100.0         0.00
       0.090200          45.20         20.1      103.5      58.3    QP      100.0         0.00
       0.150000          45.10         20.1      103.5      58.4    QP      100.0         0.00
       0.185000          70.04         20.2      103.5      $5.5    9f      100 .0        0.00


ACCURATE TECHNOLOGY CO., LTD

RADIATED EMISSION STANDARD                       FCC PART 18 C
EUT:                 Airpatch Charger M/N: DEVO0106
Manufacturer:        Ectosense NV
Operating Condition: Max. Power Output
Test Site:           l#Shielding Room
Operator:            Frank
Test Specification:            AC 120V/60Hz2
Comment:                       3
Start of Test:                 2019—1—16 / 18102:02



SCAN TABLE: "LFRE(E) Fin"
  Short Description:            _SUB_STD_VITERM2 1.70
  Start      Stop      Step        Detector Meas.                            IF           Transducer
  Frequency Frequency Width                   Time                           Bandvw.
  9.0 kHz    150.0 kHz 100.0 Hz    QuasiPeak 1.0 s                           200 Hz       15162
  150.0 kHz         30.0 MHz      5.0 kBz        QuasiPeak 1.0 s              9 kHz       15168


   Lovel [dBpV/m]

 110
 100


  80


  60


  40

  20
  10
       Ok     20k    30k   50k 70k 100k     200k 300k    500k         1M     2M   3M 4M    6M       10M     30M
                                                     Frequency [Hz]



                                    Voltage AV




MEASUREMENT RESULT:               "FC—0037—16_fin"

2019—1—16   10150
   Frequency      Level          Transd      Limit      Margin        Det.   Eeight    Azimuth        Polarization
          MBz   dBuV/m               db     dBuV/m          dB                   cm        deg

       0.031400        38.40       29.1      103.5         65.1       oPf     100.0         0.00      Y
       0.035000        39.60       20.1      103.5         §3.9       QP      100.0         0.00      ~v
          63000        35.80       20.1      103.5         67.17      oP      100.0         0.00      x¥
       0.094400        34.10       20.1      103.5         68.8       Qr      100.0         0.00      %
       0.150000        40.30       20.1      103.5         63.2       QP      100.0         0.00      °¥
       0.185000        67.90       20.2      103.5         35.6       QP      100.0         0.00—     %


ACCURATE TECHNOLOGY CO., LTD

RADIATED EMISSION STANDARD                          FCC PART 18 C
EUT:                            Airpatch Charger M/N:DEVOO106
Manufacturer:                   Ectosense NV
Operating Condition: Max. Power Output
Test Site:           1#Shielding Room
Operator:            Frank
Test Specification:  AC 120v/608z
Comment:                        2
Start of Test:                  2019—1—16 / 18102:07


SCAN TABLE:           "LERE(E)        Fin"
  Short Description:                             _SUB_STD_VTERMZ 1.70
  Start              Stop            Step             Detector        Meas.     IF           Transducer
  Frequency          Frequency      Width                             Time     Bandw.
  9.0 kiz            150.0 kHz       100.0 Hz         QuasiPeak   0 s           200 Hz       15168
  150.0 kBz          30.0 MHz        5.0 k8z          QuasiPeak 1.0 s           9 kBz        1516E


   Level [dBpV/im]

 110
 100

  80

  60

  40

  20

   0
       O       20k    30k   50k 70k 100k         200k 300k    500k      1M     2M    3M 4M    6M      10M                   30M
                                                         Frequency [Hz]

x x iMes
     ues
mm II34                               Voltag
                                             a




MEASUREMENT RESULT:                  "FR—0037—2_fin"
2019—1—16 10:51
   Frequency    Level               Transd        Limit    Margin       Det.   Height     Azimuth              Polarization
             MHz       dBuV/m           dB       dBuV/m          dB                  cm       deg

       0.015600         43.40         20.1        103.5        60.1     QP      100.0          0.00
                                                                                                        ba ba ty bu ba ba




       0.031200         42.40         20.1        103.5        61.1     P       100.0          0.00
       0.046600         48.40         20.1        103.5        55.1     QP      100.0          0.00
       0.062200         45.20         20.1        103.5        58.3     QP      100.0          0.00
       0.078600         42.30         20.1        103.5        61.2     QP      100.0          0.00
       0.185000         68.70         20—2        103.5        34.8     QP      100.0          0.00


o                                          ACCURATE TECHNOLOGY CO., LTD.                                                         Site: 1# Chamber
                                            F1,Bldg.A, Changyuan New Material Port Keyuan Rd,                         Tel:+86—0755—26503290
                                            Science & Industry Park,Nanshan Shenzhen,P.R.China                        Fax:+86—0755—26503396
Job No.:         STAR2018 #577                                                            Polarization:        Horizontal
Standard: FCC Part 18C 3M Radiated                                                        Power Source:         AC 120V/60Hz
Test item:           Radiation Test                                                       Date: 2019/01/16
Temp.(         C)/Hum.(%) 25           C/55%                                              Time: 17:15:22
EUT:                 Airpatch Charger                                                     Engineer Signature:             star
Mode:            Max power output                                                         Distance:       3m
Model:           DEVO0106
Manufacturer: Ectosense NV

Note:          Report No.:ATE20190037



      70.0       dBu¥/m
                                                                                                                      limit1 :       —
                                                                                                                      limit2;        —

      60



      50



      40



      30



      20



      10


      0.0                ;                   }                                        ;           |               (         ;

            30.000      l‘[l   50     6O     ?l]   80                                 éUU        ;U[I     500    l%UU      ;"U[l   1000.0 MHz




No.             (';/rlf-g)     (5533'23)           F(cai'ést;j" (dFéif/”/'fin (dém}m) w:erg)m petecter ETY 50377 Remork
1                 777407|           4086           2754      i33z       40.00    |26.68)     ap         200      301
2                 sa3i31|           di8ge          2746      1442       4350     |29.08)     ap         200       4s
3                i2i8809]           sa265          2749      256        4350     |—1834)     ap         200      105
4                1447809            4976           2605      2171       4350     2170        ap         200      222
5                ris3616)|          4187           —24.05    1982       4350     2368        ap         200      256
6                si8go875s)         4119           —20.68    2051       46.00    25.49)      ap         200      125


                                           ACCURATE TECHNOLOGY CO., LTD.                                                                  Site: 1# Chamber
                                            F1,Bldg.A,Changyuan New Material Port Keyuan Rd,                                    Tel:+86—0755—26503290
                                            Science & Industry Park, Nanshan Shenzhen,P.R.China                                 Fax:+86—0755—26503306
Job No.:        STAR2018 #578                                                                         Polarization:        Vertical
Standard: FCC Part 18C 3M Radiated                                                                    Power Source:         AC 120V/60Hz
Test item:           Radiation Test                                                                   Date: 2019/01/16
Temp.(_       C)/Hum.(%) 25            C/55 %                                                         Time: 17:16:38
EUT:                Airpatch Charger                                                                  Engineer Signature:            star
Mode:           Max power output                                                                      Distance:       3m
Model:          DEVOO106
Manufacturer: Ectosense NV

Note:         Report No.:ATE20190037



      70.0      dBu¥/m
                        }                                                                                                       Himit1:       «——
                                                                                                                                Himit2:       —
      n                                                                                                                       s



      50


      40


      30


      gg                                         52210032001   @E 0 BM   L200 00@   10000   20000d 0000000b ds



      10


      0.0               4                    ]                                                    H            H              1|
           30.000      40      5o     60     70 80                                               300         400      500     600 700        1000.0 MHz

                Freq.           Reading            Factor           Result          Limit   [Margin                Height Degree
No—            (viHz)          (dBuvim)               (dB)        (dBuvim)| (dBuvim)| (dBy °4*| (m)                          (deg)          RP®*
1                   62.3038)        44.13          —27.25            16.88          40.00   |—23.12]      QP       100         68
2                   97.0023)        4549           —27.66            17.83          43.50   |—25.67|      QP       100        100
3               120.6118|           51.79          —27.46           24.33           43.50   |—19.17|      QP       100        125
4               177.5179|           46.42          —26.26           20.16           43.50   |—23.34|      QP       100        140
§               245.2606|           41.73          —23.67            18.06          46.00   |—27.94|      QP       100        108
6               466.5230)           40.54          —16.81           23.73           46.00   |—22.27|      QP       100        224


                                                                                          Report No.: ATE20190037
                                                                                                       Page 22 of 22



          6. ANTENNA REQUIREMENT


             6.1.The Requirement
                     According to Section 15.203, an intentional radiator shall be designed to ensure that no
                     antenna other than that furnished by the responsible party shall be used with the device.


             6.2.Antenna Construction
                     Device is equipped with permanent attached antenna, which isn’t displaced by other
                     antenna. Therefore, the equipment complies with the antenna requirement of Section
                     15.203.




                                  Induction coil




                                          ***** End of Test Report *****




FCC ID: 2ASBE-DEV00106                                                          Shenzhen Accurate Technology Co., Ltd



Document Created: 2019-03-11 18:46:12
Document Modified: 2019-03-11 18:46:12

© 2024 FCC.report