18_NC05 RFExp

FCC ID: 2AS7V-NC05

RF Exposure Info

Download: PDF
FCCID_4499276

                          RF EXPOSURE EVALUATION

1. PRODUCT INFORMATION
   Product Description      ANC headphone

                            NC05, NC20, NC21, NC22, NC23,NC02, NC03, NC04, NC06, NC07,
                            NC08, NC09, NC10, NC11, NC12, NC13, NC15, NC16, NC17, NC18,
      Model Name
                            NC19, NC25, NC26, NC27, NC28, NC29, NC30, NC31, NC32, NC33,
                            NC35, NC36, NC37, NC38, NC39, NC40

         FCC ID             2AS7V-NC05


2. EVALUATION METHOD
According to 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation
distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test separation distance,
mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.
Where f(GHz) is the RF channel transmit frequency in GHz
Power and distance are rounded to the nearest mW and mm before calculation

3. CALCULATION

Pt= -2.977dBm=0.50mW

The value of the Maximum output power Pt is referred to the test report of the CFR47
§15.247.

The result for RF exposure evaluation SAR=(0.50mW /5mm) .[√2.480(GHz)]= 0.16<3.0
for 1-g SAR and ≤ 7.5 for 10-g extremity SAR.


4. CONCLUSION
The SAR evaluation is not required.