RF Exposure Info

FCC ID: 2AS69LLY00043845100

RF Exposure Info

Download: PDF
FCCID_4435805

                                                                                     LAB N° 1356
                                                                             Report No. 28113143 001

11.9     TEST: RF Exposure Requirements                                                            PASS

Parameters required prior to the    Laboratory Ambient Temperature (°C)             15 to 35 °C
test
                                    Relative Humidity (%)                            30 to 60 %
Parameters recorded during the      Laboratory Ambient Temperature (°C)                  ---
test
                                    Relative Humidity (%)                                ---
                                    Air pressure (hPa)                                  1020

                                        Power Supply / Frequency                 Application Point
Fully configured sample tested at                    +3,0V dc                            ---
the power line frequency
Equipment mode:                     Operation mode                                       #1
FCC Standard                                                    47 CFR 2.1093
Systems operating under the provisions of this section shall be operated in a manner that ensures that
the public is not exposed to radio frequency energy levels in excess of the Commission's guidelines
47 CFR 2.1093 - Radiofrequency radiation exposure evaluation: portable devices
EUT classification (fixed, mobile or
                                     Portable equipment
portable devices)

Limits
                                    See next table
Freq. Range 2402÷2480MHz




TRF FCC_15.247_000
                                               Page 59 of 62
07/10/2016


                                           LAB N° 1356
                                     Report No. 28113143 001




TRF FCC_15.247_000
                     Page 60 of 62
07/10/2016


                                                                                      LAB N° 1356
                                                                                Report No. 28113143 001
                                          Operating Condition #1

                              Max Radiated      Max Radiated
                                                                   Separation          Exemption Limit
              Frequency       Output Power      Output Power
                                                                    distance          (obtained by linear
   CH                             (P)               (P)
                                                                                        interpolation)
                                                                                             (mW)
                (MHz)             (dBm)             (mW)             (mm)

  Low            2402             -8,60            0,138               5                    10,08

 Middle          2440            -12,18            0,060               5                    10,01

  High           2480            -12,02            0,062               5                     9,94

                                                VERDICT

  SAR evaluation is not required because the output power value is less than exemption limit (separation
                                            distance 5mm)




TRF FCC_15.247_000
                                                Page 61 of 62
07/10/2016



Document Created: 2019-09-05 18:04:53
Document Modified: 2019-09-05 18:04:53

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC