Appendix F SAR Plot and Volume Scan

FCC ID: 2AS57OSSIACOTATX201

RF Exposure Info

Download: PDF
FCCID_4308403

Test Laboratory: UL Verification Services Inc. SAR Lab 5                    Date/Time: 4/8/2019 9:34:20 AM

2450MHz CW
Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 2.01 S/m; εr = 50.935; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1258; Calibrated: 5/22/2018
- Probe: EX3DV4 - SN7501; ConvF(7.83, 7.83, 7.83) @ 2450 MHz; Calibrated: 5/4/2018
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: Base Station Phantom; Type: UL BSTP-C; Serial: 1001

Boresight/Client 339_MCNPS_2450MHz CW _88 cm distance/ Tile 90 Degrees/ Client 90
Degrees/Area (19x34x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 0.926 W/kg

Boresight/Client 339_MCNPS_2450MHz CW _88 cm distance/ Tile 90 Degrees/ Client 90
Degrees/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 20.57 V/m; Power Drift = -0.02 dB
Peak SAR (extrapolated) = 1.17 W/kg
SAR(1 g) = 0.631 W/kg; SAR(10 g) = 0.341 W/kg
Maximum value of SAR (measured) = 0.966 W/kg




                      0 dB = 0.966 W/kg = -0.15 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab 5                    Date/Time: 4/8/2019 12:38:16 PM

2450MHz CW
Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 2.01 S/m; εr = 50.935; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1258; Calibrated: 5/22/2018
- Probe: EX3DV4 - SN7501; ConvF(7.83, 7.83, 7.83) @ 2450 MHz; Calibrated: 5/4/2018
- Sensor-Surface: 1.4mm (Mechanical Surface Detection)
- Phantom: Base Station Phantom; Type: UL BSTP-C; Serial: 1001

Volume Scan/Client 339_MCNPS_2450MHz CW _88 cm distance/ Tile 90 Degrees/ Client
90 Degrees/Volume Scan (97x393x105): Interpolated grid: dx=2.500 mm, dy=2.500 mm, dz=0.6250 mm
Reference Value = 20.75 V/m; Power Drift = 0.00 dB
IEC62232 Base station whole body SAR (Child): 0.0523 W/kg
Total Absorbed Power = 0.363 W
Penetration depth = 7.028 (6.842, 7.582) [mm]

Maximum value of SAR (measured) = 1.35 W/kg




                      0 dB = 1.35 W/kg = 1.30 dBW/kg




                                                                                                               Plot No. 2



Document Created: 2019-05-24 09:24:27
Document Modified: 2019-05-24 09:24:27

© 2024 FCC.report