04-2 FCC_Test Report_MPE_LDT-300BS

FCC ID: 2AS2Q-LDT-300BS

Test Report

Download: PDF
FCCID_4249494

_SGS
  Report Number:            F690501/RF—RTLO13679                                              Page:       1      of     5




                             TEST REPORT
                                                           of

                             FCC CFR 47 part 1, 1.1307(b), 1.1310

                                     FCC ID: 2AS2Q—LDT—300BS


Equipment Under Test                _:   MDT
Model Name                          :    LDT—300BS
Applicant                           :    LOOP Co., Ltd.
Manufacturer                        :    LOOP Co., Ltd.
Date of Receipt                     : 2018.11.28
Date of Test(s)                     :    2019.03.21 ~2019.03.29
Date of Issue                       : 2019.04.12



In the configuration tested, the EUT complied with the standards specified above.




 Tested By:          %                                              Date:                     2019.04.12

                                 Nancy Park


  Technical                   <z                                    Date:                     2019.04.12
  Manager:                  /{/—

                               Jungmin Yang




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, except in full, without prior written permission of the Company. This test report
does not assure KOLAS accreditation.
SGS Korea Co., Ltd. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807    hitp/www.sqsgroup.kr
RTT5041—19(2017.07.10)(0)                        Tel. +82 31 428 5700 /Fax. +82 31 427 2370           A4(210 mm x 297 mm)


  Report Number:            F690501/RE—RTLO13679                                               Page:      2        of       5



                                                  INDEX
                                               Table of Contents                                                  Page

  1. G@NQrAl INfOFMAtiON ——————————————~~~~nnnncoooooonennnccnnnnnnonnnnnnnnnnnnnnnnnnnnnennccccccee>                   3


  2. RF EXPOSUL® EV&IUAtION ———————————————nnnnnmoooneenenmnononnnnnnomnnnnnnnnnnnnnnnnenc                              5




The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, exceptin full, without prior written permission of the Company. This test report
does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807     hitp:/worw.sascroup ks
RTT5041—19(2017.07.10)(0)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


  Report Number:                F690501/RE—RTLO13679                                               Page:        3        of      5


1. General Information
1.1. Testing Laboratory

SGS Korea Co., Ltd. (Gunpo Laboratory)
     — 10—2, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807
     — 4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807
     — Designation number: KRO150
All SGS services are rendered in accordance with the applicable SGS conditions of service available on
request and accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx.
Phone No.                :   +82 31 688 0901

1.2. Details of Applicant

Applicant           :        LOOP Co., Ltd.
Address             :        3F, 70, Heungan—daero, 439beon—gil, Dongan—gu, Anyang—si, Gyeanggi—do, Korea,
                             14058
Contact Person      _:       Choi, Jung—Mo
Phone No.           :        +82 070 7116 6175

1.3. Details of Manufacturer
Company                  :   Same as applicant
Address                  :   Same as applicant

1.4. Description of EUT

 Kind of Product                    MDT

 Model Name                         LDT—3008S

 Power Supply                       DC 12 V, DC 24 V

 Frequency Range                    2 402 M ~2 480 Mk (Bluetooth Low Energy)

 Modulation Technique               GFSK

 Number of Channels                 40 channels (Bluetooth Low Energy)

 Antenna Type                       PCB Pattern Antenna

 Antenna Gain                       —2.54 dBi


1.5. Test Report Revision

Revision           Report number                    Date of Issue                            Description

    0         F690501/RF—RTLO13679                   2019.04.12                                    Initial


The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, exceptin full, without prior written permission of the Company. This test report
does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)       4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807       Affp:s/fivwwsasoroup kr

RTT5041—19(2017.07.10)(0)                            Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mm x 297 mm)


  Report Number:            F690501/RF—RTLO13679                                               Page:      4         of



2. RF Exposure Evaluation
2.1. Environmental evaluation and exposure limit according to FCC CFR 47 part 1,
1.1307(b), 11310
                       LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)

                                                   Magnetic Field
 Freque?m?)/ Range          ;fiflg&r\fi:\‘)              St(':/r:g)th           Pow(e]:w?c:;sny           Average Time



                                 (A) Limits for Occupational/Controlled Exposure

       0.3—3.0                   614                      1.63                     *100                        6

       3.0—30                   18427                    4.89/f                   *g00/f"                      6

       30—300                    61.4                    0.163                      1.0                        6

     300—1 500                    —                         —                      17300                       6

   1 500—100 000                  —                         —                        5                         6

                             (B) Limits for General Population/Uneontrolled Exposure

      0.3—1.34                   614                      1.63                     *100                       30

       1.34—30                  824/                     2.197                    *180/°                       30


       30—300                    27.5                    0.073                      0.2                       30

     300—1 500                    —                         —                     11500                       30

   1 500—100 000                  —                         —                       1.0                       30


2.1.1. Friis transmission formula: Pd = (Pout*G)/(4*pi*R‘)
    Where Pd = power density in mW/er‘
           Pout = output power to antenna in 1i
           G = gain of antenna in linear scale
           Pi=3.1416
           R = distance between observation point and center of the radiator in cm

Pd the limit of MPE, 1 iier. If we know the maximum gain of the antenna and the total power input to the
antenna, through the calculation, we will know the distance where the MPE limit is reached.


 The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, exceptin full, without prior written permission of the Company. This test report
does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeonggi—do, Korea, 15807     hitp:/worw.sascroup ks
RTT5041—19(2017.07.10)(0)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370           A4(210 mm x 297 mm)


  Report Number:             F690501/RE—RTLO13679                                              Page:        5        of        5


2.1.2. Test Result of RF Exposure Evaluation

    Test Item     _:    RF Exposure Evaluation Data
    Test Mode :         Normal Operation

2.1.3. Output Power into Antenna & RF Exposure Evaluation Distance

Blustooth Low Energy
— Maximum tune up tolerance
                                   Output Average                Antenna                Power Density                    j
    Frequenmr.:ly Range           Power to Antenna                 Gain                    at 20 on                    :‘];;,7;;
            tt                           (dBm)                     (dBi)                       (wticr)
        2 402 ~ 2 480                      —9                      —2.54                   0.000 014                      1


Note;

— The power density Pd (5th column) at a distance of 20 en calculated from the friis transmission
   formula is far below the limit of 1. ti/en‘.
= This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment.
= This equipment should be installed and operated with minimum 20 cm between the radiator and your
   body.
— The antenna gain of this transmitter is less than 6dBi and must not be collocated or operating in conjunction
  with any other antenna or transmitter unless authorized to do so by the FCC.




                                           — End of the Test Report —

 The results shown in this test report refer only to the sample(s) tested unless otherwise stated. This test
report cannot be reproduced, exceptin full, without prior written permission of the Company. This test report
does not assure KOLAS accreditation.
SGS Korea Co., Lid. (Gunpo Laboratory)   4, LS—ro 182beon—gil, Gunpo—si, Gyeanggi—do, Korea, 15807       Affp:s/fivwwsasoroup kr

RTT5041—19(2017.07.10)(0)                        Tel. +82 31 428 5700 / Fax. +82 31 427 2370             A4(210 mm x 297 mm)



Document Created: 2019-04-24 01:55:32
Document Modified: 2019-04-24 01:55:32

© 2024 FCC.report