RF Exposure Considerations for FCC ID: 2ARZVWM

The calculation of the MPE is as following:

Prediction of MPE limit at a prediction distance:

       P.G      E.I .R.P
S=            =
     4. ∏ .R ² 4. ∏ .R ²

S: Power density (mW/cm²)
P: Peak output power at antenna terminal (mW)
G: Numerical Antenna gain
R: Distance of radiation to antenna (cm)

MPE
F = 903.9 / 908.3MHz
P = 41.7mW (14dBm + 2.2dBi)
GidB = 2.2dBi
R= 20cm
S=0.0083mW/cm²
MPE limit for uncontrolled exposure: 0.6mW/cm²                             Below MPE limit

Conclusion: Therefore the device complies with FCC’s RF radiation exposure limits for general
population for a mobile device.

Certified By
Laurent CHAPUS (Agent for this device)
SMEE
Rue de Taille
ZI des Blanchisseries
38500 Voiron - France
laurent.chapus@smee.fr
FCC Registration Number: 0020356952 (FRN)

Applicant for this device:
WIZZILAB SAS
29 boulevard Romain Rolland
92120 MONTROUGE - FRANCE
Yordan TABAKOV
yordan@wizzilab.com (CTO)
+33 661 574 896




COORDONNEES
SMEE                                                                                                  TEL : 04 76 65 76 50
Rue de Taille – ZI Des Blanchisseries                                                                 FAX : 04 76 66 18 30
38500 VOIRON - France
     SAS au capital de 50 000 € / RC Grenoble B534 796 453 / SIRET 534 796 453 00015 / code APE 7490B / n° TVA : FR   59 534 796 453



Document Created: 2019-03-27 09:16:18
Document Modified: 2019-03-27 09:16:18

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC