User Manual

FCC ID: 2ARYH-SAYA-SA0100

Users Manual

Download: PDF
FCCID_4321450

    / saya      Smart Water Management




        SAYA SMART WATER MANAGEMENT




     @               Smart Water Management




CONFIDENTIALITY NOTICE:
This documentincluding images is contfidential and is strictly for the intended recipient. If you are not an
intended recipient or authorized representative thereof and have received this information in error, you
will be subject to all applicable laws governing its prohibited disclosure or distribution. If you have
received this document in error, notify iConnectZone Inc d/b/a SAYA and destroy all copies of these
documents.


                                                                                                                                           Page|1




                                                                 Content



1  BriefIntroduction....................................................................................................................... 4
2  SAYASolutionHighlights .......................................................................................................... 4
   2.1     SAYAMeterFeatures...................................................................................................... 4
3  TechnicalDetails........................................................................................................................ 5
   3.1     Basictechnicaldetails ..................................................................................................... 5
   3.2     FlowParameters ............................................................................................................. 6
4  OverallDimensions.................................................................................................................... 6
5  OperationInstructions ................................................................................................................ 7
6  InstallationandConnection......................................................................................................... 8
   6.1     Installation andConnectionRequirements ..................................................................... 8
   6.2     MeterInstallation ........................................................................................................... 8
7  Calibration............................................................................................................................... 10
8  Troubleshooting ...................................................................................................................... 10
9  Parts List ........................................................................................................................................... 11
10    TransportationandStorage ................................................................................................... 11
11 Disclaimer ............................................................................................................................... 11




CONFIDENTIALITY NOTICE:
This document including images is confidential and is strictly for the intended recipient. If you are not an
intended recipient or authorized representative thereof and have received this information in error, you
will be subject to all applicable laws governing its prohibited disclosure or distribution. If you have
received this document in error, notify iConnectZone Inc d/b/a SAYA and destroy all copies of these
documents.


                                                                                                                         Page|2




                                                        Figures



     Figure 4-1OverallDimensions ................................................................................................... 6
     Figure 5-1 Mobile AppandDashboard ...................................................................................... 7
     Figure 6-1InstallationMethod.................................................................................................... 9
     Figure 6-2 MeterInstallation(1) ................................................................................................. 9
     Figure 6-3 MeterInstallation(2) ................................................................................................. 9




CONFIDENTIALITY NOTICE:
This document including images is confidential and is strictly for the intended recipient. If you are not an
intended recipient or authorized representative thereof and have received this information in error, you
will be subject to all applicable laws governing its prohibited disclosure or distribution. If you have
received this document in error, notify iConnectZone Inc d/b/a SAYA and destroy all copies of these
documents.


                                                                                                                              Page|3




                                                            Tables



     Table 3-1TechnicalDetails ......................................................................................................... 6
     Table 3-2FlowParameters .......................................................................................................... 6
     Table 4-1OverallDimensions..................................................................................................... 6
     Table 6-1 Special Cases and ReservedPipe Length ................................................................... 8
     Table8-1Troubleshooting ........................................................................................................ 10
     Table 9-1Parts List .................................................................................................................. 11




CONFIDENTIALITY NOTICE:
This document including images is confidential and is strictly for the intended recipient. If you are not an
intended recipient or authorized representative thereof and have received this information in error, you
will be subject to all applicable laws governing its prohibited disclosure or distribution. If you have
received this document in error, notify iConnectZone Inc d/b/a SAYA and destroy all copies of these
documents.


                                                                                 Page|4




1 BriefIntroduction
ThankyouforpurchasingtheSAYAWATER MANAGEMENTSYTEM.Saya’sTechnologySAVESMONEYPROTECTS
PROPERTY, and FOSTERS PEACE OF MIND by providing real time control of water systems, to MONITOR
FLOW and PREVENT DAMAGE CAUSED BYLEAKS.

Let’s connect your life!!

 Package Contains:
     SAYA Ultrasonic Smart meter with remote shut-offvalve
     Smart WirelessGateway
     Options: Pressure sensor, Temperature sensor, Floodsensor




2 SAYA SolutionHighlights
The SAYA system comes packaged with water detecting flood sensors, a smart ultrasonic flow meter with remote shut-off
valve and a wireless gateway that can send analytics data to a mobile device or a dashboard.

The key features are

       Smart water Management and Consumptiontracking
       Scan for anomalies, pinpoint leaks and failures, send instant actionable alerts and shutoff the mainline.
       Temperature sensor for freezeprotection
       Detailed daily, weekly, monthly and yearly consumptionreports
       Pressure sensor to detect pipe burst or sudden loss of pressure due toleak.
       Analytics and Riskmanagement


    2.1 SAYA Meter Features

•   TheSAYASmartmeterisatechnologicallyadvancedsolutionwithintegratedtemperaturesensor,pressuresensor and
    ultrasonic flowsensor.
•   The meter uses ultrasonic sensing to measure the water flowing through the pipe with high degree of precision.It
    also measures the pressure and temperature of the water. The meter sends this data to a Gateway for processing.
•   The SAYA Ultrasonic smart meter integrates measurement, display, valve control and LORA wireless
    communication for longrange.
•   The meter adopts micro-power technology to achieve accurate measurement with a minimum flow of 0.01m3/h

                                                              4


                                                                                        Page|5

•   Saya meter can support multi-angle installation and minimize the pipe pressureloss.




3 Technical Details

    3.1 Basic technicaldetails

                                Parameter                                       Performance
                               Diameter (mm)                                          1 inch
                                    Q3/Q1                                             R250
                                Pressure Loss                                         Δp40
                                                                           water or homogeneous liquid
                             Measured Medium                     * Pipes   must be full with measured medium.
                                  Accuracy                                      Class 2 (Class B)
                        Maximum Working Pressure                                     232 PSI
                             Work Environment                                5℃~+55℃, ≤100% RH
                            Temperature Grade                                          T50
                     Sensitivity of Upstream Flow Field                               U10
                   Sensitivity of Downstream Flow Field                                D5
                          Climatic and Mechanical
                                                                                        B
                           Environmental Grades
                                 EMC Grade                                             E1
                                   Keypad                                     magnetic induction key
                                    LCD                                       LCD 8 digits + prompt
                                                             instantaneous flow(m³/h ), cumulative flow(gallons),
                               Menu Contents                 screen detection, meter address, cumulative working
                                                                  time(h), date(yy-mm-dd), software version
                               Display Range                         cumulative flow: 0m³ ~ +99999.999m³


                                                                             modulation mode: LoRa
                  Communication                                            frequency: 910MHZ-920MHZ
                                       Wireless Interface
                                                                           transmission distance≧3000m
                                                                     based on CJ/T 188 self-defined protocol

                                                                 5


                                                                          Page|6


                                                  1. External 5V powersupply
                                                  2. One ER26500 battery is used as the backup
                       Power Supply
                                                         power supply, DC3.6V (for flow measurement
                                                         only)
                 Power Consumption                                     <0.2mW
                      Waterproof Rate                                    IP68
                 Storage Temperature                                -25℃~ +55℃
                       Cable Length                                      1.0m
                  Installation Position                               inflow pipe
                                        Table 3-1 Technical Details



  3.2 Flow Parameters

                             Permanent          Transitional         Minimum           Overload
           Diameter             Q3                  Q2                  Q1               Q4
                              (m³/h)             (m³/h)              (m³/h)            (m³/h)
            1 inch               6.3               0.04                0.025             7.875
                                        Table 3-2 Flow Parameters




4 OverallDimensions




                                      Figure 4-1 Overall Dimensions


         Diameter(mm)          Thread             L (mm)             W (mm)            H (mm)
             1 inch             G1¼B                220                 83.5             103
                                       Table 4-1 Overall Dimensions

                                                     6


                                                                                       Page|7



5 OperationInstructions
All relevant information for the customer will be available on the mobile app and dashboard




                                           Figure 5-1 Mobile App and Dashboard




                                                                  7


                                                                                       Page|8



6 Installation andConnection

    6.1 Installation and ConnectionRequirements

 Install the meter in strict accordance with the requirements. Strictly forbidden to self-removemeter.
 Before installing the water meter, remove dirt and other rubbish in pipeline to avoid malfunction of watermeter.
 Leave enough space for meter and connectorsinstallation.

 To ensure the measurement accuracy, the reserved length space is the following. In the front of meter, the length space is over 10
    times of diameter. Behind meter, the length space is over 5 times of diameter. Avoid the interference from elbow pipe, tee, cone
    pipeandpump.Ifthereisareduceddiameterpipeinstalledbeforemeter,thereservedlengthspacewillbeover15timesofdiameter; if a 90°
    elbow, the length must be 20 times of diameter; if a half-opening valve, the space is over 50 times ofdiameter.
                     *D=diameter
                     L F = the length in the front of
                     meter L B =the length behind meter

                     Special Case                                        Reserved Pipe Length
                     usual (normal installation)                         L F > 10D
                                                                         L B > 5D
                     a reduced diameter pipe in the front of meter       L F > 15D
                     a 90° elbow in the front of meter                   L F > 20D
                     a half-opening valve in the front of meter          L F > 50D
                                    Table 6-1 Special Cases and Reserved Pipe Length
 Avoid damage to the water meter caused by impact or vibration of the meter installation environment, and avoid damage caused
  by excessive stress from pipes and fittings. If necessary, please install the water meter on the base orbracket.
 Prevent extreme water temperature, extreme temperature, and external environment corrosion to water meterdamage.
 Avoid cavitation, surge and waterhammer.




    6.2 MeterInstallation

➢   The installed pipe must be filled with water. Install the meter on a vertical pipe in which the liquid flows upwards or diagonally
    upwards.Ifnot,selectahorizontalpipe.TrytoAVOIDinstallingthemeterinaverticalpipewiththeliquidflowingdownwardsor
    diagonallydownwards.
➢   AVOID installing meter at the highest point of pipeline to prevent the air bubbles accumulated and interfere withmeasurement.




                                                                  8


                                                                                       Page|9




                                                Figure 6-1 Installation Method

➢   Reserve a space at the water pipe for meterinstallation.




                                               Figure 6-2 Meter Installation (1)
➢   Concentrically align meter with pipe. Use a wrench to connect the pipe blade to meter thread and tightenit.




                                               Figure 6-3 Meter Installation (2)



                                                                  9


                                                                                  P a g e | 10



7 Calibration
It conforms to NCWM and AWWA Cold Water Meter Calibration Regulations.
NTEP CC: 19-018
NSF 61
FCC




8 Troubleshooting

                No.        Malfunction               Description Solution                        Notes
                                                                        Please change
                  1    Low Voltage                   LCDdisplays        a new battery.
                                                     LCD displays a     Install meter     Please send meter
                                                     negative number    in right          back to factory if
                  2    Reverse Flow
                                                                        direction.        this problem can’tbe
                                                                                          solved in this way.
                       Install Meter Downstream      (1) abnormaldata   Install meter
                       Insufficient Reserved         (2) datajump       according to
                       Place in the Front                disorderly     instructions.
                       of/Behind the Meter
                  3    Great Bend in the Front
                       of/Behind the Meter
                       The Pipe Diameter
                       Changes Greatly in the
                       Front of/Behind the Meter
                                                     LCD displays                         Do not dismantle
                                                     flow but without                     without permission.
                  4                                  temperature                          Please return meter
                                                                                          to factory for
                                                                                          settlement.
                                                 Table 8-1 Troubleshooting




                                                              10


                                                                                      P a g e | 11



9 PartsList
              No.                    Item                         Unit           Quantity               Notes
                1                 Water Meter                         piece             1
                2                Product Manual                       piece             1
                3     CERTIFICATION & Warranty Card                   piece             1
                4                 Sealing Ring                        piece             2
                5               Connector Screw                       piece             2               optional
                6                Connector Nut                        piece             2               optional
                                                      Table 9-1 Parts List




10 Transportation andStorage
•   Keep meter in originalpackage
•   Store in non-corrosive, 5 ° C - 40 ° Cenvironment.
•   Keep the stacking height LESS THAN 5cartons.




11 Disclaimer
■   This meter conforms to Class E1 (for residential, commercial, light industrial environment) and Class B (installedindoors).
■   This manual does not contain any clear or implied warranties. iConnectZone d/b/a SAYA holds all rights to make adjustments
    and amendments on this manual. Manual is based on actualproducts.
■   Iconnectzone d/b/a SAYA can accept NO liability resulting from the improper use or installation of thisproduct.
■   iConnectzone Inc d/b/a SAYA can accept NO liability if the sealing lead is destroyed orincomplete.
■   iConnectzone Inc d/b/a SAYA can accept NO liability except meter malfunction and related liability (including but not limited to
    the liability of metering disputes caused by water metermalfunction).




                                                                 12


                                                                                         P a g e | 12

FCC STATEMENT :
This device complies with Part 15 of the FCC Rules. Operation is subject to the followingtwo conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that maycause undesired operation.
Warning: Changes or modifications not expressly approved by the party responsible forcompliance could void the user's authority to
operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a Class Bdigital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to providereasonable protection against harmful interference in a residential installation. This
equipment generates uses and can radiate radio frequency energy and, if not installedand used in accordance with the instructions, may
cause harmful interference to radiocommunications. However, there is no guarantee that interference will not occur in aparticular
installation. If this equipment does cause harmful interference to radio ortelevision reception, which can be determined by turning the
equipment off and on, theuser is encouraged to try to correct the interference by one or more of the following
measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled
environment. This equipment should be installed and operated with minimum distance
20cm between the radiator & your body




                                                                   12



Document Created: 2019-05-20 16:53:41
Document Modified: 2019-05-20 16:53:41

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC