MPE

FCC ID: 2ARUV-MWF82S01

RF Exposure Info

Download: PDF
FCCID_4151366

                    FCC RF Exposure Report
            FCC ID                          : 2ARUV-MWF82S01
            Equipment                       : 802.11bgn module
            Model No.                       : PT7682W-SAOPTC0
            Brand Name                      : PTCOM
            Applicant                       : PTCOM Technology CO.,LTD.
            Address                         : 8F., No.89, Sec. 4, Chongxin Rd., Sanchong
                                              Dist., New Taipei City 24161, Taiwan (R.O.C.).
            Standard                        : 47 CFR FCC Part 2.1091
            Received Date                   : Oct. 31, 2018
            Tested Date                     : Nov. 04 ~ Dec. 04, 2018


      We, International Certification Corp., would like to declare that the tested sample has been
      evaluated and in compliance with the requirement of the above standards. The test results
      contained in this report refer exclusively to the product. It may be duplicated completely for
      legal use with the approval of the applicant. It shall not be reproduced except in full without
      the written approval of our laboratory.



      Reviewed by:                                   Approved by:




      Along Chen / Assistant Manager                 Gary Chang / Manager




Report No.: FA8O3102                                                                      Page : 1 of 5
Report Version: Rev. 02
The previous version of the test report has been cancelled and replaced by new version.


                                                   Table of Contents
1        MPE EVALUATION OF MOBILE DEVICES ......................................................................................... 4

1.1      LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE............................................. 4
1.2      MPE EVALUATION FORMULA ............................................................................................................. 4
1.3      MPE EVALUATION RESULTS .............................................................................................................. 4

2        TEST LABORATORY INFORMATION ................................................................................................. 5




Report No.: FA8O3102                                                                                                Page : 2 of 5
Report Version: Rev. 02
The previous version of the test report has been cancelled and replaced by new version.


                                                  Release Record
     Report No.                 Version                               Description            Issued Date
     FA8O3102                    Rev. 01           Initial issue                             Jan. 15, 2019
     FA8O3102                    Rev. 02           Modified model name and applicant.        Jan. 24, 2019




Report No.: FA8O3102                                                                      Page : 3 of 5
Report Version: Rev. 02
The previous version of the test report has been cancelled and replaced by new version.


1          MPE EVALUATION OF MOBILE DEVICES
Human exposure to RF emissions from mobile devices (47 CFR §2.1091) may be evaluated based on the
MPE limits adopted by the FCC for electric and magnetic field strength and/or power density, as appropriate,
since exposures are assumed to occur at distances of 20 cm or more from persons.



1.1        LIMITS FOR GENERAL POPULATION/UNCONTROLLED EXPOSURE

      Frequency Range (MHz)                        Power Density (mW /cm2)                 Averaging Time (minutes)
                300~1500                                      F/1500                                    30
             1500~100000                                         1.0                                    30


1.2        MPE EVALUATION FORMULA
                                 Pt
                  Pd =
                            4 * Pi * R 2
Where

Pd=   Power density in mW/cm2
Pt=   EIRP in mW
Pi=   3.1416
R=    Measurement distance


1.3        MPE EVALUATION RESULTS
MPE Evaluation of Single Transmission
                     Maximum                                                                   Power
  Frequency                     Rated Power                 Antenna             Distance                       Limit
                     Conducted                                                                Density
 Range (MHz)                       (dBm)                    Gain (dBi)            (cm)                       (mW/cm2)
                    Power (dBm)                                                              (mW/cm2)
    2412~2462             18.93               19                 0.5                20          0.018               1




Report No.: FA8O3102                                                                                Page : 4 of 5
Report Version: Rev. 02
The previous version of the test report has been cancelled and replaced by new version.


C          International
           Certification
           Corp.




2          Test laboratory information
Established in 2012, ICC provides foremost EMC & RF Testing and advisory consultation services by our
skilled engineers and technicians. Our services employ a wide variety of advanced edge test equipment and
one of the widest certification extents in the business.


International Certification Corp (EMC and Wireless Communication Laboratory), it is our definitive objective is
to institute long term, trust—based associations with our clients. The expectation we set up with our clients is
based on outstanding service, practical expertise and devotion to a certified value structure. Our passion is to
grant our clients with best EMC / RF services by oriented knowledgeable and accommodating staff.


Our Test sites are located at Linkou District and Kwei Shan District. Location map can be found on our
website http //vww.icertifi.com.tw.


Linkou                                        Kwei Shan                                   Kwei Shan Site II
Tel: 886—2—2601—1640                          Tel: 886—3—271—8666                         Tel: 886—3—271—8640
No. 30—2, Ding Fwu Tsuen, Lin                 No. 3—1, Lane 6, Wen San 3rd St.,           No. 14—1, Lane 19, Wen San 3rd
Kou District, New Taipei City,                Kwei Shan District, Tao Yuan City           St., Kwei Shan District, Tao Yuan
Taiwan, R.O.C.                                333, Taiwan, R.O.C.                         City 333, Taiwan, R.O.C.

If you have any suggestion, please feel free to contact us as below information.

Tel: 886—3—271—8666
Fax: 886—3—318—0155
Email: ICC_Service@icertifi.com.tw




==END=




Report No.: FABO3102                                                                                    Page : 5 of 5
Report Version: Rev. 02
The previous version of the test report has been cancelled and replaced by new version.



Document Created: 2019-01-24 17:25:40
Document Modified: 2019-01-24 17:25:40

© 2024 FCC.report