SAR Report Appendix 2

FCC ID: 2ARTXT101

RF Exposure Info

Download: PDF
FCCID_4185087

 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GSM (0); Frequency: 836.6 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.6 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Worn Back/GSM 850 Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.597 W/kg

Body Worn Back/GSM 850 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 28.27 V/m; Power Drift = 0.027 dB
Peak SAR (extrapolated) = 1.02 W/kg
SAR(1 g) = 0.582 W/kg; SAR(10 g) = 0.369 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.655 W/kg




             0 dB = 0.655 W/kg = -1.84 dBW/kg




SAR Plots                                                                                   Plot 1#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GPRS-4 slots (0); Frequency: 836.6 MHz;Duty Cycle: 1:2
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.6 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/GSM 850 Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.807 W/kg

Body Back/GSM 850 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 32.84 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 1.36 W/kg
SAR(1 g) = 0.723 W/kg; SAR(10 g) = 0.422 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.781 W/kg




             0 dB = 0.781 W/kg = -1.07 dBW/kg




SAR Plots                                                                                  Plot 2#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GPRS-4 slots (0); Frequency: 836.6 MHz;Duty Cycle: 1:2
Medium parameters used (interpolated): f = 836.6 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.6 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/GSM 850 Mid/Area Scan (101x121x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.710 W/kg

Body Top/GSM 850 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 30.63 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 1.28 W/kg
SAR(1 g) = 0.581 W/kg; SAR(10 g) = 0.319 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.692 W/kg




             0 dB = 0.692 W/kg = -1.60 dBW/kg




SAR Plots                                                                                  Plot 3#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GSM (0); Frequency: 1880 MHz;Duty Cycle: 1:8
Medium parameters used (interpolated): f = 1880 MHz; σ = 1.493 S/m; εr = 54.024; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(7.48, 7.48, 7.48) @ 1880 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Worn Back/GSM 1900 Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.646 W/kg

Body Worn Back/GSM 1900 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 15.19 V/m; Power Drift = -0.10 dB
Peak SAR (extrapolated) = 1.43 W/kg
SAR(1 g) = 0.468 W/kg; SAR(10 g) = 0.221 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.622 W/kg




             0 dB = 0.622 W/kg = -2.06 dBW/kg




SAR Plots                                                                                  Plot 4#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GPRS-4 slots (0); Frequency: 1880 MHz;Duty Cycle: 1:2
Medium parameters used (interpolated): f = 1880 MHz; σ = 1.493 S/m; εr = 54.024; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(7.48, 7.48, 7.48) @ 1880 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/GSM 1900 Mid/Area Scan (61x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.705 W/kg

Body Back/GSM 1900 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 18.61 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 1.31 W/kg
SAR(1 g) = 0.562 W/kg; SAR(10 g) = 0.257 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.689 W/kg




             0 dB = 0.689 W/kg = -1.62 dBW/kg




SAR Plots                                                                                  Plot 5#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic GPRS-4 slots (0); Frequency: 1880 MHz;Duty Cycle: 1:2
Medium parameters used (interpolated): f = 1880 MHz; σ = 1.493 S/m; εr = 54.024; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(7.48, 7.48, 7.48) @ 1880 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/GSM 1900 Mid/Area Scan (101x121x1): Interpolated grid: dx=1.000 mm, dy=1.000 mm
Maximum value of SAR (interpolated) = 0.255 W/kg

Body Top/GSM 1900 Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm,
dz=5mm
Reference Value = 9.852 V/m; Power Drift = -0.12 dB
Peak SAR (extrapolated) = 0.467 W/kg
SAR(1 g) = 0.183 W/kg; SAR(10 g) = 0.109 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.239 W/kg




             0 dB = 0.239 W/kg = -6.22 dBW/kg




SAR Plots                                                                                  Plot 6#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic FDD-LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/LTE Band 5 1RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.571 W/kg

Body Back/LTE Band 5 1RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 22.79 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 0.961 W/kg
SAR(1 g) = 0.519 W/kg; SAR(10 g) = 0.287 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.586 W/kg




             0 dB = 0.586 W/kg = -2.32 dBW/kg




SAR Plots                                                                                   Plot 7#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic FDD-LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/LTE Band 5 50%RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.534 W/kg

Body Back/LTE Band 5 50%RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 20.93 V/m; Power Drift = -0.16 dB
Peak SAR (extrapolated) = 0.930 W/kg
SAR(1 g) = 0.461 W/kg; SAR(10 g) = 0.261 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.515 W/kg




             0 dB = 0.515 W/kg = -2.88 dBW/kg




SAR Plots                                                                                   Plot 8#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic FDD-LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/LTE Band 5 1RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.376 W/kg

Body Top/LTE Band 5 1RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 16.23 V/m; Power Drift = 0.09 dB
Peak SAR (extrapolated) = 0.611 W/kg
SAR(1 g) = 0.346 W/kg; SAR(10 g) = 0.168 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.388 W/kg




             0 dB = 0.388 W/kg = -4.11 dBW/kg




SAR Plots                                                                                   Plot 9#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic FDD-LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium parameters used (interpolated): f = 836.5 MHz; σ = 0.97 S/m; εr = 55.626; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(9.54, 9.54, 9.54) @ 836.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/LTE Band 5 50%RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.439 W/kg

Body Top/LTE Band 5 50%RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 16.15 V/m; Power Drift = 0.102 dB
Peak SAR (extrapolated) = 0.762 W/kg
SAR(1 g) = 0.376 W/kg; SAR(10 g) = 0.185 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.413 W/kg




             0 dB = 0.413 W/kg = -3.84 dBW/kg




SAR Plots                                                                                  Plot 10#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic TDD-LTE (0); Frequency: 2602.5 MHz;Duty Cycle: 1:1.58
Medium parameters used (interpolated): f = 2602.5 MHz; σ = 2.132 S/m; εr = 52.664; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(6.95, 6.95, 6.95) @ 2602.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/LTE Band 41 1RB Mid/Area Scan (101x121x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.889 W/kg

Body Back/LTE Band 41 1RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 9.769 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 1.87 W/kg
SAR(1 g) = 0.701 W/kg; SAR(10 g) = 0.290 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.799 W/kg




             0 dB = 0.799 W/kg = -0.97 dBW/kg




SAR Plots                                                                                 Plot 11#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic TDD-LTE (0); Frequency: 2602.5 MHz;Duty Cycle: 1:1.58
Medium parameters used (interpolated): f = 2602.5 MHz; σ = 2.132 S/m; εr = 52.664; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(6.95, 6.95, 6.95) @ 2602.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Back/LTE Band 41 50%RB Mid/Area Scan (101x141x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.807 W/kg

Body Back/LTE Band 41 50%RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 8.441 V/m; Power Drift = 0.06 dB
Peak SAR (extrapolated) = 1.60 W/kg
SAR(1 g) = 0.632 W/kg; SAR(10 g) = 0.262 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.723 W/kg




             0 dB = 0.723 W/kg = -1.41 dBW/kg




SAR Plots                                                                                 Plot 12#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic TDD-LTE (0); Frequency: 2602.5 MHz;Duty Cycle: 1:1.58
Medium parameters used (interpolated): f = 2602.5 MHz; σ = 2.132 S/m; εr = 52.664; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(6.95, 6.95, 6.95) @ 2602.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/LTE Band 41 1RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.284 W/kg

Body Top/LTE Band 41 1RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 10.25 V/m; Power Drift = 0.04 dB
Peak SAR (extrapolated) = 0.595 W/kg
SAR(1 g) = 0.248 W/kg; SAR(10 g) = 0.126 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.285 W/kg




             0 dB = 0.285 W/kg = -5.45 dBW/kg




SAR Plots                                                                                 Plot 13#


 Bay Area Compliance Laboratories Corp. (Shenzhen)                   Report No.: RSZ190107001-SA


DUT: Tata Tablet; Type: T101; Serial: 19010700102

Communication System: UID 0, Generic TDD-LTE (0); Frequency: 2602.5 MHz;Duty Cycle: 1:1.58
Medium parameters used (interpolated): f = 2602.5 MHz; σ = 2.132 S/m; εr = 52.664; ρ = 1000 kg/m3
Phantom section: Flat Section

DASY5 Configuration:

      Probe: EX3DV4 - SN7522; ConvF(6.95, 6.95, 6.95) @ 2602.5 MHz;
      Sensor-Surface: 4mm (Mechanical Surface Detection)
      Electronics: DAE4 Sn1562; Calibrated: 11/6/2018
      Phantom: ELI V8.0 P1aP2a; Type: QD OVA 004 AA; Serial: 2092
      Measurement SW: DASY52, Version 52.10 (2);



Body Top/LTE Band 41 50%RB Mid/Area Scan (101x131x1): Interpolated grid: dx=1.000 mm,
dy=1.000 mm
Maximum value of SAR (interpolated) = 0.230 W/kg

Body Top/LTE Band 41 50%RB Mid/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm,
dy=5mm, dz=5mm
Reference Value = 9.277 V/m; Power Drift = 0.02 dB
Peak SAR (extrapolated) = 0.495 W/kg
SAR(1 g) = 0.202 W/kg; SAR(10 g) = 0.096 W/kg (SAR corrected for target medium)
Maximum value of SAR (measured) = 0.234 W/kg




             0 dB = 0.234 W/kg = -6.31 dBW/kg