Test Report

FCC ID: 2ARRB-E52X75CH

Test Report

Download: PDF
FCCID_4374941

                                                FCC PART 15C

                                                 TEST REPORT
                                                                 For

                    Meizhou Guo Wei Electronics Co., Ltd
 AD1 Section, Economic Development Area, Dongsheng Industrial District, Meizhou, Guangdong, China


                                      FCC ID: 2ARRB-E52X75CH


              Report Type:                                        Product Type:
              Original Report                                     Digital Cordless Telephone



                   Report Number:            RSZ181218001-00


                        Report Date:         2019-01-17

                                             Rocky Kang

                       Reviewed By:          RF Engineer

                  Test Laboratory:           Bay Area Compliance Laboratories Corp. (Shenzhen)
                                             6/F., West Wing, Third Phase of Wanli Industrial
                                             Building, Shihua Road, Futian Free Trade Zone,
                                             Shenzhen, Guangdong, China
                                             Tel: +86-755-33320018
                                             Fax: +86-755-33320008
                                             www.baclcorp.com.cn




Note: This report must not be used by the customer to claim product certification, approval, or endorsement by A2LA* or any agency of
the Federal Government. * This report may contain data that are not covered by the A2LA accreditation and are marked with an asterisk
“*”.


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                          Report No.: RSZ181218001-00




                                                       TABLE OF CONTENTS


GENERAL INFORMATION .......................................................................................................................................3
 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................3
 OBJECTIVE ...................................................................................................................................................................3
 RELATED SUBMITTAL(S)/GRANT(S) .............................................................................................................................3
 TEST METHODOLOGY ..................................................................................................................................................3
 MEASUREMENT UNCERTAINTY ....................................................................................................................................4
 TEST FACILITY .............................................................................................................................................................4
SYSTEM TEST CONFIGURATION ..........................................................................................................................5
  JUSTIFICATION .............................................................................................................................................................5
  EUT EXERCISE SOFTWARE ..........................................................................................................................................5
  SUPPORT EQUIPMENT LIST AND DETAILS ....................................................................................................................5
  EXTERNAL I/O CABLE..................................................................................................................................................5
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................5
SUMMARY OF TEST RESULTS ...............................................................................................................................6

FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE) .............................................................7
  APPLICABLE STANDARD ..............................................................................................................................................7
  BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................8
  TEST EQUIPMENT LIST AND DETAILS ...........................................................................................................................8
  TEST DATA ..................................................................................................................................................................8
FCC§15.203 – ANTENNA REQUIREMENT ...........................................................................................................11
  APPLICABLE STANDARD ............................................................................................................................................11
  ANTENNA CONNECTED CONSTRUCTION ....................................................................................................................11
FCC §15.207 – AC LINE CONDUCTED EMISSION .............................................................................................12
  APPLICABLE STANDARD ............................................................................................................................................12
  EUT SETUP ................................................................................................................................................................12
  EMI TEST RECEIVER SETUP .......................................................................................................................................12
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................13
  TEST PROCEDURE ......................................................................................................................................................13
  CORRECTED FACTOR & MARGIN CALCULATION .......................................................................................................13
  TEST RESULTS SUMMARY ..........................................................................................................................................13
  TEST DATA ................................................................................................................................................................14
FCC §15.205 & §15.209 - RADIATED EMISSIONS TEST ....................................................................................19
  APPLICABLE STANDARD ............................................................................................................................................19
  EUT SETUP ................................................................................................................................................................19
  EMI TEST RECEIVER SETUP .......................................................................................................................................20
  CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................20
  TEST EQUIPMENT LIST AND DETAILS .........................................................................................................................20
  TEST RESULTS SUMMARY ..........................................................................................................................................21
  TEST DATA ................................................................................................................................................................21




FCC Part 15C                                                                                                                                              Page 2 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181218001-00

GENERAL INFORMATION
Product Description for Equipment Under Test (EUT)
The Meizhou Guo Wei Electronics Co., Ltd’s product, model number: Motorola O21-C
(FCC ID: 2ARRB-E52X75CH) in this report is a Digital Cordless Telephone, which was measured
approximately: 11.0 cm (L) * 7.9 cm (W) * 4.5 cm (H), rated with input voltage: DC 7.5V.

Adapter 1 Information:
Model: MN-A703-L145
Input: AC 100-240V, 50/60Hz, 0.2A
Output: DC 7.5V, 0.3A

Adapter 2 Information:
Model: HJ-0750300A1-US
Input: AC 100-240V, 50/60Hz, 0.15A
Output: DC 7.5V, 300 mA

* All measurement and test data in this report was gathered from production sample serial number: 181218001
(Assigned by BACL, Shenzhen). The EUT supplied by the applicant was received on 2018-12-18.


Objective
This report is prepared on behalf of Meizhou Guo Wei Electronics Co., Ltd in accordance with Part 2,
Subpart J, and Part 15, Subparts A and C of the Federal Communications Commission’s rules.

The objective is to determine the compliance of EUT with FCC rules, section 15.203, 15.205, 15.207 and
15.209.


Related Submittal(s)/Grant(s)
Submitted with PUE Handset unit submission with FCC ID: 2ARRB-E52X75HS and PUB base unit
submission with FCC ID: 2ARRB-E52X75BS.


Test Methodology
All measurements contained in this report were conducted with ANSI C63.10-2013, American National
Standard of Procedures for Compliance Testing of Unlicensed Wireless Devices.

All emissions measurement was performed at Bay Area Compliance Laboratories Corp. (Shenzhen). The
radiated testing was performed at an antenna-to-EUT distance of 3 meters.




FCC Part 15C                                                                                       Page 3 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                        Report No.: RSZ181218001-00

Measurement Uncertainty


                                      Item                                   Uncertainty
                     AC Power Line Conducted Emissions                         ±1.95 dB
                                                 9 kHz~30MHz                   ±4.52 dB
               Radiated emission
                                                 30MHz~1 GHz                   ±5.81 dB
                            Occupied Bandwidth                                 ±0.5 kHz
                                   Temperature                                 ±3.0 ℃
                                    Humidity                                    ±6 ℅


Test Facility
The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located
on the 6/F., West Wing, Third Phase of Wanli Industrial Building, Shihua Road, Futian Free Trade Zone,
Shenzhen, Guangdong, China.

The test site has been approved by the FCC under the KDB 974614 D01 and is listed in the FCC Public
Access Link (PAL) database, FCC Registration No.: 342867, the FCC Designation No.: CN1221.

The test site has been registered with ISED Canada under ISED Canada Registration Number 3062B.




FCC Part 15C                                                                                Page 4 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                              Report No.: RSZ181218001-00


SYSTEM TEST CONFIGURATION
Justification

The system was configured for testing in a test mode

The device is a wireless charger operation on frequency 150 kHz.


EUT Exercise Software

No software used in test.


Support Equipment List and Details


       Manufacturer           Description              Model                         Serial Number

         Guo Wei                Handset                O211                                N/A


External I/O Cable

                 Cable Description                  Length (m)              From Port                         To

          Shielded detachable USB cable                 1.0                   EUT                   Adapter


Block Diagram of Test Setup
For Conducted Emissions:

                                                            Handset
                                                                                                               LISN


                                                                      EUT     10cm
                                                                                         Socket
                                                                               Adapter
                                                                                                  1.0 meter




                Non-Conductive Table
                80 cm above Ground Plane

                                               1.5 meters

FCC Part 15C                                                                                                  Page 5 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                         Report No.: RSZ181218001-00

SUMMARY OF TEST RESULTS

               FCC Rules                       Description of Test                  Result
            FCC§1.1310 &
                                      Maximum Permissible Exposure(MPE)           Compliance
              §2.1091
               FCC§15.203                     Antenna Requirement                 Compliance
               FCC§15.207                 AC Line Conducted Emission              Compliance
            §15.209 §15.205                  Radiated Emission Test               Compliance




FCC Part 15C                                                                                 Page 6 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: RSZ181218001-00

FCC §1.1310, §2.1091- MAXIMUM PERMISSIBLE EXPOSURE (MPE)
Applicable Standard
According to subpart §1.1310, systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency energy level in excess of the
Commission’s guidelines.

Limits for Maximum Permissible Exposure (MPE) (§1.1310, §2.1091)

                         (B) Limits for General Population/Uncontrolled Exposure
Frequency Range        Electric Field       Magnetic Field        Power Density          Averaging Time
     (MHz)            Strength (V/m)        Strength (A/m)           (mW/cm2)              (minutes)
    0.3–1.34                614                     1.63               *(100)                   30
     1.34–30               824/f                    2.19/f            *(180/f²)                 30
     30–300                 27.5                    0.073                0.2                    30
    300–1500                 /                        /                 f/1500                  30
  1500–100,000               /                        /                  1.0                    30

f = frequency in MHz; * = Plane-wave equivalent power density;

According with KDB 680106 D01 RF Exposure Wireless Charging Apps v03 clause 3 c)




According to KDB 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b)




FCC Part 15C                                                                                  Page 7 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181218001-00

Block Diagram of Test Setup




                                                   15cm




Note: 20 cm for Top test.


Test Equipment List and Details

                                                                      Serial        Calibration    Calibration
     Manufacturer            Description            Model
                                                                     Number            Date         Due Date
         Narda          Exposure Level Tester       ELT-400           N-0215        2018-02-22     2019-02-21
                                                   ELT Probe
         Narda               B Field Probe                           M-0658         2018-02-22     2019-02-21
                                                     100cm2
     ETS-Lindgren           Isotropic Probe         HI-6005         00069461        2016-02-29     2019-02-28

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).


Test Data
     Environmental Conditions

             Temperature:                  24°C
        Relative Humidity:                 57 %
            ATM Pressure:              100.4 kPa

     The testing was performed by Kiki Kong on 2018-12-27.

      Test mode: Transmitting




FCC Part 15C                                                                                        Page 8 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                   Report No.: RSZ181218001-00

For Adapter 1:

H-Filed Strength
Frequency      Position    Position     Position      Position     Position       50%       Limit
  Range           A           B            C             D            E          Limit       Test
  (kHz)         (A/m)       (A/m)        (A/m)         (A/m)        (A/m)        (A/m)      (A/m)

    150         0.112        0.119        0.111        0.123         0.075        0.815      1.63


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

E-Filed Strength
Frequency      Position     Position     Position     Position      Position      50%        Limit
  Range           A            B            C            D             E         Limit        Test
  (kHz)         (V/m)        (V/m)        (V/m)        (V/m)         (V/m)       (V/m)       (V/m)

    150         2.882        2.45         2.917        4.162         2.312         307        614


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

Result: Compliance

For Adapter 2:

H-Filed Strength
Frequency      Position    Position     Position      Position     Position       50%       Limit
  Range           A           B            C             D            E          Limit       Test
  (kHz)         (A/m)       (A/m)        (A/m)         (A/m)        (A/m)        (A/m)      (A/m)

    150         0.103        0.116        0.101        0.119         0.073        0.815      1.63


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

E-Filed Strength
Frequency      Position     Position     Position     Position      Position      50%        Limit
  Range           A            B            C            D             E         Limit        Test
  (kHz)         (V/m)        (V/m)        (V/m)        (V/m)         (V/m)       (V/m)       (V/m)

    150         2.746        2.539        2.822        3.804         2.265         307        614


Note: Test with 15cm distance from the center of the probe(s) to the edge of the device, 20 cm for top test.

Result: Compliance




FCC Part 15C                                                                                             Page 9 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ181218001-00

Considerations of compliance 680106 D01 RF Exposure Wireless Charging App v03 clause 5 b:

(1) Power transfer frequency is less than 1 MHz.

Yes, the operation frequency is 150 kHz.

(2) Output power from each primary coil is less than or equal to 15 watts.

Yes, the maximum output power of primary coil is 2.5Watts, less than 15 watts.

(3) The transfer system includes only single primary and secondary coils. This includes charging systems
that may have multiple primary coils and clients that are able to detect and allow coupling only between
individual pairs of coils.

The transfer system includes only single primary coils to detect and allow coupling only between
individual pairs of coils.

(4) Client device is placed directly in contact with the transmitter.

Yes, client device is placed directly in contact with the transmitter

(5) Mobile exposure conditions only (portable exposure conditions are not covered by this exclusion).

Yes, mobile exposure conditions only

 (6) The aggregate H-field strengths at 15 cm surrounding the device and 20 cm above the top surface from
all simultaneous transmitting coils are demonstrated to be less than 50% of the MPE limit.

Yes, the test result for H and E-filed strength less than 50% of the MPE limit.




FCC Part 15C                                                                                  Page 10 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181218001-00

FCC§15.203 – ANTENNA REQUIREMENT
Applicable Standard
An intentional radiator shall be designed to ensure that no antenna other than that furnished by the
responsible party shall be used with the device. The use of a permanently attached antenna or of an
antenna that uses a unique coupling to the intentional radiator shall be considered sufficient to comply with
the provisions of this section.


Antenna Connected Construction
The EUT has a coil antenna arrangement, which was permanently attached, fulfill the requirement of this
section. Please refer to the EUT photos.

Result: Compliance.




FCC Part 15C                                                                                    Page 11 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: RSZ181218001-00

FCC §15.207 – AC LINE CONDUCTED EMISSION
Applicable Standard
FCC§15.207


EUT Setup




The setup of EUT is according with per ANSI C63.10-2013 measurement procedure. The specification
used was with the FCC Part 15.207 limits.

The spacing between the peripherals was 10 cm.


EMI Test Receiver Setup
The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz.

During the conducted emission test, the EMI test receiver was set with the following configurations:

                              Frequency Range                      IF B/W
                              150 kHz – 30 MHz                      9 kHz




FCC Part 15C                                                                                  Page 12 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                    Report No.: RSZ181218001-00

Test Equipment List and Details

                                                                        Serial         Calibration   Calibration
      Manufacturer              Description            Model
                                                                       Number             Date        Due Date
     Rohde & Schwarz         EMI Test Receiver         ESCS30              100176       2018-07-11   2019-07-11
                                                                     3560.6650.12-
     Rohde & Schwarz               LISN               ENV216                            2018-12-21   2019-12-21
                                                                      101613-Yb
     Rohde & Schwarz         Transient Limiter        ESH3Z2           DE25985          2018-11-12   2019-11-12
     Rohde & Schwarz         CE Test software          EMC 32              V8.53.0        NCR           NCR
                            Conducted Emission                       UF A210B-1-
         Unknown                                        78652                           2018-11-12   2019-11-12
                                  Cable                              0720-504504

* Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations have
been performed, traceable to National Primary Standards and International System of Units (SI).


Test Procedure
During the conducted emission test, the adapter was connected to the outlet of the LISN.

Maximizing procedure was performed on the six (6) highest emissions of the EUT.

All final data was recorded in the Quasi-peak and average detection mode.


Corrected Factor & Margin Calculation
The Corrected factor is calculated by adding LISN VDF (Voltage Division Factor), Cable Loss and
Transient Limiter Attenuation. The basic equation is as follows:

      Correction Factor = LISN VDF + Cable Loss + Transient Limiter Attenuation

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7 dB means the emission is 7 dB below the limit. The equation for margin
calculation is as follows:

      Margin = Limit – Corrected Amplitude


Test Results Summary
According to the recorded data in following table, the EUT complied with the FCC Part 15.207,


Refer to CISPR16-4-2:2011 and CISPR 16-4-1:2009, the measured level complies with the limit if

                                              Lm + U(Lm) ≤ Llim + Ucispr

In BACL, U(Lm) is less than Ucispr, if Lm is less than Llim, it implies that the EUT complies with the limit.




FCC Part 15C                                                                                          Page 13 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)             Report No.: RSZ181218001-00

Test Data
     Environmental Conditions

                Temperature:          24°C
         Relative Humidity:           57 %
               ATM Pressure:        100.4 kPa

      The testing was performed by Haiguo Li on 2018-12-27.

     Test Mode: charging




FCC Part 15C                                                                   Page 14 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181218001-00

For Adapter 1:
     AC 120 V/60 Hz, Line:


                         90

                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50

                         40


                         30

                         20


                         10

                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.150000               49.7           19.8             66.0          16.3          QP
           0.205500               45.3           19.7             63.4          18.1          QP
           0.217500               43.7           19.7             62.9          19.2          QP
           0.423670               45.5           19.7             57.4          11.9          QP
           3.457410               39.0           20.0             56.0          17.0          QP
           3.962210               37.4           20.0             56.0          18.6          QP
           0.150000               39.8           19.8             56.0          16.2          Ave.
           0.205500               34.6           19.7             53.4          18.8          Ave.
           0.217500               33.2           19.7             52.9          19.7          Ave.
           0.423670               39.6           19.7             47.4          7.8           Ave.
           3.457410               30.2           20.0             46.0          15.8          Ave.
           3.962210               27.6           20.0             46.0          18.4          Ave.




FCC Part 15C                                                                                         Page 15 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181218001-00


     AC 120V/ 60 Hz, Neutral:



                         90


                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.189500               44.8           19.7             64.1          19.3          QP
           0.309350               44.3           19.8             60.0          15.7          QP
           0.344750               36.6           19.7             59.1          22.5          QP
           0.348690               36.0           19.7             59.0          23.0          QP
           0.419610               40.5           19.7             57.5          17.0          QP
           3.837210               36.3           19.9             56.0          19.7          QP
           0.189500               32.9           19.7             54.1          21.2          Ave.
           0.309350               38.4           19.8             50.0          11.6          Ave.
           0.344750               31.1           19.7             49.1          18.0          Ave.
           0.348690               30.1           19.7             49.0          18.9          Ave.
           0.419610               31.2           19.7             47.5          16.3          Ave.
           3.837210               27.4           19.9             46.0          18.6          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude
FCC Part 15C                                                                                         Page 16 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181218001-00


For Adapter 2:
     AC 120 V/60 Hz, Line:


                         90


                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.158000               51.2           19.8             65.6          14.4          QP
           0.181500               47.9           19.8             64.4          16.5          QP
           0.309350               44.0           19.8             60.0          16.0          QP
           0.340930               44.1           19.7             59.2          15.1          QP
           0.360570               45.1           19.7             58.7          13.6          QP
           0.388150               40.1           19.7             58.1          18.0          QP
           0.158000               43.1           19.8             55.6          12.5          Ave.
           0.181500               37.3           19.8             54.4          17.1          Ave.
           0.309350               37.7           19.8             50.0          12.3          Ave.
           0.340930               37.0           19.7             49.2          12.2          Ave.
           0.360570               39.4           19.7             48.7          9.3           Ave.
           0.388150               34.7           19.7             48.1          13.4          Ave.




FCC Part 15C                                                                                         Page 17 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                Report No.: RSZ181218001-00


     AC 120V/ 60 Hz, Neutral:



                         90


                         80


                         70

                                                                                                   QP
                         60
          Level in dBμ




                                                                                                     AV
                         50


                         40


                         30


                         20


                         10


                         0
                         150k   300 400 500   800 1M        2M     3M 4M 5M 6     8 10M      20M     30M
                                                        Frequency in Hz



                                Corrected     Correction
         Frequency                                                Limit     Margin          Detector
                                Amplitude      Factor
           (MHz)                                                 (dBμV)      (dB)         (PK/Ave./QP)
                                 (dBμV)         (dB)
           0.153500               52.3           19.8             65.8          13.5          QP
           0.165500               51.4           19.7             65.2          13.8          QP
           0.193500               47.4           19.7             63.9          16.5          QP
           0.290500               45.0           19.8             60.5          15.5          QP
           0.340930               45.3           19.7             59.2          13.9          QP
           0.360570               45.3           19.7             58.7          13.4          QP
           0.153500               40.5           19.8             55.8          15.3          Ave.
           0.165500               37.1           19.7             55.2          18.1          Ave.
           0.193500               35.6           19.7             53.9          18.3          Ave.
           0.290500               39.6           19.8             50.5          10.9          Ave.
           0.340930               37.1           19.7             49.2          12.1          Ave.
           0.360570               38.1           19.7             48.7          10.6          Ave.

     Note:
     1) Correction Factor =LISN VDF (Voltage Division Factor) + Cable Loss + Transient Limiter Attenuation
     2) Corrected Amplitude = Reading + Correction Factor
     3) Margin = Limit – Corrected Amplitude
FCC Part 15C                                                                                         Page 18 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                 Report No.: RSZ181218001-00

FCC §15.205 & §15.209 - RADIATED EMISSIONS TEST
Applicable Standard
As per FCC Part 15.209

 (a) Except as provided elsewhere in this subpart, the emissions from an intentional radiator shall not
exceed the field strength levels specified in the following table:

  Frequency (MHz)            Field strength (microvolts/meter)              Measurement distance (meters)
      0.009-0.490                        2400/F(kHz)                                        300
      0.490-1.705                        24000/F(kHz)                                        30
      1.705-30.0                               30                                            30
         30-88                               100**                                           3
        88-216                               150**                                           3
        216-960                              200**                                           3
      Above 960                               500                                            3
      **Except as provided in paragraph (g), fundamental emissions from intentional radiators operating under this
section shall not be located in the frequency bands 54-72 MHz, 76-88 MHz, 174-216 MHz or 470-806 MHz.
However, operation within these frequency bands is permItted under other sections of this part, e.g., §§15.231 and
15.241.


EUT Setup




The radiated emission tests were performed in the 3-meter chamber test site, using the setup accordance
with the ANSI C63.10-2013. The specification used was the FCC Part Subpart C limits.

The spacing between the peripherals was 10 cm.




FCC Part 15C                                                                                          Page 19 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                               Report No.: RSZ181218001-00


EMI Test Receiver Setup
The system was investigated from 9 kHz to 1 GHz.

During the radiated emission test, the EMI test Receiver was set with the following configurations:

                       Frequency Range              RBW          Video B/W       Measurement
                        9 kHz – 150 kHz            200 Hz           1 kHz         QP/Average
                       150 kHz – 30 MHz             9 kHz           30 kHz        QP/Average
                      30 MHz – 1000 MHz            120 kHz         300 kHz            QP

The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9-90 kHz, 110-490 kHz and above 1000 MHz. Radiated emission
limits in these three bands are based on measurements employing an average detector.

If the maximized peak measured value complies with the limit, then it is unnecessary to perform an
QP/Average measurement


Corrected Amplitude & Margin Calculation
The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the
Amplifier Gain from the Amplitude reading. The basic equation is as follows:

                  Corr. Ampl. = Meter Reading + Antenna Factor + Cable Loss - Amplifier Gain

The “Margin” column of the following data tables indicates the degree of compliance with the applicable
limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin
calculation is as follows:

                                           Margin = Limit - Corr. Ampl.

Test Equipment List and Details

                                                                     Serial       Calibration     Calibration
     Manufacturer             Description             Model
                                                                    Number           Date          Due Date

   Sonoma instrument           Amplifier              310N           186238        2018-11-12      2019-11-12

   Rohde & Schwarz         EMI Test Receiver          ESCI           101120        2018-01-11      2019-01-11
     Sunol Sciences        Broadband Antenna           JB1         A040904-1       2017-12-22      2020-12-21
          ETS            Passive Loop Antenna         6512           29604         2018-03-07      2021-03-06
          TDK                   Chamber            Chamber A              2#       2016-12-05      2019-12-05
      UTiFLEX                                       UFA147A-       MFR64639
                                RF Cable                                           2018-07-11      2021-07-10
     MICRO-C0AX                                    2362-100100     231029-003
       Ducommun
                                RF Cable             104PEA        218124002       2018-11-12      2019-11-12
      technologies

    * Statement of Traceability: Bay Area Compliance Laboratories Corp. (Shenzhen) attests that all calibrations
     have been performed, traceable to National Primary Standards and International System of Units (SI).

FCC Part 15C                                                                                        Page 20 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                            Report No.: RSZ181218001-00

Test Results Summary
According to the data in the following table, the EUT complied with the FCC Part 15.209&15.205.


Test Data
     Environmental Conditions

              Temperature:             26 oC
          Relative Humidity:           57 %
             ATM Pressure:           100.7 kPa

     The testing was performed by Andy Yu on 2018-12-22.

    Test mode: Transmitting

For Adapter 1

1) 9 kHz~30MHz:

                                                                                  FCC Part
Frequency Corrected            Turntable Rx Antenna            Corrected
                      Detector                                                  15.205&15.209
          Amplitude                                             Factor                            Remark
                    (PK/QP/AV)          Height                                Limit    Margin
  (MHz) (dBμV/m)                Degree         Polar             (dB/m)
                                         (m)                               (dBμV/m)      (dB)
 0.009564   48.90       PK       199      1      H               87.8        127.99     79.09     Spurious
  0.4485       59.48           PK     261        1         H     65.7       94.57      35.09      emission

   0.15        82.46           PK     261        1         H     87.8       124.08     41.62    Fundamental




FCC Part 15C                                                                                    Page 21 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                              Report No.: RSZ181218001-00

                                                          9 kHz-150 kHz
                                                               * RBW 300 Hz   Marker 1 [T1 ]
                                                                VBW 1 kHz               48.90 dBµV
                         Ref   130 dBµV       * Att   40 dB     SWT 1.6 s          9.564000000 kHz
                         130
                         9K-150K
                                                                                                      A
                         120

                  1 PK
                  MAXH
                         110


                                                                                                     TDF
                         100


                                                                                                     PS
                         90



                         80

                                                                                                     3DB
                         70                                                                          AC



                         60


                         1
                         50



                         40


                         30

                         Start 9 kHz                      14.1 kHz/                   Stop 150 kHz




                  EUT
                  Date: 22.DEC.2018       16:03:04




                                                        150 kHz-30 MHz
                                                               * RBW 10 kHz   Marker 1 [T1 ]
                                                                VBW 30 kHz              59.48 dBµV
                         Ref   102 dBµV       * Att   10 dB     SWT 300 ms       448.500000000 kHz
                         100
                         150K-30M
                                                                                                      A
                         90
                  1 PK
                  MAXH
                         80

                                                                                                     TDF
                         70

                                                                                                     PS
                         1
                         60



                         50
 Fundamental                                                                                         3DB
                                                                                                     AC
                         40



                         30



                         20



                         10



                         Start 150 kHz                   2.985 MHz/                    Stop 30 MHz




                  EUT
                  Date: 22.DEC.2018       15:59:25




FCC Part 15C                                                                                                    Page 22 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                   Report No.: RSZ181218001-00

2) 30 MHz ~ 1GHz



                          80



                          70



                          60
                                                                            Electric Field Strength QP-3m

                          50
         Level in dBμV/




                          40



                          30



                          20



                          10



                           0
                           30M         50    60      80   100M                200         300      400      500           800    1G
                                                                     Frequency in Hz




                                 Corrected    Antenna                     Turntable        Correction
     Frequency                                              Antenna                                             Limit           Margin
                                 Amplitude     height                      position         Factor
       (MHz)                                                Polarity                                          (dBμV/m)           (dB)
                                 (dBμV/m)       (cm)                       (degree)         (dB/m)

     36.239625                     30.41          107.0          V            36.0              -11.3             40.00          9.59
     60.417375                     26.72          100.0          V            38.0              -20.2             40.00          13.28
     84.473125                     23.87          151.0          V            20.0              -19.5             40.00          16.13
     135.031875                    39.37          178.0          H            60.0              -13.9             43.50          0.63
     204.812625                    38.96          174.0          H           132.0              -13.9             43.50          4.54
     206.058750                    39.49          169.0          H           122.0              -13.9             43.50          4.01




FCC Part 15C                                                                                                                    Page 23 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                     Report No.: RSZ181218001-00

For Adapter 2

1) 9 kHz~30 MHz:

                                                                           FCC Part
Frequency Corrected            Turntable Rx Antenna     Corrected
                      Detector                                          15.205&15.209
          Amplitude                                      Factor                            Remark
                    (PK/QP/AV)          Height                        Limit     Margin
  (MHz) (dBμV/m)                Degree         Polar      (dB/m)
                                         (m)                        (dBμV/m)     (dB)
 0.009846   49.44       PK       191      1      H        87.8        127.74     78.30     Spurious
  0.4485       60.68      PK         237        1   H     65.7        94.57     33.89      emission

   0.15        82.98      PK         261        1   H     87.8       124.08     41.10    Fundamental




FCC Part 15C                                                                             Page 24 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                              Report No.: RSZ181218001-00

                                                          9 kHz-150 kHz
                                                               * RBW 300 Hz   Marker 1 [T1 ]
                                                                VBW 1 kHz               49.44 dBµV
                         Ref   130 dBµV       * Att   40 dB     SWT 1.6 s          9.846000000 kHz
                         130
                         9K-150K
                                                                                                      A
                         120

                  1 PK
                  MAXH
                         110


                                                                                                     TDF
                         100


                                                                                                     PS
                         90



                         80

                                                                                                     3DB
                         70                                                                          AC



                         60


                         1
                         50



                         40


                         30

                         Start 9 kHz                      14.1 kHz/                   Stop 150 kHz




                  EUT
                  Date: 22.DEC.2018       16:04:53




                                                        150 kHz-30 MHz
                                                               * RBW 10 kHz   Marker 1 [T1 ]
                                                                VBW 30 kHz              60.68 dBµV
                         Ref   102 dBµV       * Att   10 dB     SWT 300 ms       448.500000000 kHz
                         100
                         150K-30M
                                                                                                      A
                         90
                  1 PK
                  MAXH
                         80

                                                                                                     TDF
                         70

                                                                                                     PS
                         1
                         60


 Fundamental             50
                                                                                                     3DB
                                                                                                     AC
                         40



                         30



                         20



                         10



                         Start 150 kHz                   2.985 MHz/                    Stop 30 MHz




                  EUT
                  Date: 22.DEC.2018       16:06:55




FCC Part 15C                                                                                                    Page 25 of 26


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                     Report No.: RSZ181218001-00

2) 30 MHz ~ 1GHz



                          80



                          70



                          60
                                                                             Electric Field Strength QP-3m

                          50
         Level in dBμV/




                          40



                          30



                          20



                          10



                           0
                           30M         50    60      80   100M                200        300      400    500           800    1G
                                                                     Frequency in Hz




                                 Corrected    Antenna                     Turntable       Correction
     Frequency                                              Antenna                                            Limit         Margin
                                 Amplitude     height                      position        Factor
       (MHz)                                                Polarity                                         (dBμV/m)         (dB)
                                 (dBμV/m)       (cm)                       (degree)        (dB/m)

     57.941875                     26.47          100.0          V           126.0             -20.1           40.00          13.53
     65.614375                     35.64          100.0          V           282.0             -20.4           40.00          4.36
     145.606500                    38.29          203.0          H            62.0             -14.2           43.50          5.21
     152.601625                    39.80          224.0          H            58.0             -14.3           43.50          3.70
     210.718000                    34.44          149.0          H           121.0             -13.9           43.50          9.06
     827.265250                    36.18          239.0          H           113.0              4.6            46.00          9.82

Note:
Corrected Amplitude = Corrected Factor + Reading
Corrected Factor=Antenna factor (RX) + cable loss - amplifier factor
Margin = Limit- Corr. Amplitude

Result: Compliance

                                                  ***** END OF REPORT *****

FCC Part 15C                                                                                                                 Page 26 of 26



Document Created: 2019-07-23 18:20:32
Document Modified: 2019-07-23 18:20:32

© 2024 FCC.report