FCC_ID_Report

FCC ID: 2AROV-GPMB10

Test Report

Download: PDF
FCCID_4189829

                                                                                    Date of Issue: January 23, 2019
                            WH Technology Corp.                                     Report No. : WH-FCC-R18112104
                                                                                    FCC ID. : 2AROV-GPMB10




                             FCC 47 CFR PART 15 SUBPART C
                                     TEST REPORT

                                                         FOR

    GRENOPLUS IMATE ALL IN ONE DOCKING STATION (60W)

                                             Model : GP-MB10

                                                       Issued to

                   GRENO TECHNOLOGY (HK) CO., LTD
       ROOM 603, 6/F,HANG PONT COMMERCIAL BUILDING, 31 TONKIN
           STREET,CHEUNG SHA WAN, KOWLOON HONGKONG
                              Issued by
                          WH Technology Corp.




             Open Site           No.120, Ln. 5, Hudong St., Xizhi Dist., New
                                 Taipei City 221, Taiwan (R.O.C.)
      EMC           Xizhi Office 7F., No.262, Sec. 3, Datong Rd., Xizhi Dist., New
      Test           and Lab Taipei City 221, Taiwan (R.O.C.)
      Site
                              Tel.: +886-7729-7707 Fax: +886-2- 8648-1311

Note: This test refers exclusively to the test presented test model and sample. This report shall not be reproduced except in
full, without the written approval of WH Technology Corp.. This document may be altered or revised by WH Technology
Corp.. Personnel only, and shall be noted in the revision section of the document.




                                                        Page 1/21


                                                                                                                  Date of Issue: January 23, 2019
                                WH Technology Corp.                                                               Report No. : WH-FCC-R18112104
                                                                                                                  FCC ID. : 2AROV-GPMB10




1. GENERAL INFORMATION..................................................................................................................................3
2. REPORT OF MEASUREMENTS AND EXAMINATIONS............................................................................... 4
   2.1 LIST OF MEASUREMENTS AND EXAMINATIONS....................................................................................................4
3. TEST CONFIGURATION OF EQUIPMENT UNDER TEST............................................................................5
   3.1 DESCRIPTION OF THE TESTED SAMPLES............................................................................................ 5
   3.3 TEST MODE AND TEST SOFTWARE......................................................................................................... 5
   3.4 TEST METHODOLOGY & GENERAL TEST PROCEDURES..................................................................6
4. TEST AND MEASUREMENT EQUIPMENT....................................................................................................... 8
   4.1 CALIBRATION................................................................................................................................................... 8
   4.2 EQUIPMENT...................................................................................................................................................... 8
5. ANTENNA REQUIREMENTS............................................................................................................................. 10
   5.1 STANDARD APPLICABLE............................................................................................................................ 10
   5.2 ANTENNA CONSTRUCTION AND DIRECTIONAL GAIN....................................................................... 10
6. TEST OF CONDUCTED EMISSION..................................................................................................................11
   6.1 TEST LIMIT...................................................................................................................................................... 11
   6.2 TEST PROCEDURES.................................................................................................................................... 11
   6.3 TYPICAL TEST SETUP................................................................................................................................. 12
   6.4 TEST RESULT AND DATA........................................................................................................................... 13
7. TEST OF RADIATED EMISSION...................................................................................................................... 15
   7.1 TEST LIMIT......................................................................................................................................................... 15
   7.2 TEST PROCEDURES............................................................................................................................................. 15
   7.3 TYPICAL TEST SETUP......................................................................................................................................... 16
   7.4 TEST RESULT AND DATA (9KHZ ~ 30MHZ)...................................................................................................... 17
   7.5 TEST RESULT AND DATA (30MHZ ~ 1GHZ, WORST EMISSIONS FOUND)...........................................................19
8. RESTRICTED BANDS OF OPERATION.......................................................................................................... 21
   8.1 LABELING REQUIREMENT...................................................................................................................................21




                                                                         Page 2/21


                                                               Date of Issue: January 23, 2019
                         WH Technology Corp.                   Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




1.       GENERAL INFORMATION
Applicant            :   GRENO TECHNOLOGY (HK) CO., LTD
Address              :   ROOM 603, 6/F,HANG PONT COMMERCIAL BUILDING, 31
                         TONKIN STREET,CHEUNG SHA WAN, KOWLOON
                         HONGKONG
Manufacturer         :   GRENO TECHNOLOGY (HK) CO., LTD
Address              :   ROOM 603, 6/F,HANG PONT COMMERCIAL BUILDING, 31
                         TONKIN STREET,CHEUNG SHA WAN, KOWLOON
                         HONGKONG
Factory              :   Stiger International Trade Investment Co.,Ltd
Address              :   2 Building, Standard Garden, Taishi Industrial Zone, Dongyong
                         Town, Nansha District Guangzhou, Guangdong, P.R.China
EUT                  :   Grenoplus iMate All in One Docking Station (60w)
Model Name           :   GP-MB10
FCC ID               :   2AROV-GPMB10
Trade Name           :   iMate
Model                :   N/A
Differences




 Is here with confirmed to comply with the requirements set out in the FCC Rules and
 Regulations Part 15 Subpart C and the measurement procedures were according to
 ANSI C63.10-2013. The said equipment in the configuration described in this report
 shows the maximum emission levels emanating
FCC part 15 Subpart C
Receipt Date : 11/01/2018                    Final Test Date :12/30/2018


Tested By:                                                        Reviewed by:



Nov. 01, 2018                                Dec. 30, 2018
(Date)               Bing Chang/ Engineer    (Date)                    Bell Wei / Manager
                                                                   Designation Number: TW2954



                                            Page 3/21


                                                         Date of Issue: January 23, 2019
                      WH Technology Corp.                Report No. : WH-FCC-R18112104
                                                         FCC ID. : 2AROV-GPMB10




2.         REPORT OF MEASUREMENTS AND EXAMINATIONS
     2.1    LIST OF MEASUREMENTS AND EXAMINATIONS


                         FCC Rule                      Item              Result

                           15.207               Conducted Emission        PASS
                           15.205
                                                 Radiated Emission        PASS
                           15.209
                           15.203               Antenna Requirement       PASS




                                    Page 4/21


                                                              Date of Issue: January 23, 2019
                       WH Technology Corp.                    Report No. : WH-FCC-R18112104
                                                              FCC ID. : 2AROV-GPMB10




3.     TEST CONFIGURATION OF EQUIPMENT UNDER TEST
     3.1 DESCRIPTION OF THE TESTED SAMPLES

          Test Model         : GP-MB10
          Input              : AC 100-240V 1.8A (Max)
          Output C1          : DC 20V/2A,15V/2A,9V/2A & 5.2V/2A(Max)(PD)
          Output C2          : DC 9V/1A & 5.2V/2.4A(Max)(PD)
          USB 2.0 & 3.0      : 5.2V/2.4A (Max)
          Wireless Dongles : 500mA
          Output C1 & 2      : ThunderBolt 10Gb/s
          USB 2.0            : 480Mbps
          USB 3.0            : 5Gb/s
          High Definition MI : 4K 30Hz
          SD Card            : 104Mbp/s
          Operate            : 110KHz-200KHz
          Frequency
          Antenna Type       : Coil Antenna
          Antenna gain       : 0dBi


     3.2 TEST MODE AND TEST SOFTWARE

         a. During testing, the interface cables and equipment positions were varied
         according to ANSI C63.10-2013.

         b. The complete test system included Notebook and EUT for RF test.

         c. only the worst case was recorded in this report




                                           Page 5/21


                                                         Date of Issue: January 23, 2019
                 WH Technology Corp.                     Report No. : WH-FCC-R18112104
                                                         FCC ID. : 2AROV-GPMB10




 3.3 TEST METHODOLOGY & GENERAL TEST PROCEDURES

     All testing as described bellowed were performed in accordance with ANSI
     C63.10:2013 and FCC CFR 47 Part 15 Subpart C .

    Conducted Emissions

     The EUT is placed on a wood table, which is at 0.8 m above ground plane
     acceding to clause 15.207 and requirements of ANSI C63.10:2013. Conducted
     emissions from the EUT measured in the frequency range between 0.15 MHz and
     30MHz are using CISPR Quasi-Peak / Average detectors.

    Radiated Emissions

     The EUT is a placed on a turn table, which is 0.8 m above ground plane. The
     turntable was rotated through 360 degrees to determine the position of maximum
     emission level. The EUT is placed at 3m away from the receiving antenna, which
     varied from 1m to 4m to find out the highest emission. Each emission was to be
     maximized by changing the polarization of receiving antenna both horizontal and
     vertical.

     1)Putting the EUT on the platform and turning on the EUT (on/off button on the
     bottom of the EUT).
     2)Setting test channel described as “Channel setting and operating condition”,
     and testing channel by channel.
     3)For the maximum output power measurement, we followed the method of
     measurement ANSI C63.10.
     4)For the spurious emission test based on ANSI C63.10, at the frequency where
     below 1GHz used quasi-peak detector mode; where above 1GHz used the peak
     and average detector mode. IF the peak value may be under average limit, the
     average mode will not be performed.

3.4 MEASUREMENT UNCERTAINTY

      Measurement Item                             Uncertainty
      Radiated emission                            ±4.11dB
      Peak Output Power(conducted)                 ±1.38dB
      Peak Output Power(Radiated)                  ±1.70dB
      Power Spectral Density                       ±1.39dB
      Radiated emission(3m)                        ±4.11dB
      Radiated emission(10m)                       ±3.89dB

                                     Page 6/21


                                                            Date of Issue: January 23, 2019
                   WH Technology Corp.                      Report No. : WH-FCC-R18112104
                                                            FCC ID. : 2AROV-GPMB10




3.5 DESCRIPTION OF THE SUPPORT EQUIPMENTS

    Setup Diagram

      See test photographs attached in appendix 1 for the actual connections between
      EUT and support equipment.




    Support Equipment

      Peripherals Devices:

       Description           Manufacturer   Model No.        Serial No.
       Laptop                DELL           Latutude 3379    F3M13F2
       iWatch                Apple          Watch 3          FH7W260JJ5X4
       Phone                 HUAWEI         Mate10           BLA-AL00
       TV                    SONY           KDL-32W600D      2047973
       Adapter               SONY           ACDP-04S03       149345210157413
       SD Card               Kingston       U1 C10           N/A
       USB flash disk        Kingston       DTSE9EG2         N/A
       USB flash disk        Kingston       DTSE9EG2         N/A

       Type C Line              :   Unshielded ,Detachable, 0.2m
       Type C Line              :   Unshielded ,Detachable, 1.5m
       HDMI Line                :   Shielded ,Detachable, 1.8m

      Note: All the above equipment /cable were placed in worse case position to
      maximize emission signals during emission test

      Grounding: Grounding was in accordance with the manufacturer’s requirement
      and conditions for the intended use.

                                        Page 7/21


                                                                  Date of Issue: January 23, 2019
                         WH Technology Corp.                      Report No. : WH-FCC-R18112104
                                                                  FCC ID. : 2AROV-GPMB10



4.         TEST AND MEASUREMENT EQUIPMENT
     4.1    CALIBRATION

            The measuring equipment utilized to perform the tests documented in the report
            has been calibrated once a year or in accordance with the manufacturer ’ s
            recommendations, and is traceable to recognized national standards.

     4.2    EQUIPMENT

            The following list contains measurement equipment used for testing. The
            equipment conforms to the requirement of CISPR 16-1, ANSI C63.2 and. Other
            required standards. Calibration of all test and measurement, including any
            accessories that may effect such calibration, is checked frequently to ensure the
            accuracy. Adjustments are made and correction factors are applied in accordance
            with the instructions contained in the respective.




                                             Page 8/21


                                                      Date of Issue: January 23, 2019
                     WH Technology Corp.              Report No. : WH-FCC-R18112104
                                                      FCC ID. : 2AROV-GPMB10



       TABLELIST OF TEST AND MEASUREMENT EQUIPMENT

                                                                         Next Cal.
         Instrument             Manufacturer     Model No.       S/N
                                                                           Date
        EMI Receiver                R&S           ESHS10     830223/008 2019/06/05
                                 Rolf Heine
            LISN                                 NNB-2/16z     98062    2019/06/10
                             Hochfrequenztechnik
                                                 8-Wire ISN CAT5-8158-
             ISN                Schwarzbeck                             2019/09/20
                                                    CAT5        0094
          RF Cable                   N/A             N/A       EMI-3    2019/10/18
                                                 MCTD2786 BLB16M040
    Bilog antenna(30M-1G)           ETC                                 2019/05/17
                                                      B     04/JB-5-004
  Double Ridged Guide Horn                                  DRH15N020
                                    ETC          MCTD 1209              2019/11/10
      antenna(1G-18G)                                            09
   Horn antenna (18G-26G)        com-power         AH-826      81000    2019/08/15
  LOOP Antenna (Below 30M)       com-power        AL-130        17117      2019/10/03
    Pre amplifier (30M-1G)   EMC INSTRUMENT      EMC9135     980334 2019/05/02
                                               EMC05184 980108&AT
Microwave Preamplifier (1G-18G) EMC INSTRUMENT                        2019/10/22
                                                     5       -18001
                                               JS4-180026
    Pre amplifier (18G~26G)          MITEQ                   808329 2019/08/08
                                                 00-30-5A
                                                 ESVS30
       EMI Test Receiver              R&S       (20M-1000 826006/002 2019/11/10
                                                   MHz)
                                                N male on
                                               end of both
      RF Cable (open site)            EMCI                    30m     2019/10/18
                                                   sides
                                                  (EMI4)
                                   HARBOUT      LL142MI(4
      RF CABLE (1~26G)                                         NA     2019/04/16
                                  INDUSTRIES      M+4M)
                                   HARBOUT      LL142MI(7
      RF CABLE (1~26G)                                         NA     2019/08/08
                                  INDUSTRIES        M)
     Spectrum (9K--7GHz)              R&S          FSP7    830180/006 2019/04/13
    Spectrum (9K--40GHz)          AGILENT         8564EC     4046A0032 2019/03/01
            e3                     AUDIX            N/A         N/A        N/A
   SINGAL GENTERATOR                                         3619U0042
                                    HP             8648A                   N/A
       (100k-1GHz)                                               6
       Power Meter               ANRITSU          ML2487     6K00001574 2019/08/08


       *CALIBRATION INTERVAL OF INSTRUMENTS LISTED ABOVE IS ONE YEAR

                                    Page 9/21


                                                                Date of Issue: January 23, 2019
                        WH Technology Corp.                     Report No. : WH-FCC-R18112104
                                                                FCC ID. : 2AROV-GPMB10




5.         ANTENNA REQUIREMENTS
     5.1    STANDARD APPLICABLE

            According to the FCC Part 15 Paragraph 15.203, an intentional radiator shall be
            designed to ensure that no antenna other than that furnished by the responsible
            party shall be used with the device.

     5.2    ANTENNA CONSTRUCTION AND DIRECTIONAL GAIN

                               WPC
             Antenna Type    : Coil Antenna
             Antenna Gain    : 0 dBi




                                              Page 10/21


                                                                  Date of Issue: January 23, 2019
                          WH Technology Corp.                     Report No. : WH-FCC-R18112104
                                                                  FCC ID. : 2AROV-GPMB10



6.         TEST OF CONDUCTED EMISSION
     6.1    TEST LIMIT

             Conducted Emissions were measured from 150 kHz to 30 MHz with a bandwidth of
             9 KHz on the 120 VAC power and return leads of the EUT according to the
             methods defined in ANSI C63.10-2013 The EUT was placed on a nonmetallic
             stand in a shielded room 0.8 meters above the ground plane as shown in section
             2.2. The interface cables and equipment positioning were varied within limits of
             reasonable applications to determine the position produced maximum conducted
             emissions.
             The setup of EUT is according with per ANSI C63.10-2013 measurement
             procedure.The specification used was with the FCC Part 15.207 limits




              *Decreases with the logarithm of the frequency.

     6.2    TEST PROCEDURES

            a. The EUT was placed 0.4 meter from the conducting wall of the shielding room
               was kept at least 80 centimeters from any other grounded conducting surface.
            b. Connect EUT to the power mains through a line impedance stabilization network
               (LISN).
            c. All the support units are connecting to the other LISN.
            d. The LISN provides 50 ohm coupling impedance for the measuring instrument.
            e. The FCC states that a 50 ohm, 50 micro-Henry LISN should be used.
            f. Both sides of AC line were checked for maximum conducted interference.
            g. The frequency range from 150 kHz to 30 MHz was searched.
            h. Set the test-receiver system to Peak Detect Function and Specified Bandwidth
               with Maximum Hold Mode.




                                              Page 11/21


                                        Date of Issue: January 23, 2019
                WH Technology Corp.     Report No. : WH-FCC-R18112104
                                        FCC ID. : 2AROV-GPMB10




6.3   TYPICAL TEST SETUP




                           Page 12/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




  6.4   TEST RESULT AND DATA


M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    Nov. 06, 2018                  Phase:               L1
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 13/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    May 29, 2018                   Phase:               Neutral
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 14/21


                                                                   Date of Issue: January 23, 2019
                         WH Technology Corp.                       Report No. : WH-FCC-R18112104
                                                                   FCC ID. : 2AROV-GPMB10



7.         TEST OF RADIATED EMISSION
     7.1   TEST LIMIT

            In any 100kHz bandwidth outside the frequency band in which the spread
            spectrum or digitally modulated intentional radiator is operating, the radio
            frequency power that is produced by the intentional radiator shall be at least 20dB
            below that in the 100kHz bandwidth within the band that contains the highest level
            of the desired power, based on either an RF conducted or a radiated
            measurement. If the transmitter measurement is based on the maximum
            conducted output power, the attenuation required under this paragraph shall be
            30dB instead of 20dB. In addition, radiated emissions which fall in section
            15.205(a) the restricted bands must also comply with the radiated emission limit
            specified in section 15.209(a).




     7.2   TEST PROCEDURES

            a. The EUT was placed on a rotatable table top 0.8 meter above ground.
            b. The EUT was set 3 meters from the interference receiving antenna which was
               mounted on the top of a variable height antenna tower.
            c. The table was rotated 360 degrees to determine the position of the highest
               radiation.
            d. The antenna is a broadband antenna and its height is varied between one meter
               and four meters above ground to find the maximum value of the field strength
               both horizontal polarization and vertical polarization of the antenna are set to
               make the measurement.
            e. For each suspected emission the EUT was arranged to its worst case and then
               tune the antenna tower (from 1 M to 4 M) and turn table (from 0 degree to 360
               degrees) to find the maximum reading.
            f. Set the test-receiver system to Peak or CISPR quasi-peak Detect Function and
               specified bandwidth with Maximum Hold Mode.
            g. If the emission level of the EUT in peak mode was 3 dB lower than the limit
               specified, then testing will be stopped and peak values of EUT will be reported,

                                              Page 15/21


                                                            Date of Issue: January 23, 2019
                   WH Technology Corp.                      Report No. : WH-FCC-R18112104
                                                            FCC ID. : 2AROV-GPMB10



         otherwise, the emissions which do not have 3 dB margin will be repeated one by
         one using the quasi-peak method and reported.
      h. For testing above 1GHz, the emission level of the EUT in peak mode was 20dB
         lower thanaverage limit (that means the emission level in peak mode also
         complies with the limit in average mode), then testing will be stopped and peak
         values of EUT will be reported, otherwise, the emissions will be measured in
         average mode again and reported.
      i. “ Cone of radiation ” has been considered to be 3dB bandwidth of the
         measurement antenna.


7.3   TYPICAL TEST SETUP

      Radiated Emission Test Set-Up, Frequency Below 30MHz




      Radiated Emission Test Set-Up, Frequency 30MHz-1000MHz




                                       Page 16/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10



  7.4   TEST RESULT AND DATA (9KHZ ~ 30MHZ)


M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    Nov. 08, 2018                  Phase:               Vertical
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 17/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    Nov. 08, 2018                  Phase:                Vertical
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 18/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




  7.5   TEST RESULT AND DATA (30MHZ ~ 1GHZ, WORST EMISSIONS FOUND)


M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    Nov. 08, 2018                  Phase:               Vertical
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 19/21


                                                               Date of Issue: January 23, 2019
                   WH Technology Corp.                         Report No. : WH-FCC-R18112104
                                                               FCC ID. : 2AROV-GPMB10




M/N :          GP-MB10                        Test Voltage:        AC 120V/60Hz
Test Date :    Nov. 08, 2018                  Phase:                Horizontal
Temperature:   20℃                            Relative Humidity: 54%
Pressure:      101.0KPa                       Test by:             Bing
               PD Charging to Laptop+Charging to Phone+HDMI Playing to TV+USB 3.0 data
Test Mode:     transmission+USB 2.0 data transmission+SD Card data transmission
               +Wireless Charging to iWatch




                                         Page 20/21


                                                                   Date of Issue: January 23, 2019
                         WH Technology Corp.                       Report No. : WH-FCC-R18112104
                                                                   FCC ID. : 2AROV-GPMB10



8.         RESTRICTED BANDS OF OPERATION
            Only spurious emissions are permitted in any of the frequency bands listed below:




            **: Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz


     8.1    LABELING REQUIREMENT

            The device shall bear the following statement in a conspicuous location on the
            device: This device complies with part 15 of the FCC Rules. Operation is subject to
            the following two conditions: (1) This device may not cause harmful interference,
            and (2) this device must accept any interference received, including interference
            that may cause undesired operation.




                                           --END---

                                              Page 21/21



Document Created: 2019-01-23 13:08:33
Document Modified: 2019-01-23 13:08:33

© 2024 FCC.report